Transition Networks J/GE-CF-01(LX1), J/GE-CF-01(SX), J/GE-CF-01, J/GE-CF-01(LX100), J/GE-CF-01(LX101) User Manual

...
Page 1
User’s Guide
J/GE-CF-01
Stand-Alone Media Converter
• Gigabit Ethernet
• Copper to Fiber
• 1000Base-T to 1000Base-SX/LX
Transition Networks J/GE-CF-01 gigabit Ethernet media converter connects 1000Base-T shielded or unshielded twisted-pair copper cable to 1000Base­SX or 1000Base-LX, fiber-optic cable.
Part Number Port One - Copper Port Two - Duplex Fiber-Optic
J/GE-CF-01(SX) RJ-45 1000Base-T
100 m (328 ft)*
SC, 1000Base-SX, 850 nm multimode 220 m (722 ft)* (62.5/125
µm cable)
500 m (1,640 ft)* (50/125
µm cable)
J/GE-CF-01(LX1) RJ-45 1000Base-T
100 m (328 ft)*
SC, 1000Base-LX, 1310 nm single mode 10 km (6.2 miles)*
J/GE-CF-01(LX2) RJ-45 1000Base-T
100 m (328 ft)*
SC, 1000Base-LX, 1310 nm single mode 25 km (15.5 miles)*
J/GE-CF-01(LX6) RJ-45 1000Base-T
100 m (328 ft)*
SC, 1000Base-LX, 1550 nm single mode 65 km (40.4 miles)*
J/GE-CF-01(LX100) RJ-45 1000Base-T
100 m (328 ft)*
SC, 1000Base-LX, 1310(TX)/1550(RX)nm single mode 20K (12.4 miles)
J/GE-CF-01(LX101) RJ-45 1000Base-T
100 m (328 ft)*
SC, 1000Base-LX, 1550(TX)/130(RX)nm single mode 20K (12.4 miles)
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network installation.
Installation . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . .3
Cable Specifications . . . . . . . . .4
Technical Specifications . . . . .5
Troubleshooting . . . . . . . . . . . .6
Compliance Information . . . . .7
Page 2
2
J/GE-CF-01
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Installation
Install the Fiber Cable
1. Locate or build 1000Base-SX/LX compliant fiber cable with male, two­stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the J/GE-CF-01 media converter as described:
• Connect the male TX cable connector to the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector to the female RX port.
• Connect the male RX cable connector to the female TX port.
Install the Copper Cable
NOTE: The AutoCross™ feature automatically configures the media converter
to link up when connected to 1000Base-T devices, regardless if the copper cable is MDI (straight-through) or MDI-X (crossover).
1. Locate or build 1000Base-T compliant copper cables with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the J/GE-CF-01 media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.).
Connect the fiber cable to the media converter as shown.
C
onnect the fiber cable
to the other
de
vice
(
media co
n
v
er
ter
,
hub,
etc.) as s
ho
wn
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port
on the media
converter
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
Installation -- Continued
Power the Media Converter
AC
1. Connect the barrel connector on the power adapter to the media converter’s power port (located on the back of the media converter).
2. Connect the power adapter plug to AC power.
3. Verify that the media converter is powered by observing the illuminated LED power indicator light.
DC
Consult the user’s guide for the Transition Networks SPS1872-xx DC external power supply for powering the media converter.
Operation
Status LEDs
Use the status LEDs to monitor the J/GE-CF-01 media converter operation in the network.
PWR On = Connection to external AC or DC power.
FLNK On = Fiber link connection.
LACT On = Copper link connection.
Flashing = Activity on the copper link.
DPX/COLL On = Copper link at full-duplex.
Off = Copper link at half-duplex
Flashing = Collision condition on the half-duplex, copper link.
PWRFLNK
DPX/COLL
1000Base-T
LACT
1000BaseX
TX FX
Page 3
4
J/GE-CF-01
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate: <10-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
J/GE-CF-01(SX) 850 nm multimode Fiber Optic Transmitter Power: min: -10.0 dBm max: -4.0 dBm Fiber Optic Receiver Sensitivity: min: -17.0 dBm max: 0.0 dBm Link Budget: 7.0 dB
J/GE-CF-01(LX1) 1310 nm single mode Fiber-optic Transmitter Power: min: -9.5 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 10.5 dB
J/GE-CF-01(LX2) 1310 nm single mode Fiber-optic Transmitter Power: min: -5.0 dBm max: -0.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 15.0 dB
J/GE-CF-01(LX6) 1550 nm single mode Fiber-optic Transmitter Power: min: -3.0 dBm max: +2.0 dBm Fiber-optic Receiver Sensitivity: min: -23.0 dBm max: -3.0 dBm Link Budget: 20.0 dB
J/GE-CF-01(LX100) 1310/1550 nm single mode J/GE-CF-01(LX101) 1550/1310 nm single mode Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -21.0 dBm max: -3.0 dBm Link Budget: 13.0 dB
The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC-825/CDRH standards and comply with 21 CFR1040.10 and 21CFR1040.11.
