Transition Networks C4TEF1016-100, C4TEF1014-100, C4TEF1017-100, C4TEF1018-100, C4TEF10xx-10x User Manual

...
* Typical maximum cable distance.
Actual distance is dependent upon the physical characteristics of the network.
The stand-alone version of the media converter is S4TEF10xx-10x. For more information, see the user’s guide on­line at: www.transition.com.
Installation . . . . . . . . . . . . . . . . . .2
Cable Specifications . . . . . . . . . .12
Technical Specifications . . . . . . .14
Troubleshooting . . . . . . . . . . . . .15
Contact Us . . . . . . . . . . . . . . . . .18
Compliance Information . . . . . . .19
User’s Guide
C4TEF10xx-10x
Slide-in-Module Media Converter
• RS-232 to Fiber
• (4) T1/E1 to Fiber
The C4TEF10xx-10x media converter is designed to be installed into a Transition Networks PointSystem™ chassis and can extend signals from an RS-232 data port and up to four (4) T1/E1 network ports over fiber. The RS-232 and T1/E1 interfaces are independent of each other and the signals from these ports can be sent over the fiber interface simultaneously.
The C4TEF10xx-10x is designed to be installed in pairs. For example, install one C4TEF1011-100 as the local media converter and another C4TEF1011-100 as the remote media converter.
All C4TEF10xx-10x models have the following copper connectors:
The various fiber connectors are available on separate models. Both duplex and single mode fiber optic converters are available:
Part Number Duplex Fiber-Optic - 100Base-FX C4TEF1011-100 ST, 1300 nm multimode, 2 km (1.2 miles)* C4TEF1013-100 SC, 1300 nm multimode, 2 km (1.2 miles)* C4TEF1014-100 SC, 1310 nm single mode, 20 km (12.4 miles)* C4TEF1015-100 SC, 1310 nm single mode, 40 km (24.8 miles)* C4TEF1016-100 SC, 1310 nm single mode, 60 km (37.2 miles)* C4TEF1017-100 SC, 1550 nm single mode, 80 km (49.7 miles)* C4TEF1018-100 MT-RJ, 1300 nm multimode, 2 km (1.2 miles)*
Connector Type Number Description
RS-232 one (1) 6-pin, DIN serial, 3.2 m (10 ft.)* T1 four (4) RJ-48
C4TEF1029-10x (single mode, single-fiber models are listed on page 2)
2
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
T1/E1
Link
Link
Link
Link
AIS
AIS
AIS
AIS
TX
RX
C4TEF
LKF PWR
1
2
3
4
5
6
Fiber Port
RS-232
T1/E1Ports
Part Number Fiber-Optic - single fiber, single mode, 100Base-FX
C4TEF1029-100 SC, 1310 mn (TX)/1550 nm (RX), 20 km (12.4 miles)*
C4TEF1029-101 SC, 1550 mn (TX)/1310 nm (RX), 20 km (12.4 miles)*
C4TEF1029-100 and C4TEF1029-101 are intended to be installed in the same link where one is the local converter and the other is the remote converter.
Installation
NOTE: Due to proprietary communication over fiber, the C4TEF10xx-10x is
required to be installed in pairs, where one is the local converter and the other is the remote converter.
Copper and Fiber Ports
The figure below illustrates the locations of the fiber port, the RS-232 port, and the four (4) T1/E1 ports.
NOTE: An RS-232 cable with a 6-pin DIN connector and a DB-9 connector is included with the C4TEF10xx-10x media converter.
C4TEF1029-102 SC, 1310 mn (TX)/1550 nm (RX), 40 km (24.8 miles)*
C4TEF1029-103 SC, 1550 mn (TX)/1310 nm (RX), 40 km (24.8 miles)*
C4TEF1029-102 and C4TEF1029-103 are intended to be installed in the same link where one is the local converter and the other is the remote converter.
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit, (RX) = receive
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Configuration Switches
The C4TEF10xx-10x media converter has two (2) sets of configuration switches.
• Set #1 is on the upper circuit board and sets the T1/E1 options.
• Set #2 is on the lower circuit board and sets the serial options.
