Transition Networks E-FX-HB-0800, E-FX-HB-1600, E-FX-HB-1600(SC), E-FL-HB-0800, E-FX-HB-0800(SC) User Manual

Page 1
Minneapolis, MN 55344 USA
100BASE-FX Fast Ethernet
Unmanaged Fiber Hub with TX or FX Uplink
E-FX-HB-1600, E-FX-HB-0800
USER’S GUIDE
The stackable, rack-mountable E-FX-HB-1600 and E-FX-HB-0800 series unmanaged Fast Ethernet
fiber hubs allow the network administrator to set up and to modify workgroups connected over fiber and to install an optional copper or fiber backbone uplink connection to the workgroups and/or optional connections for stacking up to five hubs.
E-FX-HB-1600, E-FX-HB-1600(SC)
The E-FX-HB-1600 hub provides sixteen (16) Fast Ethernet
ST OR SC fiber connections to terminal devices plus space for an optional copper or fiber backbone uplink and space for an optional stacking adapter.
E-FX-HB-0800, E-FX-HB-0800(SC)
The E-FX-HB-0800 hub provides eight (8) Fast Ethernet
ST OR SC fiber connections to terminal devices plus space for an optional copper or fiber backbone uplink and space for an optional stacking adapter.
BACKBONE UPLINK ADAPTERS Optional devices ordered separately that, when installed, provide one of the following Fast Ethernet
backbone uplink connections:
MA-FST
ST connector to multimode fiber
MA-FSC
SC connector to multimode fiber
MA-FSM
SC connector to singlemode fiber
MA-TX RJ-45 connector to twisted-pair copper, AutoCross™feature
STACKING ADAPTERS Optional
devices ordered separately that, when installed, allow stacking between E-FX­HB-xx00 hubs.
ACC-0200
Stacking adapter
ACC-0201
Stacking cable
E-FX-HB-xx00 in the Network . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .4
Operation . . . . . . . . . . . . . . . . . . . .11
Fault Isolation and Correction . . . .12
Cable Specifications . . . . . . . . . . . .14
Technical Specifications . . . . . . . . .15
Compliance Information . . . . . . . . .16
STAT
PWR
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
4
5
7
6
8
9
11
10
12
13
15
14
16
STAT
PWR
COL
100BASE-FX
1
2
3
4
5
6
7
8
ACT
GFT
BB
1
3
2
4
5
7
6
8
COMPLIANCE INFORMATION
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the users own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Achtung !
Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in weichen Fällen der Benutzer für entsprechende Gegenmaßnahmen werantwortlich ist.
Attention !
Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à lutilsateur de prende les measures spécifiques appropriées
VCCI Class 1 Compliance
This equipment is in the 1st Class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council For Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and/or industrial areas. When used in a residential area or in an adjacent area thereto, interference may be caused to radio and TV receivers, etc. Read the instructions for correct handling.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Printed in the U.S.A. 33122.A
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Page 2
E-FX-HB-xx00 IN THE NETWORK
Install one E-FX-HB-xx00 hub and use fiber cable to set up a workgroup by connecting the hub to terminal devices.
Install an optional backbone uplink adaptor at the back of the hub and use copper or fiber cable to connect the workgroup to a network backbone.
Install an optional expansion adaptor at the back of up to five (5) hubs and then use expansion adaptor cables to connect the hubs into a stack that functions as one Class A repeater.
TECHNICAL SPECIFICATIONS
Standards IEEE 802.3
Dimensions 17.25" x 8.5" x 1.7" (437 mm x 216 mm x 43 mm) Power
Input Range: 100 to 240 VAC at 50 or 60 Hz, 3.0 A maximum.
Rated at 40 watts maximum.
