Transition Networks Milan Raven Series, Milan MIL-RCM16A-V2 User Manual

Page 1
Raven Series Modular
Media Converter System
MIL-RCM16A-V2 16 Slot Raven Conversion Modules
Managed Chassis with AC Power Supply
Page 2
Regulatory Approval
- FCC Class A
- UL 1950
- CSA C22.2 No. 950
- EN60950
- CE
- EN55022 Class A
- EN55024
Canadian EMI Notice
This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Regulations.
Cet appareil numerique de la classe A respecte toutes les exigences du Reglement sur le materiel brouilleur du Canada.
European Notice
Products with the CE Marking comply with both the EMC Directive (89/336/EEC) and the Low Voltage Directive (73/23/EEC) issued by the Commission of the European Community Compliance with these directives imply conformity to the following European Norms:
- EN55022 (CISPR 22) - Radio Frequency Interference
- EN61000-X - Electromagnetic Immunity
- EN60950 (IEC950) - Product Safety
One-Year Limited Warranty Transition Networks warrants to the original consumer or purchaser that each of it's products, and all components thereof, will be free from defects in material and/or workmanship for a period of one year from the original factory shipment date. Any warranty hereunder is extended to the original consumer or purchaser and is not assignable. Transition Networks makes no express or implied warranties including, but not limited to, any implied warranty of merchantability or fitness for a particular purpose, except as expressly set forth in this warranty. In no event shall Transition Networks be liable for incidental or consequential damages, costs, or expenses arising out of or in connection with the performance of the product delivered hereunder Transition Networks will in no case cover damages arising out of the product being used in a negligent fashion or manner.
Trademarks
The MiLAN logo and Transition Networks trademarks are registered trademarks of Transition Networks in the United States and/or other countries.
To Contact Transition Networks
For prompt response when calling for service information, have the following information ready:
- Product serial number and revision
- Date of purchase
- Vendor or place of purchase You can reach Transition Networks technical support at:
E-mail: techsupport@transition.com Transition Networks 10900 Red Circle Drive Minnetonka, MN 55344 United States of America
Telephone: +1.800.526.9267 Fax: : +1.952.941.2322
http://www.milan.com info@ Transition.com
© Copyright 2006 Transition Networks
Page 3
FCC Warning
This Equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.  Increase the separation between the equipment and receiver.  Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
CE Mark Warning This is a class A product. In a domestic environment this product may cause radio interference in
which case the user may be required to take adequate measures.
Page 4
Content
Content ..................................................................................4
Introduction...........................................................................1
Features....................................................................................................1
Software Feature......................................................................................2
Management Methods..............................................................................4
Console and Telnet Management......................................................4
Web-based Management ..................................................................4
SNMP Network Management............................................................4
Package Contents ....................................................................................5
Hardware Description...........................................................6
Physical Description .................................................................................6
Front & Rear Panel...................................................................................6
LED Indicators..........................................................................................7
System Cabinet .................................................................................7
Connecting to the Network.................................................10
Pre-Installation Requirements.................................................................10
Mounting the Device...............................................................................10
Desktop Installation .........................................................................11
Attaching Rubber Pads.............................................................11
Rack Mounting..........................................................................11
Power On................................................................................................12
Diagnostic Test.......................................................................................13
Connecting the Device via Local console or Telnet................................13
Console Management.........................................................16
Device Setting.........................................................................................16
Modules Settings....................................................................................18
Redundant Power Status........................................................................20
Events Log..............................................................................................21
Page 5
SNMP Trap.............................................................................................21
Secure IP for Telnet, HTTP and SNMP ..................................................22
Port Counters..........................................................................................23
Fan Status ..............................................................................................23
Save Current Settings.............................................................................24
Factory Default Settings & Reboot System.............................................24
Reboot System.......................................................................................25
TFTP Configuration ................................................................................25
Web-Based Management....................................................26
About Web-based Management.............................................................26
System Login..........................................................................................27
Modules settings.....................................................................................29
Port Counter ...........................................................................................34
IP Config.................................................................................................35
SNMP .....................................................................................................36
Event Log................................................................................................37
Miscellaneous Settings...........................................................................38
Save and Reboot....................................................................................40
Upgrade..................................................................................................41
Help ........................................................................................................42
SNMP Management.............................................................43
SNMP Management ...............................................................................43
Specification........................................................................45
Page 6
Introduction
The 16 Slots intelligent converter chassis is a combination of 16-slot host cabinet and several of optional media converter bracket modules. A maximum 16-bracket module can be installed in the cabinet with two redundant power supplies. The Power supply supports AC input type with load sharing redundant feature. The converter supports TS-1000 standard that provides loop back test to ensure the converter failure and remote configuration that allows remote set-up for the module of the converter or the converter.
With build-in Web-based Management, managing and configuring the 16 Slots intelligent converter chassis becomes easier. Users can visually configure and manage their network via the Web browser. Besides, the 16 Slots intelligent converter chassis can also be managed via Telnet, Console, or third-party SNMP Management.
