Transition Networks C/A-CF-02(SM), C/A-CF-02 User Manual

The TRANSITION Networks ATM (Asynchronous Transfer Mode) C/A-CF-02
series Slide-In-Module media converters, designed to be installed in the TRANSITION Networks Media Conversion Center, E-MCC-1600, connect
twisted-
pair copper cable to multimode OR to singlemode fiber optic cable. NOTE: Effective cable distances are
determined by ambient RF noise and by signal loss in the cable. The fiber connection, with low signal loss and high resistance to radio frequency noise, allows extended distances between ATM devices. Twisted-pair runs are best kept as short as possible to preserve signal integrity.
C/A-CF-02
The ATM media converters provide network connection using an RJ-45 twisted-pair ATM connector and a set of RX (receive) and TX (transmit)
SC connector to multimode fiber- optic cable.
C/A-CF-02(SM)
The ATM media converters provide network connection using an RJ-45 twisted-pair ATM connector and a set of RX (receive) and TX (transmit)
SC connector to singlemode fiber- optic cable.
25/155 Mb/s ATM
Copper-to-Fiber Media Converter
USER’S GUIDE
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information
UL Listed CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33099.B
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards ATM UNI 3.1 #AF-PHY-0015 Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Five years
C/A-CF-02, C/A-CF-02(SM)
Status LEDs
Pwr (Power)
Illuminated green LED indicates connection to external AC power.
Activity
(Fiber) Steady green LED indicates the fiber port is active.
Activity
(Copper) Steady green LED indicates the twisted-pair port is active.
Link
CopperFiber
Activity
Fiber
Copper
Minneapolis, MN 55344 USA
Multimode
or Singlemode
Fiber
UTP or STP Copper
C/A-CF-02
Link
CopperFiber
Activity
Fiber
Copper
C/A-CF-02
The two active pairs in an ATM network are pins 1 & 2 and pins 7 & 8. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
1. Is the power LED on the media converter illuminated?
NO
• Is the Slide-In-Module properly connected to the Media Conversion Center chasis backplane?
• Is the Power Supply Module properly connected both to the Media Conversion Center chasis backplane and to the AC outlet?
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 2.
2. Is the Copper Activity LED illuminated?
NO
• Check UTP cables for proper connection and pin assignment. (See above.)
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 3.
3. Is the Fiber Activity LED illuminated?
NO
• Check fiber cables for proper connection.
• Verify that TX and RX cables on media converter are connected to RX and TX ports, respectively, on the other 100BASE-FX device.
• Refer to Tech Tips available at: http://www.transition.com
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
KEEP twisted-pair RUNS AS SHORT AS POSSIBLE.
• Install no more than two (2) media converters in series.
Troubleshooting the Media Converter
Installation Notes
If the ATM media converter fails, determine the answers to the following questions:
Twisted Pair #1
Twisted Pair #2
Crossover Cable
Connectors for like devices
1 2
7 8
1 2
7 8
1 2
7 8
Twisted Pair #1
Twisted Pair #2
Straight Through Cable
Connectors for unlike devices
1 2
7 8
Be certain that the twisted-pair cable is configured correctly (straight through or crossover) for site. Cable connections between an ATM switch and the
media converter must be configured as straight through. Cable connections between the media converter and a NIC must be configured as crossover.
The physical characteristics of the media cable must meet or exceed the specifications: ATM UNI 3.1 #AF-PHY-0015 Maximum number of media converters in series: 2
ATM Cable Specifications
Fiber Cable Specifications
Singlemode
Fiber Optic Cable Recommended: 9 µm singlemode fiber Fiber Optic Transmitter Power: min: -15.0
dBm max: -8.0 dBm
Fiber Optic Receiver Sensitivity: min: -31.0
dBm max: -8.0 dBm
Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 20 kilometers
multimode
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber 50 / 125 µm multimode fiber
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
Copper Cable Specifications
Category 5 wire or better is required. Either shielded twisted-pair (STP) or unshielded twisted-pair (UTP) can be used.
Category 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Impedance 100 Ω ±10% @ 10 MHz
Maximum Cable Distance: 100 meters (330 feet)
C/A-CF-02
Installing Slide-In-Module(s)
CAUTION: Wear a grounding device and observe electrostatic discharge precautions when installing Media Converter Slide-in-Module(s) in the 16-Slot Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in-Module(s).
NOTE: Slide-in-Modules can be installed in any installation slot, in any order. To install the Media Converter Slide-in-Module in the E-MCC-1600 chassis:
1. Remove Media Converter Slide-in-Module protective plate from selected installation slot by removing two screws that secure plate to front of E-MCC-1600. Retain one installation screw.
2. Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides.
NOTE: Ensure that the Media Converter Slide-in-Module is seated firmly against the backplane.
3. Secure Slide-in-Module by installing retained installation screw.
Loading...