Transition Networks E-TBT-FRL-05 series Ethernet™ 10Base-T to 10Base-FL Media Converters connect 10 Mb/s twisted-pair copper cable to 10 Mb/s fiber-optic cable.
* Typical maximum cable distance. (Actual distance is dependent upon the physical characteristics of the network installation.)
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Technical Specifications . . . . . . . .4
Cable Specifications . . . . . . . . . . .5
Fault Isolation and Correction . . .6
Contact Us . . . . . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8
Part Number Port One - Copper Port Two - Duplex Fiber-Optic E-TBT-FRL-05
E-TBT-FRL-05(HT)
RJ-45, 10Base-T 100 m (328 ft)*
ST, 10Base-FL, 850 nm multimode 2 km (1.2 miles)*
E-TBT-FRL-05(SC) E-TBT-FRL-05(SCHT)
RJ-45, 10Base-T 100 m (328 ft)*
SC , 10Base-FL, 850 nm multimode 2 km (1.2 miles)*
E-TBT-FRL-05(MT) RJ-45, 10Base-T
100 m (328 ft)*
MT-RJ , 10Base-FL, 850 nm multimode 2 km (1.2 miles)*
E-TBT-FRL-05(SM) RJ-45, 10Base-T
100 m (328 ft)*
ST, 10Base-FL, 1300 nm singlemode 20 km (12.4 miles)*
E-TBT-FRL-05(SMHT) RJ-45, 10Base-T
100 m (328 ft)*
ST, 10Base-FL, 1300 nm singlemode 2 km (1.2 miles)*
E-TBT-FRL-05(L) RJ-45, 10Base-T
100 m (328 ft)*
ST, 10Base-FL, 1300 nm multimode 5 km (3.1 miles)*
E-TBT-FRL-05(LH) RJ-45, 10Base-T
100 m (328 ft)*
ST, 10Base-FL, 1300 nm multimode 40 km (24.9 miles)*
E-TBT-FRL-05(XC) E-TBT-FRL-05(XCHT)
RJ-45, 10Base-T 100 m (328 ft)*
SC, 10Base-FL, 1300 nm singlemode 20 km (12.4 miles)*
E-TBT-FRL-05(XLHT) RJ-45, 10Base-T
100 m (328 ft)*
SC, 10Base-FL, 1300 nm singlemode 50 km (31.1 miles)*
2
Tech Support: 1-800-260-1312 Int’l: 00-1-952-941-7600 7am-6pm CST (GMT-6:00)
E-TBT-FRL-05
Install the Cable
FIBER
1. Locate or build 10Base-FL compliant fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the J/E-CF-02 Media Converter as described:
• Connect the male TX cable connector the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector the female RX port.
• Connect the male RX cable connector to the female TX port.
Connect the fiber cable to the Media Converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
Optional Accessories: (sold separately)
INSTALLATION
Set the LinkAlert™ Switch
The LinkAlert™ switch is located on the side of the Media Converter. Use a small flatblade screwdriver or a similar device to set the recessed switches (see page 3).
LEFT Enables the LinkAlert™ function RIGHT Disables the LinkAlert™ function.
Part Number Description
E-MCR-03 12-Slot Media Converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
WMBS Optional Wall Mount Brackets
Length: 3.2 in. (81 mm), Fits converter length: 3.9 in. (99 mm)
SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
SPS-1872-CC Optional External Power Supply; 18-72VDC Piggy-Back
Output: 12.6VDC, 1.0 A
LinkAlertTM Disabled
LinkAlert
TM
Enabled
Page 2
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
3
Power the Media Converter
AC
1. Install the power adapter cord to the back of the Media Converter.
2. Connect the power adapter plug to AC power.
3. Verify that the Media Converter is powered by observing the illuminated LED power indicator light.
DC
Consult the User’s Guide for the Transition Networks SPS1872-xx DC External Power Suppy for powering the Media Converter.
INSTALLATION -- Continued
COPPER
1. Locate or build 10Base-T compliant copper cables with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the J/E-CF-02 Media Converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.).
