Transition Networks AR-CF-02, AR-CF-02SM, AR-CF-02SC User Manual

MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards ANSI/ATA 878 Delay 300ns one-way Case dimensions 4.75" x 3.0" x 1.0" (119mm x 76mm x 25mm) Shipping Weight 2 pounds (0.9 kilograms)
Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing Altitude 0-10,000 feet
Warranty Five years
Power Supply Requirements Replace power supply with only the equivalent
input rating (see below) and output rating (regulated 9VDC at 0.2 A).
TN PN Requirement Location 3525 240 volts, 50 hertz United Kingdom 3525 230 volts, 50 hertz Europe 3518 120 volts, 60 hertz USA/Canada/Mexico 3514 100 volts, 50-60 hertz Japan
3525 240 volts, 50 hertz Australia NOTE: This product also can be powered by the Transition Networks E-MCR series media converter rack.
Compliance Information
UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
Copyright Restrictions
© 1999 TRANSITION Networks. All rights reserved. No part of this work may be reproduced or used in any form or by any means – graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
ARCNET is a registered trademark of Datapoint Corporation. All registered trademarks and trademarks are the property of their respective owners. 33095.B
The TRANSITION Networks ARCNET®Coax Copper/Fiber Media Converter (AR-CF-02) extends the signal distance of an ARCNET®segment or node link u p t o 2 kilometers over fiber*, up to 600 meters over coax cable in a star topology, and up to 300 meters over coax cable in a bus topology.
A switch on the media converter allows the media converter to be used to terminate the link or node signal.
STATUS LEDS
Power Steady green LED indicates connection to external AC power. Coax Blinking green LED
indicates network traffic on coaxial cable link.
Fiber Blinking green LED
indicates network traffic on fiber link.
*Consider carefully the network constraints imposed by the maximum latency response time of installed equipment. Some equipment cannot handle the extended response time that 2 kilometers of fiber introduces.
Minneapolis, MN 55344 USA
ARCNET®Coax C opper/Fiber Media Converter
AR-CF-02, AR-CF-02(SC), AR-CF-02(SM)
USER’S GUIDE
AR-CF-02
Provides a BNC connector to coaxial cable and a set of RX (receive) and TX (transmit) ST connectors to multimode fiber-optic cable.
AR-CF-02(SC)
Provides a BNC connector to coaxial cable and an RX (receive) and TX (transmit) SC connector to multimode fiber-optic cable.
AR-CF-02(SM)
Provides a BNC connector to coaxial cable and an RX (receive) ST and TX (transmit) SC connector to singlemode fiber-optic cable.
®
ArcNet
Fiber to Coax
Media Converter
TX
RX
Fiber
Power
AR-CF-02
10BASE-T
Coax
Installation NOTES
Install Coax Copper
STAR TOPOLOGY
MAXIMUM coax segment to active hub is 600 meters (2000 feet) on RG-62 cable; minimum does not apply.
BUS TOPOLOGY
Devices attached to coax bus must be located AT LEAST six (6) feet apart.
MAXIMUM coax bus length is 300 meters (1000 feet); minimum is 1.8 meters (6 feet).
Device(s) attached to EACH END of bus must be terminated. NOTE: If the media converter is installed at one end of the bus, use the configuration switch to terminate the media converter.
CONFIGURATION SWITCH
NOTE: Set configuration switch (located on the side of media converter) according to site installation requirements:
Switch 1 NOT USED Switch 2 UP = OFF Media converter TRANSFERS signal
DOWN = ON Media converter TERMINATES signal.
Install Fiber
Connect one end of first fiber cable to AR-CF-02 media converter TX connector.
Connect other end of that fiber cable to second AR-CF-02 media converter RX connector.
Connect one end of second fiber cable to AR-CF-02 media converter RX connector.
Connect other end of that fiber cable to AR-CF-02 media converter TX connector.
Power
Locate correct power supply adapter for site installation.
Connect media converter power connector at end of power
supply adapter cord to AR-CF-02 media converter power receptacle.
Connect 2-prong or 3-prong external power connector on
other end of power supply adapter cord to external AC power.
CABLE SPECIFICATIONS
The physical characteristics of the cable must meet or exceed the following:
FIBER CABLE
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber Fiber Optic Transmitter Power: min: -19.0
dBm
max: -14.0 dBm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -14.0 dBm Wavelength: 850nM Bit error rate: 10
-9
Maximum Cable Distance: 2 kilometers
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber Fiber Optic Transmitter Power: min: -27.0 dBm max: -17.0 dBm Fiber Optic Receiver Sensitivity: min: -32.5 dBm max: -13.0 dBm Wavelength: 1300nM Bit error rate: 10
-9
Maximum Cable Distance: 8 kilometers
COAX CABLE/STAR TOPOLOGY
RG-62 Cable
Cable Characteristics:
Cable type: Coaxial RG-62/u Impedance: 75 Ω @ 10 MHz Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz Maximum Attenuation: 5.5 dB/1000 feet
Maximum Cable Distance: 600 meters (2000 feet) Minimum Distance/Connection: 0 meters (0 feet)
RG-59 Cable
Cable Characteristics:
Cable type: Coaxial RG-59/u Impedance: 93 Ω @ 10 MHz Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz Maximum Attenuation: 7.0 dB/1000 feet
Maximum Cable Distance: 450 meters (1500 feet)
Minimum Distance/Connection: 0 meters (0 feet)
COAX CABLE/BUS TOPOLOGY
RG-62 Cable
Cable Characteristics:
Cable type: Coaxial RG-62/u Impedance: 93 Ω @ 10 MHz Mutual Capacitance: 13 pF/ft ±20% @ 10 MHz Maximum Attenuation: 5.5 dB/1000 feet
Maximum Cable Distance: 300 meters (1000 feet) Minimum Distance/Connection: 1.8 meters (6 feet)
AR-CF-02