Transition Networks CETCT1020-100 User Manual

The Transition Networks CETCT1020-100 Ethernet media is designed to be installed in a Transition Networks PointSystem™ chassis and connects 10Base-T shielded or unshielded twisted-pair copper cable to 10Base-2 coaxial copper cable.
The CETCT1020-100 supports up to 30 devices daisy-chained on one coax segment per twisted­pair segment.
User’s Guide
CETCT1020-100
Slide-in-Module Media Converter
• Coax to Twisted-Pair
• 10Base-2 to 10Base-T
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .4
Cable Specifications . . . . . . . . . . .5
Troubleshooting . . . . . . . . . . . . . .6
Technical Specifications . . . . . . . .7
Compliance Information . . . . . . . .8
Part Number Port One - Twisted-Pair Port Two - Coax
* Typical maximum cable distance. The actual maximum cable distances are
dependent upon the physical characteristics of the network installation.
CETCT1020-100 RJ-45, 10Base-T
100 m (328 ft)*
BNC, 10Base-2 185 m (607 ft)*
2
CETCT1020-100
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the switches and when installing the slide-in-module.
Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
Set the MDI / MDI-X Switch
The MDI / MDI-X switch is located on the media converter circuit board. See the drawing to the right for the different MDI/MDI-X configurations.
To satisfy the requirements for the 10Base-T connection, set the MDI / MDI-X switch as directed:
Install the Slide-in-Module
To install the CETCT10xx-10x slide-in-module media converter:
1. Locate and empty slot on the PointSystem™ chassis.
2. Carefully slide the slide-in-module into the installation slot, aligning the module with the installation guides.
3. Ensure that the slide-in-module is firmly seated inside the chassis.
4. Push in and rotate the attached panel fastener screw clockwise to secure the slide-in-module to the chassis front.
CFMFF100
10BASE-2
CECF100
CFMFF100
0
50½
Link Alert
E
D
CETCF100
CFETF100
LA
PWR
RXF
RXC
LNK
COL
SPD
PWR
FRX
CRX
FLNK
CLNK
100BASE-TX
RX
TX 100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
10BASE-2
10BASE-FL
10BASE-T
LKS
PWR
LKM
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R E S E T
I
0
Panel Fastener Screw
MDI-XMDI
NOTE: The media converter is powered through the Transition Networks PointSystem™ chassis.
If you are using: And you are connecting between
the CETCT10xx-10x and a:
Set the MDI/
MDI-X switch to
straight-through cable hub, switch, or router MDI
straight-through cable terminal, transceiver, or NIC MDI-X
crossover cable terminal, transceiver, or NIC MDI
crossover cable hub, switch, or router MDI-X
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Install the Coax Cable
1. Locate or build 10Base-2 compliant fiber cable with female, BNC connectors installed at both ends.
2. Connect the BNC cable connector at one end of the cable to the BNC port on the media converter.
NOTE: Install a 50 Ω terminator on the BNC port or ensure that the 50 switch is set to “50.”
3. Connect the BNC cable connector at the other end of the cable to the BNC port on the 10Base-2 compliant device.
NOTE: Ensure that the 10Base-2 coax cables are terminated properly at both ends. In a coax thinnet installation, the first and last device in a daisy-chain must be terminated using a 50 terminator. Also, ensure that the 10Base-2 segment is grounded to earth ground at a single point.
Connect the coax cable to the first media converter as shown.
Connect the coax cable
to the 10Base-2 compliant
device as shown
Install the 10Base-T Cable
1. Locate or build 10Base-T compliant copper cables with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the 10Base-T compliant device
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port
on the media
converter
4
CETCT1020-100
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Operation
Status LEDs
Use the status LEDs to monitor media converter operation in the network.
PWR On = The media converter is connected to external power.
LNK On = 10Base-T link connection.
RXT Flashing = Reception of data on the 10Base-T copper link.
RX2 Flashing = Reception of data on the 10Base-2 copper link.
COL Flashing = Signal collisions on the 10Base-2 port.
Installation -- Continued
Set the 0/50 ΩSwitch
Use a small, flat-blade screwdriver to set the recessed switch on the front panel of the media converter.
The 0/50 switch is used to satisfy the terminating/grounding requirements for the media converter.
