TDD-D-1
Upflow/Horizontal
Two-stage Condensing
Gas-Fired Furnace
XV 90
TUY060,080,100,120R9V
Variable Speed Blower
Variable Speed Inducer
PUB. NO. 22-1682-05-0802 (EN)
General
Features
NATURAL GAS MODELS
Central heating furnace designs are
certified by the International Approval
Services (IAS) for both natural and
L.P. gas. Limit setting and rating data
were established and approved under
standard rating conditions using
American National Standards Institute
standards.
SAFE OPERATION
The Integrated System Control has solid
state devices, which continuously
monitor for presence of flame, when the
system is in the heating mode of
operation. Dual solenoid combination
gas valve and regulator provide extra
safety.
QUICK HEATING
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure. Low
energy power vent blower, to increase
efficiency and provide a positive
discharge of gas fumes to the outside.
BURNERS
Multi-port In-shot burners will give years
of quiet and efficient service. All models
can be converted to L.P. gas without
changing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational
program provides total control of furnace
limit sensors, blowers, gas valve, flame
control and includes self diagnostics for
ease of service. Also contains
connection points for E.A.C./humidifier.
CONDENSATE DRAIN
Built-in trap which can drain from either
side when the furnace is installed upflow.
AIR DELIVERY
The variable speed, direct drive blower
motor, has sufficient airflow for most
heating and cooling requirements, will
switch from heating to cooling speeds on
demand from room thermostat. The
blower door safety switch will prevent or
terminate furnace operation when the
blower door is removed.
SECONDARY HEAT EXCHANGER
The XV 90 has a special type 29-4C™
stainless steel secondary heat
exchanger to reclaim heat from flue
gases which would normally be lost
outside.
STYLING
Heavy gauge steel and “wrap-around”
cabinet construction is used in the
cabinet with baked-on enamel finish for
strength and beauty. The heat exchanger
section of the cabinet is completely lined
with foil faced fiberglass insulation. This
results in quiet and efficient operation
due to the excellent acoustical and
insulating qualities of fiberglass. Built-in
bottom pan and alternate bottom, left or
right side return air connection in vertical
position.
FEATURES AND
GENERAL OPERATION
The XV 90 High Efficiency Gas Furnaces
employ a Hot Surface Ignition system,
which eliminates the waste of a constant
burning pilot. The integrated system
control lights the main burners upon a
demand for heat from the room
thermostat. Complete front service
access.
a. Low energy power venter.
b. Vent proving differential switch.
© 2002 American Standard Inc. All Rights Reserved
2 Pub. No. 22-1682-05-0802 (EN)
Contents
Feature Summary
Features and Benefits
Standard Equipment
Optional Equipment
General Data
TUY060R9V3V
TUY080R9V3V
TUY100R9V4V
TUY120R9V5V
Performance Data
Electrical Data
Field Wiring
Dimensions
2
4
6
7
11
12
15
3Pub. No. 22-1682-05-0802 (EN)
Features
and Benefits
XV 90 STANDARD EQUIPMENT
• Variable speed indoor blower
• Silicon Nitride Igniter with adaptive
heat up
• Variable speed induced draft blower
• Direct/Non-Direct vent option
• Fused 24 volt control circuit
• Manual reset burner safety switches
• Power supply 115/1/60
• Convertible to horizontal on left side
• 2-stage gas valve
• PVC venting-1 or 2 pipe option
• Accessory hook-up capability
• Integrated solid state control with
self-diagnostics
• Attractive color accents
• Heavy gauge aluminized steel heat
exchanger
• Multi-port In-shot burners
• HInged blower door
• Perfect fit door latches
• Insulated blower door
• Gasketed blower door
• Internal filter rack
• Standard filter sizes
• Two tone color
• Complete front service access
• Left/right gas connection
• Adjustable fan off times
• Cleanable high velocity filters
• Optional L.P conversion kit
• Selectable cooling fan off delay
eliminates need for BAY24X045
time delay kit
• Lifetime limited primary heat
exchanger or secondary heat
exchanger warranty to original
owner (Residential use)
• 5 Year limited parts warranty
4 Pub. No. 22-1682-05-0802 (EN)
Features
and Benefits
OPTIONAL EQUIPMENT
Thermostat, Mechanical 2-Stage Heating/1-Stage Cooling .......................................................................................... TAYSTAT241 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Horizontally) .................................................................................... AY28X092 [ ]
Thermostat, Heating/Cooling Single Stage (Mounts Vertically) .................................................................................... BAYSTAT305 [ ]
Thermostat, Electronic Programmable 2-Stage Heating/2-Stage Cooling .................................................................. TAYSTAT302C [ ]
Thermostat, Electronic Programmable 1-Stage Heating/1-Stage Cooling .................................................................. TAYSTAT300C [ ]
