Transition Networks E-MCR-02 User Manual

Page 1
MEDIA CONVERTER RACK
TECHNICAL SPECIFICATIONS
Case dimensions 17.0" x 13.0" x 4.5" (432mm x 330mm x 114mm) Power Requirements NOTE: Ensure that available power circuits are not overloaded.
Ensure that rack mounting equipment is reliably grounded.
Input Voltage 85-264 VAC Input Frequency 47-63 Hz
Power Cord TN P/N Requirement Location
3344 120 volts, 60 Hz USA/Canada 3344 100 volts, 50-60 Hz Japan 3347 230 volts, 50 Hz Europe 3348 240 volts, 50 Hz Australia 3349 240 volts, 50 Hz United Kingdom
Environment Temperature: 0-50°C (32° to 122° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Lifetime
The Transition Networks Media Converter Rack provides space and power in a rack-mountable chassis for twelve (12) separate and independent Transition Networks media converters, each with power requirements ranging from 9VDC to 12VDC.
The Media Converter Rack is designed ONLY for installation of media converters designed and built by Transition Networks that have both media input connector and media output connector located on the same side of the media converter, opposite the power input connector.
The Transition Networks Media Converter Rack is shipped with attached feet for installation on any well-ventilated table-top or shelf. Optionally, the Media Converter Rack can be installed in a standard 19-inch rack, using installation brackets and attachment screws provided.
Media Converter Rack
E-MCR-02
USER’S GUIDE
Compliance Information
Safety: UL 1950 and EN60950 C-UL Listed (Canada)
Emissions: FCC Class A, CISPR 22 Class A, EN55022 Immunity: EN50082, IEC 801-2,3,4
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33107.B
Minneapolis, MN 55344 USA
Page 2
INSTALLATION
WARNING: Carefully mount the Media Converter Rack in a standard 19-inch rack to prevent creating a hazardous condition due to uneven mechanical loading. Failure to observe this warning could allow the Media Converter Rack to fall, resulting in injury to personnel and/or equipment damage.
CAUTION: Do not use the Media Converter Rack chassis to provide earth ground for any 10BASE-2 cable shield connected to any installed media con­verter. Failure to observe this caution could cause the Media Converter Rack and all installed media converters to fail.
Optionally Install E-MCR-02 in 19-inch Site Rack
NOTE: Mounting brackets provide two (2) sets of mounting holes, located one inch apart, that allow site-selection of flush or recessed installation.
1 Attach mounting brackets to E-MCR-02:
• Locate two (2) mounting brackets and four (4) screws (
PROVIDED) for
each Media Converter Rack to be installed.
• Align each mounting bracket against side of Media Converter Rack so that selected Media Converter Rack installation holes are visible through mounting bracket installa­tion holes and so that bracket surface to be attached to 19-inch site rack is flush with front of Media Converter Rack.
• Using Phillips screwdriver, install two (2) screws through each mounting bracket into side of Media Converter Rack.
Attach E-MCR-02 to 19-inch site rack:
• Locate four (4) screws and optional clip-nuts (
NOT PROVIDED) for each
Media Converter Rack to be installed.
• Carefully align the Media Converter Rack at a level position between the 19-inch site rack mounting rails.
• Install two (2) screws through right front bracket into right site rack mounting rail and two (2) screws through left front bracket into left site rack mounting rail, using clip nuts to secure if necessary.
1
3
2
2 Install Media Converter(s) in E-MCR-02
• Align media converter within installation space at front of Media Converter Rack and carefully slide into place.
• Tighten thumb screw located on Media Converter Rack directly above media converter to secure.
3 Install Media Cables at Front of Media Converter(s)
• Refer to documentation that comes with media converter(s) to determine correct cable specifications and distances for each media converter.
• Connect input and output media cable at front of media converter(s).
4 Connect Media Converter(s) to Power
• Locate media converter power cord (shipped with connector secured in rubber grommet located above media converter installation slot).
• Remove media converter power connector from rubber grommet and install in power receptacle at back of media converter.
5 Power the Media Converter Rack
NOTE: Ensure that available power circuits are not overloaded and that rack mounting equipment is reliably grounded.
• Locate power receptacle, associat­ed fuse and power switch on power supply at Media Converter Rack back.
• Referring to power cord specifications on back page, verify that fuse is installed at correct setting for site installation. If not:
Use small, flatblade screw­driver to carefully open fuse receptacle, rotate fuse 180˚, re-install fuse, and close fuse receptacle.
• Connect female end of power cord to Media Converter Rack.
• Connect male end of power cord to external AC outlet.
• Set ON/OFF switch to “I”.
1
5
Fuse
ON
I 0
OFF
4
Rubber Grommet
Power Receptacle
Loading...