![](/html/35/35e5/35e58613def0c8c405084cc3921b601ac7a999aaea67bc8f1602ac621042ad36/bg1.png)
T R A N S F O R M I N G T E C H N O L O G I E S , L L C
O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L
Ptec™
Static Eliminators
Benchtop Blower
Model IN5120
Instruction Manual
![](/html/35/35e5/35e58613def0c8c405084cc3921b601ac7a999aaea67bc8f1602ac621042ad36/bg2.png)
Contents
1 Description
Model IN5120 1
About Ptec™ Technology 1
Features 1
Power Requirements 2
2 Operation and Use
Environmental Conditions 2
Set-up and Placement 3
Power Connection 3
3 Maintenance
Periodic Maintenance 4
Cleaning Exterior 4
Cleaning Emitter Points 4
Emitter Point Replacement 5
Bracket Removal 6
Service 6
Troubleshooting 6
4 Specifications 7
5 Service and Warranty 8
6 IN5120 Line Drawing 9
![](/html/35/35e5/35e58613def0c8c405084cc3921b601ac7a999aaea67bc8f1602ac621042ad36/bg3.png)
Description
In-tool Ionizing Blower Model IN5120
The Model IN5120 68KHz AC in-tool air ionizer is a
small, efficient static elimination device with variable fan
speed for protecting electronic components and general
static protection. Using AC corona technology, to make
the air more conductive, Ptec™ ionizers produce a bal-
anced stream of positive and negative air ions that never
need calibration. These devices are used in many industries and manufacturing applications where static electricity is a problem.
About Ptec™ Technology
A specialized piezoelectric high voltage transformer
makes Ptec™ ionizers among the most reliable ionizers
manufactured. Small, lightweight and stable, Ptec™ prod-
ucts are designed to remain in balance and to alarm when
the HV output affects performance. The model IN5120
benchtop static eliminator produces a 68KHz AC output of
approximately 2200V and a continuous stream of balanced air ions.
Ionizers that use Ptec™ technology do not require
calibration and only minimal maintenance.
Features
On the front panel of the IN5120 are two LEDs. The
green LED indicates that power is applied to the unit. The
red LED is illuminated when an alarm condition occurs. A
variable fan speed control, on-off switch, and removable
finger guard are also on the front panel.
1
![](/html/35/35e5/35e58613def0c8c405084cc3921b601ac7a999aaea67bc8f1602ac621042ad36/bg4.png)
The rear panel of the ionizer has the 24 VDC power input
connector and a grounding point.
Physically small and light.
Rapidly decays static charges.
Excellent ion balance and ionization performance.
Ionization (green) and HV alarm (red) lights.
No periodic adjustments.
Durable, replaceable tungsten alloy emitter points.
Removable front grill.
Adjustable air volume.
Power Requirements
The Model IN5120 High frequency AC benchtop air
ionizer is powered by an external DC switching power supply that operates from 100-240 VAC 50/60 Hz. The output
of the supply is +24 VDC @ 500 mA.
The IN5120 blower operates on an input of +24 VDC,
7W.
Operation and Use
Environmental Conditions
The IN5120 can be operated in areas where humidity
is 20-70% RH (Non-condensing). Excess humidity may affect ionizer performance. The temperature range for the
IN5120 is 65-78°F (18-25° C).
2