Features
16 slots converter chassis with 2 power slots  AC power with Redundant  Maximum 16 slots for media converter  HTTP, Telnet security  IP address security for management station  Web and TFTP firmware upgrade  Built-in Link Lost Forwarding (LLF)/Link Fault Pass-Through (LFP)  Back-door password supported  Module identification  Fiber Module hot-swappable  CPU module hot-swappable  SNMP, Web, Telnet, console management  Optional different converter modules: 10/100TX to 1
1
00FX module,
Page 7
100/1000TX to Gigabit fiber module, 100/1000TX to Mini-GBIC module, and 100FX WDM module
100FX and Gigabit modules support single mode or multi mode fiber  Supports TS-1000 on 10/100TX to 100FX module and 100FX WDM
module
Event log and SNMP Trap supported  SNMP MIB II and private MIB supported  Supports Simple Network Time Protocol (SNTP)  Power and Fan Detect  Loop Back Test  EIA RS-310C 19 “ standard
Software Feature
Management
Web/Telnet
MIBS
SNMP Trap
Telnet Web Console (RS-232)
Web and Telnet function Can be enabled or disabled
RFC 1213 MIB II Private MIB
Link down Link up Power module status change Authorization Fail Module plug in and plug out Chassis configuration change Module configuration change
2
Page 8
de
port link down, the fiber
by CLI
Software Upgra
Link Loose Forward
Packet counter
Firmware upgrade by Web interface and TFTP
Each module supports LLF feature. It can be set by Web or CLI menu
LLF Mode TX
Fiber: TX
port will be forced down LLF Mode Fiber →→ TX : Fiber port link down, the
TX port will be forced down TX port: IN-good / In-bad packet counter
out-good /out-bad packet counter collision counter
Fiber port: IN-good / In-bad packet counter
out-good /out-bad packet counter
SNMP Trap Node Up to 4 Trap nodes
IP security for telnet
IP security
HTTP and SNMP access Up to 4 IP nodes when security is enabled
TS-1000 Loop back test, remote configuration
SNTP RFC2030 Simple Network Time Protocol
Up to 4095 event records. It can be reviewed
Events log
and Web browser mode
3
Page 9
Management Methods
The 16 Slots intelligent converter chassis supports following management methods:
Console and Telnet Management  Web-based Management  SNMP Network Management
Console and Telnet Management
Console Management is done through the RS-232 Console Port that requires a direct connection between PC and the Device. Once the Device is on the network, you can use Telnet program to Log in and modify the configuration. The default IP address is 192.168.1.77 with a subnet mask of 255.255.255.0. This default address can be used to login and change the configuration using Telnet.
Web-based Management
The 16 Slots intelligent converter chassis provides an embedded HTML web program in flash memory. It offers advanced management features and allows users to manage the 16 Slots intelligent converter chassis from anywhere on the network through any HTTP browser such as Microsoft Internet Explorer. For more information, please see the section of Web-Based Management.
SNMP Network Management
SNMP (Simple Network Management Protocol) provides a way to monitor and control network device, such as configurations, statistic collection, performance, and security.
Data is collected by SNMP agents, which are hardware & software processes reporting activity in each network device. The agent reports information contained in a MIB format (Management Information Base), which is a data structure that defines what is obtainable from the device and what can be controlled.
4
Page 10
Package Contents
Unpack the carton of the 16 Slots intelligent converter chassis and verify them against the checklist below:
16 Slots intelligent converter chassis  Power Cord  Four Rubber Pads  RS-232 cable  User Manual
16 Slots intelligent converter chassis Rubber Pads Rack-mounted Kit
RS-232 cable User Manual Power Cord
Package Contents
Compare the contents of your 16 Slots intelligent converter chassis package with the standard checklist above. If any item is missing or damaged, please contact the local dealer for service.
5
Page 11
Hardware Description
The 16 Slots intelligent converter chassis is a modular unit that contains 16 slots and 2 power slots. All optional models come with the built-in CPU, and the RS-232 port is used for Out-of-Band Management and one Ethernet RJ-45 connector is for In-band management that both in front panel.
This section mainly describes the hardware of the 16 Slots intelligent converter chassis and gives a physical and functional overview on certain module converter.
Physical Description
The physical dimensions of the 16 Slots intelligent converter chassis is 448mm x 279mm x 89mm (Lx W x H)
Front & Rear Panel
The front panel of 16 Slots intelligent converter chassis with the cabinet and modules is shown as figure below:
Front Panel (within all modules)
The 3-pronged power plug is located at the Rear Panel of the 16 Slots intelligent converter chassis as shown in Figure 2-2. The AC power is in the range between 100 and 240V
, 50-60Hz (AC type power supply). System can
AC
6
Page 12
install two units with the same power type. The Factory Default is one power module unit and one Fan Unit.
Power Slot B is installed a FAN unit
Rear Panel of the 16 Slots intelligent converter chassis
Power Slot A with AC Power Module
LED Indicators
All LED status indicators are located on the front panel of the modules. They display real-time indication of system and operational status.
