Transition Networks CBFTF1011-140, CBFTF1013-140, CBFTF1014-140, CBFTF1015-140, CBFTF1016-140 User Manual

...
Installation . . . . . . . . . . . . . . . . . .2
Operation . . . . . . . . . . . . . . . . . . .8
Cable Specifications . . . . . . . . . .12
Technical Specifications . . . . . . .13
Troubleshooting . . . . . . . . . . . . .14
Compliance Information . . . . . . .15
Contact Us . . . . . . . . . . . . . . . . .16
Part Number Copper - four (4) ports
Duplex Fiber-Optic - two (2) ports 100Base-FX
CBFTF1011-140 RJ-45
100 m (328 ft)*
ST, 1300 nm multimode 2 km (1.2 miles)*
CBFTF1013-140 RJ-45
100 m (328 ft)*
SC, 1300 nm multimode 2 km (1.2 miles)*
CBFTF1014-140 RJ-45
100 m (328 ft)*
SC, 1310 nm single mode 20 km (12.4 miles)*
CBFTF1015-140
(long haul)
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 40 km (24.8 miles)*
CBFTF1016-140
(extra long haul)
RJ-45 100 m (328 ft)*
SC, 1310 nm single mode 60 km (37.2 miles)*
CBFTF1017-140
(long wave length)
RJ-45 100 m (328 ft)*
SC, 1550 nm single mode 80 km (49.7 miles)*
CBFTF1018-140 RJ-45
100 m (328 ft)*
MT-RJ, 1300 nm multimode 2 km (1.2 miles)*
CBFTF1025-140 RJ-45
100 m (328 ft)*
MT-RJ, 1310 nm single mode 5 km (3.1 miles)*
User’s Guide
CBFTF10xx-14x
Slide-in-Module Media Converter
• Copper to Fiber
• 10/100 Bridging 6-Port
• (4 copper / 2 fiber)
• 10/100Base-TX to 100Base-FX
The CBFTF10xx-14x 6-port Ethernet/Fast Ethernet bridging media converter is designed to be installed into a Transition Networks PointSystem™ chassis and allows connection of 10Base-T Ethernet and/or 100Base-TX Fast Ethernet twisted­pair copper network devices to network devices on a 100Base-FX Fast Ethernet fiber network.
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network.
2
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit (RX) = receive
** CBFTF1029-140 and CBFTF1029-141 are intended to be installed in the same
network where one is the local converter and the other is the remote.
*** CBFTF1029-142 and CBFTF1029-143 are intended to be installed in the same
network where one is the local converter and the other is the remote.
The stand alone version of this media converter is SBFTF10xx-14x. For more information, see the SBFTF10xx-14x user’s guide on-line at: www.transition.com.
Installation
Copper and Fiber Ports
The figure below illustrates the locations of the four (4) twisted-pair copper ports and the two (2) fiber ports.
Part Number Copper - four (4) ports
Fiber-Optic - two (2) ports Single Fiber
CBFTF1029-140 RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX) single mode, 20 km (12.4 miles
CBFTF1029-141 RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX) single mode, 20 km (12.4 miles)*
CBFTF1029-142 RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX) single mode, 40 km (24.8 miles)*
CBFTF1029-143 RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX) single mode, 40 km (24.8 miles)*
10/100TX
FD
LACT
PWR
10/100TX
Twisted-Pair Port 1 (TP1)
Twisted-Pair Port 2 (TP2)
10/100TX
FD
LACT
10/100TX
Twisted-Pair Port 3 (TP3)
Twisted-Pair Port 4 (TP4)
Fiber Port 2
(F2)
Fiber Port 1
(F1)
100Base-FX
100Base-FX
CBFTF140
Installation -- Continued
Set the Dip Switches
The dip switches are located on the side of the media converter. Use a small, flat blade screwdriver or a similar device to set each dip switch.
“SW1” switches 1 - 6
Dip switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
Dip switch 4 applies to fiber port 1 (F1).
Dip switch 5 applies to all twisted-pair copper ports (TP1, TP2, TP3, TP4).
Dip switch 6 applies to both fiber ports (F1, F2).
“Config. Switches” 1 - 4
Dip switches 1, 2, 3, and 4 apply only to twisted-pair copper port 2 (TP2).
NOTE: Switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
1. Twisted-Pair Auto-Negotiation
UP (Enabled) - The media converter “advertises”
ALL rate and mode capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled) - The bridging media converter does not “advertise” the rate and mode capabilities to the network. Switches 2 and 3 are then used to set the twisted-pair rate and mode.
2. Twisted-Pair Rate
UP (100Base-TX) - Sets the twisted-pair rate to
100Base-TX.
