Upflow / Horizontal & Downflow / Horizontal,
Gas-Fired, Direct Vent, 2-Stage Condensing
Furnaces with Variable Speed Inducer
*UX2B060A9362A *UX2B080A9422A *UX2C100A9482A
*UX2D120A9602A *DX2B060A9362A *DX2B080A9422A
*DX2C100A9482A *DX2D120A9602A
*__Firstlettermay be"A" or "T"
ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES
IMPORTANT -- This Document is customer property and is to remain with this unit.
Please return to service information pack upon completion of work.
*UX2 *DX2
DOWNFLOW
A!R
A/R
FLOW
UPFLOW
AIR
FLOW
UPFLOW/HORIZONTAL LEFT
DOWNFLOW/HORIZONTAL RIGHT
/
\
/ _
FLOW
FLOW
\
i °
A341624P03

Installer's Guide
SAFETY SECTION
The following safety practices and precautions must be
followed during the installation, servicing, and operation of
this furnace.
1. Use only with the type of gas approved for this furnace.
Refer to the furnace rating plate.
2. Install this furnace only in a location and position as
specified in "Location and Clearances" (page 3), of these
instructions.
3. Provide adequate combustion and ventilation air to the
furnace space as specified in "Air for Combustion and
Ventilation" (pages 7-8), of these instructions.
4. Combustion products must be discharged outdoors.
Connect this furnace to an approved vent system only, as
specified in the "Venting" section (pages 13-23), of these
instructions.
5. Never test for gas leaks with an open flame. Use a
commercially available soap solution made specifically
for the detection of leaks to check all connections, as
specified in "Gas Piping" (page 31), of these instructions.
6. Always install the furnace to operate within the furnace's
intended temperature-rise range with a duct system
which has an external static pressure within the allow-
able range, as specified on the unit rating plate. Airflow
with temperature rise for cfm versus static is shown in
the Service Facts accompanying this furnace.
7. When a furnace is installed so that supply ducts carry air
circulated by the furnace to areas outside the space
containing the furnace, the return air shall also be
handled by a duct(s) sealed to the furnace casing and
terminating outside the space containing the furnace.
8. A gas-fired furnace for installation in a residential
garage must be installed as specified in "Location and
Clearances" section (page 3), of these instructions.
9. The furnace may be used for temporary heating of
buildings or structures under construction only when the
following conditions have been met:
a. The furnace venting system must be complete and
installed per manufacturer's instructions.
b. The furnace is controlled only by a room thermostat
(no field jumpers).
c. The furnace return air duct must be complete and
sealed to the furnace and clean air filters are in place.
d. The furnace input rate and temperature rise must be
verified to be within nameplate marking.
e. 100% of the furnace combustion air requirement must
come from outside the structure.
f. The furnace return air temperature range is between
55 and 80 degrees Fahrenheit.
g. Clean the furnace, duct work, and components upon
substantial completion of the construction process,
and verify furnace operating conditions including
ignition, input rate, temperature rise and venting,
according to the manufacturer's instructions.
10. This product must be gas piped by a Licensed Plumber or
Gas Fitter in the Commonwealth of Massachusetts.
CARBON MONOXIDE POISONING HAZARD
Failure to follow the steps outlined below for each
appliance connected to the venting system being
placed into operation could result in carbon monoxide
poisoning or death.
The following steps shall be followed for each appliance
connected to the venting system being placed into
operation, while all other appliances connected to the
venting system are not in operation:
1. Seal any unused openings in the venting system.
2.
Inspect the venting system for proper size and
horizontal pitch, as required in the National Fuel Gas
Code, ANSI Z223.1/NFPA 54 or the CAN/CGA B149
Installation Codes and these instructions. Determine
that there is no blockage or restriction, leakage,
corrosion and other deficiencies which could cause an
unsafe condition.
3.
As far as practical, close all building doors and
windows and all doors between the space in which the
appliance(s) connected to the venting system are
located and other deficiencies which could cause an
unsafe condition.
4. Close fireplace dampers.
5.
Turn on clothes dryers and any appliance not
connected to the venting system. Turn on any exhaust
fans, such as range hoods and bathroom exhausts, so
they are operating at maximum speed. Do not operate
a summer exhaust fan.
6. Follow the lighting instructions. Place the appliance
being inspected into operation. Adjust the thermostat
so appliance is operating continuously.