Use a flat blade screwdriver to set the switches as shown:
Switch Set #1 - T1/E1 Options
1, 2, 3, 4 - Line Settings
Switches 1, 2, 3, and 4 are used to setup the line settings for the T1/E1 ports. The selected setting applies to all four (4) T1/E1 channels.
Switch Set #1: T1/E1 Options
Switch Set #2: Serial O
p
tions
Key:
up
down
DSX-1, 100 ohm, 266-399 ft. (81-122 m)
DSX-1, 100 ohm, 399-533 ft. (122-162 m)
DSX-1, 100 ohm, 0-133 ft. (0-40.5 m)
DSX-1, 100 ohm, 133-266 ft. (40.5-81 m)
1 2
DS1, 100 ohm, 0 dB LBO
DS1, 100 ohm, -7.5 dB LBO
DSX-1, 100 ohm, 533-655 ft. (162-200 m)
J1, 110 ohm, 0-655 ft. (0-200 m)
3
E1, 120 ohm
DS1, 100 ohm, -15 dB LBO
DS1, 100 ohm, -22.5 dB LBO
41234
4
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Installation -- Continued
Switch Set #1 - T1/E1 Options
5, 6, 7, 8 - Loop-Back Settings
The loop-back setting is used for installation and network debugging procedures. Each of the T1/E1 ports can be individually set for loop-back mode:
• Switch 5 controls T1/E1 port 1
• Switch 6 controls T1/E1 port 2
• Switch 7 controls T1/E1 port 3
• Switch 8 controls T1/E1 port 4
When the loop-back switch for a particular T1/E1 port is enabled, the port loops the signal from the receive port back to the transmit port. The loop-back test scenarios are described in detail on page 18.
Disable Loop-Back on T1/E1 port 1
Enable Loop-Back on T1/E1 port 1
up
5
down
Disable Loop-Back on T1/E1 port 2
Enable Loop Back on T1/E1 port 2
6
up
down
up
down
Disable Loop-Back on T1/E1 port 3
Enable Loop-Back on T1/E1 port 3
7
up
down
Disable Loop-Back on T1/E1 port 4
Enable Loop-Back on T1/E1 port 4
8
9 - Transmit AIS
up - Enables the transmit AIS (Alarm Indication Signal) on loss of the carrier signal. This function is un-framed and applies to ALL channels, both copper and fiber.
down - Disables the transmit AIS function.
10 - RS-232 Port Mode
up - Data port mode (normal operation). Transmits data to a desk top computer or other data collection device
down - Local (auxiliary) management mode. See the SNMP section (page 11) for the commands that are supported via the RS-232 connector.
up
down
Enable
Disable
9
up
down
Data port mode
Local management mode
10
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Switch Set #2 - Serial Options
1, 2, 3 - Serial Connection Speed Line Settings
Switches 1, 2, and 3 on switch set #2 are used to set the serial connection speed.
4800 baud
9600 baud
1200 baud
2400 baud
1 2 3
57600 baud
115200 baud
19200 baud
38400 baud
1 2 3
4. Enable / Disable Parity
When parity is enabled, an additional bit is added to an 8-bit signal to identify whether the signal is sent successfully. Use switch 5 to send odd or even signal parity.
up - Disable parity.
down - Enable parity.
5. Parity Select
up - Select odd serial parity.
down - Select even serial parity.
This switch is inactive if switch 4 is (up).
Disable Parity
Enable Parity
down
up
4
Odd Serial Parity
Even Serial Parity
up
5
down
6
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Installation -- Continued
Switch Set #2 - Serial Options
6 - not in use
7 - not in use
8 - not in use
9 - not in use
switches 6, 7, 8, & 9 are not in use
9876
10 - Fiber Loop-Back
up - Disabled fiber loop-back.
down - Enabled fiber loop-back.
The loop-back setting is used for installation and network debugging procedures. When the fiber loop-back function is enabled, the fiber port loops all T1/E1 signals from the receive ports back to the transmit ports. The loop-back test scenarios are described in detail on page
17.
up
down
Disables Loop-Back
Enables Loop-Back
10
7
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Hardware/Software Jumper
• The hardware/software header J11 is located on the circuit board.
