Transition Networks J/RS232-CF-01(SC), J/RS232-TF-01(SC), SPS-1872-CC, SPS-1872-SA, E-MCR-04 User Manual

...
Page 1
User’s Guide
J/RS232-xx-01
Stand-Alone Media Converter
• Just Convert-It
• RS-232 to Fiber
Transition Networks J/RS232-xx-01 series media converter connects RS­232 cable to fiber-optic cable at data rates up to 120 kB/s asynchronous.
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Cable Specifications . . . . . . . . . . .5
Technical Specifications . . . . . . . .6
Troubleshooting . . . . . . . . . . . . . .7
Compliance Information . . . . . . . .8
Part Number Port One - RS-232 Port Two - Fiber-Optic
J/RS232-CF-01 RS-232 (female, DCE)
15 m (50 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
J/RS232-CF-01(SC) RS-232 (female, DCE)
15 m (50 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
J/RS232-TF-01 RS-232 (male, DTE)
15 m (50 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
J/RS232-TF-01(SC) RS-232 (male, DTE)
15 m (50 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network installation.
Optional Accessories: (sold separately)
Part Number Description SPS-1872-SA Optional External Power Supply; 18-72VDC Stand-Alone
Output: 12.6VDC, 1.0 A
SPS-1872-CC Optional External Power Supply; 18-72VDC Piggy-back;
Output: 12.6VDC, 1.0 A
E-MCR-04 12-Slot Media Converter Rack (includes universal internal power
supply) 17 x 15 x 5 in. (432 x 381 x 127 mm)
WMBS Optional Wall Mount Brackets
Length: 3.2 in. (81 mm), Fits converter length: 3.9 in. (99 mm)
WMBV Optional Vertical Mount Bracket; 5.0 in. (127 mm) WMBD Optional DIN Rail Mount Bracket; 5.0 in. (127 mm) WMBD-FS Optional DIN Rail Mount Bracket (flat, small); 3.1in. (79 mm)
Page 2
2
J/RS232-xx-01
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation
DTE and DCE
Each J/RS232-xx-01 model is configured as a:
DTE (Data Terminal Equipment) with a male RS-232 port, or a
DCE (Data Communication Equipment) with a female RS-232 port.
So, the type of media converter and the application in which it is used determines which type of RS-232 cable is needed:
Straight-through configuration cable, or
Null-modem configuration cable.
NOTE: The J/RS232-xx-01 only uses pins 2, 3 and 5.
Install the RS-232 Cable
Sections 1-4 (below and on page 3) illustrate which type of RS-232 cable should be used for the various applications:
1. J/RS232-CF-01 Media Converter / DCE Device
Use a null-modem RS-232 cable with a male connector when connecting a J/RS232-CF-01 or J/RS232-CF-01(SC) media converter to a DCE device.
J
-RS232-CF-01 or J-RS232-CF-01(SC)
(DCE configuration with a female RS-232 port)
DCE device
null-modem RS-232 cable with a male connector
9
8
7
6
6
7
8
9
1
5
4
3
2
5
1
2
3
4
Null-modem configuration cable
with handshaking signaling
Straight-through configuration cable
with handshaking signals
9
8
7
6
9
8
7
6
1
5
4
3
2
1
5
4
3
2
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
2. J/RS232-TF-01 Media Converter / DCE Device
Use a straight-through RS-232 cable with a female connector when connecting a J/RS232-TF-01 or J/RS232-TF-01(SC) media converter to a DCE device.
3. J/RS232-CF-01 Media Converter / DTE Device
Use a straight-through RS-232 cable with a male connector when connecting a J/RS232-CF-01 or J/RS232-CF-01(SC) media converter to a DTE device.
4. J/RS232-TF-01 Media Converter / DTE Device
Use a null-modem RS-232 cable with a female connector when connecting a J/RS232-TF-01 or J/RS232-TF-01(SC) media converter to a DTE device.
J
-RS232-TF-01 or J-RS232-TF-01(SC)
(DTE configuration with a male RS-232 port)
DCE device
straight-through RS-232 cable with a female connector
J
-RS232-CF-01 or J-RS232-CF-01(SC)
(DCE configuration with a female RS-232 port)
DTE device
straight-through RS-232 cable with a male connector
J
-RS232-TF-01 or J-RS232-TF-01(SC)
(DTE configuration with a male RS-232 port)
DTE device
null-modem RS-232 cable with a female connector
Page 3
4
J/RS232-xx-01
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation -- Continued
Install the Fiber Cable
1. Locate or build fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the first J/RS232-xx-01 media converter as described:
• Connect the male TX cable connector to the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other J/RS232-xx-01 media converter as described:
• Connect the male TX cable connector to the female RX port.
