Transition Networks B-CF-01(SC), B-CF-01(SM), B-CF-01 User Manual

MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Host Connection IBM® 317x or 327x Cluster Controller Case dimensions 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm) Shipping Weight 2 pounds (0.9 kilograms) Environment Temperature: 0-50°C (32-122°F)
Humidity 10-90%, non condensing Altitude 0-10,000 feet
input rating (see below) and output rating (regulated 9VDC at 0.5 A).
TN PN Requirement Location 3525 240 volts, 50 hertz United Kingdom 3525 230 volts, 50 hertz Europe 3518 120 volts, 60 hertz USA/Canada/Mexico 3514 100 volts, 50-60 hertz Japan
3525 240 volts, 50 hertz Australia NOTE: This product also can be powered by the Transition Networks E-MCR series media converter rack.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1998 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33093.A
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
The TRANSITION Networks 3270 Twisted Pair/Coax (Copper) to Fiber B-CF-01series media converters, designed to support all
IBM
®
3270
compliant devices, extends the signal distance of a 317x or 327x Cluster
Controller
to terminal links.
B-CF-01 series media converters allow twisted-pair copper network extension distances up to 1524 meters (762 meters each connection on two media converters) OR coax copper network extension distances up to 614 meters (307 meters each connection on two media converters) AND fiber network extension distances up to 2 kilometers on multimode fiber and up to 8 kilometers on singlemode fiber.*
STATUS LEDS Power Steady green LED
indicates connection to external AC power.
UTP/STP Blinking green LED
- Coax indicates network traffic on unshielded or shielded twisted-pair
link OR on the coaxial cable.
Fiber Blinking green LED indicates network traffic on fiber link.
Minneapolis, MN 55344 USA
3270 Copper/Fiber Media Converter
B-CF-01, B-CF-01(SC), B-CF-01(SM)
USER’S GUIDE
10BASE-T
RX
TX
Fiber
UTP/STP
Power
- Coax
B-CF-01
Provides an RJ-45 twisted-pair connector to copper cable, a BNC connector to coaxial cable, and a set of RX (receive) and TX (transmit) ST connectors to multimode fiber-optic cable.
B-CF-01(SC)
Provides an RJ-45 twisted-pair connector to copper cable, a BNC connector to coaxial cable, and an RX (receive) and TX (transmit) SC connector to multimode fiber-optic cable.
B-CF-01(SM)
Provides an RJ-45 twisted-pair connector to copper cable, a BNC connector to coaxial cable, and an RX (receive) and TX (transmit) SC connector to singlemode fiber-optic cable.
OR
*See note at top of pages 4 & 5.
Installation NOTES
To install the B-CF-01 series media converter:
1. Connect host signal to B-CF-01 media converter. NOTE: Set the configuration switch (located on the side of the
media converter) according to site requirements, using the following:
Switch 1 NOT USED Switch 2 UP = Twisted Pair
DOWN = Coax
Twisted-pair:
• Locate or build twisted-pair cables (See specifications, page 7)
with male RJ-45 plug connectors at both cable ends.
NOTE: Install TRANSITION Networks balun part number: B-4554 between RJ-45 cable and coax connector.
• Install balun at host coax connector.
• Connect male RJ-45 plug connector at one end of twisted pair
cable to balun on host coax connector.
• Connect male RJ-45 plug connector at other end of cable to
female RJ-45 connector on B-CF-01 media converter.
Coax:
• Locate or build coaxial RG-62 cables (See specifications, page
7) with male BNC connectors at both ends.
• Install one end of cable to female BNC connector on host.
• Install other end of cable to female BNC connector on media
converter.
2. Connect B-CF-01 media converter near host to B-CF-01 media converter near terminal device.
• Locate or build fiber cable that conforms to cable
specifications (See page 7) with male fiber connectors at both ends.
• Connect one end of first fiber cable to B-CF-01 media converter
TX connector.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: min: -19.0
dBm
max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm Wavelength: 850nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber Fiber Optic Transmitter Power: min: -27.0 dBm max: -17.0 dBm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -13.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 8 kilometers
TWISTED PAIR CABLE AND CONNECTOR
Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge 24 to 22 AWG Attenuation 28 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Category 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Minimum UTP/STP Cable Distance: 1.8 meters (6 feet) Maximum UTP/STP Cable Distance: 762 meters (2500 feet)
RG-62 Cable
Cable Characteristics:
Cable type: Coaxial RG-62 Impedance: 93 Ω @ 10 MHz Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz
Maximum Cable Distance: 307 meters (1000 feet) Minimum Distance/Connection: 1.8 meters (6 feet)
7
2
All cable connections to the B-CF-01 MUST be AT LEAST 1.8 meters (6 feet) in length.
B-CF-01
3 4
5 6
RJ-45 connector
Straight Through Cable
3 4
5 6
RJ-45 connector
NOTE: The active pair in a twisted-pair copper 3270-compliant network are pins 4 & 5. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.