Environment Operating Temperature: 0° to 50°C (32° to 122° F )
Storage Temperature: -15° to 65°C (5° to 149° F ) Humidity 5% to 95%, non condensing Altitude 0 to 10,000 feet
Warranty Lifetime
DECLARATION OF CONFORMITY
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: E-FX-HB-xx00 Series Unmanaged Fiber Hub Part Number: E-FX-HB-1600, E-FX-HB-1600(SC), E-FX-HB-0800,
E-FX-HB-0800(SC)
Regulation: EMC Directive 89/336/EEC
Purpose: To declare that the E-FX-HB-1600 or E-FX-HB-0800 to which this
declaration refers is in conformity with the following standards.
EMC-CISPR 22: 1985 Class A; EN 55022: 1988 Class A; EN 50082-1:1992; EN 60950 A4:1997; IEC 801.2, IEC 801.3, and IEC 801.4; IEC 950
I, the undersigned, hereby declare that the equipment specified above conforms to the
above Directive(s) and Standard(s).
_November 10, 1999_____
Stephen Anderson, Vice-President of Engineering Date
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
to hub, switch, or router
to hub, switch, or router
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9 10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
Page 3
CABLE SPECIFICATIONS
Twisted Pair Cable and Connector Specifications
MA-TX Category 5 twisted-pair copper Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used. .
CATEGORY 5:
Gauge 24 to 22 AWG Attenuation 22.0 dB /100m @ 100 MHz Maximum Cable Distance*: 100 meters
Twisted pair connection requires two active pairs configured as straight-through OR as crossover. The two active pairs in an Ethernet network are pins 1 & 2 and pins 3 & 6. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
Fiber Cable
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber 50 / 125 µm multimode fiber
Bit error rate: 10
-11
E-FX-HB-xx00, MA-FST 1300 nM Fiber-optic Transmitter Power: min: -16.0 dBm max: -9.0 dBm Fiber-optic Receiver Sensitivity: min: -35.0 dBm max: -14.0 dBm Link Budget 19 dB Typical Maximum Cable Distance:* 2 kilometers E-FX-HB-xx00(SC), MA-FSC 1300 nM Fiber-optic Transmitter Power: min: -16.0 dBm max: -9.0 dBm Fiber-optic Receiver Sensitivity: min: -35.0 dBm max: -14.0 dBm Link Budget 19 dB Typical Maximum Cable Distance:* 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber Bit error rate: 10
-11
MA-FSM 1300 nM Fiber-optic Transmitter Power: min: -16.0 dBm max: -9.0 dBm Fiber-optic Receiver Sensitivity: min: -35.0 dBm max: -14.0 dBm Link Budget 19 dB Typical Maximum Cable Distance:* 20 kilometers
*Actual distance dependent upon physical characteristics of network installation.
Using the 512-Bit Rule
When configuring Fast Ethernet networks, use the 512-bit rule to determine masimum cable lengths for each half-duplex collision domair.
In a half-duplex network, maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet
collision domain. (Switches
and routers divide the network into separate Ethernet collision domains.) The 512-Bit Rule determines maximum distances by calculating the collision domain round-trip delay in bit-times.
To calculate a collision domain round-trip delay in bit-times, find the longest path between any two terminal devices in the collision domain. Calculate the round trip delay by multiplying the length of the cable (in meters) by the delay per meter (in bit-times (BT)), then take the sum of all cable delays plus station (DTE), repeater, and multi-port media converter port delays. If the result is less than or equal to 512 bit-times, the path is good.
to hub, switch or router
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
Collision Domain
Class II
Hub
30 meters TP
@ 1.11BT/meter
= 33.3BT
5 meters TP
@ 1.11BT/meter
= 5.55BT
= 140BT
Class I
Hub
= 140BT
20 meters TP
@ 1.11BT/meter
= 22.2BT
DTE=50BT
50.00BT
+22.20BT
+140.00BT
+5.55BT
+140.00BT
+33.30BT +50.00BT
___________
= 441.05BT
Switch
= 50BT
Class I repeater 140 BT Class II repeater 92 BT Class I TX/FX media converter 130 BT Class II TX/FX media converter 92 BT DTE (PC, switch, router) 50 BT 1 meter CAT.5 TP cable 1.11 BT 1 meter fiber cable 1 BT Fast Ethernet switch 50 BT
Cascade two repeater stacks by connecting fiber cable from a connector at the front of the first hub to a connector at the front of the second hub.