System Cabinet
CPU Panel
7
Page 13
LED Status Meaning
CPU Ready
Blink (Green)
System kernel is working correctly
PWR Green Power on
Green Power Module A Ready
Good A
Off Power Module A Not Ready
Green Power Module B Ready
Good B
Fail A
Fail B
Off Power Module B Not Ready
Orange Power Module A Fail
Off Power Module A Ready
Orange Power Module B Fail
Off Power Module B Ready
8
Page 14
LK/ACT
FDX
Ethernet port is connected with the
Green
device.
Blink The port is receiving or transmitting data
Yellow Ethernet is linked with Full Duplex mode
Blink Collision of Packets occurs in the port.
Descriptions of the System and CPU LED
9
Page 15
Connecting to the Network
This chapter provides the installation procedure.
Pre-Installation Requirements
Before to start hardware installation, make sure the installation environment has following items:
PCs with 10/100Base-TX Ethernet cards: The PC must have a standard
Ethernet interface to connect with the Device.
UTP/STP cable with RJ-45 connector: Check the cable and connectors
work properly.
Fiber cable with SC/ST/MT-RJ/VF-45 connector: Check the cable and
connector types are correct.
A power outlet: 100 to 240V AC at 50 to 60 Hz. Make sure that the
Device power is accessible and cables can be connected easily.
D
A dry cool place: Keep the device away from moisture. Avoid direct
Mounting tools: If user intends to mount the device on a rack, make sure
edicated power supply: Use dedicated power circuits or power
conditioners to supply reliable electrical power to the network devices.
sunlight, heat source, and high amount of electromagnetic interference around.
have all the tools, such as mounting brackets and screws.
Mounting the Device
The 16 Slots intelligent converter chassis is suitable for an office environment where it can be rack-mounted in standard EIA 19-inch racks or standalone.
10
Page 16
Desktop Installation
Set the device on a sufficiently large flat space with a power outlet nearby. And, the surface where user put the device should be clean, smooth, level, and sturdy. Please make sure there is enough spacing around the device to allow attaching of cables, power cord and air circulation.
Attaching Rubber Pads
1. Make sure mounting surface on the bottom of the device is grease and dust free
2. Remove adhesive backing from Rubber Pads
3. Apply the Rubber Pads to each corner on the bottom of the device. (These footpads can prevent the device from shock/vibration.)
Attaching Rubber Pads to each corner of the Device’s bottom
Rack Mounting
The 16 Slots intelligent converter chassis come with a rack-mounted kit and can be mounted in an EIA standard size/19-inch Rack. Perform the following steps for rack mounting the device:
1. Position one bracket to align with the holes on the side of the device and secure it with the bracket screws. Then attach the remaining bracket to the other side of the Device.
11
Page 17
Attach mounting brackets with screws
2. After attached both mounting brackets, position the device in the rack by lining up the holes in the brackets with the appropriate holes on the rack. Securing the device to the rack with a screwdriver and the rack-mounting screws.
Mount the converter chassis in an EIA standard 19-inch Rack
[NOTE] For proper ventilation, allow at least 4 inches (10 cm) of clearance on the front and 3.4 inches (8 cm) on the back of the Device. This is especially important for enclosed rack installations.
Power On
After all network cables are connected, plug the power cord into the power socket on the back panel and the other end into a power outlet, and then turn
12
Page 18
the power switch on.
Check the front panel Power indicator to see if power is properly supplied. The device with the universal power supply, so there is no more adjustment needed.
Diagnostic Test
After the installation is completed and AC power is applied to the device properly, the system will automatically perform a diagnostic testing. When the Power LED is on within 4 seconds, the CPU Ready LED will become “Blink” and then the system is ready. On the other hand, if the CPU LED always light on, it means system crash.
Connecting the Device via Local console or Telnet
The serial console port is a male DB-9 connector that enables the connection from PC or terminal for monitoring and configuring the Device.
Use the supplied RS-232 cable with a female DB-9 connector to link the terminal or PC to the console port.(The terminal or PC must support the terminal emulation program)
For the telnet management, user has to set the device IP address that the same network class with PC’s. (For example; it factory default IP address is
192.168.1.77, then the PC IP address should be 192.168.1.156)
Default login user name: r Default login password: root
oot
13
Page 19
Connecting the Device to a terminal via RS-232 cable
After connected to the Console port, turn the PC or terminal on and configure its communications parameters to match the following default characteristics of the console port:
Baud Rate: 9600 bps Data Bits: 8 Stop Bit: 1 Parity: none Flow control: None
The setting of communication parameters
Run Hyper Terminal or a terminal emulation program using the above settings for Console Management. After user has finished parameter settings, press Enter and key the login username and password. The default login username and password both is “root”. After authentication, enter “m” to enter main menu.
14
Page 20
The Main Menu
15
Page 21
Console Management
In this chapter, console management will be described individual function. In fact, console management mode is a line menu mode. User can enter the number of function to configure the function.
Device Setting
Select Device settings (Type “1” and press “Enter”) from the main menu. It displays the list of device settings items, ex: system name, location, IP… and so on. User can enter the number to modify the value.
