1 Description
Model IN4000 1
About Ptec™ Technology 1 Features 1
Power Requirements 2
2 Operation and Use
Environmental Conditions 2
Set-up and Placement 2 Mounting 3 Power and Gas Connection 3
3 Maintenance
Periodic Maintenance 4 Cleaning Exterior 4 Cleaning Emitter Points 4 Emitter Point Replacement 5 Service 6 Troubleshooting 6
4 Specifications 7 5 Service and Warranty 8
6 IN4000 Line Drawing 9
Description
Ionizing Air Nozzle Model IN4000
The IN4000 Airflex ionizer combines exceptionally fast static decay capability with excellent balance stability, all in a small footprint. Designed to protect most static sensi­tive devices, the IN4000 uses a specialized piezoceramic
technology that makes all the Ptec™ ionizers so reliable.
The height and angle of the nozzle can be easily adjusted with a metal snake shape tube ,which is very convenient to operate. The main unit of the device is equipped with a small HV power unit. No external HV power unit and HV wiring is needed.
About Ptec™ Technology
A specialized piezoelectric high voltage transformer
makes Ptec™ ionizers among the most reliable products
available. Ptec™ ionizers are designed to remain in bal-
ance and to alarm when the HV output affects perform­ance. The model IN4000 ionizing air nozzle produces a 68KHz AC output of approximately 2200V and a continu­ous stream of balanced air ions. Ionizers that use Ptec™ technology do not require calibration and only minimal maintenance.
Features
The IN4000 features the inherently stable output of all
Ptec™ Ionizers and high frequency AC (68KHz) ion emis-
sion. The flexible metal neck, with multiple nozzle options allows for easy operation and service of emitters. A foot switch and .01 micron filter combine to deliver clean air at the correct pressure when needed.
1
Features cont’d.
Small ,light design in shape. No extra power unit is needed. The device incorporates with an ultra-small HV power unit. It
has no HV wiring, so it is safe and convenient to operate.
The height and angle of the nozzle can be easily adjusted. The foot switch can control both electric power and air supply. It is equipped with an ionization indicator light (green) and an
abnormal HV indicator light (red).
The device is equipped with auto ion balance. Within 10V Special alloy discharge needle, more durable than tungsten
ones.
Power Requirements
The main unit of the device is equipped with a small HV power unit. No external HV power unit and HV wiring is needed.
Operation and Use
The IN4000 can be operated in areas where humidity is 20-70% RH (Non-condensing). Excess humidity may affect ionizer performance. The temperature range for the IN4000 is 65-78°F (18-25°C).
Set-up and Placement
Use the IN4000 ionizing air nozzle in immediate proximity to a static sensitive area or object.
Caution
Do not use this ionizer in an explosive environ­ment! Corona ionizers produce a weak plasma that can cause ignition in explosive environ­ments.