RJ-45 port
on the Media
Converter
RJ-45 port
on the other device
(switch, work station, etc.)
Features
AutoCross
The AutoCross™ feature allows either straight-through (MDI) or crossover (MDI-X) cables to be used when connecting to 10Base-TX devices (hubs, transceivers, NICs, etc.). AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up, regardless of the cable configuration. (Requires no operator intervention).
LinkAlert
Because most Ethernet™ technologies are unable to recognize downlink faults, a failed link may appear normal to network management; requiring unnecessary troubleshooting. When the LinkAlert™ feature is activated, the media converter passes copper-side link faults to the fiber side and fiber-side links to the copper-side. This feature allows all faults to be detected by network management.
NOTE: An enable/disable switch allows the LinkAlert™ feature to be disabled. LinkAlert™ may interfere with the Auto-Negotiation feature of other devices in networks where there are two media converters installed in series.
4
Tech Support: 1-800-260-1312 Int’l: 00-1-952-941-7600 7am-6pm CST (GMT-6:00)
E-TBT-FRL-05
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3™
Data Rate 10 Mb/s
Case Dimensions 3.9" x 3.0" x 1.0" (99mm x 76mm x 25mm)
Shipping Weight 2 lbs (0.9 kg)
Power Supply 9VDC, 500 mA (minimum) DC Output minimum output regulation: 5%
Connector: 2.1mm barrel, center pin positive
MTBF 54,337 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
131,255 hours (Bellcore7 V5.0)
Environment Operating Temperature: 0 to 50°C (32° to 122° F )
E-TBT-FRL-05, E-TBT-FRL-05(SC), E-TBT-FRL-05(SM), E-TBT-FRL-05(L), E-TBT-FRL-05(MT), E-TBT-FRL-05(LH), E-TBT-FRL-05(XC)
Operating Temperature: -25 to 70°C (-13° to 158° F )
E-TBT-FRL-05(HT), E-TBT-FRL-05(SCHT), E-TBT-FRL-05(SMHT), E­TBT-FRL-05(XCHT), E-TBT-FRL-05(XLHT)
Storage TEmperature: -20° to 85°C (-4° to 185°F) Humidity: 5-95%, non condensing Altitude: 0-10,000 feet
Warranty Lifetime
OPERATION
After installation, the Media Converter should function without operator intervention. Use the status LEDs to monitor Media Converter operation in the network.
Link (Fiber) Steady LED indicates good 10BASE-FL link and normal operation.
Dark LED indicates lack of power OR downed 10BASE-FL link.
RX (Fiber) Flashing LED indicates data reception on 10BASE-FL link.
Link (RJ-45) Steady LED indicates good 10BASE-T link and normal operation.
Dark LED indicates lack of power OR downed 10BASE-T link.
RX (RJ-45) Flashing LED indicates data reception on 10BASE-T link.
Pwr Steady LED indicates connection to external AC power.