Device Settings interface
[NOTE] The item “0.1, 0.2, 0.3” can’t be modified.
1. Device Name: Set a system name for this device (Character maximum
length is 64)
2
. Location: the description for the location of device(Character
maximum length is 64)
16
Page 22
3. Contact: the description for the contact people of device(Character
maximum length is 64)
4. IP Address: The IP address of the device(The default IP is
192.168.16.77)
5. Subnet Mask: The default value is 255.255.255.0 6. Default Gateway: The default value is 192.168.16.254 7. Change User/Password: User can change to other username or
password (The default username and password is root)
8
. Get Request Community: The community string for get(The default
value is Public)
9. Set Request Community: The community string for set(The default
value is “Public)
A. HTTP Enable: To allow user to configure the converter through Web  B. Telnet Enable: To allow user to remote telnet to the converter for
configuring
C. Set SNTP Config: Configuring the SNTP (Simple Network Time
Protocol) settings. The SNTP allows user to synchronize switch clocks in the Internet 1. Enable/Disable Sntp Client: To enable or disable SNTP function
to get the time from the SNTP server
2
. Set Sntp Server 1 Ip: Set the SNTP server IP address
3. Set Sntp Server 2 Ip: Set the SNTP server IP address  4. Set Sntp Server 3 Ip: Set the SNTP server IP address  5. Set UTC Timezone: Set the switch location time zone  7. Enable/Disable Daylight Saving: To enable or disable daylight
saving function
8. Set Daylight Saving Period: When daylight saving is enabling,
user can set up the daylight saving period
9. Set Daylight Saving Offset: Set up the daylight saving time offset
value.
A. Enable/Disable Auto Sync to SNTP server: Automatically
synchronize time with the SNTP server
B
. Set Auto Sync period: Set up the time that automatically
synchronizes time with SNTP server
17
Page 23
Q. Quit: Exit from the current configuration interface
Remember to return the Main Menu to Save the modified settings, and then reboot the device. User may have to press Enter again when the device is finished reboot.
Modules Settings
Configure the operation mode of the media converter modules. Input “2” and press “Enter “at main menu interface. The system will guide the user to select the module for configuration (Enter the number of module, ex: ‘1’ and then press “Enter”).
After entering the module configuration mode, the module configuration interface will list the items as shown in the figure below. Selections 1 ~ 7 allow users to configure the module settings. The items of 0.1 ~ 0.5 are read-only information. Enter the number of selection to modify the value.
18
Page 24
Module setting interface (support TS-1000 module)
1. Module enable/disable: Enable or disable module function (The
default is “Enable”).
2. LLF enable/disable: When the RJ-45 or Fiber is link down, it will force
the other port disconnect automatically. The forced way is depends on the RJ-45 control Fiber or Fiber control RJ-45 port. The LLF default is “RJ-45 Control FX” and other selections are “Fx Control RJ-45” and “Disable”. On the module that support TS-1000 only can enable or disable the LLF function but can not configure the LLF direction
3
. RJ-45 Port Speed/ Duplex: Configuring RJ-45 port speed and
mode.(The default is “10M/Half”)
4. Fiber Port Speed/Duplex: Configuring Fiber port speed and mode(The
default is “10M/Half”)
5. Reset to default: To reset the module configuration to default value  6. Note: Entering the short description or note for this module  7. TS-1000 Setting: It is used for configuring the TS-1000 functions. Only
the module supporting TS-1000 standard has this configuration item. 1. Embedded SSRAM BIST: To test central site converter module
status. When test back value is OK which means the central site converter module is normal. When test back value is fail or didn’t test, it means the central site converter module is fail
2
. Power off Alarm (POA): To enable or disable the power off alarm
19
Page 25
function. Enable means before the remote converter power off, the remote converter will send out the alarm notice to the central manager converter
3. In-Band Loop Back Test: Checking the fiber port connection
status between remote and central site converter. User needs to set a transfer value, and verify the return value is for verifying if the value the same as user has set
4
. Auto Loop Back Test: Checking the fiber port connection status
between remote and central site converter automatically
5. Bandwidth rate control & Terminal Tx port Config: Bandwidth
rate control terminal UTP port
6. Terminal Tx port Table (Read only): Displaying the terminal UTP
port table information
8. Auto Polling: Set the value as ‘True’ to enable auto polling. When Auto
Polling is set as ‘True’, the management board then is able to communicate with the particular module.
Q. Quit: Exit from the current interface
Redundant Power Status
It shows current power supply status. The device has two slots for Power
20
Page 26
module, on the left is power A, and on the right is power B. In main menu interface, enter “3” and press enter. Then, user will see as the following figure.
Redundant Power Status interface
Events Log
The system provides 4095 event records 1. Event Log Enabled: The System will start record events when it is
enable
2. Show Event Log: For viewing event log records. To enable “Event Log
Enable” function
3. Delete All Event Log: Removing all event log entries which are stored
in system Flash Rom
Q. Quit: Exit from the current interface
Event Log interface
SNMP Trap
Configure SNMP Trap station. User can configure up to 4 IP address for trap.
