Trane Zone Occupancy Brochure

Zone Occupancy Sensor
Figure 1: Zone Occupancy Sensor
The zone occupancy sensor works with applications and zones having intermittent occupancy during the occupied mode. The sensor transmits a signal to a building automation system upon detection of movement in the coverage area. Movement is detected by Passive Infrared (PIR) sensing technology contained within the zone occupancy sensor. Since the sensor must detect movement from an occupant, careful consideration must be taken regarding sensor placement.
The sensor is compatible with Trane VAV and VariTrac provides isolated single-pole, double­throw (SPDT) relay contact outputs to signal the VariTrane The zone occupancy sensor has a multi­cell, multi-tier lens with a maximum field of view of 360°. The maximum coverage area of the sensor is 1200 square feet with a maximum radius of 22 feet from the sensor when mounted at 8 feet above the floor. Please visit a local Trane representative for more information.
Table 1: Sensor Specifications
®
controllers. The sensor
®
or VariTrac ontroller.
trane.com
or contact
Features
Ceiling Mounted PIR Sensing
SPDT Isolated Relay Contacts
0–360° Field of View
1200 square feet Coverage Area and 22
feet Radius
Time Delays of 30 seconds, 10, 20, and 30
minutes
Maximum and Minimum Sensitivity
©2002 American Standard, Inc. All rights reserved
Power Supply 24 VAC or 24 VDC, ± 10%
Maximum VA Load 0.88 VA @ 24 VAC,
0.72 VA @ 24 VDC
Isolated Relay Rating 1 A @ 24 VAC or 24 VDC
Operating Temperature 32 to 131°F (0 to 55°C)
Storage Temperature -22 to 176°F (-30 to 80°C)
Humidity Range 0 to 95% non-condensing
Effective Coverage Area 1200 sq ft
Effective Coverage Radius 22 feet
Housing Material ABS Plastic
Dimensions 3.56" dia. x 1.9" deep
(90.5 mm x 48.2 mm) Protrudes 0.36" (9 mm) from ceiling when mounted.
VAV-SLB006-EN
Placement of the Sensor
Careful considerations must be taken when locating the sensor in a zone. Normally, the approximate coverage with a sensor mounted at a height of 8 feet for an occupant walking is 22 feet radius. For an occupant at a workstation (hand motion) the approximate coverage is 12 feet radius. The effective coverage distance may be slightly less than the maximum sensing distance, depending upon obstacles such as furniture or partitions.
Figure 2: Effective Coverage Area
When the height of the sensor is less than 8 feet, the effective range of the sensor will decrease and the sensitivity to smaller motions will increase. Conversely, when height is greater than eight feet, the effective range of the sensor will increase and the sensitivity to smaller motions will decrease. At heights of more than 12–14 feet, the sensitivity of the sensor will be significantly reduced.
18'
12'
Masking
Masking is a method to eliminate the coverage area for applications not requiring the full field of view of 360°. An insert (mask) is supplied with each sensor and is not needed if full area coverage is desired. Simply cut the mask for the desired coverage area.
Sensor Settings
The sensor is factory-defaulted with a time delay of 30 minutes, a maximum sensitivity and a normal override. By changing the DIP switch settings located on the sensor, the time delay can be configured for 30 seconds, 10 minutes, and 20 minutes, the sensitivity can be set for minimum and the override can be activated in the event of failure. See installation instructions for details.
Figure 3: Dimensional Data
3.56"
(90.5 mm)
(9.1 mm)
1.30"
(33 mm)
0.36"
1.90"
(48.2 mm)
2.76"
(70 mm)
Ø0.1875" (4.8 mm)
(Qty of 2)
Trane An American Standard Company www.trane.com
For more information contact your local district office or e-mail us at comfort @trane.com
©2002 American Standard, Inc. All rights reserved
Literature Order Number VAV-SLB006-EN
File Number SB-TD-VAV-000-SLB006-EN-0602
Supersedes New
Stocking Location La Crosse
Trane has a policy of continuous product and product data improvement and reserves the right to change design and specifications without notice.
Loading...