• Use a small needle-nose pliers to change the jumper position—currently in the software position.
Install the Slide-in-Module
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing the C4TEF10xx-10x slide-in-module media converter. Failure to observe this caution could result in damage to, and
subsequent failure of, the slide-in-module.
1. Carefully slide the slide-in-module into two adjacent installation slots, aligning the module with the installation guides.
2. Ensure that the module is firmly seated inside the chassis.
3. Push in and rotate the panel fastener screw clockwise to secure the module to the chassis front.
Hardware The media converter mode is determined by
the switch settings (see pages 3 - 6).
Software The media converter mode is determined by
the most-recently saved, on-board microprocessor settings.
Hardware Mode
Software Mode
S
H
S
H
Installation -- Continued
Install the T1/E1 Cable
1. Locate or build ITU compliant copper cable with straight-through RJ-48 connectors installed at both ends. (See page 14 for the proper cable specifications for your network application.)
2. Connect the RJ-48 connector at one end of the cable to one of the T1/E1 ports on the C4TEF10xx-10x media converter.
3. Connect the RJ-48 connector at the other end of the cable to the T1/E1 port on the other device.
8
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Install the RS-232 Data Cable
1. Use the enclosed RS-232 data cable with a male, DIN 6-pin connector on one end and a DB-9 connector installed on the other end.
2. Connect the DIN 6-pin connector to the RS-232 port on the C4TEF10xx­10x media converter.
3. Connect the DB-9 connector at the other end of the cable to the RS-232 port on a computer or other device that is used to collect and display data.
Connect the 6-pin DIN connector to the media converter as shown.
Connect the DB-9
connector to the
computer
RS-232 data cable (enclosed)
Dry-Contact Relay
All four T1/E1 ports are equipped with an RJ-48 dry-contact relay. The relay closes if the power is lost or if any of the individual T1/E1 links are lost. The operational rating on pins 3 and 6 are 0-30 VDC, 100 mAmp (maximum).
relay
3
6
RJ-48C connector
T1/E1 port
9
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Install the Fiber Cable
1. Locate or build ITU compliant fiber cable with male, two-stranded TX to RX connectors installed at both ends.
2. Connect the fiber cables to the local C4TEF10xx-10x media converter as described:
• Connect the male TX cable connector to the female TX port.
• Connect the male RX cable connector to the female RX port.
3. Connect the fiber cables to the remote C4TEF10xx-10x media converter as described:
• Connect the male TX cable connector to the female RX port.
• Connect the male RX cable connector to the female TX port.
Connect the fiber cable to the local media converter as shown.
Connect the fiber cable
to the remote media
converter as shown
RX
TX
RX
TX
10
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Operation
Fiber Network LEDs
Use the status LEDs next to the fiber port to monitor the media converter and the fiber network connections.
LKF (fiber link)
On = Fiber link connection.
PWR (power)
On = Connection to external AC or DC power.
T1/E1 LEDs
Each T1/E1 link has a pair of LEDs embedded in the RJ-48 connector that monitor the status of the link.
LNK LED (green)
On = T1/E1 link detected.
Off = T1/E1 signal lost or no signal.
AIS LED (amber)
On = AIS (Alarm Indication Signal) detected. Failure of the device
connected to the T1/E1 port.
T1/E1
Link
Link
Link
Link
AIS
AIS
AIS
AIS
TX
RX
C4TEF
LKF PWR
1
2
3
4
5
6
Fiber LED
Link LE D
AIS LED
Power LED
11
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Operation -- Continued
Remote Management Function
The stand-alone version of this media converter, the S4TEF10xx-10x, can be remotely managed when connected via fiber cable to a local C4TEF10xx-10x slide-in-module media converter that is installed in a managed Transition Networks PointSystem™ chassis. (See the list of SNMP commands below.)
SNMP
See the on-line documentation that comes with Transition Networks FocalPoint™ software for applicable commands and usage.
Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring:
• Media converter power
• Fiber link status
• Copper link status for each T1/E1 (AIS, link)
• RS-232 status (speed, bits, parity, stop)
• All hardware switch settings
• AIS detected copper link
• Model #, serial #, PIC revision,HW revision, group string, connectors
Also, use SNMP to enter network commands that:
• Local and remote fiber loop-back.