1
. Send Trap: To enable or Disable Trap function
21
Page 27
2. Trap community: The Trap station must have same community string
and can get trap information from this device(The maximum trap community string length is 32 characters. The default community string is “public”)
3~4. Trap IP 1~4: Assign the trap station’s IP address. Only the
authorized station can receive the Trap information
Q. Quit: Exit from the current interface
SNMP Trap interface
Secure IP for Telnet, HTTP and SNMP
Configuring security management for Telnet, Web management and SNMP( four would be the maximum number of stations), If the function is enabled, then only the authorized station that with right IP address can manage this device.
Secure IP interface
1. Secure IP for Telnet: To Enable or disable the secure Telnet IP
22
Page 28
function
2. Secure IP for HTTP: To Enable or disable the secure HTTP IP function  3. Secure IP for SNMP: To Enable or disable the secure SNMP IP
function
4~7. Secure IP 1~4: Assigning the IP that can manage the device through
Telnet, HTTP and SNMP
Q. Quit: Exit from the current interface
Port Counters
Viewing UTP and fiber port counter information
1. RJ-45: Viewing all the UTP port counter information  2. Fiber: Viewing all fiber port counter information  3. Reset: Reseting all port counters  Q. Quit: Exit from the current interface
Port Counters interface
Fan Status
For newest Fan status viewing, press “enter” key to bring it up
Fan Status interface
23
Page 29
Save Current Settings
After modifying, the parameters still not save in the system. User need to do the save action, then all the parameters will be stored in system Flash Rom. The values will be effect after reboot. Enter “R” and press “Enter” key to save the current settings.
Save Current Settings interface
Factory Default Settings & Reboot System
To reset the system configuration back to original settings. After reboot, the system configuration will set to default value. Enter “D” and press “Enter” key. There are three optional selections that user can decide to set back to default value or keep current value.
M
IP settings: User might keep current IP address when the system set to
odule settings: User might keep current configure value when the system set to factory default settings. Enter “n” the current configure value will remain after the system set to factory default. Enter “y” the current configure value will be set to the factory default setting.
factory default settings. Enter “n” the current IP address will remain after the system set to factory default. Enter “y” the current IP address will be set to the factory default setting.
Factory default settings & Reboot system interface
24
Page 30
Reboot System
To reboot the system without set the system configuration back to default. Enter “R” and press “Enter” key.
TFTP Configuration
Use TFTP function to update the firmware
1. Set TFTP Server IP: set up the TFTP server IP address  2. Set File Name: set up the firmware file name  3. Update Firmware: execute the TFTP update firmware  Q. Quit: exit from the current interface
TFTP Configuration interface
25
Page 31
Web-Based Management
About Web-based Management
The 16 Slots intelligent converter chassis support embedded HTML web manage. It offers advanced management features and allows users to manage the device from anywhere on the network through a standard browser such as Microsoft Internet Explorer.
The Web-Based Management supports Internet Explorer 5.0. And, it is applied with Java Applets for reducing network bandwidth consumption, enhance access speed and present an easy viewing screen.
[NOTE] By default, IE5.0 or later version does not allow Java Applets to activate sockets. In fact, the user has to explicitly modify the browser setting to enable Java Applets to operate network ports.
The user has to download the Java Run Time Environment application to enable Java Applets. Please go to http://java.sun.com/products/archive/ the JDK/JRE Version 6 update 7.
[NOTE] The Web-Based Management support only JDK/JRE Version 6 update 7, there is no commitment on the compatibility of other Java
environment
, select
26
Page 32
System Login
Follow the step below to login system
1. Start Internet Explorer
2. Key in” http://” + “the IP address of the 16 Slots intelligent converter
JDK/JRE download page
chassis” (for example, the Factory default is 192.168.16.77) and press “Enter” key.
The authentication Window
3. The authentication screen appears
27
Page 33
4. Key in the user name and password. The default is “root” for both
5. Press “Enter” or Click ”OK”, then the Home Screen of the Web-based management appear right after
Web management Home interface
The Home page displays the configuration of the 16 Slots intelligent converter chassis.
Device Name: An administratively assigned name of the managed unit
that can be modified in SNMP page
Location: The physical location of this managed unit (e.g., laboratory, 3rd
floor) that can be modified in SNMP page
Contact: The contact person for this managed unit that can be modified in
SNMP page
System Up Time: The time last since the managed unit was re- initialized.
It is read only
Sntp Time: Display SNTP time status
P Address: The IP address of the managed unit that can be modified in
I
IP Config page. Factory Default is 192.168.16.77
S
ubnet Mask: The subnet mask of the managed unit can be modified in
28
Page 34
IP Config page. Default is 255.255.255.0
Default Gateway: The default gateway of the managed unit that can be
modified in IP Config page. Factory Default is 192.168.16.254.