DOWN (10Base-T) - Sets the twisted-pair rate to 10Base-T.
3. Twisted-Pair Mode
UP (Full-Duplex) - The twisted-pair cable
distances are constrained by the cable requirements (see pages 1 and 2).
DOWN (Half-Duplex): - The twisted-pair cable distances are constrained by the 512-Bit Rule (see page 9).
DOWN
1
UP
Twisted-Pair Auto-Negotiation ON
Twisted-Pair Auto-Negotiation OFF
Twisted-pair 100Base-TX
Twisted-pair 10Base-T
DOWN
UP
2
Twisted-pair Full-Duplex
Twisted-pair Half-Duplex
DOWN
UP
3
4
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation -- Continued
Set the Dip Switches -- Continued
NOTE: Dip switch 4 (in the “SW” set) applies to fiber port 1 (F1).
4. Fiber Mode (Fiber Port 1)
UP (Full-Duplex) - The cable distances for fiber port 1 (F1) are constrained by the cable requirements (see pages 1 and 2).
DOWN (Half-Duplex) - The cable distances for fiber port 1 (F1) are constrained by the 512-Bit Rule (see pages 9).
NOTE: Dip switch 5 (in the “SW” set) applies to all twisted-pair copper ports (TP1, TP2, TP3, TP4).
5. AutoCross
UP (Enable) - The media converter connects automatically to either straight-through or crossover twisted-pair copper cable.
DOWN (Disable) - Either straight-through or crossover twisted-pair copper cable must be installed, according to the site requirements
NOTE: Dip switch 6 (in the “SW” set) applies to both fiber ports (F1, F2).
6. Fiber Redundancy
UP (Disable) - When Fiber Redundancy is disabled, Fiber Port 1 (F1) and Fiber Port 2 (F2) act as normal bridging ports.
DOWN (Enable) - When Fiber Redundancy is enabled, Fiber Port 1 (F1) and Fiber Port 2 (F2) are configured as either forwarding or disabled. At any given time, one port will be disabled and one port will be forwarding.
Redundant Fiber Disable
Redundant Fiber Enable
6
UP
DOWN
Fiber Full-Duplex
Fiber Half-Duplex
DOWN
UP
4
AutoCross Enable
AutoCross Disable
UP
5
DOWN
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Set the Dip Switches -- Continued
NOTE: Dip switches 1, 2, 3, and 4 (in the Config. Switches set) apply only to twisted-pair copper port 2 (TP2).
1. Twisted-Pair Auto-Negotiation
UP (Enabled) - The media converter “advertises”
ALL rate and mode capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled) - The bridging media converter does not “advertise” the rate and mode capabilities to the network. Switch 2 and switch 3 are then used to set the twisted-pair rate and mode.
2. Twisted-Pair Rate
UP (100Base-TX) - Sets the twisted-pair rate to
100Base-TX.
DOWN (10Base-T) - Sets the twisted-pair rate to 10Base-T.
3. Twisted-Pair Mode
UP (Full-Duplex) - The twisted-pair cable
distances are constrained by the cable requirements (see pages 1 and 2).
DOWN (Half-Duplex) - The twisted-pair cable distances are constrained by the 512-Bit Rule (see page 9).
4. Monitor for Twisted-Pair Port 2 (TP2)
UP (Off) - The twisted-pair port 2 (TP2) functions as directed by switches 1, 2, and 3.
DOWN (On) - The twisted-pair port 2 (TP2)
functions as a “sniffer” port and transmits all packets received from ports F1 and TP1.
Twisted-Pair Full-Duplex
Twisted-Pair Half-Duplex
UP
DOWN
3
Monitor on TP2 OFF
Monitor on TP2 ON
UP
DOWN
4
Twisted-Pair 100Base-TX
Twisted-Pair 10Base-T
UP
DOWN
2
UP
DOWN
1
Twisted-Pair Auto-Negotiation ON
Twisted-Pair Auto-Negotiation OF
F
6
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation -- Continued
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the jumpers and when installing the media converter.
Failure to observe this caution could result in damage to, and subsequent failure of, the media converter.
Use small, needle-nose pliers or a similar device when setting the jumpers.
Set the Fiber Duplex Jumper (Fiber Port 2)
The fiber duplex jumper sets the full-duplex/half-duplex mode for fiber port 2 (F2). It is located on the circuit board and is labeled “F” and “H”.
Full-Duplex The cable distances for fiber port 2 (F2)
are constrained by the cable requirements (see pages 1 and 2).
Half-Duplex The cable distances for fiber port 2 (F2)
are constrained by the 512-Bit Rule (see page 9).
