The TRANSITION Networks ATM (Asynchronous Transfer Mode) copper-tofiber media converters connect twisted-pair copper cable network segments to
multimode fiber optic cable network segments (using A-CF-01) OR to
singlemode fiber optic cable network segments (using A-CF-01(SM)).
The ATM media converters provide network connection using an RJ-45 twistedpair ATM connector and a set of RX (receive) and TX (transmit) SC-type ATM fiber
connectors. NOTE: Effective cable distances are determined by ambient RF noise
and by signal loss in the cable. The fiber connection, with low signal loss and high
resistance to radio frequency noise, allows extended distances between ATM
devices. Twisted-pair runs are best kept as short as possible to preserve signal
integrity.
25/155 Mb/s ATM
Copper-to-Fiber Media Converter
USER’S GUIDE
Minneapolis, MN 55344 USA
CAUTION: RJ connectors are NOT INTENDED FOR CONNECTION TO THE
PUBLIC TELEPHONE NETWORK. Failure to observe this caution could result in
damage to the public telephone network.
Compliance Information
UL Listed
CISPR/EN55022 Class A
FCC Regulations
This equipment has been tested and found to comply with the limits for a class A digital device, pursuant
to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful
interference when the equipment is operated in a commercial environment. This equipment generates,
uses, and can radiate radio frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at the user’s own expense.
Canadian Regulations
This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on
the radio interference regulations of the Canadian Department of Communications.
European Regulations
Warning
This is a Class A product. In a domestic environment this product may cause radio interference in which
case the user may be required to take adequate measures.
Copyright Restrictions
© 1997 TRANSITION Networks.
All rights reserved. No part of this work may be reproduced or used in any form or by any means –
graphic, electronic, or mechanical – without written permission from TRANSITION Networks.
Trademark Notice
All registered trademarks and trademarks are the property of their respective owners. 33021.D
Der Anschluss dieses Gerätes an ein öffentlickes Telekommunikationsnetz in den EG-Mitgliedstaaten
verstösst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91/263/EWG zur
Angleichung der Rechtsvorschriften der Mitgliedstaaten über Telekommunikationsendeinrichtungen
einschliesslich der gegenseitigen Anerkennung ihrer Konformität.
MEDIA CONVERTER TECHNICAL SPECIFICATIONS
Standards ATM UNI 3.1 #AF-PHY-0015
Case dimensions 3.9" x 3.0" x 1.0" (99mm x 76mm x 25mm)
Environment Temperature: 0-40°C (32° to 104° F )
Humidity 10-90%, non condensing
Altitude 0-10,000 feet
Warranty Lifetime
A-CF-01, A-CF-01(SM)
Status LEDs on the connector side of the media converter provide the following
information:
Pwr (Power) Illuminated
green LED indicates
connection to external
AC power.
Activity
(Fiber) Steady green LED
indicates the fiber port is active.
Activity
(Copper) Steady green LED indicates the twisted-pair port is active.
Power Supply Requirements Replace power supply with only the equivalent input
rating (see below) and output rating (regulated 9VDC at 0.5 A).
TN PN
Requirement Location
3517 240 volts, 50 hertz United Kingdom
3516 230 volts, 50 hertz Europe
3518 120 volts, 60 hertz USA/Canada/Mexico
3514 100 volts, 50-60 hertz Japan
3515 240 volts, 50 hertz Australia
UTP
A-CF-01
Fiber
Activity
Fiber
Copper
Link
CopperFiber
Straight Through/Crossover Cable Requirements and Pin Specifications
The two active pairs in an
ATM network are pins 1 & 2
and pins 7 & 8. Use only
dedicated wire pairs (such as
blue/white & white/blue,
orange/white & white/orange)
for the active pins.
1. Is the power LED on the media converter illuminated?
NO
• Is the power adapter the proper type of voltage and cycle frequency for your AC outlet?
NOTE: Refer to the “Power Supply Requirements” on the back page.
• Is the power adapter properly installed in the media converter and in the outlet?
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 2.
2. Is the TX Activity LED illuminated?
NO
• Check UTP cables for proper connection and pin assignment. (See above.)
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Proceed to step 3.
3. Is the Fiber Activity LED illuminated?
NO
• Check fiber cables for proper connection.
• Verify that TX and RX cables on media converter are connected to RX and TX ports,
respectively, on the other 100BASE-FX device.
• Refer to Tech Tips available at: http://www.transition.com
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
YES
• Contact Technical Support at (800) 260-1312/ (800) LAN-WANS.
• KEEP TWISTED-PAIR RUNS AS SHORT AS POSSIBLE.
• Connect the power supply cable to the media converter BEFORE connecting to the outlet.
• Install unit with PSU provided. (Output 9 VDC regulated, 500 mA).
Troubleshooting the Media Converter
Installation Notes
If the ATM media converter fails, determine the answers to the following questions:
Be certain that the twisted-pair cable is configured
correctly (straight through or crossover) for site. Cable
connections between an ATM switch and the media converter must
be configured as straight through. Cable connections between the
media converter and a NIC must be configured as crossover.
The physical characteristics of the media cable must meet or exceed the
specifications: ATM UNI 3.1 #AF-PHY-0015
Maximum number of media converters in series: 2
ATM CABLE SPECIFICATIONS
FIBER CABLE SPECIFICATIONS
SINGLEMODE
Fiber Optic Cable Recommended: 9 µm singlemode fiber
Fiber Optic Transmitter Power: min: -15.0
dBm max: -8.0 dBm
Fiber Optic Receiver Sensitivity: min: -31.0 dBm max: -8.0 dBm
Wavelength: 1300nM
Bit error rate: ≤10
-9
Maximum Cable Distance: 20 kilometers
MULTIMODE
Fiber Optic Cable Recommended: 62.5 / 125 µm multimode fiber
Optional: 100 / 140 µm multimode fiber
85 / 125 µm multimode fiber
50 / 125 µm multimode fiber
Fiber Optic Transmitter Power: min: -19.0 dBm max: -14.0 dBm
Fiber Optic Receiver Sensitivity: min: -30.0 dBm max: -14.0 dBm
Wavelength: 1300nM
Bit error rate: ≤10
-9
COPPER CABLE SPECIFICATIONS
Category 5 wire or better is required. Either shielded twisted-pair (STP) or
unshielded twisted-pair (UTP) can be used. DO NOT USE FLAT OR SILVER
SATIN WIRE.
Category 5:
Gauge 24 to 22 AWG
Attenuation 20 dB/1000’ @ 10 MHz
Impedance 100 Ω ±10% @ 10 MHz
Maximum Cable Distance: 100 meters (330 feet)
A-CF-01
<100 meters
25 Mb/s or 155 Mb/s ATM Switch
straight-through
Twisted
Pair #1
Twisted
Pair #2
Straight Through Cable
1
2
7
8
Connectors for unlike devices
2 kilometers - multimode
20 kilometers - singlemode
1
Twisted
Pair #1
2
7
Twisted
Pair #2
8
Connectors for like devices
Crossover Cable
1
2
7
8
crossover
<100 meters
1
2
7
8
Fileserver