Fiber Connectors
RX
TX
Link
RX
Link
RX
Pwr
RJ-45 Connector
10BASE-T
10BASE-FL
Page 3
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
5
CABLE SPECIFICATIONS
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate: <10-9 Singlemode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
E-TBT-FRL-05, E-TBT-FRL-05(SC) E-TBT-FRL-05(MT) 850 nM multimode
Fiber Optic Transmitter Power: min: -20.0 dBm max: -10.0 dBm Fiber Optic Receiver Sensitivity: min: -32.0 dBm max: -8.0 dBm Link Budget: 12.0 dB
E-TBT-FRL-05(HT), E-TBT-FRL-05(SCHT) 850 nM multimode Fiber Optic Transmitter Power: min: -20.0 dBm max: -10.0 dBm Fiber Optic Receiver Sensitivity: min: -32.0 dBm max: -10.0 dBm Link Budget: 12.0 dB
E-TBT-FRL-05(L) 1300 nM multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -10.0 dBm Fiber Optic Receiver Sensitivity: min: -34.0 dBm max: -8.0 dBm Link Budget: 15.0 dB
E-TBT-FRL-05(SM), E-TBT-FRL-05(XC) 1300 nM singlemode Fiber Optic Transmitter Power: min: -27.0 dBm max: -8.0 dBm Fiber Optic Receiver Sensitivity: min: -34.0 dBm max: -8.0 dBm Link Budget: 7.0 dB
E-TBT-FRL-05(SMHT) 850 nM multimode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -38.0 dBm max: -8.0 dBm Link Budget: 23.0 dB
E-TBT-FRL-05(XCHT) 1300 nM singlemode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -38.0 dBm max: -8.0 dBm Link Budget: 23.0 dB
E-TBT-FRL-05(LH) 1300 nM singlemode Fiber Optic Transmitter Power: min: -17.0 dBm max: -10.0 dBm Fiber Optic Receiver Sensitivity: min: -34.0 dBm max: -8.0 dBm Link Budget: 18.0 dB
E-TBT-FRL-05(XLHT) 1300 nM singlemode Fiber Optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber Optic Receiver Sensitivity: min: -38.0 dBm max: -8.0 dBm Link Budget: 33.0 dB
Copper Cable
Category 3: Required
Gauge 24 to 22 AWG Attenuation 11.5 dB/100m @ 5-10 MHz Maximum Cable Distance 100 meters
• Straight-Through OR Crossover cable may be used. (Do not use flat or silver satin wire.)
• Shielded Twisted-Pair (STP) OR Unshielded Twisted-Pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet™ network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins:
(e.g., blue/white & white/blue, orange/white & white/orange, etc.)
6
Tech Support: 1-800-260-1312 Int’l: 00-1-952-941-7600 7am-6pm CST (GMT-6:00)
E-TBT-FRL-05
FAULT ISOLATION and CORRECTION
If the Media Converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the P(ower) LED on the Media Converter illuminated? NO
• Is the power adapter the proper voltage and frequency for AC outlet?
NOTE: Refer to “Power Supply Requirements” on page 7.
• Is the power adapter properly installed in the Media Converter and in
the outlet?
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 2.
2. Is the 10BASE-T Link LED illuminated? NO
• Check the twisted-pair cables for proper connection.
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 3.
3. Is the 10BASE-FL Link LED illuminated? NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the Media Converter are
connected to RX and TX ports, respectively, on the other device.
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 4.
4. Is the 10BASE-T RX LED illuminated? NO
• Disconnect and reconnect the 10BASE-T cable to restart the
initialization process.
• Restart the attached device to restart the initialization process.
• Contact Technical Support: (800) 260-1312.
YES
• Proceed to step 5.
5. Is the 10BASE-FL RX LED illuminated? NO
• Disconnect and reconnect the 10BASE-FL cable to restart the
initialization process.
• Restart the attached device to restart the initialization process.
• Contact Technical Support: (800) 260-1312.
YES
• Contact Technical Support: (800) 260-1312.
Page 4
techsupport@transition.com -- Select the “Transition Now” Link for a Live Web Chat
7
CONTACT US
Technical Support
Technical support is avialable 7:00 AM - 6:00 PM CST (GMT -6:00) US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition NOW
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition NOW link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, USA telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: E-TBT-FRL-05 Series Media Converter Part Number: E-TBT-FRL-05, E-TBT-FRL-05(SC), E-TBT-FRL-05(SM), E-TBT-FRL-05(L),
E-TBT-FRL-05(MT), E-TBT-FRL-05(LH), E-TBT-FRL-05(XC), E-TBT-FRL-05(HT), E-TBT-FRL-05(SCHT), E-TBT-FRL-05(SMHT), E-TBT-FRL-05(XCHT), E-TBT-FRL-05(XLHT)
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
E-TBT-FRL-05
to which this declaration refers is in
conformity with the following standards. EN 55022:1994; EN 55024:1998; FCC Part 15 Class A; EN 60950 A4:1997; UL 1950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_October 17, 2001_____
Stephen Anderson, Vice-President of Engineering Date
COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR22/EN55022 Class A + EN55204 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2003 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks.
Printed in the U.S.A.
33237.C
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Loading...