Crossover
1 2
3 6
Straight Through
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1 2
3 6
1 2
3 6
1 2
3 6
Page 4
INSTALLATION
Optionally Install Expansion Adapter
WARNING: Remove AC line cord from power source before installing expansion adaptor in E-FX-HB-xx00. Failure to observe this warning could result in personal injury or death.
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing Expansion Adapter in the E-FX-HB-xx00. Failure to observe this caution could result in damage to, and subsequent failure of, Expansion Adapter.
To install the expansion adapter in the E-FX-HB-xx00:
1. Locate expansion adapter plate at back of E-FX-HB-xx00.
2. Remove expansion adapter plate by using flatblade screwdriver to remove two (2) screws that secure expansion adapter plate to back of E-FX-HB-xx00.
NOTE: Retain screws for step 5. (Optionally discard expansion adapter plate.)
3. Carefully slide expansion adapter, component side up, into installation space revealed by removal of expansion adapter plate.
CAUTION: Do NOT force the connection. Failure to observe this
caution could result in equipment damage and subsequent failure.
4. Press component on expansion adapter securely against internal mating E-FX-HB-xx00 component until expansion adapter faceplate is flat against E-FX-HB-xx00 chassis.
5. Secure expansion adapter by installing retained screws through expansion adapter into E-FX-HB-xx00 chassis.
YES
Continue at step 7.
7. Is one (or more) of the 100BASE-FX STAT(us) LEDs illuminated continuously?
YES
Continue at step 10
NO
Continue at step 8.
8. Does one (or more) of the 100BASE-FX STAT(us) LEDs blink on and off?
YES
Check fiber cables for proper connection.
Verify that TX and RX cables on E-FX-HB-xx00 are connected to RX
and TX ports, respectively, on terminal device. (See page 9.)
Ensure that terminal device(s) is/are powered.
Contact Technical Support: (800) 260-1312.
NO
Continue at step 9.
9. Is one (or more) of the 100BASE-FX STAT(us) LEDs dark? YES
The port is (or ports are) partitioned; investigate the attached
terminal device(s).
Contact Technical Support: (800) 260-1312.
NO
Continue at step 10.
10. Is one (or more) of the 100BASE-FX ACT(ivity) LEDs illuminated?
YES
The port is (or ports are) operational and receiving data.
NO
Disconnect and reconnect the 100BASE-FX cable to restart the
initialization process.
Restart the terminal device(s) to restart the initialization process.
Contact Technical Support: (800) 260-1312.
Expansion Adapter Plate
Page 5
FAULT ISOLATION and CORRECTION
If the E-FX-HB-xx00 fails, isolate and correct the fault by determining the answers to the following questions and then taking the indicated action:
1. Is the P(o)W(e)R LED on the E-FX-HB-xx00 illuminated? NO
Is the power cord properly installed in the E-FX-HB-xx00 and in the
grounded AC outlet?
Does the grounded AC outlet provide power?
Contact Technical Support: (800) 260-1312.
YES
Continue at step 2.
2. Is a backbone uplink adapter installed at E-FX-HB-xx00 back? NO
Continue at step 7.
YES
Continue at step 3.
3. Is the B(ack)B(one) STAT(us) LED illuminated continuously? YES
Continue at step 7.
NO
Continue at step 4.
4. Does the B(ack)B(one) STAT(us) LED blink on and off? YES
Ensure that backbone uplink adapter is firmly connected.
Check backbone uplink cables for proper cabling and connection(s).
Ensure that device at remote end of network link is powered.
Contact Technical Support: (800) 260-1312.
NO
Continue at step 5.
5. Is the B(ack)B(one) STAT(us) LED dark? YES
The port is partitioned or isolated; investigate the device at the far
end of the link.
Contact Technical Support: (800) 260-1312.
NO
Continue at step 6.
