Transition Networks CBFTF1013-110, CBFTF1016-110, CBFTF1014-110, CBFTF1015-110, CBFTF1017-110 User Manual

...
Part Number Copper - two (2) ports
10Base-T/100Base-TX
Duplex Fiber-Optic - one (1) port 100Base-FX
CBFTF1011-110 RJ-45
100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
100 m (328 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)*
CBFTF1015-110
(long haul)
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)*
CBFTF1016-110
(extra long haul)
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 60 km (37.2 miles)*
CBFTF1017-110
(long wave length)
RJ-45 100 m (328 ft)*
SC, 1550 nm single mode 80 km (49.7 miles)*
100 m (328 ft)*
MT-RJ, 1300 nm multimode 2 km (1.2 miles)*
100 m (328 ft)*
MT-RJ, 1310 nm single mode 5 km (3.1 miles)*
User’s Guide
CBFTF10xx-11x
Slide-in-Module Media Converter
• Copper to Fiber
• 10/100 Bridging (3-Port)
• 10/100Base-TX to 100Base-FX
The CBFTF10xx-11x 3-port Ethernet/fast Ethernet bridging media converter is designed to be installed into a Transition Networks PointSystem™ chassis and allows connection of 10Base-T Ethernet and/or 100Base-TX fast Ethernet twisted-pair copper network devices to network devices on a 100Base-FX fast Ethernet fiber network.
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network.
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .8
Cable Specifications . . . . . . . . . .11
Technical Specifications . . . . . . .13
Troubleshooting . . . . . . . . . . . . .14
Compliance Information . . . . . . .15
Contact Us . . . . . . . . . . . . . . . . .16
2
CBFTF10xx-11x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit (RX) = receive
** CBFTF1029-
110 and -111 are intended to be installed in the same network
where one is the local converter and the other is the remote converter.
*** CBFTF1029-
112 and -113 are intended to be installed in the same network
where one is the local converter and the other is the remote converter.
Installation
Copper and Fiber Ports
The figure below illustrates the locations of the two (2) twisted-pair copper ports and the one (1) fiber port.
Part Number Copper - two (2) ports
10Base-T/100Base-TX
Fiber-Optic - one (1) port Single Fiber
CBFTF1029-110 RJ-45
100 m (328 ft)*
SC, 1310 nm (TX)/1550 nm (RX) single mode, 20 km (12.4 miles
CBFTF1029-111 RJ-45
100 m (328 ft)*
SC, 1550 nm (TX)/1310 nm (RX) single mode, 20 km (12.4 miles)*
CBFTF1029-112 RJ-45
100 m (328 ft)*
SC, 1310 nm (TX)/1550 nm (RX) single mode, 40 km (24.8 miles)*
CBFTF1029-113 RJ-45
100 m (328 ft)*
SC, 1550 nm (TX)/1310 nm (RX) single mode, 40 km (24.8 miles)*
CBFTF110
10/100TX
FD
LACT
PWR
10/100TX
Twisted-Pair Port 1 (TP1)
Twisted-Pair Port 2 (TP2)
Fiber Port 1
(F1)
100Base-FX
The stand-alone version of the media converter is SBFTF10xx-11x. For more information, see the SBFTF10xx-11x user’s guide on-line at: www.transition.com.
Installation -- Continued
Set the Dip Switches
The dip switches are located on the side of the media converter. Use a small, flat-blade screwdriver or a similar device to set each dip switch.
“SW1” switches 1 - 6
Dip switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
Dip switch 4 applies to fiber port 1 (F1).
Dip switches 5 and 6 apply to both twisted-pair copper ports (TP1 and TP2).
“Config. Switches” 1 - 4
Dip switches 1, 2, 3, and 4 apply only to twisted-pair copper port 2 (TP2).
NOTE: Switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
3
1. Twisted-Pair Auto-Negotiation
UP (Enabled) - The media converter “advertises”
ALL rate and mode capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled) - The bridging media converter does not “advertise” the rate and mode capabilities to the network. Switches 2 and 3 are then used to set the twisted-pair rate and mode.
2. Twisted-Pair Rate
UP (100Base-TX) - Sets the twisted-pair rate to
100Base-TX.
DOWN (10Base-T) - Sets the twisted-pair rate to 10Base-T.
3. Twisted-Pair Mode
UP (Full-Duplex) - The twisted-pair cable
distances are constrained by the cable requirements (see pages 1 and 2).
DOWN (Half-Duplex): - The twisted-pair cable distances are constrained by the 512-Bit Rule (see page 9).
DOWN
1
UP
Twisted-Pair Auto-Negotiation ON
Twisted-Pair Auto-Negotiation OF
F
Twisted-pair 100Base-TX
Twisted-pair 10Base-T
DOWN
UP
2
Twisted-pair Full-Duplex
Twisted-pair Half-Duplex
DOWN
UP
3
4
CBFTF10xx-11x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation -- Continued
Set the Dip Switches -- Continued
NOTE: Dip switch 4 (in the “SW” set) applies to fiber port 1 (F1).
4. Fiber Mode (Fiber Port 1)
UP (Full-Duplex) - The cable distances for fiber port
1 (F1) are constrained by the cable requirements (see pages 1 and 2).
DOWN (Half-Duplex) - The cable distances for fiber port 1 (F1) are constrained by the 512-Bit Rule (see page 9).
NOTE: Dip switches 5 and 6 (in the “SW” set) apply to both twisted-pair copper ports (TP1 and TP2).
5. AutoCross
UP (Enable) - The media converter connects
automatically to either straight-through or crossover twisted-pair copper cable (see page 12).
DOWN (Disable) - Either straight-through or crossover twisted-pair copper cable must be installed, according to the site requirements
6. Not in use
Fiber Full-Duplex
Fiber Half-Duplex
DOWN
UP
4
AutoCross Enable
AutoCross Disable
UP
5
DOWN
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
5
Installation -- Continued
Set the Dip Switches -- Continued
NOTE: Dip switches 1, 2, 3, and 4 (in the Config. Switches set) apply only to twisted-pair copper port 2 (TP2).
1. Twisted-Pair Auto-Negotiation
UP (Enabled) - The media converter “advertises” ALL
rate and mode capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled) - The bridging media converter does not “advertise” the rate and mode capabilities to the network. Switch 2 and switch 3 are then used to set the twisted-pair rate and mode.
2. Twisted-Pair Rate
UP (100Base-TX) - Sets the twisted-pair rate to
100Base-TX.
DOWN (10Base-T) - Sets the twisted-pair rate to 10Base-T.
3. Twisted-Pair Mode
UP (Full-Duplex) - The twisted-pair cable distances
are constrained by the cable requirements (see pages 1 and 2).
DOWN (Half-Duplex) - The twisted-pair cable distances are constrained by the 512-Bit Rule (see page 9).
4. Monitor for Twisted-Pair Port 2 (TP2)
UP (OFF) - The twisted-pair port 2 (TP2) functions as directed by switches 1, 2, and 3.
DOWN (ON) - The twisted-pair port 2 (TP2)
functions as a “sniffer” port and transmits all packets received from ports F1 and TP1.
Twisted-Pair Full-Duplex
Twisted-Pair Half-Duplex
UP
DOWN
3
Monitor on TP2 OFF
Monitor on TP2 ON
UP
DOWN
4
Twisted-Pair 100Base-TX
Twisted-Pair 10Base-T
UP
DOWN
2
UP
DOWN
1
Twisted-Pair Auto-Negotiation ON
Twisted-Pair Auto-Negotiation OF
F
Loading...