Transition Networks E-FRL-MC05, E-FRL-MC05(SC), E-FRL-MC05(SM), E-FRL-MC05(L) User Manual

The Transition Networks E-FRL-MC05 series transceiver with LinkAlert™is a media access unit (MAU) that connects the AUI port of any DTE, repeater, or other network device, either directly or through an AUI cable, to an Ethernet
10BASE-FL device. The 10BASE-FL device is connected to the E-FRL-MC05 media converter through multimode fiber OR singlemode fiber, selected by E-FRL-MC05 model number.
The E-FRL-MC05 functions either in half-duplex mode or in full-duplex mode, depending upon the network devices to which the media converter is attached.
AUI/10BASE-FL
Transceiver
E-FRL-MC05
User’s Guide
E-FRL-MC05 in the Network . . . . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .4
Troubleshooting . . . . . . . . . . . . . . . .5
Cable Specifications . . . . . . . . . . . . .6
Technical Specifications . . . . . . . . . .7
Compliance Information . . . . . . . . . .8
STATUS
RX
TX
COL
ON = OK
E-FRL-MC05
Provides an AUI connector and a set of RX (receive) and TX (transmit)
ST
connectors to 10BASE-FL 850nm
multimode fiber.
E-FRL-MC05(SC)
Provides an AUI connector and an RX (receive) /TX (transmit)
SC
connector to
10BASE-FL 850nm multimode fiber.
E-FRL-MC05(SM)
Provides an AUI connector and a set of RX (receive) and TX (transmit)
ST
connectors to 10BASE-FL 1300nm
singlemode fiber.
E-FRL-MC05(L)
Provides an AUI connector and a set of RX (receive) and TX (transmit) ST 10BASE-FL connectors to 1300mn multimode fiber cable.
E-FRL-MC05 in the Network
NOTE: AUI drop cable also can be used to connect to the transceiver.
Using LinkAlert™
The LinkAlert™ feature allows the transceiver to pass 10BASE-FL-side link faults to the AUI side and to pass AUI-side link faults to the 10BASE-FL side.
E-FRL-MC05
2
10BASE-FL Hub
OR
OR
Hub with AUI connector
SQE = ON
STATUS
RX
TX
COL
ON = OK
STATUS
RX
TX
COL
ON = OK
STATUS
RX
TX
COL
ON = OK
SQE = OFF
SQE = ON
10BASE-FL
Device
Transceiver
FAULT INDICATION*
LINK FAULT INDICATION
Network
Device
AUI
Installation
Set Switches
NOTE: UP enables the indicated function on the 4-position switch located to the right of the 10BASE-FL connector and DOWN disables the indicated function.
1
SQE Test: (UP)
Enable SQE test
function when connecting to other devices.
(DOWN)
Disable SQE
test function when connecting to IEEE 802.3 compliant repeaters.
Default is enabled (UP).
2
LinkAlert: (UP)
Enable the
LinkAlert
function.
(DOWN)
Enable
standard Link Integrity Test.
Default is enabled (UP).
3
Half-Duplex/Full-Duplex Mode
:
(UP)
Enable half-duplex mode
when connecting to half-duplex network devices.
(DOWN)
Enable
full-duplex mode when connecting to full-duplex network devices.
Default is enabled (UP)
DO NOT USE FULL-DUPLEX WHEN
CONNECTING THE TRANSCEIVER TO A REPEATER.
.
4
Not Used
Install Cable
NOTE: See page 6 for cable specifications and configurations.
FIBER
Locate or build 10BASE-FL compliant fiber cable with male two­stranded TX to RX connectors at both ends.
Connect male TX and RX cable connectors at one end of cable to TX and RX female connectors, respectively, on media converter.
Connect female TX and RX cable connectors at other end of cable to RX and TX connectors of 802.3 compliant fiber device.
AUI
DROP CABLE
Connect AUI drop cable female connector to male AUI (DTE) connector on E-FRL-MC05.
•. Connect other end of AUI drop cable to 10BASE-5 network.
NETWORK DEVICE
Connect device female connector to male AUI (DTE) connector on E-FRL-MC05.
Connect to Power
The E-FRL-MC05 is powered through the AUI connection.