Transition Networks ARCNET C/AR-CF-01(SC), ARCNET C/AR-CF-01(SM), ARCNET C/AR-CF-01 User Manual

MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards ANSI/ATA 878 Delay 300ns one-way Case dimensions 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm) Shipping Weight 2 pounds (0.9 kilograms) Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Five years CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when installing Media Converter Slide-in-Module(s) in the Media Conversion Center. Failure to observe this caution could result in damage to, and subsequent failure of, the Media Converter Slide-in­Module(s).
NOTE: Media Converter Slide-in-Modules can be installed in any installation slot, in any order.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant o part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
ARCNET is a registered trademark of Datapoint Corporation. All registered trademarks and trademarks are the property of their respective owners. 33054.A
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-
Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
The TRANSITION Networks ARCNET®RJ-11 Copper/Fiber Media Converter (series C/AR-CF-01), designed to be installed in the TRANSITION Networks Media Conversion Center, E-MCC-1600, extends the signal distance of an ARCNET
®
segment or node link up to 2 kilometers over fiber*, up to 100 meters over twisted-pair copper in a star topology, and up to 120 meters over twisted-pair copper in a bus topology. A switch on the media converter allows the media converter to terminate the link or node signal.
STATUS LEDS
Power Steady green LED indicates
connection to external AC power.
UTP/STP Blinking green LED
indicates network traffic on unshielded or shielded twisted-pair link.
Fiber Blinking green LED indicates network traffic on fiber link. *Consider carefully the network constraints imposed by the maximum latency
response time of installed equipment. Some equipment cannot handle the extended response time that 2 kilometers of fiber introduces.
Minneapolis, MN 55344 USA
ARCNET®RJ-11 Copper/Fiber
Slide-In-Module Media Converters
C/AR-CF-01, C/AR-CF-01(SC), C/AR-CF-01(SM)
USER’S GUIDE
10BASE-T
RX
TX
Fiber
Power
UTP/STP
C/AR-CF-01
Provides an RJ-11 connector to twisted­pair copper cable and a set of RX (receive) and TX (transmit) ST connectors to multimode fiber-optic cable.
C/AR-CF-01(SC)
Provides an RJ-11 connector to twisted­pair copper cable and an RX (receive) and TX (transmit) SC connector to multimode fiber-optic cable.
C/AR-CF-01(SM)
Provides an RJ-11 connector to twisted­pair copper cable and an RX (receive) ST and TX (transmit) SC connector to singlemode fiber-optic cable.
Power Modules
Media Conversion Center
E-MCC-1600
Power
In Use
Power
In Use
1
2
Management Module
Power
Link
TX
RX
Fiber
Multimode - to 2 kilometers Singlemode - to 8 kilometers
UTP/STP
STAR - to 100 meters (no minimum)
BUS - to 120 meters (1.8 meter minimum
Installation NOTES
Install Slide-In-Module Media Converter
To install the Media Converter Slide-in-Module in the E-MCC-1600 chassis:
• Remove Media Converter Slide-in-Module protective plate from selected installation slot by removing two screws that secure plate to front of E-MCC-1600. Retain one installation screw.
• Carefully slide Media Converter Slide-in-Module into installation slot, aligning Media Converter Slide-in-Module with installation guides.
NOTE: Ensure that the Media Converter Slide-in-Module is firmly seated against the backplane.
• Secure Slide-in-Module by installing retained installation screw.
Install Twisted-pair Copper
STAR TOPOLOGY
• MAXIMUM twisted-pair segment to active hub is 100 meters (300 feet); minimum does not apply.
BUS TOPOLOGY
• Devices attached to twisted-pair bus must be located AT LEAST six (6) feet apart.
• MAXIMUM twisted-pair bus length is 120 meters (400 feet).
• Device(s) attached to EACH END of bus must be terminated. NOTE: If the media converter is installed at one end of the bus, use the configuration switch to terminate the media converter.
CONFIGURATION SWITCH
NOTE: Set configuration switch (located on the side of media converter) according to site installation requirements:
Switch 1 NOT USED Switch 2 UP = OFF Media converter TRANSFERS signal
DOWN = ON Media converter TERMINATES signal.
Install Fiber
Connect one end of first fiber cable to C/AR-CF-01 media converter TX connector. Connect other end of that fiber cable to second C/AR-CF-01 media converter RX connector. Connect one end of second fiber cable to C/AR-CF-01 media converter RX connector. Connect other end of that fiber cable to C/AR­CF-01 media converter TX connector.
Power Slide-In-Module Media Converter
Locate correct power supply adapter for site installation. Connect media converter power connector at end of power supply adapter cord to C/AR-CF-01 media converter power receptacle. Connect 2-prong or 3-prong external power connector on other end of power supply adapter cord to external AC power.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: min: -19.0
dBm
max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm Wavelength: 850nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber Fiber Optic Transmitter Power: min: -27.0
dBm
max: -17.0 dBm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -13.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 8 kilometers
TWISTED PAIR CABLE
Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge 24 to 22 AWG Attenuation 28 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Category 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
BUS TOPOLOGY
Minimum Node-Node Cable Distance: 1.8 meters (6 feet) Maximum Cable Distance: 120 meters (400 feet) Maximum Number of Nodes: 8
STAR TOPOLOGY
Minimum Cable Distance: 0 meters (0 feet) Maximum Cable Distance: 100 meters (330 feet)
3
2
C/AR-CF-01
2 3
4 5
RJ-11 connector
Straight Through Cable
2 3
4 5
RJ-11 connector
NOTE: The active pair in a twisted-pair copper ARCNET
®
-compliant network are pins 3 & 4. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.
Loading...