Central Heating furnace designs are
certified by the American Gas Association for both natural and L.P. gas. Limit
setting and rating data were established
and approved under standard rating
conditions using American National
Standards Institute standards.
SAFE OPERATION
The Integrated System Control has
solid state devices, which continuously
monitor for presence of flame, when the
system is in the heating mode of operation. Dual solenoid combination gas
valve and regulator provide extra safety.
QUICK HEATING
Durable, cycle tested, heavy gauge
aluminized steel heat exchanger
quickly transfers heat to provide warm
conditioned air to the structure. Low energy power vent blower, to increase
efficiency and provide a positive discharge of gas fumes to the outside.
BURNERS
Multiport Inshot burners will give years
of quiet and efficient service. All models
can be converted to L.P. gas without
changing burners.
INTEGRATED SYSTEM CONTROL
Exclusively designed operational program provides total control of furnace
limit sensors, blowers, gas valve, flame
control and includes self diagnostics for
ease of service. Also contains connection points for E.A.C./humidifier.
AIR DELIVERY
The variable speed, direct drive blower
motor, has sufficient airflow for most
heating and cooling requirements, will
switch from heating to cooling speeds
on demand from room thermostat. The
blower door safety switch will prevent or
terminate furnace operation when the
blower door is removed.
STYLING
Heavy gauge steel and “wrap-around”
cabinet construction is used in the
cabinet with baked-on enamel finish for
strength and beauty. The heat exchanger section of the cabinet is completely
lined with foil faced fiberglass insulation.
This results in quiet and efficient operation due to the excellent acoustical and
insulating qualities of fiberglass. Built-in
bottom pan and alternate bottom, left or
right side return air connection provision.
FEATURES AND
GENERAL OPERATION
The XV 80 High Efficiency Gas Furnaces employ a Hot Surface Ignition
system, which eliminates the waste of
a constant burning pilot. The integrated
system control lights the main burners
upon a demand for heat from the room
thermostat. Complete front service
access.
a. Low energy power venter
b. Vent proving pressure switch.
Ampacity (In Amps)
Max Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by ETL.
2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
Ampacity (In Amps)
Max Overcurrent Protection (Amps)
PIPE CONN. SIZE (IN.)
DIMENSIONS
Crated (In.)
WEIGHT
Shipping (Lbs.) / Net (Lbs)
1 Central Furnace heating designs are certified by ETL.
2 Ratings shown are for elevations up to 2000 feet. For elevations above 2000 feet; Ratings should be reduced at the rate of 4% for each 1000 feet above sea level.
3 Based on U.S. government standard tests.
4 The above wiring specifications are in accordance with National Electrical Code; however, installations must comply with local codes.
*DC1C100A9481A
Downflow / Horizontal
100,000
93,000
92.1
35 - 65
DIRECT
11 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
2 - 16x20 - 1in.
2 Round
Aluminized Steel - Type I
20
5 — 45
5 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
5
115/1/60
13.6
20
1/2
H x W x D
41-3/4 x 23 x 30-1/2
185 / 175
*DC1D120A9601A
Downflow / Horizontal
120,000
112,000
92.1
40 - 70
DIRECT
11 x 10
1
4
See Fan Performance Table
1/2
1075
115/1/60
Centrifugal
Direct - 1
1/20 - 3450
115/1/60
0.71
No
High Velocity
2 - 16x20 - 1in.
3 Round
Aluminized Steel - Type I
20
6 — 45
6 — 56
Redundant - Single Stage
Hot Surface Ignition
Multiport Inshot
6
115/1/60
12.9
20
1/2
H x W x D
41-3/4 x 26-1/2 x 30-1/2
206 / 196
Pub. No. 22-1670-10
7
Page 8
Performance
Data
FURNACE AIRFLOW (CFM) VS. EXTERNAL STATIC PRESSURE (in. w.c.)