6. Is the B(ack)B(one) ACT(ivity) LED illuminated? NO
Disconnect and reconnect the backbone cable to restart the
initialization process.
Restart the attached network device to restart the initialization
process.
Contact Technical Support: (800) 260-1312.
Optionally Install Backbone Uplink Adapter
WARNING: Remove AC line cord from power source before installing backbone uplink adaptor in E-FX-HB-xx00. Failure to observe this warning could result in personal injury or death.
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing backbone uplink adaptor in the E-FX-HB-xx00. Failure to observe this caution could result in damage to, and subsequent failure of, backbone uplink adaptor.
To install the backbone uplink adapter in the E-FX-HB-xx00:
1. Locate backbone uplink adapter plate at back of E-FX-HB-xx00.
2. Remove backbone uplink adapter plate by using flatblade screwdriver to remove two (2) screws that secure backbone uplink adapter plate to back of E-FX-HB-xx00.
NOTE: Retain screws for step 5. (Optionally discard backbone uplink adapter plate.)
3. Carefully slide backbone uplink adapter, component side up, into installation space revealed by removal of backbone uplink adapter plate.
CAUTION: Do NOT force connection. Failure to observe this caution
could result in equipment damage and subsequent failure.
4. Press component on backbone uplink adapter securely against internal mating E-FX-HB-xx00 component until backbone uplink adapter faceplate is flat against E-FX-HB-xx00 back.
5. Secure backbone uplink adapter by installing retained screws through backbone uplink adapter into E-FX-HB-xx00 chassis back.
Backbone Uplink Adapter Plate
Page 6
Install E-FX-HB-xx00 at Site
WARNING: During the site installation, handle the E-FX-HB-xx00 in such a way that the E-FX-HB-xx00 does not fall. Failure to observe this warning could result in injury to personnel and/or equipment damage.
NOTE: If E-FX-HB-xx00 is shipped with brackets installed, proceed to step 2. To install the E-FX-HB-xx00 in 19-inch rack cabinet:
1. Remove and retain two (2) screws located at front left side and front right side of E-FX-HB-xx00 chassis. Install right and left front brackets (provided) on chassis by installing two (2) retained screws through each bracket into chassis.
2. Carefully align E-FX-HB-xx00 between 19-inch rack mounting rails.
3. Install E-FX-HB-xx00 by installing two (2) screws through right front bracket into rack and two (2) screws through left front bracket into rack, using clip nuts (NOT provided) to secure, if necessary.
To install the E-FX-HB-xx00 on table or other flat surface:
NOTE: Rubber feet are provided.
1. Carefully turn E-FX-HB-xx00 to side.
2. Install four (4) rubber feet:
Separate rubber feet.
Remove protective paper
from adhesive surface on rubber foot.
Position and
secure each rubber foot as shown.
3. Return E-FX-HB-xx00 to upright position.
OPERATION
Use the status LEDs to monitor E-FX-HB-xx00 operation in the network.
HUB INDICATORS
P(o)W(e)R Steady LED indicates E-FX-HB-xx00 is
connected to external AC power.
COL(lision) Flashing LED indicates network collisions. G(lobal) F(ault) S(tatus) Steady LED indicates the presence of a
partitioned or isolated port. (A port is partitioned automatically after a collision occurs during 60 or more consecutive attempts to transmit to the port; a port is isolated if more then two consecutive false carrier events are received.)
NOTE: The hub unpartitions/unisolates the port when network traffic becomes normal. The GFS LED remains illuminated until the partition/isolation condition is corrected.)
B(ack)B(one) & 100BASE-FX INDICATORS
STAT(us) Steady LED indicates, for each port, a valid
link and no partition or isolation. Dark LED indicates, for each port, that port
is not linked, is isolated, or is partitioned.
ACT(ivity) Flashing LED indicates, for each port,
reception of data packet(s).