7.
If improper venting is observed during any of the above
tests, the venting system must be corrected in
accordance with the National Fuel Gas Code,
ANSI Z221.1/NFPA 54 and/or CAN/CGA B149
Installation Codes.
8.
After it has been determined that each appliance
connected to the venting system properly vents where
tested as outlined above, return doors, windows,
exhaust fans, fireplace dampers and any other gas-fired
burning appliance to their previous conditions of use.
Safety signal words are used to designate a degree or level
of seriousness associated with a particular hazard. The
signal words for safety markings are DANGER, WARNING,
and CAUTION.
a. DANGER indicates an imminently hazardous situation
which, if not avoided, will result in death or serious injury.
This signal word is limited to the most extreme situations.
b. WARNING indicates a potentially hazardous situation
which, if not avoided, could result in death or serious injury.
c. CAUTION indicates a potentially hazardous situation
which, if not avoided, may result in minor or moderate
To prevent shortening its service life, the furnace should
not be used as a "Construction Heater" during the finishing
phases of construction until the requirements listed in item
9, a-g of the safety section of this publication have been
met. Condensate in the presence of chlorides and fluo-
rides from paint, varnish, stains, adhesives, cleaning
compounds, and cement create a corrosive condition which
may cause rapid deterioration of the heat exchanger.
© 2008 Trane All Rights Reserved 18-CD1 9D8-1 5
FIRE OR EXPLOSION HAZARD
Failure to follow the safety warnings exactly could result in
serious injury, death or property damage.
Improper servicing could result in dangerous operation,
serious injury, death, or property damage.

Installer's Guide
GENERAL
The manufacturer assumes no responsibility for equipment
installed in violation of any code or regulation.
It is recommended that Manual J of the Air Conditioning
Contractors Association (ACCA) or A.R.I. 230 be followed in
estimating heating requirements. When estimating heating
requirements for installation at Altitudes above 2000 ft.,
remember the gas input must be reduced (See GAS INPUT
ADJUSTMENT).
Material in this shipment has been inspected at the
factory and released to the transportation agency
without known damage. Inspect exterior of carton for
evidence of rough handling in shipment. Unpack
carefully after moving equipment to approximate
location. If damage to contents is found, report the
damage immediately to the delivering agency.
Codes and local utility requirements governing the installa-
tion of gas fired equipment, wiring, plumbing, and flue
connections must be adhered to. In the absence of local codes,
the installation must conform with latest edition of the
National Fuel Gas Code ANSI Z223.1 • National Installation
Code, CAN/CGA B149.1. The latest code may be obtained
from the American Gas Association Laboratories, 400 N.
Capitol St. NW, Washington D.C. 20001. 1-800-699-9277 or
www.aga.org
These furnaces have been classified as CATEGORY IV
furnaces in accordance with latest edition of ANSI Z21.47
standards ° CAN/CGA 2.3. Category IV furnaces operate
with positive vent static pressure and with a flue loss less
than 17 percent. These conditions require special venting
systems, which must be gas tight and water tight. These
Category IV Direct Vent furnaces are approved for installa-
tion in Manufactured/Mobile housing when used with
BAYMFGH001A.
LOCATION AND CLEARANCES
The location of the furnace is normally selected by the
architect, the builder, or the installer. However, before the
furnace is moved into place, be sure to consider the following
requirements:
1. Is the location selected as near the chimney or vent and
as centralized for heat distribution as practical?
2. Do all clearances between the furnace and enclosure
equal or exceed the minimums stated in Clearance Table
on the Outline Drawings.
3. Is there sufficient space for servicing the furnace and
other equipment? A minimum of 24 inches front accessi-
bility to the furnace must be provided. Any access door
or panel must permit removal of the largest component.
4. Are there at least 3 inches of clearance between the
furnace combustion air openings in the front panel and
any closed panel or door provided?
5. Are the ventilation and combustion air openings large
enough and will they remain unobstructed? If outside
air is used, are the openings set above the highest snow
accumulation level? (See the Air for Combustion and
Ventilation section.)
6. Allow sufficient height in supply plenum above the
furnace to provide for cooling coil installation, if the
cooling coil is not installed at the time of this furnace
installation.
7. A furnace shall be installed so electrical components are
protected from water.