Copper Cable
Category 5 -- minimum requirement
Gauge = 24 to 22 AWG; Attenuation = 22.0 dB /100m @ 100 MHz
• Shielded (STP) or unshielded (UTP) twisted-pair may be used
• All pin pairs (1&2, 3&6, 4&5, 7&8) are active in a gigabit network.
• Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Technical Specifications
For use with Transition Networks Model J/GE-CF-01 or equivalent
Standards: IEEE 802.3™ 2000
Data Rate: 1000 Mb/s
Dimensions: (w x d x h) 3.0" x 4.0" x 1.0" (76 mm x 121 mm x 25 mm)
Weight: 6 oz. (181 g) (approximate)
Power Consumption: 3.2 Watts; 260 mA @ 12 VDC
Power Supply 12VDC, 1.25 Amp
(The external power supply provided with this product is UL listed by the power supply’s manufacturer.)
Environment: Tmra*: 0 to 50°C (32 to 122°F)
Storage Temp: -15 to 65°C (5 to 149°F) Humidity: 5 to 95%, non condensing Altitude: 0 to 10,000 feet
Warranty: Lifetime
*Manufacturer’s rated ambient temperature.
The information in this user’s guide is subject to change. For the most up-to-date information on the J/GE-CF-01 media converter, view the user’s guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION:
Visible and invisible laser radiation when open. Do not stare into
beam or view directly with optical instruments.
CAUTION:
Use of controls, adjustments or the performance of procedures other
than those specified herein may result in hazardous radiation exposure.
Optional Accessories (sold separately).
Part Number Description SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
SPS-1872-CC Optional External Power Supply; 18-72VDC Piggy-back;
Output: 12.6VDC, 1.0 A
E-MCR-04 12-Slot Media Converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
WMBS Optional Wall Mount Brackets; 3.2 in. (91 mm) WMBD Optional DIN Rail Mount Bracket; 5.0 in. (127 mm) WMBD-FS Optional DIN Rail Mount Bracket (flat); 3.1in. (79 mm)
Page 4
6
J/GE-CF-01
24-hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
Troubleshooting
If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the Power LED illuminated? NO
• Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet?
• Is the power adapter properly installed in the media converter and in
the outlet?
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
• Proceed to step 2.
2. Is the Copper LED illuminated? NO
• Check the twisted-pair copper cables for proper connection.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
• Proceed to step 3.
3. Is the Fiber LED illuminated? NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the other device.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
• Proceed to step 4.
4. Is the Copper LED flashing? NO
• If there is no activity on the 1000Base-T port, proceed to step 5.
• If there is activity on the 1000Base-T port, disconnect and reconnect
the twisted-pair copper cable to restart the initialization process.
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600. YES
• Proceed to step 5.
5. Is the DPX/COLL (duplex/collision) LED illuminated? YES
• The media converter has selected full-duplex for the copper link.
• If this is not the correct mode, disconnect and reconnect the twisted-
pair copper cable to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
7
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Pkwy, Minneapolis MN 55344 U.S.A.
Model: J/GE-CF-01 Series Media Converters
Part Number(s): J/GE-CF-01(SX), J/GE-CF-01(LX1), J/GE-CF-01(LX2),
J/GE-CF-01(LX6), J/GE-CF-01(LX100), J/GE-CF-01(LX101)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the J/GE-CF-01 to which this declaration
refers is in conformity with the following standards:
CISPR 22:1993; EN 55022:1994 +A1:1995 +A2:1997 Class A; EN 55024:1998; EN61000-2-3:1995; EN61000-3-3:1995 FCC Part 15 Subpart B; 21 CFR subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
January, 2008
Stephen Anderson, Vice President of Engineering Date
Troubleshooting -- Continued
NO
• The media converter has selected half-duplex for the copper link.
• If this is not the correct mode, disconnect and reconnect the twisted­pair copper cable to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
6. Is the DPX/COLL (duplex/collision) LED flashing? YES
• There is a collision along the twisted-pair copper link.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Contact Transition Networks
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
Send an e-mail anytime to our technical support staff at: techsupport@transition.com
Transition Networks, 6475 City West Pkwy, Minneapolis, MN 55344, U.S.A. telephone: 952-941-7600, toll free: 800-526-9267, fax: 952-941-2322
Page 5
Compliance Information
CISPR22/EN55022 Class A + EN55024; CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations This digital apparatus does not exceed the Class A limits for radio
noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures.
Achtung ! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll is der Benutzer für Gegenmaßnahmen verantwortlich.
Attention ! Ceci est un produit de Classe A. Dans un environment domestique, ce produit
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic or mechanical - without written
permission from Transition Networks. Printed in the U.S.A.
33319.D
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.
Loading...