• Local and remote T1/E1 loop-back on each channel
• T1/E1 line options (DS1, DSX-1, J1, D1, AIS)
• RS-232 settings (speed, bits, parity, stop)
• T1/E1 monitor modes and loop-back modes
• Boot-load firmware (local unit only)
The local (auxiliary) factory maintenance interface via the RS-232 connector supports the following:
• Switch selection for the RS-232 interface
• Access to all local and remote status information
• Perform all local and remote commands
• Operate at selected baud rates
13
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Cable Specifications -- Continued
T1/E1 Cable
Category 3: (minimum requirement)
Connector: RJ-48C Electrical network connection: Single 4-wire (Tip/Ring - Tip1/Ring1) Mechanical arrangement: 8-position miniature modular jack Usage: 1.544 Mb/s access lines Interface codes: 04DU9 (any applicable) Cable type:
Long Haul T1: 0db, -7.5dp, -15db, -22db E1: E1 3.0V, 120 ohm J1: 0-655’, 110 ohm DSX-1: 0-133’, 133-266’, 266-399’,
399-533’, 533-655’, 100 ohm
1
2
3
4
5
6
7
8
1
2
3
4
5
6
7
8
R
T
R1
T1
Transmit
Receive
(Not Used)
(ring) R
dry contact A
dry contact B
(tip) T
(ring) R1
(tip) T1
to the
network
from the
media converter
RS-232 Cable
(included)
Connectors: 6-pin DIN and DB-9 Gauge: 24 to 22 AWG Attenuation: 20 dB/1000 ft. @ 10 MHz Differential characteristic impedance: 100 ohm +/- 10% @ 10 MHz Maximum cable distance: <10 ft (3.2 m) @ 56 kb/s or higher
1
2
3
4
5
6
7
8
9
3
2
1
4 6
5
Signal Ground 3 & 5
Transmit Signal 1
Receive signal 2
Clear to send 9
2 Receive Data
7 Request Data
3 Transmit Data
5 Signal Ground
DIN 6-Pin DB-9
12
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Cable Specifications
The physical characteristics must meet or exceed ITU specifications.
Fiber Cable
Bit Error Rate: <10-9 Single mode fiber (recommended): 9 µm Multimode fiber (recommended): 62.5/125 µm Multimode fiber (optional): 100/140, 85/140, 50/125 µm
C4TEF1011-100 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
C4TEF1013-100 1300 nm multimode Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
C4TEF1014-100 1310 nm single mode Fiber-optic Transmitter Power: min: -15.0 dBm max: -8.0 dBm Fiber-optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm Link Budget: 16.0 dB
C4TEF1015-100
(long haul)
1310 nm single mode Fiber-optic Transmitter Power: min: -8.0 dBm max: -2.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 26.0 dB
C4TEF1016-100
(extra long haul)
1310 nm single mode
C4TEF1017-100
(long wave length)
1550 nm single mode Fiber-optic Transmitter Power: min: -5.0 dBm max: 0.0 dBm Fiber-optic Receiver Sensitivity: min: -34.0 dBm max: -7.0 dBm Link Budget: 29.0 dB
C4TEF1018-100 1300 nm multimode Fiber-optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm Fiber-optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm Link Budget: 11.0 dB
C4TEF1029-100 1310 nm (TX)/1550 nm (RX) simplex C4TEF1029-101 1550 nm (TX)/1310 nm (RX) simplex
Fiber-optic Transmitter Power: min: -13.0 dBm max: -6.0 dBm Fiber-optic Receiver Sensitivity: min: -32.0 dBm max: -3.0 dBm Link Budget: 19.0 dB
C4TEF1029-102 1310 nm (TX)/1550 nm (RX) simplex C4TEF1029-103 1550 nm (TX)/1310 nm (RX) simplex
Fiber-optic Transmitter Power: min: -8.0 dBm max: -3.0 dBm Fiber-optic Receiver Sensitivity: min: -33.0 dBm max: -3.0 dBm Link Budget: 25.0 dB
The fiber optic transmitters on this device meets Class I Laser safety requirements per IEC-825/CDRH standards and complies with 21 CFR1040.10 and 21CFR1040.11.