8. If the furnace is installed in a residential garage, it
must be installed so that the burners, and the ignition
18-CD19D8-15 3
Contents
Installation Instructions
General
Location and Clearances
Outline Drawings
Upflow Installation
Downflow Installations
Air For Combustion and Ventilation
Duct Connections
Return Air Filters
General Venting
Venting Materials
Vent Tables
Horizontal Venting Through Wall
Venting Through the Roof
Venting Routed Through a Masonry Chimney
Downward Venting
Condensate Drain Instructions
Field Wiring Diagrams
Electrical Connections
Gas Piping
Combustion and Input Check
High Altitude Derate
Start-up and Adjustment
Preliminary Inspections
Lighting Instructions
Sequence of Operation
Control and Safety Switch Adjustments
Abnormal Conditions
IFC Error Flash Codes
Fault Code Recovery
source are located not less than 18 inches above the floor
and the furnace must be located or protected to avoid
physical damage from vehicles.
IMPORTANT:
The furnace must be installed level The only allowable variation
would be slightly to the left and/or forward in upflow installations
or slightly toward the front in horizontal installations. This is
necessary for proper condensate drainage.
Do not install the furnace in a corrosive or contaminated
atmosphere. Failure to follow this warning could result in
early equipment failure.
Do not install the furnace directly on carpeting, tile or other
combustible material other than wood flooring. For vertical
downflow application, subbase (BAYBASE205) must be
used between the furnace and combustible flooring. When
the downflow furnace is installed vertically with a cased
coil, a subbase is not required.

4_
Oo
6
ED
ED
oo
i
ol
ii
l
DIM"C"
5/8" J
-,-- 5/8" 4- I/ilJ
OUTLET t°_
AIR /._
OUTSIDEAIR
7/8" HOLE_
ELECTRICALLY.... _ ,
SUPPLY ,_._ .... _1
1/78" x 7/8"_
SLOT KNOCKOUT
CONDENSATE DRAIN
(HORIZONTAL)
I-I/8" KNOCKOUT-
CONDENSATE DRAIN
I-5/16"--=-
,l-m..
01_0
23-3/4"
-i
DIM "D"
_1
3/4,,_-
3/4" --_
--,_ 28- I /2" -_,.
INLET I • I
AIR "
I_ 24- I/32" _-J L 3-7/32"
DIM "B"
_---r_2"FLUE CONNECT
SEE NOTES I & 2
"E"
"'--4-1/16"
*UX2 UPFLOW / HORIZONTAL OUTLINE DRAWING
(ALL DIMENSIONS ARE IN INCHES)
',1-3-15/16"
"--2-1/16"
-¢1-1/2" GAS
SUPPLY
"-2-1/8"
__T
I -7/8 22-
--__20-1/4"
5 "
18-
2 ii
[
;0-5/8"
/4" I
IZONTAL APPLICATION
IS SIDE ONLY)
I/2"_
40"
o
DIM "A" ---,'-
-,- I/2"
Model
DIM "A" DIM "B" DIM "C" DIM "D" DIM "E" DIM "F"
(See Note 1 & 2)
*UX2B060A9362A
17-1/2" 2-1/4" 16-1/4" 16" 7-1/2" 2"
*UX2B080A9422A
*UX2C100A9482A 21" 2-1/2" 19-3/4" 19-1/2" 9" 3"
*UX2D120A9602A 24-1/2" 2-15/16" 23-1/4" 23" 10" 3"
* Prefix May Be "A" or "T" Notes:
1. *UX2D120A9602A Requires 3" Diameter Vent Pipe.
*UX2C100A9482A Requires 2-1/2" or 3" Diameter Vent Pipe.
2. Diameter of Vent Pipe may be limited to 2-1/2" or 3" on some
models at different altitudes. Refer to the Vent Length Table for
proper application.
7/8" KNOCKOUT
ELECTRICAL
SUPPLY
(ALTERNATE)
-_1-1/2" KNOCKOUT
GAS SUPPLY
(ALTERNATE)
I/8" KNOCKOUT
DRAIN
(ALTERNATE)
MINIMUMCLEARANCETO
COMBUSTIBLE MATERIALS
SIDES O IN.
REAR 0 IN.
FRONT 3 IN,
TOP I IN.
FLUE 0 IN.
