![](/html/7e/7e1f/7e1fd954d4305f43b3cb787f82bf1ad91856b557ca8271b48a7d5e158e5bf35e/bg1.png)
T R A N S F O R M I N G T E C H N O L O G I E S , L L C
O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L
Ptec™
Static Eliminators
Overhead Ionizing Blower
Model IN5130
Instruction Manual
![](/html/7e/7e1f/7e1fd954d4305f43b3cb787f82bf1ad91856b557ca8271b48a7d5e158e5bf35e/bg2.png)
Contents
1 Description
Model IN5130 1
About Ptec™ Technology 1
Features 1
Power Requirements 2
2 Operation and Use
Environmental Conditions 2
Set-up and Placement 2
Mounting 3
Power Connection 3
3 Maintenance
Periodic Maintenance 4
Cleaning Exterior 4
Cleaning Emitter Points 4
Emitter Point Replacement 5
Service 6
Troubleshooting 6
4 Specifications 7
5 Service and Warranty 8
6 IN5130 Line Drawing 9
![](/html/7e/7e1f/7e1fd954d4305f43b3cb787f82bf1ad91856b557ca8271b48a7d5e158e5bf35e/bg3.png)
Description
Overhead Blower Model IN5130
The Model IN5130 68KHz AC overhead air ionizer is
designed to cover a complete workstation and to protect
sensitive electronic components from damage due to electrostatic discharge (ESD). Using AC corona technology to
make the air more conductive, Ptec™ ionizers produce a
balanced stream of positive and negative air ions that
never need calibration. These devices are used in many
industries and manufacturing applications where static
electricity is a problem.
About Ptec™ Technology
A specialized piezoelectric high voltage transformer
makes Ptec™ ionizers among the most reliable products
available. Ptec™ ionizers are designed to remain in bal-
ance and to alarm when the HV output affects performance. The model IN5130 overhead static eliminator produces a 68KHz AC output of approximately 2200V and a
continuous stream of balanced air ions. Ionizers that use
Ptec™ technology do not require calibration and only mini-
mal maintenance.
Features
On the front panel of the IN5130 are six LEDs. Three
green LEDs indicate that power is applied to each of the
three Ptec™ HV transformers. The red LEDs illuminate
when an alarm condition occurs. A variable fan speed
control and on-off switch are also on the front panel. The
side panel of the ionizer has the IEC power input connector.
1
![](/html/7e/7e1f/7e1fd954d4305f43b3cb787f82bf1ad91856b557ca8271b48a7d5e158e5bf35e/bg4.png)
Features cont’d.
Complete workstation protection.
Rapidly decays static charges. (1KV to 100V, < 6 sec.
@ 24”).
Excellent ion balance, 0 +10V.
Stable AC technology.
Ionization indicator light.
HV alarm (red) lights.
No periodic adjustments.
Durable, replaceable tungsten alloy emitter points.
Removable front grill.
Adjustable air volume.
Power Requirements
The Model IN5130 High Frequency AC overhead air
ionizer is powered by an internal DC switching power supply that operates from 100-240 VAC 50/60 Hz. The output
of the supply is +24 VDC @ 1.5 AMP.
Operation and Use
Environmental Conditions
The IN5130 can be operated in areas where humidity
is 20-70% RH (Non-condensing). Excess humidity may affect ionizer performance. The temperature range for the
IN5130 is 65-78°F (18-25°C).
Set-up and Placement
2