Transforming Technologies IN5130 User Manual

T R A N S F O R M I N G T E C H N O L O G I E S , L L C
O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L
Ptec™
Static Eliminators
Overhead Ionizing Blower
Model IN5130
Contents
1 Description
Model IN5130 1
About Ptec™ Technology 1 Features 1
Power Requirements 2
2 Operation and Use
Environmental Conditions 2
Set-up and Placement 2 Mounting 3 Power Connection 3
3 Maintenance
Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replacement 5 Service 6 Troubleshooting 6
4 Specifications 7 5 Service and Warranty 8
6 IN5130 Line Drawing 9
Description
Overhead Blower Model IN5130
The Model IN5130 68KHz AC overhead air ionizer is designed to cover a complete workstation and to protect sensitive electronic components from damage due to elec­trostatic discharge (ESD). Using AC corona technology to
make the air more conductive, Ptec™ ionizers produce a
balanced stream of positive and negative air ions that never need calibration. These devices are used in many industries and manufacturing applications where static electricity is a problem.
About Ptec™ Technology
A specialized piezoelectric high voltage transformer
makes Ptec™ ionizers among the most reliable products available. Ptec™ ionizers are designed to remain in bal-
ance and to alarm when the HV output affects perform­ance. The model IN5130 overhead static eliminator pro­duces a 68KHz AC output of approximately 2200V and a continuous stream of balanced air ions. Ionizers that use
Ptec™ technology do not require calibration and only mini-
mal maintenance.
Features
On the front panel of the IN5130 are six LEDs. Three green LEDs indicate that power is applied to each of the
three Ptec™ HV transformers. The red LEDs illuminate
when an alarm condition occurs. A variable fan speed control and on-off switch are also on the front panel. The side panel of the ionizer has the IEC power input connec­tor.
1
Features cont’d.
Complete workstation protection. Rapidly decays static charges. (1KV to 100V, < 6 sec.
@ 24”).
Excellent ion balance, 0 +10V. Stable AC technology. Ionization indicator light. HV alarm (red) lights. No periodic adjustments. Durable, replaceable tungsten alloy emitter points. Removable front grill. Adjustable air volume.
Power Requirements
The Model IN5130 High Frequency AC overhead air ionizer is powered by an internal DC switching power sup­ply that operates from 100-240 VAC 50/60 Hz. The output of the supply is +24 VDC @ 1.5 AMP.
Operation and Use
Environmental Conditions
The IN5130 can be operated in areas where humidity is 20-70% RH (Non-condensing). Excess humidity may af­fect ionizer performance. The temperature range for the IN5130 is 65-78°F (18-25°C).
Set-up and Placement
2
Loading...
+ 8 hidden pages