Set the Hardware/Software Jumper
The hardware/software jumper is located on the circuit board and is labeled “H” and “S”.
Hardware The media converter settings are determined
by dip switch settings (p. 3-5).
Software The media converter settings are determined
by the most-recently saved, on-board microprocessor settings.
Install the Slide-in-Module
1. Carefully slide the slide-in-module into two adjacent installation slots, aligning the module with the installation guides.
2. Ensure that the module is firmly seated inside the chassis.
3. Push in and rotate the attached panel fastener screw clockwise to secure the module to the to the chassis front.
Half-Duplex
F
H
Full-Duplex
F
H
10BASE-2
CECF100
CFMFF100
0
50½
Link Alert
E
D
CETCF100
CFETF100
LA
PWR
RXF
RXC
LNK
COL
SPD
PWR
FRX
CRX
FLNK
CLNK
100BASE-TX
RX
TX 100BASE-FX
Link Alert
E
D
0
50½
LA
PWR
RXF
RXC
LNK
COL
10BASE-2
10BASE-FL
10BASE-T
LKS
PWR
LKM
Multimode
Singlemode
TX
RX
TX
RX
I
0
TERM
INIT
RX
TX
LNK
PWR
CPSMM120
SERIAL
10BASE-T
R E S E T
I
0
Panel Fastener Screw
Software Mode
Hardware Mode
H
S
H
S
7
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Connect the Fiber Cable
1. Locate or build IEEE 803.2™ compliant 100Base-FX fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the CBFTF10xx-14x media converter as described:
• Connect the male TX cable connector to the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the other device (another media converter, hub, etc.) as described:
• Connect the male TX cable connector to the female RX port.
• Connect the male RX cable connector to the female TX port.
Connect the Twisted-Pair Copper Cable
The AutoCross feature allows either MDI (straight-through) or MDI-X (crossover) cable connections to be configured automatically, according to the network conditions.
1. Locate or build IEEE 803.2™ compliant 10Base-T or 100Base-TX cables, with male, RJ-45 connectors installed at both ends.
2. Connect the RJ-45 connector at one end of the cable to the RJ-45 port on the CBFTF10xx-14x media converter.
3. Connect the RJ-45 connector at the other end of the cable to the RJ-45 port on the other device (switch, workstation, etc.).
RJ-45 port
on the other device
(switch, work station, etc.)
RJ-45 port
on the media
converter
Connect the fiber cable to the media converter as shown.
Connect the fiber cable
to the other device
(media converter,
hub, etc.) as shown
RX
TX
RX
TX
8
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Installation -- Continued
Power the Slide-in-Module
The slide-in-module media converter is powered through the Transition Networks PointSystem™ chassis.
Operation
Status LEDs
Use the status LEDs next to the fiber ports to monitor the media converter and the fiber network connections.
F(ull) D(uplex)
On = Full-duplex connection.
Off = Half-duplex connection.
L(ink) ACT(ivity)
On = Fiber link connection.
Flashing = Fiber network activity.
P(o)W(e)R
On = Connection to external AC or DC power.
FD
LACT
PWR
FD
LACT
1
1
The “FD” and “LACT” LEDs on the left refer to Fiber Port 2 (F2).
The “FD” and “LACT” LEDs on the right refer to Fiber Port 1 (F1).
9
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Operation -- Continued
Status LEDs -- Continued
Use the bi-color twisted-pair status LEDs to monitor the twisted-pair copper network connections.
Duplex/Link LED
Amber = A link on the half-duplex twisted-pair copper link.
Flashing Amber = Activity on the half-duplex copper link.
Green = A link on the full-duplex twisted-pair copper link.
Flashing Green = Activity on the full-duplex copper link.
Speed LED
Amber = 10 Mb/s operation.
Green = 100 Mb/s operation.
Product Features
Full-Duplex Network
In a full-duplex network, maximum cable lengths are determined by the type of cables that are used. See pages 1 and 2 for the cable specifications for the
different CBFTF10xx-14x models.
The 512-Bit Rule does not apply in a full-duplex network.
Half-Duplex Network (512-Bit Rule)
In a half-duplex network, the maximum cable lengths are determined by the round trip delay limitations of each Fast Ethernet collision domain. (A collision domain is the longest path between any two terminal devices, e.g. a terminal, switch, or router.)
The 512-Bit Rule determines the maximum length of cable permitted by calculating the round-trip delay in bit-times (BT) of a particular collision domain. If the result is less than or equal to 512 BT, the path is good.
For more information on the 512-Bit Rule, see the white paper titled “Collision Domains” on the Transition Networks website at: www.transition.com.