STAT
PWR
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
1
3
2
1
3
2
STAT
PWR
4
5
7
6
8
9
11
10
12
13
15
14
16
COL
ACT
100BASE-FX
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
ACT
STAT
GFT
BB
Page 7
Power the E-FX-HB-xx00
NOTE: When the hub is connected to an AC outlet supplying 100-240VAC at 50-60 Hz, the hub automatically powers ON
To power ON the E-FX-HB-xx00:
1. Locate power receptacle at back of E-FX-HB-xx00.
2. Plug unit end (female) of power cord into E-FX-HB-xx00 power receptacle.
3. Plug outlet end (male) of power cord into correct voltage AC wall socket.
4. At E-FX-HB-xx00 front, verify that P(o)W(e)R LED is illuminated.
Optionally Cascade Hubs
AT BACK
To cascade hubs by installing adapter cable(s) between stacked hubs:
1. Locate uplink adapter installed on E-FX-HB-xx00 9see page 4) and adapter cable ACC-0201.
2. Install one end of adapter cable to UPPER connector on expansion adapter on lowest hub in stack.
3. Install one end of adapter cable to LOWER connector on expansion adapter on next hub in stack.
4. Continue steps 2-3 until installation is complete.
AT FRONT
To cascade hubs by installing fiber cables between hubs:
1. Locate or build 100BASE-FX compliant two-stranded fiber cable with appropriate TX to RX connectors installed at both ends.
2. Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on front of one hub.
3. Connect male TX and RX cable connectors at other end of cable to RX and TX connectors, respectively, on front of second hub.
STAT
10BASE-FL
1
2
3
4
5
6
7
8
PWR
COL
ACT
BB
1
3
2
4
5
7
6
8
STAT
10BASE-FL
1
2
3
4
5
6
7
8
PWR
COL
ACT
BB
1
3
2
4
5
7
6
8
TX
TX RX
RX
TX
TX
RX
RX
Page 8
Optionally Connect to Backplane through TX Uplink
NOTE: Refer to 512-bit rule (page 3) to keep cable lengths within acceptable bounds.
To connect twisted-pair cable from E-FX-HB-xx00 100BASE-TX uplink adapter to network:
1. Locate 100BASE-TX uplink adapter installed at E-FX-HB-xx00 back. (See page 5.)
NOTE: AutoCross
feature on 100BASE-TX uplink adapter allows use of either straight-through or crossover 100BASE-TX cable configuration.
2. Locate or build 100BASE-TX compliant cables with male RJ-45 plug connectors at both ends. (See page 14.)
3. Connect male RJ-45 plug connector at one end of cable to E-FX-HB-xx00 100BASE-TX uplink adapter RJ-45 jack connector.
4. Connect male RJ-45 plug connector at other end of cable to RJ-45 jack connector on 100BASE-TX network device.
Optionally Connect to Backplane through FX Uplink
NOTE: Refer to 512-bit rule (page 3) to keep cable lengths within acceptable bounds.
To connect fiber cable from E-FX-HB-xx00 100BASE-FX uplink adapter to network:
1. Locate 100BASE-FX uplink adapter installed at E-FX-HB-xx00 back. (See page 5.)
2. Locate or build 100BASE-FX compliant fiber cable with male two­stranded TX to RX connectors at both ends. (See page 14.)
3. Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on E-FX-HB-xx00 100BASE-FX uplink adapter.
4. Connect male TX and RX cable connectors at other end of cable to RX and TX connectors, respectively, on 802.3 compliant 100BASE-FX network device.
Connect Hub to Terminal Devices using Fiber
NOTE: Refer to 512-bit rule (page 3) to keep cable lengths within acceptable bounds.
To connect fiber cable from E-FX-HB-xx00 ports to terminal devices:
1. Locate or build 100BASE-FX compliant two-stranded fiber cable with appropriate male TX to RX connectors installed at both ends.
2. Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on E-FX-HB-xx00 port.
3. Connect male TX and RX cable connectors at other end of cable to RX and TX connectors, respectively, on 802.3 compliant fiber device.
4. Repeat steps 1-3 until all terminal devices are connected.