0 = The 10Base-2 connection at the media converter is NOT terminated.
50 = The 10Base-2 connection at the media converter is terminated.
CETCT100
PWR
10Base-T 10Base2
500
RXT LNK
RX2 COL
500
SNMP
See the on-line documentation that comes with Transition Networks FocalPoint™ software for applicable commands and usage.
Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring:
• 10Base-T link status
• 10Base-T activity status.
• 10Base-2 activity status.
• 10Base-2 collision status.
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Cable Specifications
10Base-2 Cable
Cable type: Stranded Coaxial RG-58 Impedance: 50 @ 10 MHz Mutual capacitance: 24 pF/ft +/- 20% @ 10 MHz Maximum cable distance: 185 m (607 ft.) Minimum cable distance: 0.5 m (1.6 ft.) Maximum number of connections 30
10Base-T Cable
Category 3: (minimum requirement)
Gauge 24 to 22 AWG Attenuation 11.5 dB/100m @ 5-10 MHz Maximum cable distance: 100 m
Category 5: (recommended) Gauge 24 to 22 AWG Attenuation 22.0 dB/100m @ 100 MHz Maximum cable distance: 100 m
• Straight-through or crossover twisted-pair cable may be used.
• Shielded (STP) or unshielded (UTP) twisted-pair cable may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• RJ-45 Pin-out: Pin 1 = TD+, Pin 2 = TD-, Pin 3 = RD+, Pin 6 = RD-
• Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Troubleshooting
1. Is the PWR LED illuminated? NO
• Is the media converter inserted properly into the chassis?
• Is the power cord properly installed?
• Does the external power source provide power?
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the LNK LED illuminated? NO
• Check the twisted-pair 10Base-T cables for proper connection.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 3.
3. Is the COL LED flashing? NO
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 4.
4. Is the LA LED illuminated? YES
• Locate and correct device connection fault.
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Proceed to step 5.
5. Is the RXT LED flashing? NO
• If there is no activity on the 10Base-T port, proceed to step 6.
• If there is activity on the 10Base-T port, disconnect and reconnect the
10Base-T cable to restart the initialization process.
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 6.
6. Is the RX2 LED illuminated? NO
• Check 10Base-2 cables for proper connection.
• Verify that 10Base-2 cable connections on media converter and on
attached device are terminated properly
• Disconnect and reconnect the cable to restart the initialization process.
• Restart the workstation to restart the initialization process.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
6
CETCT1020-100
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
7
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CETCT1020-100 Series Media Converters Part Number(s):
CETCT1020-100
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
CETCT1020-100
to which this declaration refers is
in conformity with the following standards. CISPR 22:1993; EN 55022:1994, A-1:1995, A-2:1997 Class A; FCC Part 15 Subpart B;
EN 55024:1998; EN 61000-3-2:1995; EN 61000-3-3:1995
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
March 16, 2001
Stephen Anderson, Vice-President of Engineering Date
Technical Specifications
For use with Transition Networks Model CETCT1020-100 or equivalent
Standards IEEE 802.3™
Dimensions 3.4" x 0.86" x 5.0" (86mm x 22mm x 127mm)
Weight 3 oz (91 g) (approximate)
Data Rate 10 Mb/s (half-duplex mode)
Power Consumption 2.4 watts (typical)
MTBF 595,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
1,471,000 hours (Bellcore7 V5.0)
Environment Tmra*: 0 to 60°C (32 to 140° F )
Storage Temperature: -20 to 85°C (-4 to 185° F ) Humidity 10 to 90%, non condensing Altitude 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™chassis in which this module will be installed.
The information in this user’s guide is subject to change. For the most up-to-date information, see the CETCT10xx-10x user’s guide on-line at www.transition.com.
Compliance Information
CISPR22/EN55022 Class A + EN55204; CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations This digital apparatus does not exceed the Class A limits for radio
noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures. Achtung ! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich. Attention ! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners.
Copyright Restrictions
© 2001, 2004-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical ­without written permission from Transition Networks.
Printed in the U.S.A.
33181.D
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Contact Us:
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Transition Networks, 6475 City West Pkwy, Minneapolis, MN 55344, USA telephone: 952-941-7600, toll free: 800-526-9267, fax: 952-941-2322
Loading...