Transition Networks E-TBT-FRL-03(L), E-TBT-FRL-03(MT), E-TBT-FRL-03(SC), E-TBT-FRL-03(SM), E-TBT-FRL-03(XC) User Manual

...
Page 1
COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l’utilsateur de prende les measures spécifiques appropriées
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Printed in the U.S.A. 33032.F
The TRANSITION Networks E-TBT-FRL-03 10BASE-T/10BASE-FL media converters connect either half­duplex or full-duplex, unshielded or shielded 10BASE­T twisted-pair copper to either half-duplex or full-duplex 10BASE-FL multimode fiber.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Minneapolis, MN 55344 USA
10BASE-T/10BASE-FL
Media Converters
E-TBT -FRL-03, E-TBT -FRL-03(SC), E-TBT -FRL-03(SM),
E-TBT-FRL-03(L), E-TBT-FRL-03(MT), E-TBT-FRL-03(XC)
USER’S GUIDE
E-TBT-FRL-03
Provides an RJ-45 unshielded twisted pair 10BASE-T connector and a set of RX (receive) and TX (transmit) ST 10BASE-FL 850nm multimode fiber connectors.
E-TBT-FRL-03 (SC)
Provides an RJ-45 unshielded twisted pair 10BASE-T connector and a set of RX (receive) and TX (transmit) SC 10BASE-FL 850nm multimode fiber connectors.
E-TBT-FRL-03(SM)
Provides an RJ-45 unshielded twisted pair 10BASE-T connector and an RX (receive) and TX (transmit) ST 10BASE­FL 1300nm singlemode fiber connector.
E-TBT-FRL-03(L)
Provides an RJ-45 unshielded twisted pair 10BASE-T connector and a set of RX (receive) and TX (transmit) ST 10BASE-FL 1300nm multimode fiber connectors.
E-TBT-FRL-03(MT)
Provides an RJ-45 unshielded twisted pair 10BASE-T connector and an RX (receive) and TX (transmit) MT-RJ 10BASE-FL 850nm multimode fiber connector.
E-TBT-FRL-03(XC)
Provides an RJ-45 unshielded twisted pair 10BASE-T connector and an RX (receive) and TX (transmit) SC 10BASE­FL 1300nm singlemode fiber connector.
E-TBT-FRL-03 in the Network . . .2
Installation . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . .4
Fault Isolation and Correction . .5
Cable Specifications . . . . . . . . . .6
Technical Specifications . . . . . . .7
Compliance Information . . . . . . .8
Multimode Fiber
UTP/STP Copper
Page 2
E-TBT-FRL-03 IN THE NETWORK
Use the E-TBT-FRL-03 media converter (or two E-TBT-FRL-03 media converters in pairs) to connect a workstation to a remote hub or to connect two hubs.
NOTE: Maximum cable distances apply ONLY to full duplex installations.
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3 Case Dimensions 3.8" x 2.4" x 1.0" (97mm x 61mm x 25mm) Environment Temperature: 0-50°C (32° to 122° F )
Humidity 5-95%, non condensing Altitude 0-10,000 feet
Power Supply Requirements
Replace power supply with only the equivalent input
rating (see below) and output rating (regulated 9VDC at 500 mA).
TN PN Requirement Location
3517 240 volts, 50 hertz United Kingdom 3516 230 volts, 50 hertz Europe 3518 120 volts, 60 hertz USA/Canada/Mexico 3514 100 volts, 50-60 hertz Japan 3515 240 volts, 50 hertz Australia
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: E-TBT-FRL-03 Series Copper-to-Fiber Media Converter Part Number: E-TBT-FRL-03, E-TBT-FRL-03(SC), E-TBT-FRL-03(SM),
E-TBT-FRL-03(L), E-TBT-FRL-03(MT), E-TBT-FRL-03(XC)
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the E-TBT-FRL-03 to which this declaration refers is in
conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_July 7, 1999_____
Stephen Anderson, Vice-President of Engineering Date
2 kilometers - 850 nM multimode
100 meters
100 meters
20 kilometers - 1300 nM singlemode
5 kilometers - 1300 nM multimode
Page 3
CABLE SPECIFICATIONS
The physical characteristics of the media cable must meet or exceed IEEE 802.3 specifications.