HORIZONTAL(FLUE
BSCHARGEON THE LEFTI
ALCOVE
SIDES
RIGHT O IN
LEFT O IN
REAR 6 IN
FRONT 18 IN
TOP I IN,
FLUE 0 IN,
CLOSET
SIDES
RIGHT I IN
LEFT I IN
REAR 3 IN
FRONT 3 IN
TOP I IN
FLUE 0 IN,
From Dwg. 21C341884 Rev. 1
|
3
ltl
Ill
I
I
II
II
Ill
n_
iI

oo
i
©
0
qo
0
oo
i
t_n
....... 19 5'8 .......
......._2" F u
, CON'\ECT
SEE IOTE J
DIM "D"
!
A
3/4
o_ a,,6,_.... j i 7 _,,4"
*DX2 DOWNFLOW / HORIZONTAL OUTLINE DRAWING
(ALL DIMENSIONS ARE IN INCHES)
From Dwg. 21C341885 Rev. 1
,; llOlR z.N '. t,,_l C,\I ON
',, IS _i i . I
,,
2-i ,'8 ........."-
' 0 "
!
DIM "A" ,.-.-
23/i6"
Model
DIM "A" DIM "B" DIM "C" DIM "D"
(See Note 1)
*DX2BO60A9362A
17-1/2" 2-1/4" 16-1/4" 16"
*DX2BO80A9422A
*DX2C100A9482A 21" 2-1/2" 19-3/4" 19-1/2"
*DX2D120A9602A 24-1/2" 2-15/16" 23-1/4" 23"
Prefix May Be "A" or "T" Notes:
1. Diameter of Vent Pipe may be limited
to 2-1/2" or 3" on some models at
different altitudes. Refer to the Vent
Length Table for proper application.
/ _,S,'8' L C R CAL
/ (ONNIC ON AI Ei!'NA I
/
/
/ / ,_'S'/6' i( IRICA
/ CONN ?liON ,*,L ERNAIE)
/ NOC Oi
kc,,,INE_T k.
i ?5"
0 /z"
i
"--- ¢ ......s
,,,Jr ,E DA
--w u T
If ,,,,J v ,
MINIMUM CLEARANCE TO
COMBUSTIBLE MATERIALS
DOWNFLOW
SIDES 0
REAR 0
I ROi' I 3 ',
O[ N
i I b E 0 N
HORIZONTAL (FLUE
DISCHARGE ON THE LEFT)
ALCOVE
SIDES
RI iT 0 \
REAR 6 _N
iRON[ 18 N
-OR N
FlU 0 \
CLOSET
SIDES
[EFT ;N
REAR _N
FRONT _N
lOP iN
FI U_ i N
|
Itl
Iit
m
m
I1
II
ml
I1

Installer's Guide
UPFLOW INSTALLATION
Standoffs and screws (See Figure 1) are included with the
cased coils for attachment to the furnace. There are clear-
ance alignment holes near the bottom of the coil wrapper.
Drill screws are used to engage the furnace top flanges. The
standoff is inserted into the cabinet alignment hole. The drill
screws are inserted through the standoffs then screwed into
the furnace flange. The coil is always placed downstream of
the furnace airflow.
STANDOFFS (4) DRILL SCREWS (4)
J
FOR VERTICAL
- SCREWS
(BOTH BIDES)
STANDOFFS
(BOTH SIDES)
DOWNFLOW INSTALLATIONS
(_ CABINET SIDE CABINET SIDE
SUB-BASE SUB-BASE
FLANGE FLANGE
(BENT UP) (BENT UP)
DUCT
Do not install the furnace directly on carpeting, tile or other
combustible material other than wood flooring. For
vertical downflow application, subbase (BAYBASE205)
must be used between the furnace and combustible
flooring. When the downflow furnace is installed vertically
with a cased coil, a subbase is not required.
Required floor opening: (DOWNFLOW)
See Figure 3 and Table I
TABLE 1
CABINET RETURN FLOOROPENING PLENUM OPENING
WIDTH DUCT WIDTH "A.... B.... C.... D"
14-1/2" 13-1/4" 13-5/8" 20-1/8" 12-5/8" 19-3/8"
17-1/2" 16-1/4" 16-5/8" 20-1/8" 15-5/8" 19-3/8"
21" 19-3/4" 20-1/8" 20-1/8" 19-1/8" 19-3/8"
24-1/2" 23-1/4" 23-5/8" 20-1/8" 22-5/8" 19-3/8"
HORIZONTAL INSTALLATION
The coil and furnace must be fully supported when used in
the horizontal position. It is always recommended that an
auxiliary drain pan be installed under a horizontally in-
stalled evaporator coil or 90% gas furnace. Connect the
auxiliary drain line to a separate drain line (no trap is
needed in this line).
