Trane TTD 524 AB0E, TTD 518 AB0E, TTD 521 AB0E, TTD 524 AB00, TTT 521 AB0E Installation Manual

...
Installation Manual
Multi-Split System Condensing Unit 18,000-36,000 Btuh Models 50/60 Hz
MS-SVN005-EN
TTD/TTT
60 Hz Models Cooling Only
TTD 518 A10E TTD 521 A10E TTD 524 A10E TTD 524 A100 TTT 527 A10E TTT 530 A10E TTT 533 A10E
50 Hz Models Cooling Only
TTD 518 AB0E TTD 521 AB0E TTD 524 AB0E TTD 524 AB00 TTT 521 AB0E TTT 527 AB0E TTT 530 AB0E TTT 533 AB0E
TTD 536 AB0E TTD 536 AB00 TTT 536 AB0E TTT 536 AB00 TTD 536 DB00 TTD 536 DB0E TTT 536 DB0E
TTD 536 A10E TTD 536 A100 TTT 536 A10E TTT 536 A100 TTD 536 D100 TTD 536 D10E TTT 536 D10E
2
MS-SVN005-EN
General Information
© American Standard Inc. 2000
General Information
This Installation Manual is given as a guide to good practice in the installation by the installer of TTD/TTT mini-split system. Installation procedures should be performed in the sequence that they appear in this manual.
For installing the unit to operate properly and reliably, it must be installed in accordance with these instructions. Also, the services of a qualified service technician should be employed, through the maintenance contract with a reputable service company.
Read this Installation Manual completely before installing and operating the system.
About this Manual
Cautions appear at appropriate places in this Instruction Manual. Your personal safety and the proper operation of this machine require that you follow them carefully. The Trane Company assumes no liability for installations or servicing performed by unqualified personnel. All phases of the installation of this air conditioning system must conform to all national, provincial, state and local codes.
About the Unit
These TTD/TTT units are assembled, pressure tested, dehydrated, charged and run tested before shipment.
Reception
On arrival, inspect the unit before signing the delivery note. Specify any damage of the unit on the delivery note, and send a registered letter of protest to the last carrier of the goods within 72 hours of delivery. Notify the dealer at the same time.
The unit should be totally inspected within 7 days of delivery. If any concealed damage is discovered, send a registered letter of protest to the carrier within 7 days of delivery and notify the dealer.
Warning
Warnings are provided at appropriate places in this manual to indicate to installers, operators and service personnel of potentially hazardous situations which, if not avoided, COULD result in death or serious injury.
Caution
Cautions are provided at appropriate places in this manual to indicate to installers, operators, and service personnel of potentially hazardous situations which, if not avoided, MAY result in minor or moderate injury or malfunction of the unit.
Your personal safety and the proper operation of this unit require that you follow them carefully. The Trane Company assumes no liability for installations or servicing performed by unqualified personnel.
Warranty
Warranty is based on the general terms and conditions by country. The warranty is void if the equipment is modified or repaired without the written approval of The Trane Company, if the operating limits are exceeded or if the control system or the electrical wiring is modified.
Damage due to inappropriate installation, lack of knowledge or failure to comply with the manufacturer’s instructions, is not covered by the warranty obligation. If the installation does not conform to the rules described in Installation Manual, it may entail cancellation of warranty and liabilities by The Trane Company.
Important
This document is customer property and is to remain with unit. Please place in service information pack upon completion of work. These instructions do not cover all variations in systems, nor do they provide for every possible contingency to be met in connection with installation. Should further information be desired or should particular problems arise which are not covered sufficiently in this manual, the matter should be referred to your authorized Trane dealer.