Fiber Cable
850NM MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: Minimum: -15 dBm Fiber Optic Receiver Sensitivity: Minimum : -33 dBm
Bit error rate: 10
-10
Maximum Cable Distance: 2 kilometers (6,600 feet
1300NM MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: Minimum: -17 dBm Fiber Optic Receiver Sensitivity: Minimum: -35 dBm
Bit
error rate: 10
-9
Maximum Cable Distance: 5 kilometers (16,500 feet)
1300NM SINGLEMODE (ST)
Fiber Optic Cable Recommended: 9/125 micron single mode fiber Fiber Optic Transmitter Power: Minimum: -27 dBm Fiber Optic Receiver Sensitivity: Minimum: -36 dBm Bit error rate: 10
-10
Maximum Cable Distance: 20 kilometers (66,000 feet)
1300NM SINGLEMODE (SC)
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: Minimum: -15.5 dBm Fiber Optic Receiver Sensitivity: Minimum : -36.9 dBm
Bit error rate: 10
-10
Maximum Cable Distance: 20 kilometers (66,000 feet)
Copper Cable and Connector
Category 3 or better twisted-pair copper wire is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
CATEGORY 3:
Gauge 24 to 22 AWG Attenuation £11.5 dB/100m @ 5-10 MHz
Maximum Number of Nodes 2 nodes Maximum Cable Distance 100 meters (200 meters with better cable RJ-45 Pin-outs Pin 1=TD+, Pin 2=TD-,
Pin 3=RTD+, Pin 4=RD-
Twisted pair connection requires two active pairs configured as straight through. The two active pairs in an Ethernet network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pairs.
INSTALLATION
Set MDI/MDI-X Switch
NOTE: Straight-through/crossover 10BASE-T requirements are satisfied using the MDI/MDI-X switch with straight-through cable. See page 6 for cable configurations.
Using small flatblade screwdriver or similar tool and referring to label at front of media converter, set MDI/MDI-X switch position for site installation.
10BASE-T cable connections between a hub and the media converter require the MDI/MDI-X switch to be set to MDI. 10BASE-T cable connections between the media converter and a terminal, transceiver or NIC require the switch to be set to MDI-X
Install Cable
NOTE: See page 6 for cable specifications.
COPPER
NOTE: KEEP TWISTED PAIR RUNS AS SHORT AS POSSIBLE.
Locate or build 10BASE-T-compliant cables with straight-through or crossover configuration and with male RJ-45 plug connectors at both ends.
Connect male RJ-45 plug connector at one end of cable to media converter RJ-45 jack connector.
Connect male RJ-45 plug connector at other end of cable to 10BASE-T terminal device RJ-45 jack connector (using straight­through cable configuration) or to 10BASE-T hub RJ-45 jack connector (using crossover cable configuration).
FIBER
Locate or build 10BASE-FL-compliant fiber cable with male two­stranded TX to RX connectors at both ends.
Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on media converter.
Connect male TX and RX cable connectors at other end of cable to RX and TX connectors of 802.3 compliant fiber device.
Connect to Power
Install power adapter cord at back of media converter.
Connect power adapter plug to AC power.
Verify that media converter is powered by observing illuminated
LED(s).
Twisted Pair #1
Twisted Pair #2
Straight Through Cable
MDI position
MDI-X position
Page 4
OPERATION
After installation, the media converter should function without operator intervention.
Status LEDs
Use the status LEDs to monitor media converter operation in the network.
Link
(near 10BASE-FL connector) Steady green LED indicates good
10BASE-FL link and normal operation. Dark LED indicates lack of power OR downed 10BASE-FL
link.
RX (Receive -
near 10BASE-FL connector) Flashing green LED
indicates data reception on 10BASE-FL link.
Link
(near 10BASE-T connector) Steady green LED indicates good
10BASE-T link and normal operation. Dark LED indicates lack of power OR downed 10BASE-T
link.
RX (Receive -
near 10BASE-T connector) Flashing green LED
indicates data reception on 10BASE-T link.
P(o)w(e)r Steady green LED indicates connection to external AC
power.
FAULT ISOLATION and CORRECTION
If the media converter fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the P(ower) LED on the media converter illuminated? NO
Is the power adapter the proper voltage and frequency for AC
outlet? NOTE: Refer to Power Supply Requirements on page 7.
Is the power adapter properly installed in the media converter and
in the outlet?
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Proceed to step 2.
2. Is the green 10BASE-T Link LED illuminated? NO
Check twisted pair cables for proper connection.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Proceed to step 3.
3. Is the green 10BASE-FL Link LED illuminated? NO
Check fiber cables for proper connection.
Verify that TX and RX cables on media converter are connected to
RX and TX ports, respectively, on other device.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Proceed to step 4.
4. Is the amber 10BASE-T RX LED illuminated? NO
Restart the workstation to restart the initialization process.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Proceed to step 5.
5. Is the amber 10BASE-FL RX LED illuminated? NO
Restart the workstation to restart the initialization process.
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
YES
Contact Technical Support: (800) 260-1312/(800) LAN-WANS.
10BASE-T
ST Connectors
RX
TX
Link
RX
Link
RX
Pwr
(Fiber)
Link
RX
Pwr
RX
Link
(RJ-45)
RJ-45 Connector
10BASE-T
10BASE-FL
Loading...