Three brackets (with screws) are included with downflow
furnaces for installation to stabilize and secure the furnace
and TXC cased coil in the horizontal position. See Fig-
ure 4.
©
CASED COIL CONNECTION
BRACKET FOR DOWNFLOW
FURNACE IN HORIZONTAL
DOWNFLOW ONLY
IMPORTANT:
The 2/4TXC cased coil must be placed downstream of the
furnace. In horizontal installations, the apex of the coil
may point either toward or away from the furnace. See
the 2/4TXC coil Installer's Guide for more details.
The cased coil is secured to the furnace and both the furnace
and the cased coil must be properly supported. The brackets
mount using the rear screws on the coil case and use the
screws provided to secure the bracket to the furnace. The
remaining bracket is placed as close to center as possible
(horizontally) between the coil case front and the furnace
bottom channel (for downflow/horizontal furnace). Use four of
the screws provided to secure the bracket. The upflow furnace,
converted to horizontal, aligns and attaches the TXC coil as in
Figure 1. However, the coil requires additional support.
The furnace may be installed in an attic or crawl space in the
horizontal position by placing the furnace on the left side (as
viewed from the front in the vertical position). The horizontal
furnace installation in an attic should be on a service plat-
form large enough to allow for proper clearances on all sides
and service access to the front of the furnace (See Figure 5 &
Clearance Tables, pages 4-5). Line contact is only permis-
sible between lines formed by intersections of the top and two
sides of the furnace casing and building joists, studs, or
framing.
The furnace may be placed horizontally in a crawl space on a
pad or other noncombustible material which will raise the
unit for sufficient protection from moisture.
@
UPFLOW/ I
HORIZONTAL I
SHOWN WITH
DIRECT VENT
18-CD19D8-15

Installer's Guide
®
[--
50 CU. FT. OR MORE
UNCONFINED
The furnace must be supported at both ends and the
middle when installed horizontally. The furnace must
also be elevated approximately 4-6 inches to allow
clearance for the condensate drain to exit the cabinet in
the horizontal position.
The horizontal furnace may also be suspended from the joists
using 3/8" all-thread rods with pieces of angle iron under-
neath the furnace to form a hanging rack at both ends and
the midpoint. The rods need to be of sufficient length to
allow for proper clearances from combustible materials. The
angle iron needs to be at least 32" in length to allow for
access to service panels.
AIR FOR COMBUSTION AND VENTILATION
If these furnaces are installed in a nondirect vent capacity
then the adequate flow of combustion and ventilating air
must not be obstructed from reaching the furnace. Air
openings provided for combustion air must be kept free of
obstructions which restrict the flow of air. Airflow restric-
tions affect the efficiency and safe operation of the furnace.
Keep this in mind should you choose to remodel or change
the area which contains your furnace. Furnaces must have a
free flow of air for proper performance.
Provisions for combustion and ventilation air shall be made
in accordance with latest edition of Section 5.3, Air for
Combustion and Ventilation, of the National Fuel Gas Code,
ANSI Z223.1 -- CAN/CGA B 149.1 or applicable provisions of
the local building codes. Special conditions created by
mechanical exhausting of air and fireplaces must be con-
sidered to avoid unsatisfactory furnace operation.
OUTSIDE AIR IS RECOMMENDED
The use of indoor air for most applications is acceptable,
unless there is the presence of corrosive chemicals or
contamination. Certain types of installation will require
the use of outside air for combustion.
The following types of installations will require use of
OUTDOOR AIR for combustion, due to chemical exposures:
* Commercial buildings
* Buildings with indoor pools
* Furnaces installed in "confined" laundry rooms
* Furnaces installed in "confined" hobby or craft rooms
* Furnaces installed near chemical storage areas.
Exposure to the following substances in the combustion air
supply will also require OUTDOOR AIR for combustion:
* Permanent wave solutions
* Chlorinated waxes and cleaners
* Chlorine based swimming pool chemicals
* Water softening chemicals
* Deicing salts or chemicals
* Carbon Tetrachloride
* Halogen type refrigerants
* Cleaning solvents (such as perchloroethylene)
* Printing inks, paint removers, varnish, etc.