Duplex/Link Speed
10/100TX
10
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Operation -- Continued
Product Features -- Continued
Distance Extension
The CBFTF10xx-14x 6-point bridging media converter segments up to four (4) 10Base-T copper Ethernet and/or 100Base-TX copper Fast Ethernet and up to two (2) 100Base-FX fiber Fast Ethernet collision domains.
In a half-duplex Ethernet or Fast Ethernet environment, the CBFTF10xx-14x media converter extends network distances by segmenting collision domains so that the 512-Bit Rule applies separately to each collision domain (see page
9).
In a full-duplex Ethernet or Fast Ethernet environment, the CBFTF10xx-14x media converter extends network distances to the physical cable limitations imposed by the selected twisted-pair copper fiber cables (see pages 1 and 2).
Rate Conversion
The CBFTF10xx-14x media converter allows connection of 10Mb/s terminal devices on a 10Base-T legacy Ethernet copper network to 100Mb/s terminal devices on a 100Base-TX Fast Ethernet copper network and/or to 100Mb/s terminal devices on a 100Base-FX Fast Ethernet fiber network.
Congestion Reduction
The CBFTF10xx-14x media converter does not forward collision signals or error packets from one collision domain to another, improving baseline network performance. In addition, the media converter filters packets destined for local devices, also reducing network congestion.
Auto-Negotiation
The Auto-Negotiation feature allows the CBFTF10xx-14x media converter to automatically configure itself to achieve the best possible mode of operation over a link. The media converter broadcasts its speed (10 Mb/s or 100 Mb/s) and duplex capabilities (full or half) to the other devices and negotiates the best mode of operation. Auto-Negotiation allows quick and easy installation because the optimal link is established automatically.
A scenario where the media converter is linked to a non-negotiating device is a case where the user may want to disable Auto-Negotiation. In this instance, the mode of operation will drop to the least common denominator between the two devices (e.g.: 10 Mb/s, half-duplex). Disabling this feature gives the user the ability to force the connection to the desired speed and duplex mode of operation.
11
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Operation -- Continued
Product Features -- Continued
AutoCross™
When the AutoCross feature is activated, it allows either straight-through (MDI) or crossover (MDI-X) copper cables to be used when connecting to 10Base-T or 100Base-TX devices. AutoCross determines the characteristics of the connection and automatically configures the unit to link up, regardless if the copper cable is MDI or MDI-X configuration. (Transition networks recommends leaving the device in the default “enable” mode.)
Fiber Redundancy
The CBFTF10xx-14x media converter provides stable and affordable Fiber Redundancy in highly critical Ethernet and Fast Ethernet segments.
When the redundancy feature is enabled, only one fiber connection (primary) is active at a time. This primary connection is in the forwarding stage while the other fiber connection (secondary) is put in the disabled state.
When failure on the primary fiber connection occurs, it is detected by a converter. The secondary connection is activated and becomes the primary link. The original fiber link is put in the disabled state and becomes secondary until the failure on primary fiber connection occurs.
SNMP
See the on-line documentation that comes with Transition Networks FocalPoint™ software for applicable commands and usage.
Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring:
• Media converter power
• Copper link and fiber link status
• Copper port speed
• Hardware switch settings
Also, use SNMP to enter network commands that:
• Enable/disable Auto-Negotiation on copper
• Force 10Mb/s or 100Mb/s on copper
• Force full-duplex or half-duplex on copper and/or fiber
• Enable/disable pause and source address change
• Enable/disable monitor port (advanced filters available)
• Select advertised modes (when Auto-Negotiation is enabled)
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into the beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
12
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Fiber Cable
Bit Error Rate: <10-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
CBFTF1011-140 1300 nm multimode CBFTF1013-140 1300 nm multimode
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
CBFTF1014-140 1310 nm single mode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
CBFTF1015-140
(long haul)
1310 nm single mode Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 26.0 dB
CBFTF1016-140
(extra long haul)
1310 nm single mode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 29.0 dB
CBFTF1017-140
(long wave length)
1550 nm single mode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 29.0 dB
CBFTF1018-140 1300 nm multimode Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -33.5 dBm max: -14.0 dBm Link Budget: 14.5 dB
CBFTF1025-140 1310 nm single mode Fiber-optic Transmitter Power: min: -11.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -20.0 dBm max: -3.0 dBm Link Budget: 9.0 dB
CBFTF1029-140 1310 nm (TX) / 1550 nm (RX) simplex CBFTF1029-141 1550 nm (TX) / 1310 nm (RX) simplex
Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
CBFTF1029-142 1310 nm (TX) / 1550 nm (RX) simplex CBFTF1029-143 1550 nm (TX) / 1310 nm (RX) simplex
Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC-825/CDRH standards and complies with 21 CFR1040.10 and 21CFR1040.11.