Propane Conversion Kit ......................................................................................................................................... BAYLPKT210A [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (14-1/2" Wide Gas Furnace) ......................................................... TFE145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (17-1/2" Wide Gas Furnace) ......................................................... TFE175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (21" Wide Gas Furnace) ............................................................... TFE210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Super Efficiency (24-1/2" Wide Gas Furnace) ......................................................... TFE245A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (14-1/2" Wide Gas Furnace) .......................................................... TFM145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (17-1/2" Wide Gas Furnace) .......................................................... TFM175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (21" Wide Gas Furnace) ................................................................ TFM210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” High Efficiency (24-1/2" Wide Gas Furnace) .......................................................... TFM245A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (14-1/2" Wide Gas Furnace) ..................................................... TFP145A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (17-1/2" Wide Gas Furnace) ..................................................... TFP175A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (21" Wide Gas Furnace) .......................................................... TFP210A9FR0 [ ]
Electronic Air Filter, “Perfect Fit” Standard Efficiency (24-1/2" Wide Gas Furnace) ..................................................... TFP245A9FR0 [ ]
Coil Enclosure (14-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1400C [ ]
Coil Enclosure (17-1/2" Wide Cabinets) .................................................................................................................. BAYCLE1700C [ ]
Coil Enclosure (21" Wide Cabinets) ........................................................................................................................ BAYCLE2100C [ ]
Coil Enclosure (24-1/2" Wide Cabinets) .................................................................................................................. BAYCLE2400C [ ]
Side Filter Rack ........................................................................................................................................................ BAYFLTR200 [ ]
Filter Kit/Horizontal Conversion TUY060, 080-R ......................................................................................................... BAYFLTR203 [ ]
Filter Kit/Horizontal Conversion TUY100-R ................................................................................................................ BAYFLTR204 [ ]
Filter Kit/Horizontal Conversion TUY120-R ................................................................................................................ BAYFLTR205 [ ]
Filter Accessory Kit Upflow 14.5" Furnaces ............................................................................................................... BAYFLTR317 [ ]
Filter Accessory Kit Upflow 21" Furnaces .................................................................................................................. BAYFLTR321 [ ]
Filter Accessory Kit Upflow 24.5" Furnaces ............................................................................................................... BAYFLTR324 [ ]
High Altitude Switch TUY060R .............................................................................................................................. BAYHALT2451 []
High Altitude Switch TUY080, 100R ...................................................................................................................... BAYHALT2461 []
High Altitude Switch TUY120R .............................................................................................................................. BAYHALT2471 []
Concentric Vent Kit ............................................................................................................................................... BAYVENT100A [ ]
Sidewall Vent Termination Kit ................................................................................................................................. BAYVENT200B [ ]
Manufactured/Mobile Home Kit ............................................................................................................................. BAYMFGH100A [ ]
1 Optional kit allows 200 ft. max. vent length from 5,000-12,000 feet above sea level. See installer's guide.
5Pub. No. 22-1682-05-0802 (EN)