* Hydrochloric acid
* Cements and glues
* Antistatic fabric softeners for clothes dryers
* Masonry acid washing materials
18-CD19D8-15 7
.....\ /
Furnace locations may be in a "confined space" or an
"unconfined space".
Unconfined space is defined in Figure 6. These spaces may
have adequate air by infiltration to provide air for combustion
and ventilation. Buildings with tight construction (for
example, weather stripping, heavily insulated, caulked, vapor
barrier, etc.), may need additional air to be provided as
described for confined space.
Confined spaces are installations with less than 50 cu. ft. of
space per 1000 BTU/hr input from all equipment installed.
Air for combustion and ventilation requirements can be
supplied from inside the building as in Figure 9 or from the
outdoors, as in Figure 10.
Q MINIMUM AREA IN SQUARE FEET
FOR UNCONFINED SPACE INSTALLATIONS
FURNACE WITH 8 FT. CEILING
MAXIMUM BTUH MINIMUM AREA IN SQUARE FEET
INPUT RATING OF UNCONFINED SPACE
60,000 375
80,000 500
100,000 625
120,000 875
® -I
m
m FURNAOF
CONFINED
SPACE
1.
All air from inside the building as in Figure 9: The
confined space shall be provided with two permanent
openings communicating directly with an additional
room(s) of sufficient volume so that the combined volume
of all spaces meets the criteria for an unconfined space.
The total input of all gas utilization equipment installed
in the combined space shall be considered in making this
determination. Refer to Table 2 for minimum open areas
requirements.
2.
All air from outdoors as in Figure 10: The confined space
shall be provided with two permanent openings, one
commencing within 12 inches of the top and one com-
mencing within 12 inches of the bottom of the enclosure.
The openings shall communicate directly, or by ducts,
with the outdoors or spaces (crawl or attic) that freely
communicate with the outdoors. Refer to Table 2, for
minimum open areas requirements.
MINIMUM FREE AREA IN SQUARE INCHES
EACH OPENING FURNACE ONLY)
Furnace
Maximum
BTUH/INPUT
Rating
60,000
80,000
100,000
120,000
From
Inside
LESS THAN 50 CU. FT.
PER 1000 BTU/HR. INPUT
ALL EQUIP. INSTALLED
TABLE 2
Air
lOO
lOO
lOO
12o
Air From Outside
Vertical
Duct
15
20
25
30
Horizontal
Duct
30
40
50
60

iiiiiiiiiiii
Installer's Guide
®
CONFINED SPACE
AIR FROM INSIDE BUILDING
CONFINED
SPACE
_J
®
CONFINED SPACE
AIR FROM OUTDOORS
L
CONFINED-
SPACE
CONFINED SPACE k
AIR FROM VENTILATED ATTIC/CRAWL SPACE
_ ATTIC LOUVERS
CONFINED - AIR
SPACE
ALTERNATE INLET
INLET A_R _ AIR DUCT
PERMANENT
OPENINGS
,UTLET
DOORS
DUCT CONNECTIONS
Air duct systems should be installed in accordance with
standards for air conditioning systems, National Fire Protec-
tion Association Pamphlet No. 90. They should be sized in
accordance with ACCA Manual D or whichever is applicable.
Central furnaces, when used in connection with cooling units,
shall be installed in parallel or on the upstream side of the
cooling coil to avoid condensation in the heat exchanger. With
a parallel flow arrangement, the dampers or other means used
to control flow of air shall be adequate to prevent chilled air
from entering the furnace, and if manually operated, must be
equipped with means to prevent operation of either unit
unless the damper is in full heat or cool position.
On any job, flexible connections of nonflammable material may
be used for return air and discharge connections to prevent
transmission of vibration. Though these units have been
specifically designed for quiet, vibration free operation, air ducts
can act as sounding boards and could, if poorly instMled,
amplify the slightest vibration to the annoyance level.
When the furnace is located in a utility room adjacent to the
living area, the system should be carefully designed with
returns to minimize noise transmission through the return
air grille. Although these furnaces are designed with large
blowers operating at moderate speeds, any blower moving a
high volume of air will produce audible noise which could be
objectionable when the unit is located very close to a living
area. It is often advisable to route the return air ducts under
the floor or through the attic. Such design permits the
installation of air return remote from the living area (i.e.
central hall).