13
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Cable Specifications -- Continued
Copper Cable
Category 3: (Minimum requirement for 10 Mb/s operation)
Gauge 24 to 22 AWG Attenuation 11.5 dB/100m @ 5-10 MHz Maximum Cable Distance 100 meters
Category 5: (Minimum requirement for 100 Mb/s operation)
Gauge 24 to 22 AWG Attenuation 22.0 dB /100m @ 100 MHz Maximum Cable Distance 100 meters
• Straight-through or crossover twisted-pair cable may be used.
• Shielded twisted-pair (STP) or unshielded twisted-pair (UTP) may be used.
• Pins 1&2 and 3&6 are the two active pairs in an Ethernet network .
• Use only dedicated wire pairs for the active pins: (e.g., blue/white & white/blue, orange/white & white/orange, etc.)
• Do not use flat or silver satin wire.
Crossover Cable
1 2
3 6
Straight-Through Cable
Twisted Pair #1
Twisted Pair #1
Twisted Pair #2
Twisted Pair #2
1 2
3 6
1 2
3 6
1 2
3 6
Technical Specifications
For use with Transition Networks Model CBFTF10xx-14x or equivalent.
Standards IEEE 802.3™
Data Rate 10 Mb/s, 100 Mb/s
Dimensions 3.4" x 1.72" x 5.0" (86 x 44 x 127 mm)
Weight 6 oz. (181 g) (approximate)
Power Consumption 4.95 watts
MTBF 1,023,000 hours (MIL217F2 V5.0) (MIL-HDBK-217F)
4,660,000 hours (Bellcore7 V5.0)
Packet Size: Memory: 256K bytes (2 Mbit)
Unicast MAC address: 4K bytes Maximum packet size: 1536 bytes
Environment Tmra*: 0 to 60°C (32 to 140°F )
Storage Temp: -20 to 85°C (-4 to 185°F) Humidity: 5 to 95%, non condensing Altitude: 0 to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™ chassis in which this slide-in-module will be installed.
The information in this user’s guide is subject to change. For the most up-to-date information, please see the user’s guide on-line at: www.transition.com
14
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the power LED on the media converter illuminated? NO
• Is the media converter slide-in-module installed properly in the
chassis?
• Is the power cord properly installed in the chassis and at the external
power source?
• Does the external power source provide power?
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the “Duplex/Link” LED illuminated on a port with twisted-pair cable installed? NO
• Check the copper cables for proper connection.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Amber = The media converter has selected half-duplex mode.
• Green = The media converter has selected full-duplex mode.
• If the mode is not correct, disconnect and reconnect the twisted pair
cable to restart the initialization process.
• Proceed to step 3.
3. Is the “LACT” LED illuminated on a port with fiber cable installed? NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables are connected to the RX and TX
ports, respectively, on the 100Base-FX device.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Proceed to step 4.
4. Is the “Speed” LED illuminated on a port with twisted-pair cable installed? NO
• Check the copper cables for proper connection.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
YES
• Amber = The media converter has selected 10Mb/s operation.
• Green = The media converter has selected 100Mb/s operation.
• If the speed is not correct, disconnect and reconnect the twisted pair
cable to restart the initialization process.
• Contact Technical Support: US/Canada: 1-800-260-1312,
International: 00-1-952-941-7600.
15
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Compliance Information
CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten. In diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
VCCI Class 1 Compliance
This equipment is in the 1st Class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council For Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and/or industrial areas. When used in a residential area or in an adjacent area thereto, interference may be caused to radio and TV receivers, etc. Read the instructions for correct handling.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG­Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2001-2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks. Printed in the U.S.A.
33224.G
Contact Us
Technical Support
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, USA telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 USA Model: CBFTF10xx-14x Series Media Converters Part Number(s): CBFTF1011-140, CBFTF1013-140, CBFTF1014-140, CBFTF1015-140,
CBFTF1016-140, CBFTF1017-140, CBFTF1018-140, CBFTF1025-140, CBFTF1029-140, CBFTF1029-141, CBFTF1029-142, CBFTF1029-143
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
CBFTF10xx-14x
to which this declaration refers is
in conformity with the following standards. CISPR 22:1993; EN 55022:1994 Class A; EN 55024:1998; FCC Part 15 Subpart B;
21 CFR subpart J; EN 61000-3-2:1995; EN 61000-3-3:1995
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
_April 16, 2001_____
Stephen Anderson, Vice-President of Engineering Date
Loading...