E-TBT-FRL-04 IN THE NETWORK
Use the E-TBT-FRL-04 media converter (or two E-TBT-FRL-04 media converters
in pairs) to connect a workstation to a remote hub or to connect two hubs,
switches, or workstations.
NOTE: Maximum Number of Nodes: 2 nodes
The AutoCross™ feature allows either straight-through or crossover cables to be
used when connecting to 10BASE-T devices, such as hubs, transceivers, or
network interface cards (NICs). AutoCross™ determines the characteristics of
the cable connection and automatically configures the unit to link up to straightthrough or to crossover cable.
The LinkALERT™ feature allows the E-TBT-FRL-04 media converter to pass
10BASE-T side link faults to the 10BASE-FL side and to pass 10BASE-FL side link
faults to the 10BASE-T side. NOTE: An enable/disable switch allows the network
administrator to disable LinkALERT™ in the case of a network with back-toback media converter installation in which Autonegotiation from other sources
does not work properly.
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3
Case Dimensions 3.8" x 2.4" x 1.0" (97mm x 61mm x 25mm)
Environment Temperature 0 to 50°C (32° to 122° F )
Storage Temperature -20 to 85°C
Humidity 5-95%, non condensing
Altitude 0-10,000 feet
Power Supply Requirements
Replace power supply with only the equivalent input
rating (see below) and output rating (regulated 9VDC at 500 mA).
TN PN Requirement Location
3517 240 volts, 50 hertz United Kingdom
3516 230 volts, 50 hertz Europe
3518 120 volts, 60 hertz USA/Canada/Mexico
3514 100 volts, 50-60 hertz Japan
3515 240 volts, 50 hertz Australia
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA
Model: E-TBT-FRL-04 Series 10BASE-T/10BASE-FL Media Converter
Part Number: E-TBT-FRL-04, E-TBT-FRL-04(SC), E-TBT-FRL-04(SM), E-TBT-FRL-04(L),
E-TBT-FRL-04(MT), E-TBT-FRL-04(LH), E-TBT-FRL-04(XC)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the E-TBT-FRL-04 to which this declaration refers is in
conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992;
EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_July 7, 1999_____
Stephen Anderson, Vice-President of Engineering Date