14
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Technical Specifications
For use with Transition Networks Model C4TEF10xx-10x or equivalent.
Standards G.703, AMI/B8ZS/HDB3
Data Rate Fiber: 100 Mb/s
Dimensions 3.4" x 5.0" x 1.75" (86 mm x 182 mm x 43 mm)
Weight 6 oz. (181 g) (approximate)
Power Consumption 6.0 watts
Environment Tmra*: 0 to 50°C (32 to 122°F )
Storage Temperature: -40 to 85°C (-40 to 185°F) Humidity: 5 to 95%, non condensing Altitude: to 10,000 feet
Warranty Lifetime
*Manufacturer’s rated ambient temperature: Tmra range for this slide-in-module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem™ chassis in which this slide-in-module will be installed.
The information contained in this user’s guide is subject to change. For the most up-to-date information on the C4TEF10xx-10x media converter, see the user’s guide on-line at: www.transition.com.
Product is certified by the manufacturer to comply with DHHS Rule 21/CFR, Subchapter J applicable at the date of manufacture.
CAUTION: Visible and invisible laser radiation when open. Do not stare into beam or view directly with optical instruments.
CAUTION: Use of controls, adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure.
15
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Troubleshooting
If the media converter fails, isolate and correct the failure by determining the answers to the following questions and then taking the indicated action:
1. Is the “PWR” LED illuminated? NO
• Is the slide-in-module installed properly in the chassis?
• Is the power cord properly installed in the chassis?
• Does the external power source provide power?
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 2.
2. Is the “LKF” LED illuminated? NO
• Check the fiber cables for proper connection.
• Verify that the TX and RX cables on the local media converter are
connected to the RX and TX ports, respectively, on the remote media converter.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 3.
3. Is the “LNK” LED on a T1port (with a copper cable installed) illuminated? NO
• Check the copper cable connected to that T1/E1 port for proper
connection.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
YES
• Proceed to step 4.
4. Is the “AIS” LED on a T1/E1 port (with a copper cable installed) illuminated? YES
• The device connected to the T1/E1 port has failed. Correct the device
failure.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Proceed to step 5.
16
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Troubleshooting -- Continued
5. Is data transfer failing on one of the T1/E1 ports? YES
• Verify the local T1/E1 connection at the local converter by starting a
local loop-back at the local converter:
- HW mode: set the local converter to T1/E1 loop-back (see page 4).
- SW mode: enter the local T1/E1 loop-back command at the local converter.
• Use a bit error test unit to run a bit error test.
• Verify the remote T1/E1 connection at the local converter by starting a remote loop-back at the local converter:
- SW mode: enter the remote T1/E1 loop-back command at the local
converter. (HW mode is not available.)
• Use a bit error test unit to run a bit error test.
• Verify the remote T1/E1 connection at the remote converter by starting a remote loop-back at the remote converter:
- SW mode: enter the remote T1/E1 loop-back command at the remote
converter. (HW mode is not available.)
• Use a bit error test unit to run a bit error test.
• Verify the local T1/E1 connection at the remote converter by starting a local loop-back at the remote converter:
- HW mode: set the remote converter to T1/E1 loop-back (see page 4).
- SW mode: enter the local T1/E1 loop-back command at the remote converter.
• Use a bit error test unit to run a bit error test.
FiberT1 T1
Local
Converter
Remote
Converter
Bit Error Test
Equipment
Remote
Device
FiberT1 T1
Local
Converter
Remote
Converter
Bit Error Tes
t
Equipment
Remote
Device
FiberT1 T1
Local
Converter
Remote
Converter
Remote
Device
Bit Error Tes
t
Equipment
FiberT1 T1
Local
Converter
Remote
Converter
Remote
Device
Bit Error Test
Equipment
17
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Troubleshooting -- Continued
6. Is data transfer failing on the fiber port? YES
• Verify the local fiber connection by starting a remote fiber loop-back:
- HW mode: set the remote converter to fiber loop-back (see page 7).
- SW mode: enter the remote fiber loop-back command.