MS-SVN005-EN
3
Contents
General Information 2
Valid System Combinations 4
Installation Requirements 6
Location and Preparation of Units 7
Connection of Refrigerant Tubing 8
Condensate Drain Piping 9
System Evacuation and Purging 10
Electrical Installation 11
Wiring Diagram 12
Dimensional Data 17
4
MS-SVN005-EN
Valid System Combinations
Table 1 : TTT/TTD Multi-Split Condensing Unit with Convertible,
Concealed and Frio Hi-Wall (For Domestic Only) Indoor Unit
Model Model Nominal 50 Hz 60 Hz
Outdoor Unit Indoor Unit Capacity
Btuh
MCW509H 9,000 Yes Yes MCW509H 9,000
MCW509H 9,000 Yes Yes MCW512H 12,000
MCW512H 12,000 Yes Yes MCW512H 12,000
MCX512 or MCD512 12,000 Yes Yes MCX512 or MCD512 12,000
MCW509H 7,500 Yes No
TTT521AB0E MCW509H 7,500
MCW509H 7,500
MCW509H 9,000 Yes Yes
TTT527AB0E/A10E MCW509H 9,000
MCW509H 9,000
MCW509H 9,000 Yes Yes
TTT530AB0E/A10E MCW509H 9,000
MCW512H 12,000
MCW509H 9,000 Yes Yes
TTT533AB0E/A10E MCW512H 12,000
MCW512H 12,000
MCW518H 18,000 Yes Yes MCW518H 18,000
MCX518 or MCD518 18,000 Yes Yes MCX518 or MCD518 18,000
MCW512H 12,000 Yes Yes
TTT536AB0E/A10E MCW512H 12,000
MCW512H 12,000
MCX512 or MCD512 12,000 Yes Yes
TTT536AB00/A100 MCX512 or MCD512 12,000
MCX512 or MCD512 12,000
MCX512 or MCD512 12,000 Yes Yes MCX524 or MCD524 24,000
MCW512H 12,000 Yes Yes MCW524H 24,000
MCW509H 9,000 Yes Yes
TTT536DB0E/D10E MCW509H 9,000
MCW518H 18,000
TTD518AB0E/A10E
TTD521AB0E/A10E
TTD524AB0E/A10E
TTD524AB00/A100
TTD536AB0E/A10E
TTD536AB00/A100
TTD536DB00/D100
TTD536DB0E/D10E
MS-SVN005-EN
5
Table 1.1 : TTT/TTD Multi-Split Condensing Unit with
Contura 3G Hi-Wall Indoor Unit
Model Model Nominal 50 Hz 60 Hz
Outdoor Unit Indoor Unit Capacity
Btuh
MCW509K 8,600 Yes Yes MCW509K 8,600
MCW509K 8,600 Yes Yes MCW512K 11,000
MCW512K 11,000 Yes Yes MCW512K 11,000
MCW507K 7,000 Yes No
TTT521AB0E MCW507K 7,000
MCW507K 7,000
MCW509K 8,600 Yes Yes
TTT527AB0E/A10E MCW509K 8,600
MCW509K 8,600
MCW509K 8,600 Yes Yes
TTT530AB0E/A10E MCW509K 8,600
MCW512K 11,000
MCW509K 8,600 Yes Yes
TTT533AB0E/A10E MCW512K 11,000
MCW512K 11,000
MCW518K 17,000 Yes Yes MCW518K 17,000
MCW512K 11,000 Yes Yes
TTT536AB0E/A10E MCW512K 11,000
MCW512K 11,000
MCW512K 11,000 Yes Yes MCW524K 21,000
MCW512K 11,000 Yes Yes MCW526K 24,000
MCW509K 8,600 Yes Yes
TTT536DB0E/D10E MCW509K 8,600
MCW518K 17,000
TTD518AB0E/A10E
TTD524AB0E/A10E
TTD521AB0E/A10E
TTD536DB0E/D10E
TTD536AB0E/A10E
6
MS-SVN005-EN
Indoor Unit 507 509 512 518 524/526
Item O.D. O.D. O.D. O.D. O.D.
mm (in) mm (in) mm (in) mm (in) mm (in)
Deoxidized Annealed (L*) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 9.52 (3/8)
Copper Tube (S*) 9.52 (3/8) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2) 15.88 (5/8)
Installation Requirements
Table 2 : For Convertible (MCX), Concealed (MCD) and Hi-Wall (MCW, Frio) Indoor units
1. Copper Tubing
Copper tubing, fittings and insulation to interconnect the suction (S) (wide tube) and liquid (L) (narrow tube) refrigerant lines between the indoor and outdoor units can be purchased locally. It is necessary to purchase the following items:
- Purchase equal lengths of both tubes and insulation required. Cut the appropriate tube lengths, 30 to 40 cm (12 to 16 in.) longer on each one to deepen vibration between units. Wall thickness of copper tube should be 0.8 mm (0.0314 in.). Both tubes must be well insulated with proper insulation materials.
- The length of wiring will determine the wire size. See local codes, refer to section of electrical installation.
2. Additional Materials
- Saddles or clamps to hold refrigerant tubing.
- Insulated clamps or staples for connecting wire. See local codes.
- Refrigeration oil and tape (armored).
- Putty or similar filter.
*On Cooling Mode
Indoor Unit 509 512 518 524
Item O.D. O.D. O.D. O.D.
mm (in) mm (in) mm (in) mm (in)
Deoxidized Annealed (L*) 6.35 (1/4) 6.35 (1/4) 6.35 (1/4) 9.52 (3/8)
Copper Tube (S*) 9.52 (3/8) 12.7 (1/2) 12.7 (1/2) 15.88 (5/8)
Foamed Polyethylene Diameter : According to O.D. of copper tube
Insulation Thickness : No less than 8 mm (0.3 in)
Insulated Copper Wire Length required to make electrical wiring
Table 3 : For Hi-Wall (MCW, Contura 3G) Indoor units
*On Cooling Mode