Transition Networks C4TEF1016-100, C4TEF1014-100, C4TEF1017-100, C4TEF1018-100, C4TEF10xx-10x User Manual

...
* Typical maximum cable distance.
Actual distance is dependent upon the physical characteristics of the network.
The stand-alone version of the media converter is S4TEF10xx-10x. For more information, see the user’s guide on­line at: www.transition.com.
Installation . . . . . . . . . . . . . . . . . .2
Cable Specifications . . . . . . . . . .12
Technical Specifications . . . . . . .14
Troubleshooting . . . . . . . . . . . . .15
Contact Us . . . . . . . . . . . . . . . . .18
Compliance Information . . . . . . .19
User’s Guide
C4TEF10xx-10x
Slide-in-Module Media Converter
• RS-232 to Fiber
• (4) T1/E1 to Fiber
The C4TEF10xx-10x media converter is designed to be installed into a Transition Networks PointSystem™ chassis and can extend signals from an RS-232 data port and up to four (4) T1/E1 network ports over fiber. The RS-232 and T1/E1 interfaces are independent of each other and the signals from these ports can be sent over the fiber interface simultaneously.
The C4TEF10xx-10x is designed to be installed in pairs. For example, install one C4TEF1011-100 as the local media converter and another C4TEF1011-100 as the remote media converter.
All C4TEF10xx-10x models have the following copper connectors:
The various fiber connectors are available on separate models. Both duplex and single mode fiber optic converters are available:
Part Number Duplex Fiber-Optic - 100Base-FX C4TEF1011-100 ST, 1300 nm multimode, 2 km (1.2 miles)* C4TEF1013-100 SC, 1300 nm multimode, 2 km (1.2 miles)* C4TEF1014-100 SC, 1310 nm single mode, 20 km (12.4 miles)* C4TEF1015-100 SC, 1310 nm single mode, 40 km (24.8 miles)* C4TEF1016-100 SC, 1310 nm single mode, 60 km (37.2 miles)* C4TEF1017-100 SC, 1550 nm single mode, 80 km (49.7 miles)* C4TEF1018-100 MT-RJ, 1300 nm multimode, 2 km (1.2 miles)*
Connector Type Number Description
RS-232 one (1) 6-pin, DIN serial, 3.2 m (10 ft.)* T1 four (4) RJ-48
C4TEF1029-10x (single mode, single-fiber models are listed on page 2)
2
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
T1/E1
Link
Link
Link
Link
AIS
AIS
AIS
AIS
TX
RX
C4TEF
LKF PWR
1
2
3
4
5
6
Fiber Port
RS-232
T1/E1Ports
Part Number Fiber-Optic - single fiber, single mode, 100Base-FX
C4TEF1029-100 SC, 1310 mn (TX)/1550 nm (RX), 20 km (12.4 miles)*
C4TEF1029-101 SC, 1550 mn (TX)/1310 nm (RX), 20 km (12.4 miles)*
C4TEF1029-100 and C4TEF1029-101 are intended to be installed in the same link where one is the local converter and the other is the remote converter.
Installation
NOTE: Due to proprietary communication over fiber, the C4TEF10xx-10x is
required to be installed in pairs, where one is the local converter and the other is the remote converter.
Copper and Fiber Ports
The figure below illustrates the locations of the fiber port, the RS-232 port, and the four (4) T1/E1 ports.
NOTE: An RS-232 cable with a 6-pin DIN connector and a DB-9 connector is included with the C4TEF10xx-10x media converter.
C4TEF1029-102 SC, 1310 mn (TX)/1550 nm (RX), 40 km (24.8 miles)*
C4TEF1029-103 SC, 1550 mn (TX)/1310 nm (RX), 40 km (24.8 miles)*
C4TEF1029-102 and C4TEF1029-103 are intended to be installed in the same link where one is the local converter and the other is the remote converter.
* Typical maximum cable distance. Actual distance is dependent upon the
physical characteristics of the network. (TX) = transmit, (RX) = receive
3
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Configuration Switches
The C4TEF10xx-10x media converter has two (2) sets of configuration switches.
• Set #1 is on the upper circuit board and sets the T1/E1 options.
• Set #2 is on the lower circuit board and sets the serial options.
Use a flat blade screwdriver to set the switches as shown:
Switch Set #1 - T1/E1 Options
1, 2, 3, 4 - Line Settings
Switches 1, 2, 3, and 4 are used to setup the line settings for the T1/E1 ports. The selected setting applies to all four (4) T1/E1 channels.