MAC Address: The MAC address of the managed unit. It is read only  Console: display console parameter information  Redundant Power status: Display the redundant power status  Firmware Version: The firmware version of the management unit. It is
read only. User can online upgrade the new firmware if the new version is released
H
ardware Version: The hardware version of the converter. It is read only
Modules settings
Modules settings show the modules that installed on the 16 Slots intelligent converter chassis. In modules settings, it has 4 parts for configure—module, RJ-45 Port, Fiber Port, and Note.
Modules Settings interface
29
Page 35
Module
State: It displays the module current status. User can enable or disable
the module state. When the state is disabling, this module cannot be configured
Mode: It shows the module mode. The mode was auto detected by
system when installed on the device. When the mode is TS-1000, it means this module supports TS-1000 standard and then click TS-1000 configuration button to configure the TS-1000 function
L
LF enable/disable: When the RJ-45 or Fiber is link down, it will force the
other port disconnect automatically. The forced way is depends on the RJ-45 control Fiber or Fiber control RJ-45 port. The LLF default is “RJ-45 Control FX” and other selections are “Fx Control RJ-45” and “Disable”. On the module that support TS-1000 only can enable or disable the LLF function but can not configure the LLF direction
Default: set the module back to default value 
TS-1000 setting:
click config # to enter the TS-1000 setting interface
30
Page 36
TS-1000 setting interface
Central TS-1000 RJ-45 port setting: The RJ-45 port of the central
site setting.
Link: The port link status  Speed: Configure the port speed in force negotiation mode –
100Mbps or 10 Mbps
Duplex: When the port negotiation is in force mode, user can
configure duplex mode – half or full
Auto-Negotiation: Configure the negotiation mode – auto or
force
Bandwidth Input Rate: Configure the input bandwidth rate –
10/100Mbps, 2.5/ 25Mbps, 5/50Mbps, or 7.5/75Mbps
B
andwidth output Rate: Configure the output bandwidth rate –
10/100Mbps, 2.5/ 25Mbps, 5/50Mbps, or 7.5/75Mbps.
31
Page 37
Central TS-1000 reset default: Set the configuration back to the
default settings
And then, click Apply to apply the configuration  Terminal TS-1000 RJ-45 port setting: The RJ-45 port of the terminal
site setting. When the connection is established between the central site, user are able to configure the terminal site
Link: the port link status  S
peed: Configure the port speed in force negotiation mode –
100Mbps or 10 Mbps
Duplex: When the port negotiation is in force mode, you can
configure duplex mode – half or full
Auto-Negotiation: Configure the negotiation mode – auto or
force
Bandwidth Input Rate: Configure the input bandwidth rate –
10/100Mbps, 2.5/ 25Mbps, 5/50Mbps, or 7.5/75Mbps
Bandwidth output Rate: Configure the output bandwidth rate –
10/100Mbps, 2.5/ 25Mbps, 5/50Mbps, or 7.5/75Mbps
Terminal TS-1000 reset default: Set the configuration back to the
default settings
And then, click 
Verify Test:
Apply to apply the configuration
Set up some TS-1000 loop back test
Embedded SSRAM BIST: To test central site converter module
status. When test back value is OK, it means the central site converter module is normal. When test back value is fail or didn’t test, it means the central site converter module is fail
In-Band Loop Back Test: Checking the fiber port connection
status between remote and central site converter. User needs to set a transfer value and verify the return value same as user has set
Auto Loop Back Test: Checking the fiber port connection status
between remote and central site converter automatically
When all items are set, click 
TS-1000 POA setting:
Set up the power off alarm function
Test to start the testing
32
Page 38
Power off Alarm (POA): To enable or disable the power off
alarm function. Enable -- before the remote converter power off, the remote converter will send out the alarm notice to the central manager converter
And then, click Apply to apply the configuration
RJ-45 Port L
ink: Showing the RJ-45 port current link status
Nego: Select the negotiation mode
Auto means the system automatically select the speed(Default)  Force means the user can select the speed
Speed: Select the speed of port (Make sure the “Nego” column is set as
Force”; Otherwise, the speed function will be disable)
Duplex: Select the Duplex mode. (Make sure the “Nego” column is
Force”; Otherwise, the duplex function is disabling)
Fiber Port
Link: It shows the RJ-45 port current link status  Nego: Select the negotiation mode  Speed: Select the speed of port  Duplex: Select the Duplex mode 
Note:
A note can be filled in for this module within maximum characters is
32
After modifying, click Apply to have the configuration taken effect.
33
Page 39
Port Counter
Display all port counter information in here Click
Refresh
to get current information
Rx Good Pkts(R): Amount of good packets has received/R means RJ-45
port
Rx Bad Pkts(R): Amount of good packets has received/R means RJ-45
port
Tx Good Pkts(R): Amount of good packets has transmitted/R means
RJ-45 port
Tx Bad Pkts(R): Amount of bad packet has transmitted/R means RJ-45
port
Tx Collision (R): Amount of transmit collision/R means RJ-45 port Rx Collision (R): Amount of receive collision/R means RJ-45 port Rx Good Pkts(F): Amount of good packets has received/F means Fiber
port
Rx Bad Pkts(F): Amount of good packets has received/F means Fiber
port
Tx Good Pkts(F): Amount of good packets has transmitted/F means Fiber
port
Tx Bad Pkts(F): Amount of bad packet has transmitted/F means Fiber
port
Tx Collision (F): Amount of transmit collision/F means Fiber port Rx Collision (F): Amount of receive collision/F means Fiber port
34
Page 40
IP Config
Port Counter interface
Changing of the IP address, subnet mask, and default gateway. Just simply fill in the new IP address, subnet or default gateway in corresponding column.