• Connect the male RX cable connector to the female TX port.
Connect the fiber cable to the first media converter as shown.
Connect the fiber cable
to the second media
converter, as shown
RX
TX
RX
TX
Power the Media Converter
NOTE: The external power supply provided with this product is UL listed by
the power supply’s manufacturer.
• Connect the barrel connector on the power adapter to the media converter’s power port (located on the back of the media converter).
• Connect the power adapter plug to AC power. Verify that the media converter is powered by observing the illuminated LED power indicator light. (For DC power see the SPS1872-xx DC external power supply.)
Fiber
Fiber
RS-232
RS-232
RX
TX
PWR
RX
FL
Operation
Use the status LEDs to monitor the media converter operation in the network.
RX On = A link has been established with the RS-232 connector.
Flashing = The RS-232 connector is receiving data.
FL On = A link has been established with the fiber connector.
PWR On = The media converter is connected to external power.
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
RS-232 Cable
Gauge: 24 to 22 AWG Maximum data rate: 120 Kb/s, asynchronous Maximum Cable Distance: 15 m (50 ft)
RS-232 Signals:
NOTE: The J/RS232-xx-01 only uses pins 2, 3 and 5.
Receive Data Transmit Data
Signal Groun
d
1
5
4
3
2
9
8
7
6
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate: <10-9 Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
J/RS232-CF-01 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
J/RS232-CF-01(SC) 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
J/RS232-TF-01 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
J/RS232-TF-01(SC) 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC-825/CDRH standards and complies with 21 CFR1040.10 and 21CFR1040.11.
Page 4
6
J/RS232-xx-01
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Technical Specifications
For use with Transition Networks Model J/RS232-xx-01 or equivalent
Data Rate 120 Kb/s, asynchronous
Dimensions 3.0" x 3.9" x 1.0" (76 mm x 99 mm x 25 mm)
Shipping Weight 6 oz. (181 g) (approximately)
Power Consumption 3 Watts
Power Supply 12 VDC, 0.5 A (North America)
12 VDC, 0.41 A (Europe, Japan, Latin America) 12 VDC, 1.25 A (N. Z., Australia, U.K., South Africa) (The external power supply provided with this product is UL listed by the power supply’s manufacturer.)
MTBF (approximate) 49,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
129,000 hours (Bellcore7 V5.0)
Environment Tmra*: 0 to 50°C (32° to 122°F )
Storage Temp: -15° to 65°C (5° to 149°F) Humidity: 5 to 95%, non condensing Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature.
The information in this user’s guide is subject to change. For the most up-to-date information on the J/RS232-xx-01 media converter, view the user’s guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into the beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
7
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the PWR (power) LED on the media converter illuminated? NO
• Is the power adapter the proper type of voltage and cycle frequency
for the AC outlet? (See “Technical Specifications” on page 6.)
• Is the power adapter properly installed in the media converter and in
the AC outlet?
• Does the grounded AC outlet provide power?
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the RX (RS-232) LED illuminated? NO
• Check the RS-232 cable for proper connection.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
Proceed to step 3.
3. Is the FL (fiber) LED illuminated? NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the media converter are
connected to the RX and TX ports, respectively, on the remote media converter.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
Contact Us
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Transition Networks; 6475 City West Parkway; Minneapolis, MN 55344, USA telephone: 952-941-7600; toll free: 800-526-9267; fax: 952-941-2322
Page 5
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical ­without written permission from Transition Networks. Printed in the U.S.A.
Compliance Information
CISPR22/EN55022 Class A + EN55024; CE Mark FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations Warning
This is a Class A product. In a domestic environment this product may cause
radio interference in which case the user may be required to take adequate measures.
Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können
bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich.
Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit
risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: J/RS232-xx-01 Series Media Converter Part Number: J/RS232-CF-01, J/RS232-CF-01(SC),
J/RS232-TF-01, J/RS232-TF-01(SC)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the J/RS232-xx-01 to which this declaration refers
is in conformity with the following standards.
CISPR 22:1998; EN 55022:1998 Class A; EN 55024:1998; FCC Part 15 Subpart B; 21 CFR Subpart J
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_August 4, 2003_____
Stephen Anderson, Vice-President of Engineering Date
33285.C
Loading...