Transition Networks C/RS485-CF-01(SC), C/RS485-CF-02(SC), C/RS485-CF-01(SM), C/RS485-CF-02(SM), C/RS485-CF-01 User Manual

...
Designed to be installed in the TRANSITION Networks E-MCC-1600 Media Converter Chassis, the C/RS485-CF-0x series serial-port fiber extension Media Converters extend distances between RS-485 or RS-482 nodes for up to two (2)
kilometers over multimode fiber or up to twenty (20) kilometers over singlemode fiber.
C/RS485-CF-0x series Media Converters allow RS-485 two-wire half-duplex operation, RS-485 four-wire full-duplex operation, and RS-422 four-wire operation, with switch-selectable termination and biasing resistors, at speeds from 1 Kb/s to 500 Kb/s.
RS-485/422 Serial-Port Fiber Extension
Media Converters
C/RS485-CF-01, C/RS485-CF-02
USER’S GUIDE
C/RS485-CF-01
Provides one (1) terminal block RS­485/RS-422 copper connector and one (1) set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to multimode fiber @ 850 nM.
C/RS485-CF-01(SM)
Provides one (1) terminal block RS­485/RS-422 copper connector and one (1) set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to singlemode fiber @ 1300 nM.
C/RS485-CF-01(SC)
Provides one (1) terminal block RS­485/RS-422 copper connector and one (1) set of RX (receive) and TX (transmit) SC 100BASE-FX connectors to multimode fiber @ 850 nM.
C/RS485-CF-02
Provides one (1) DB-9 RS-485/RS-422 copper connector and one (1) set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to multimode
fiber @ 850 nM.
C/RS485-CF-02(SM)
Provides one (1) DB-9 RS-485/RS-422 copper connector and one (1) set of RX (receive) and TX (transmit) ST 100BASE-FX connectors to singlemode
fiber @ 1300 nM.
C/RS485-CF-02(SC)
Provides one (1) DB-9 RS-485/RS-422 copper connector and one (1) set of RX (receive) and TX (transmit) SC 100BASE-FX connectors to multimode
fiber @ 850 nM.
C/RS485-CF-0x in the Network . . . .2
Installation . . . . . . . . . . . . . . . . . . . .3
Operation . . . . . . . . . . . . . . . . . . . . .5
Fault Isolation and Correction . . . . .5
Cable Specifications . . . . . . . . . . . . .6
Technical Specifications . . . . . . . . . .7
Compliance Information . . . . . . . . . .8
C/RS485-CF-0X in the NETWORK
The C/RS485-CF-0x can be used to install a fiber network extension between RS-485 or RS-422 network nodes.
One slide switch on the C/RS485-CF-0x series Media Converter allows site selection of RS-485 2-wire (half-duplex) operation, RS-485 4-wire (full­duplex) operation, or RS-422 4-wire (full-duplex) operation (see page 3).
A second slide switch on the C/RS485-CF-0x series Media Converter allows echo prevention in two-wire mode or transmission only on "transmit/receive ­(B) RS-485 2wire, transmit - RS-422 and transmit/receive + (A) RS-485 2wire, transmit + RS-422" pair (see page 3).
A 4-position dip switch on the C/RS485-CF-0x series Media Converter allows site selection of 130 ohm terminator insertion on the "receive – C/RS485 4 wire, RS422 and receive + C/RS485 4 wire, RS422" pair or on the "transmit/receive - (B) C/RS485 2wire, transmit - RS422 and transmit/receive + (A) C/RS485 2wire, transmit + RS422" pair (see page 3.).
The dip switch also allows site selection of 1K ohm pull down on "transmit/receive - (B) C/RS485 2wire, transmit - RS422" or of 1K ohm pull up on "transmit/receive + (A) C/RS485 2wire, transmit + RS422” (see page 3).
C/RS485-CF-0x
2
RS-485/422 CABLE
RS-485/422 CABLE
INSTALLATION
Set Switches
Use a small flatblade screwdriver or a similar device to set the recessed switches according to the site installation.
1. Set the 2-wire /4-wire slide switch to the 4­wire setting to enable the "receive – RS-485 4 wire, RS422 and receive + RS-485 4 wire, RS-422" pair for RS-422 4 wire full duplex operation.
2. Set the RS-485/RS-422 slide switch to the RS-485 position to prevent echo in two-wire mode. Set the RS-485/RS-422 slide switch to the RS­422 to allow transmit only on "transmit/receive - (B) RS-485 2wire, transmit - RS-422 and transmit/receive + (A) RS-485 2wire, transmit + RS-422" pair.
Refer to the drawing and notes below for setting the 4-position dip switch.
* Position 1 ON inserts 130 ohm terminator on the "receive – RS-485
4 wire, RS-422 and receive + RS-485 4 wire, RS-422" pair.
** Position 2 ON inserts 130 ohm terminator on the "transmit/receive -
(B) RS-485 2wire, transmit - RS-422 and transmit/receive + (A) RS­485 2wire, transmit + RS-422" pair.
*** Position 3 ON enables 1K ohm pull
down
on "transmit/receive - (B)
RS-485 2wire, transmit - RS-422".
**** Position 4 ON enables 1K ohm pull
up
on "transmit/receive + (A)
RS-485 2wire, transmit + RS-422
Install Slide-In-Module in E-MCC-1600 Chassis
NOTE: Media Converter Slide-in-Modules can be installed in any installation slot, in any order.
1. Remove the Media Converter Slide-in-Module protective plate from
the selected installation slot by removing the two (2) screws that secure the plate to the front of the E-MCC-1600.
2. Carefully slide the Media Converter Slide-in-Module into the
installation slot, aligning the Media Converter Slide-in-Module with the installation guides.
NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against the backplane.
3. Secure the Slide-in-Module by securing the panel fastener screw
attached to the Slide-in-Module to the E-MCC-1600 chassis.
3
RS-485
RS-422
DOWN=ON Inserts 130 resistor on "receive"*
DOWN=ON Inserts 130 resistor on "transmit"**
DOWN=ON Enables 1K "pull-down"***
DOWN=ON Enables 1K "pull-up"***
*
1
2
3
4
2-wire
4-wire
INSTALLATION -- Continued
COPPER /DB-9 CONNECTOR
NOTE: Shielded cables are required on DB-9 for EMC compliance.
1. Locate or build TIA/EIA-574-DB-9 compliant cables configured as shown on page 7, with a male DB-9 connector at one end of the cable and with a straight-through cable.
2. Connect the male DB-9 connector at one end of the cable to the Media Converter female DB-9 connector.
3. Connect the other end of the cable to the node device.
COPPER /TERMINAL BLOCK CONNECTOR
1. Locate or build TIA/EIA-574-compliant terminal block cables configured as shown on page 7 and with straight-through cable.
2. Using a small flatblade screwdriver or a similar device, release each terminal block installation location as necessary. Refer to the diagram on page 7, connect the wires at one end of cable to the Media Converter terminal block connector.
3. Connect the other end of the cable to the node device.
FIBER
1. Locate or build TIA/EIA-574-compliant fiber cable with male two­stranded TX to RX connectors at both ends.
2. Connect the male TX and RX cable connectors at one end of the cable to the TX and RX female connectors, respectively, on the Media Converter.
3. Connect the male TX and RX cable connectors at the other end of the cable to the RX and TX connectors of the IEEE 802.3™ compliant fiber device.
Connect to Power
The Media Converter is powered by the E-MCC-1600.
C/RS485-CF-0x
4
T
X
R
X
TX
RX