Then, click
Apply
to have the configuration taken effect. Users should
reboot system to restore the new settings.
IP Config interface
35
Page 41
SNMP
Configuring device name, location, contact, the "get request", "set request" and Trap community string. The default value of get request, set request and Trap community is “
public
”. These three parameters must be correctly to performed
"get request" from the management unit, "set request" to the management unit and send trap to the management unit, then click
Apply
to have the
settings taken effect. There are up to 4-trap management stations could set to receive the trap packets from the 16-slot chassis converter. Check marks the “
send traps to the following management stations
of trap management station. Remember to set the
” and fill in the IP address
Trap community
while send and receive trap packet between the converters and trap management stations. The trap community must be same between the converters and trap
management station. At last, click
Apply
to have the configuration taken
effect.
SNMP interface
36
Page 42
Event Log
To enable the event log function and view the event logs
Click
Or, press
Enable
Refresh
to enable the event log function
to get the event logs. The system will not auto
refresh the event log
To stop the event log function, click
Disable
To clear all event logs in the display frame, press
Clear All
Event Log interface
37
Page 43
Miscellaneous Settings
Enable/Disable Telnet:
function. The default value is “enable”
User can enable or disable the remote telnet
And then, click 
Enable/Disable HTTP:
The default value is “enable”
And then,
Click
Apply
Apply
to have the configuration taken effect To enable or disable the remote HTTP function.
to have the configuration taken effect.
SNTP Configuration: Configure the SNTP (Simple Network Time
Protocol) settings. The SNTP allows user to synchronize switch clocks in the Internet.
Enable/Disable Sntp Client: To enable or disable SNTP function to
get the time from the SNTP server
Sntp Server 1 IP: Set the SNTP server IP address Sntp Server 2 IP: Set the SNTP server IP address Sntp Server 3 IP: Set the SNTP server IP address UTC Timezone: Set the switch location time zone Enable/Disable Daylight Saving: To enable or disable daylight
saving function
Daylight Saving Period: When daylight saving is enabling, you can
set up the daylight saving period
Daylight Saving Offset (minutes): Set up the daylight saving time
offset value
Update System Time:
click
Apply
to update the system time
SNTP auto sync: To enable or disable automatically synchronize
time with the SNTP server
SNTP auto sync period (minutes): Set up the time that
automatically synchronizes time with SNTP server
Change Password: Re-set the login username and password. Mark the
check box to enable password change setting
Username (max 15): Key in the new username(The maximum of
length is 15 characters)
38
Page 44
Password (max 15): Key in the new password(The maximum of
length is 15 characters)
Confirm Password: Re-enter the new password for confirmation
Misc Settings Interface
Security IP: Configure security management for Telnet, Web management
and SNMP, and the maximum number of stations are 4, if the function is
39
Page 45
enabled then only the authorized station that with right IP address can manage this device.
Secure IP 1~4: Assign the IP that can manage the device through
Telnet, HTTP and SNMP
Secure IP for Telnet: To enable or disable the secure Telnet IP
function
Secure IP for HTTP: To enable or disable the secure HTTP IP
function
Secure IP for SNMP: To enable or disable the secure SNMP IP
function
Save and Reboot
Save Current Settings:
Current Settings" and click the executed automatically
Factory Default Settings & Reboot:
check the "Factory Default Settings& reboot" checkbox then click
Apply
the which are restoring modules back to default value or just IP address back
to default value
. There are two optional selections for user to choose from,
To save current settings by click the "Save
Apply
, then current settings will be
To use the factory default settings,
Default all Modules: User might keep current configure value when
the system is set as factory default settings
Reset to default IP address:
when the system is set as factory default settings
User might keep current IP address
Reboot system:
checkbox then click the seconds) then continue to operate the device
To reboot system, check the "
Apply
40
Reboot System
. Please wait a moment (about 15
"
Page 46
Save and Reboot interface
Upgrade
User can on-line upgrade the firmware of the device or use TFTP to update the firmware
Upgrade Firmware(using HTTP to update the firmware)
1. Using http to download the new version of firmware from vendor web site
2. Enter password in the " password is root, and it follows the user password change it could be changed by individual user.)
3. Enter the update firmware file in the "
Browse to find the file)
4. Click the
Upgrade
Password" box (Please note that the default
File Path
" box. (Click
[NOTE] If users can't upgrade the new firmware successfully, please try again
(Do not shut down the device!)
