2
CBFTF10xx-14x
24-Hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit (RX) = receive
** CBFTF1029-140 and CBFTF1029-141 are intended to be installed in the same
network where one is the local converter and the other is the remote.
*** CBFTF1029-142 and CBFTF1029-143 are intended to be installed in the same
network where one is the local converter and the other is the remote.
The stand alone version of this media converter is SBFTF10xx-14x. For more
information, see the SBFTF10xx-14x user’s guide on-line at: www.transition.com.
Installation
Copper and Fiber Ports
The figure below illustrates the locations of the four (4) twisted-pair copper ports
and the two (2) fiber ports.
Part Number Copper - four (4) ports
10Base-T/100Base-TX
Fiber-Optic - two (2) ports
Single Fiber
CBFTF1029-140 RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX)
single mode, 20 km (12.4 miles
CBFTF1029-141 RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX)
single mode, 20 km (12.4 miles)*
CBFTF1029-142 RJ-45
100 m (328 ft)*
SC, 1310 mn (TX)/1550 nm (RX)
single mode, 40 km (24.8 miles)*
CBFTF1029-143 RJ-45
100 m (328 ft)*
SC, 1550 mn (TX)/1310 nm (RX)
single mode, 40 km (24.8 miles)*
10/100TX
FD
LACT
PWR
10/100TX
Twisted-Pair
Port 1 (TP1)
Twisted-Pair
Port 2 (TP2)
10/100TX
FD
LACT
10/100TX
Twisted-Pair
Port 3 (TP3)
Twisted-Pair
Port 4 (TP4)
Fiber Port 2
(F2)
Fiber Port 1
(F1)
100Base-FX
100Base-FX
CBFTF140
Installation -- Continued
Set the Dip Switches
The dip switches are located on the side of the media converter. Use a small,
flat blade screwdriver or a similar device to set each dip switch.
“SW1” switches 1 - 6
Dip switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
Dip switch 4 applies to fiber port 1 (F1).
Dip switch 5 applies to all twisted-pair copper ports (TP1, TP2, TP3, TP4).
Dip switch 6 applies to both fiber ports (F1, F2).
“Config. Switches” 1 - 4
Dip switches 1, 2, 3, and 4 apply only to twisted-pair copper port 2 (TP2).
NOTE: Switches 1, 2, and 3 apply only to twisted-pair copper port 1 (TP1).
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
1. Twisted-Pair Auto-Negotiation
UP (Enabled) - The media converter “advertises”
ALL rate and mode capabilities to the network:
• 100Mb/s full-duplex • 100Mb/s half-duplex,
• 10Mb/s full-duplex • 10Mb/s half-duplex.
DOWN (Disabled) - The bridging media converter
does not “advertise” the rate and mode
capabilities to the network. Switches 2 and 3 are
then used to set the twisted-pair rate and mode.
2. Twisted-Pair Rate
UP (100Base-TX) - Sets the twisted-pair rate to
100Base-TX.
DOWN (10Base-T) - Sets the twisted-pair rate to
10Base-T.
3. Twisted-Pair Mode
UP (Full-Duplex) - The twisted-pair cable
distances are constrained by the cable
requirements (see pages 1 and 2).
DOWN (Half-Duplex): - The twisted-pair cable
distances are constrained by the 512-Bit Rule (see
page 9).
DOWN
1
UP
Twisted-Pair Auto-Negotiation ON
Twisted-Pair Auto-Negotiation OFF
Twisted-pair 100Base-TX
Twisted-pair 10Base-T
DOWN
UP
2
Twisted-pair Full-Duplex
Twisted-pair Half-Duplex
DOWN
UP
3