• Use a bit error test unit to run a bit error test.
• Verify the remote fiber connection by starting a local fiber loop-back:
- HW mode: set the local converter to fiber loop-back (see page 7).
- SW mode: enter the remote fiber loop-back command.
• Use a bit error test unit to run a bit error test.
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
NO
• Contact Tech Support: 1-800-260-1312, Int’l: 00-1-952-941-7600.
FiberT1 T1
Local
Converter
Remote
Converter
Bit Error Test
Equipment
Remote
Device
FiberT1 T1
Local
Converter
Remote
Converter
Remote
Device
Bit Error Test
Equipment
18
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Contact Us
Technical Support
Technical support is available 24 hours a day. US and Canada: 1-800-260-1312 International: 00-1-952-941-7600
Transition Now
Chat live via the Web with Transition Networks Technical Support. Log onto www.transition.com and click the Transition Now link.
Web-Based Seminars
Transition Networks provides seminars via live web-based training. Log onto www.transition.com and click the Learning Center link.
E-Mail
Ask a question anytime by sending an e-mail to our technical support staff.
techsupport@transition.com
Address
Transition Networks 6475 City West Parkway Minneapolis, MN 55344, U.S.A. telephone: 952-941-7600 toll free: 800-526-9267 fax: 952-941-2322
Declaration of Conformity
Name of Mfg: Transition Networks
6475 City West Parkway, Minneapolis MN 55344 U.S.A. Model: C4TEF10xx-10x Series Media Converters Part Number(s): C4TEF1011-100, C4TEF1013-100, C4TEF1014-100,
C4TEF1015-100, C4TEF1016-100, C4TEF1017-100, C4TEF1018-100, C4TEF1029-100, C4TEF1029-101, C4TEF1029-102, C4TEF1029-103
Regulation: EMC Directive 89/336/EEC Purpose: To declare that the
C4TEF10xx-10x
to which this declaration refers is in
conformity with the following standards. EN 55022:1994 Class A; EN 55024:1998+A1+A13564:2002; FCC Part 15 Subpart B;
21 CFR subpart J; EN 61000-3-2:2001; EN 61000-4-2, 4-3, 4-4, and 4-6
I, the undersigned, hereby declare that the equipment specified above conforms to the above Directive(s) and Standard(s).
August, 2007
Stephen Anderson, Vice-President of Engineering Date
19
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Compliance Information
CISPR22/EN55022 Class A + EN55024 CE Mark
FCC Regulations
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user's own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Le présent appareil numérique n'émet pas de bruits radioélectriques dépassant les limites applicables aux appareils numériques de la Class A prescrites dans le Règlement sur le brouillage radioélectrique édicté par le ministère des Communications du Canada.
European Regulations
Warning This is a Class A product. In a domestic environment this product may cause radio
interference in which case the user may be required to take adequate measures. Achtung! Dieses ist ein Gerät der Funkstörgrenzwertklasse A. In Wohnbereichen können bei Betrieb dieses Gerätes Rundfunkstörungen auftreten, in diesem Fäll ist der Benutzer für Gegenmaßnahmen verantwortlich. Attention! Ceci est un produit de Classe A. Dans un environment domestique, ce produit risque de créer des interférences radioélectriques, il appartiendra alors à l'utilsateur de prende les measures spécifiques appropriées.
In accordance with European Union Directive 2002/96/EC of the European Parliament and of the Council of 27 January 2003, Transition Networks will accept post usage returns of this product for proper disposal. The contact information for this activity can be found in the 'Contact Us' portion of this document.
VCCI Class 1 Compliance
This equipment is in the 1st Class category (information equipment to be used in commercial and/or industrial areas) and conforms to the standards set by the Voluntary Control Council For Interference by Data Processing Equipment and Electronic Office Machines aimed at preventing radio interference in commercial and/or industrial areas. When used in a residential area or in an adjacent area thereto, interference may be caused to radio and TV receivers, etc. Read the instructions for correct handling.
Trademark Notice
All trademarks and registered trademarks are the property of their respective owners.
Copyright Restrictions
© 2005 Transition Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks. Printed in the U.S.A.
33306.C