41
Page 47
Upgrade interface
Tftp Update(using tftp to update the firmware)
1. TFTP Server IP: set up the TFTP server IP address
2. File Name: set up the firmware file name
3. Click the
Tftp Upgrade
button to start updating.
Help
In each configuration section, user can click “Help” and the help window will pop up.
42
Page 48
SNMP Management
This section describes how to configure and manage the device by accessing Management Information Base (MIB) objects with the SNMP protocol.
SNMP Management
The device’s MIB options are accessible through SNMP. Also, instead of defining a large set of commands, SNMP performs all operations using the “GET”, “GETNEXT” and “SET” commands. And, the SNMP agent that resides on the device can respond to MIB-related queries being sent by the network management software.
The SNMP agent gathers data from the MIB, which keeps information about device parameters and network data. And then, the agent can send traps or notification of certain events to the manager.
Figure 6-1 SNMP Network
The SNMP manager uses information in the MIB to perform the operations described below:
Operation Description
Retrieve values of SNMP objects from a network
GET
device
43
Page 49
are
Specify an SNMP object in a network device and then
GETNEXT
SET
GET RESPONSE
TRAP
retrieve information about the rest of SNMP objects in the device
Modify and store values of SNMP objects in a network device
Replying the GET, GETNEXT, and SET commands sent by SNMP agent
A message sent by an SNMP agent to an SNMP manager indicating some event occurred
The commands of SNMP management
44
Page 50
Specification
This section provides the specifications of the converter modules
IEEE802.3 10BASE-T IEEE802.3u 100BASE-TX and 100BASE-FX with N-way auto negotiation
Standards
IEEE802.3ab Gigabit copper with N-way auto-negotiation IEEE802.3z for Gigabit fiber
100FX Module:
Connector
Fiber: Duplex ST/SC, Simplex SC (WDM
single mode)
RJ-45: CAT-5 (10/100Mbps) Twisted Pair
cable
Gigabit Module:
Fiber: Duplex SC (Single mode 10KM, Multi
mode 500Meters)
RJ-45 : CAT- 5 (1000Mbps) 4 pairs of
UTP/STP cable
CPU Board: RJ-45 for 10/100Mbps, Full/Half
Duplex. Cable support CAT-3/5 (10/100Mbps)
WDM module:
Fiber: Simplex SC (single mode 20KM) RJ-45: CAT. 5 2 pairs of UTP cable
Mini GBIC module: (for 3.3v only)
Fiber: SFP module (empty) RJ-45: CAT- 5 (1000Mbps) 4 pairs of UTP/STP cable
Switch architecture Store and Forward
45
Page 51
LED Indicators
Internal Packet Gap 960ns Filter illegal Error packet
CPU Module
CPU Ready, Power Good (A, B) Power Fail (A, B), TX (link/Act, FDX)
100FX Module
Power, TX (Link /Act, speed, FDX), FX (Link /Act, FDX)
Gigabit Module
Power, Gigabit Copper (Speed, 1000Mbps, LK/ACT, FDX/COL), Fiber (Link/Act, FDX/COL)
100/1000TX to MINI GBIC module
Power, Gigabit Copper (Speed, 1000Mbps, LK/ACT, FDX/COL), Fiber (Link/Act, FDX/COL)
Fiber parameters Fiber Core:
Multi-Mode (62.5/125um, 50/125um) Single-Mode (9/125µm)
Wavelength:
100Mbps multi-mode: 1310nm / 100Mbps single-mode: 1310nm 100M WDM 1310: TX 1310nm, RX 1550 nm 100M WDM 1550: TX 1550nm, RX 1310 nm
Available Fiber distance:
100Mbps module: Single-Mode Fiber (30 KM)
/ Multi-Mode (2KM)
100M WDM module (W13, W15): 20KM Gigabit modules: SX (Multi-mode) 500 Meters
LX (Single mode) 10 KM
Optical Transceiver parameter:
46
Page 52
100Mbps Multi-Mode: TX (–19dBm), RX (-31dBm), Power budget (12dBm) 100Mbps Single-mode (30KM): TX (–15 dBm), RX (-34 dBm), Power budget (19dBm) Gigabit SX Transceiver: TX (–9.5dBm), RX (12.5 dBm), Power budget (3dBm) Gigabit LX Transceiver: TX (–9.5dBm), RX (-20 dBm), Power budget (10.5dBm)
64 to 1518 Bytes for Non-VLAN Ethernet packet
Transparent packet
68 to 1522 Bytes for VLAN-Tag type Ethernet packet
Dimensions 448mmx 279mm x 89mm (W x D x H)
Operational
0ºC to 45ºC (32ºF to 113ºF)
Temperature Transparent packet 64 to 1518 Bytes for Non-VLAN Ethernet packet
68 to 1522 Bytes for VLAN-Tag type Ethernet packet
Redundant and Load Sharing function support (
Power Supply
AC: 90~240 VAC, 50/60 HZ
EMI & Safety FCC Class A / CE / UL
10900 Red Circle Drive Minnetonka, MN 55344
Tel.: +1.952.941.7600
techsupport@transition.com
47