MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards ANSI/ATA 878 Case dimensions 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm) Shipping Weight 2 pounds (0.9 kilograms) Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
input rating (see below) and output rating (regulated 9VDC at 0.5 A).
TN PN Requirement Location 3525 240 volts, 50 hertz United Kingdom 3525 230 volts, 50 hertz Europe 3518 120 volts, 60 hertz USA/Canada/Mexico 3514 100 volts, 50-60 hertz Japan
3525 240 volts, 50 hertz Australia NOTE: This product also can be powered by the Transition Networks E-MCR series media converter rack.
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in damage to the public telephone network.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33053.A
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
The TRANSITION Networks ARCNET®RJ-11 Copper/Fiber Media Converter (AR-CF-01) extends the signal distance of an ARCNET
®
segment or node
link. AR-CF-01 series media converters _________________
STATUS LEDS Power Steady green LED
indicates connection to external AC power.
UTP/STP Blinking green LED
indicates network traffic on unshielded or shielded twisted-pair link.
Fiber Blinking green LED indicates network traffic on fiber link.
Minneapolis, MN 55344 USA
ARCNET®RJ-11 Copper/Fiber Media Converter
AR-CF-01, AR-CF-01(SC), AR-CF-01(SM)
USER’S GUIDE
10BASE-T
RX
TX
Fiber
Power
UTP/STP
AR-CF-01
Provides an RJ-11 twisted-pair connector to copper cable and a set of RX (receive) and TX (transmit) ST connectors to multimode fiber-optic cable.
AR-CF-01(SC)
Provides an RJ-11 twisted-pair connector to copper cable and an RX (receive) and TX (transmit) SC connector to multimode fiber-optic cable.
AR-CF-01(SM)
Provides an RJ-11 twisted-pair connector to copper cable and an RX (receive) ST and TX (transmit) SC connector to singlemode fiber- optic cable.
AR-CF-01
ArcNet
Fiber to Twisted Pair
Media Converter
®
Installation NOTES
To install the AR-CF-01 series media converter:
1. Connect host signal to AR-CF-01 media converter. NOTE: Set the configuration switch (located on the side of the
media converter) according to site requirements, using the following:
Switch 1 NOT USED Switch 2 UP = Twisted Pair
DOWN = Coax
Twisted-pair:
• Locate or build twisted-pair cables (See specifications, page 7)
with male RJ-11 plug connectors at both cable ends.
NOTE: Install TRANSITION Networks balun part number: B-4554 between RJ-11 cable and coax connector.
• Install balun at host coax connector.
• Connect male RJ-11 plug connector at one end of twisted pair
cable to balun on host coax connector.
• Connect male RJ-11 plug connector at other end of cable to
female RJ-11 connector on AR-CF-01 media converter.
Coax:
• Locate or build coaxial RG-62 cables (See specifications, page
7) with male BNC connectors at both ends.
• Install one end of cable to female BNC connector on host.
• Install other end of cable to female BNC connector on media
converter.
2. Connect AR-CF-01 media converter near host to AR-CF-01 media converter near terminal device.
• Locate or build fiber cable that conforms to cable
specifications (See page 7) with male fiber connectors at both ends.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE AND CONNECTOR SPECIFICATIONS
Cable Characteristics:
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber 50 / 125 µm multimode fiber
Fiber Optic Transmitter Power: Average power: -15.0 dBm
Peak power:-12.0 dBm ±1dBm
Fiber Optic Receiver Sensitivity: Maximum sensitivity: -27.4 dBm
Bit error rate: 10
-10
Maximum Fiber Cable Distance: 3000 meters (10,000 feet) Connector Characteristics:
ST type connectors (SMA type available upon request)
TWISTED PAIR CABLE AND CONNECTOR SPECIFICATIONS
Cable Characteristics:
Category 3 wire or better is required; category 5 wire is recommended. Either shielded twisted pair (STP) or unshielded twisted pair (UTP) can be used. DO NOT USE FLAT OR SILVER SATIN WIRE.
Category 3:
Gauge 24 to 22 AWG Attenuation 28 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Category 5:
Gauge 24 to 22 AWG Attenuation 20 dB/1000’ @ 10 MHz Differential Characteristic Impedance 100 ±10% @ 10 MHz
Minimum UTP/STP Cable Distance: 7.6 meters (25 feet) Maximum UTP/STP Cable Distance: 762 meters (2500 feet) Connector Characteristics:
RJ-11 connector
7
2
All cable connections to the AR-CF-01 MUST be AT LEAST 7.6 meters (25 feet) in length.
AR-CF-01
2 3
4 5
RJ-11 connector
Straight Through Cable
2 3
4 5
RJ-11 connector
NOTE: The active pair in a twisted-pair copper ARCNET
®
-compliant network are pins 3 & 4. Use only dedicated wire pairs (such as blue/white & white/blue, orange/white & white/orange) for the active pins.