1. Is the power LED on the media converter illuminated?
NO
• Is the Slide-In-Module properly connected to the Media Conversion Center
chasis backplane?
• Is the Power Supply Module properly connected both to the Media
Conversion Center chasis backplane and to the AC outlet?
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 2.
2. Is the 100BASE-TX Link LED illuminated?
NO
• Check UTP cables for proper connection and pin assignment. (See above.)
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 3.
3. Is the fiber Link LED illuminated?
NO
• Check fiber cables for proper connection.
• Verify that TX and RX cables on media converter are connected to RX and
TX ports, respectively, on the other 100BASE-FX device.
• Refer to Tech Tips available at: http://www.transition.com
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
Troubleshooting
Installing Slide-In-Module(s)
CAUTION: Wear a grounding device and observe electrostatic discharge precautions
when installing Media Converter Slide-in-Module(s) in the 16-Slot Media Conversion
Center. Failure to observe this caution could result in damage to, and subsequent
failure of, the Media Converter Slide-in-Module(s).
NOTE: Slide-in-Modules can be installed in any installation slot, in any order.
To install the Media Converter Slide-in-Module in the E-MCC-1600 chassis:
1. Ensure that switches on circuit board are set correctly for site installation.
2. Remove Media Converter Slide-in-Module protective plate from selected installation slot
by removing two screws that secure plate to front of E-MCC-1600.
3. Carefully slide Media Converter Slide-in-Module into installation slot, aligning
Media Converter Slide-in-Module with installation guides.
NOTE : Ensure that the Media Converter Slide-in-Module is firmly seated against the
backplane.
4. Secure Slide-in-Module to E-MCC-1600 chassis by rotating captive screw attached to
Slide-in-Module clockwise into chassis.
C/HSTR-CF-01
Switch Settings and Cable Requirements
The physical characteristics of the media cable must meet or exceed IEEE 802.5t
specifications.
Token Ring Cable Specifications
Copper Cable Specifications
Category 5 wire or better is required. Either shielded twisted pair (STP) or unshielded
twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 5:
Gauge 24 to 22 AWG
Attenuation 22 dB/100’ @ 100 MHz
Differential Characteristic Impedance 100 Ω ±15%
Maximum Cable Distance: 100 meters (330 feet)
Fiber Cable Specifications
MULTIMODE
Fiber-optic Cable Recommended: 62.5 / 125 µm multimode fiber
*Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm
Wavelength: 1300nM
Bit error rate: ≤10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber-optic Cable Recommended: 9 µm singlemode fiber
Wavelength: 1300nM
Bit error rate: ≤10
-9
Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber-optic Receiver Sensitivity: min: -32.5 dBm max: -8.0 dBm