Switch Set #1: T1/E1 Options
Switch Set #2: Serial O
p
tions
Key:
up
down
DSX-1, 100 ohm, 266-399 ft. (81-122 m)
DSX-1, 100 ohm, 399-533 ft. (122-162 m)
DSX-1, 100 ohm, 0-133 ft. (0-40.5 m)
DSX-1, 100 ohm, 133-266 ft. (40.5-81 m)
1 2
DS1, 100 ohm, 0 dB LBO
DS1, 100 ohm, -7.5 dB LBO
DSX-1, 100 ohm, 533-655 ft. (162-200 m)
J1, 110 ohm, 0-655 ft. (0-200 m)
3
E1, 120 ohm
DS1, 100 ohm, -15 dB LBO
DS1, 100 ohm, -22.5 dB LBO
41234
4
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Installation -- Continued
Switch Set #1 - T1/E1 Options
5, 6, 7, 8 - Loop-Back Settings
The loop-back setting is used for installation and network debugging procedures. Each of the T1/E1 ports can be individually set for loop-back mode:
• Switch 5 controls T1/E1 port 1
• Switch 6 controls T1/E1 port 2
• Switch 7 controls T1/E1 port 3
• Switch 8 controls T1/E1 port 4
When the loop-back switch for a particular T1/E1 port is enabled, the port loops the signal from the receive port back to the transmit port. The loop-back test scenarios are described in detail on page 18.
Disable Loop-Back on T1/E1 port 1
Enable Loop-Back on T1/E1 port 1
up
5
down
Disable Loop-Back on T1/E1 port 2
Enable Loop Back on T1/E1 port 2
6
up
down
up
down
Disable Loop-Back on T1/E1 port 3
Enable Loop-Back on T1/E1 port 3
7
up
down
Disable Loop-Back on T1/E1 port 4
Enable Loop-Back on T1/E1 port 4
8
9 - Transmit AIS
up - Enables the transmit AIS (Alarm Indication Signal) on loss of the carrier signal. This function is un-framed and applies to ALL channels, both copper and fiber.
down - Disables the transmit AIS function.
10 - RS-232 Port Mode
up - Data port mode (normal operation). Transmits data to a desk top computer or other data collection device
down - Local (auxiliary) management mode. See the SNMP section (page 11) for the commands that are supported via the RS-232 connector.
up
down
Enable
Disable
9
up
down
Data port mode
Local management mode
10
5
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Switch Set #2 - Serial Options
1, 2, 3 - Serial Connection Speed Line Settings
Switches 1, 2, and 3 on switch set #2 are used to set the serial connection speed.
4800 baud
9600 baud
1200 baud
2400 baud
1 2 3
57600 baud
115200 baud
19200 baud
38400 baud
1 2 3
4. Enable / Disable Parity
When parity is enabled, an additional bit is added to an 8-bit signal to identify whether the signal is sent successfully. Use switch 5 to send odd or even signal parity.
up - Disable parity.
down - Enable parity.
5. Parity Select
up - Select odd serial parity.
down - Select even serial parity.
This switch is inactive if switch 4 is (up).
Disable Parity
Enable Parity
down
up
4
Odd Serial Parity
Even Serial Parity
up
5
down
6
C4TEF10xx-10x
Technical Support: 1-800-260-1312 International: 00-1-952-941-7600 (24 hours)
Installation -- Continued
Switch Set #2 - Serial Options
6 - not in use
7 - not in use
8 - not in use
9 - not in use
switches 6, 7, 8, & 9 are not in use
9876
10 - Fiber Loop-Back
up - Disabled fiber loop-back.
down - Enabled fiber loop-back.
The loop-back setting is used for installation and network debugging procedures. When the fiber loop-back function is enabled, the fiber port loops all T1/E1 signals from the receive ports back to the transmit ports. The loop-back test scenarios are described in detail on page
17.
up
down
Disables Loop-Back
Enables Loop-Back
10
7
techsupport@transition.com -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Hardware/Software Jumper
• The hardware/software header J11 is located on the circuit board.
• Use a small needle-nose pliers to change the jumper position—currently in the software position.
Install the Slide-in-Module
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing the C4TEF10xx-10x slide-in-module media converter. Failure to observe this caution could result in damage to, and
subsequent failure of, the slide-in-module.
1. Carefully slide the slide-in-module into two adjacent installation slots, aligning the module with the installation guides.
2. Ensure that the module is firmly seated inside the chassis.
3. Push in and rotate the panel fastener screw clockwise to secure the module to the chassis front.
Hardware The media converter mode is determined by
the switch settings (see pages 3 - 6).
Software The media converter mode is determined by
the most-recently saved, on-board microprocessor settings.
Hardware Mode
Software Mode
S
H