When the furnace is installed so that the supply ducts carry
air circulated by the furnace to areas outside the space
containing the furnace, the return air shall also be handled
by a duct(s) sealed to the furnace and terminating outside
the space containing the furnace.
RETURN AIR DUCT SYSTEMS
Where there is no complete return duct system, the
return connection must be run full size from the
furnace to a location outside the utility room, base-
ment, attic, or crawl space.
Do Not install return air through the back of the furnace
cabinet.
Do Not install return air through the side of the furnace
cabinet on horizontal applications.
NOTE:
Minimum return air temperature is 55 ° F.
CONFINED SPACE
AIR FROM VENTILATED ATTIC
CONFINED-
SPACE
INLET
AIR DUCT
8 18-CD19D8-15
:LOUVERS
TO OUTDOORS
All return air duct systems should provide for installation of
return air filters.
1. Set the furnace in place.
2. For upflow side return installations, remove the insula-
tion around the opening in the blower compartment.
3. The side panels of the upflow furnace include locating
notches that are used as guides for cutting an opening
for return air, refer to Figure 11 and the outline
drawing on page 4 for duct connection dimensions for
various furnaces.
NOTE:
On upflow 5 ton airflow models, if the airflow requirement
exceeds 1800 CFM, these models will require return air
openings and filters on both sides; OR 1side and the
bottom; OR just the bottom.

Installer's Guide
4. Ifa 3/4" flange is to be used for attaching the air inlet duct,
add to cut where indicated by dotted lines in Figure 11.
Cut corners diagonally and bend outward to form flange.
5. If flanges are not required, and a filter frame is installed,
cut between locating notches (Figure 11).
6. The bottom panel of the upflow furnace must be re-
moved for bottom return air. Remove the filter and lay
the furnace on its back. Remove the two 1/4" hex screws
securing the bottom front channel to the cabinet. Lower
the front edge of the bottom front channel and pull
forward to remove the channel. The bottom return air
panel will now easily slide out of the cabinet. Reinstall
the bottom front channel and filter for upflow bottom
return installations.
7. The filter retainer is factory supplied for upflow bottom
return. Use the filter retainer on side or bottom if filter
is to be used within the furnace cabinet on upflow only
installations.
8. The horizontal installation of the upflow furnace
requires an external filter section. Do NOT use the
bottom return filter within the furnace. Filter kits
are available for horizontal applications.
9. Connect duct work to furnace. See Outline Drawing for
supply and return duct size and location. Flexible duct
connectors are recommended to connect both supply and
return air ducts to the furnace. If only the front of the
furnace is accessible, it is recommended that both supply
and return air plenums are removable.
NOTE:
On upflow 5 ton airflow models, if the airflow requirement
exceeds 1800 CFM, these models will require return air
openings and filters on both sides; OR 1 side and the
bottom; OR just the bottom.
The upflow furnace blower door has a hinge at the bottom
which allows the door to tilt forward for filter replacement
without the door being removed (See Figure 12). The furnace
filter in the bottom or side configuration can be removed by
simply turning the two latches on the blower door and tilting
the door forward.
The filter rails are spring loaded for automatic adjustment to
allow standard size, locally obtainable replacement filters.
The filter rack itself slides to adjust to the required width
needed for bottom or side return (See Figure 13).
BOTTOM FILTER RACK INSTALLATION
With the filter removed, the filter rack is compressed and
then inserted into the bottom of the furnace. The retaining
screw/pin on each side inserts into engagement holes at the
bottom of the furnace cabinet side.
RETURN AIR FILTERS (NOT SUPPLIED)
TYPICAL UPFLOW RETURN AIR FILTER
INSTALLATIONS
Filters are not factory supplied for these furnaces. These
furnaces require high velocity type air filters. The filters may
be located within the furnace blower compartment for
UPFLOW furnaces in either a BOTTOM or SIDE (left side or
right side) return air inlet. Some filters may need to be
trimmed for side or bottom filter use.
TABLE 3
MODELS CABINET FILTER
NUMBERS WIDTH QTY & SIZE
*UX2B060A9362A
*UX2B080A9422A
*UX2C100A9482A 21" 1 - 20" X 25" X 1"
*UX2D120A9602A 24-1/2" 1 - 24" X 25" X 1"
* Firstletter may be "A" or "T"
** NOTE - On 5 ton airflow models, if the airflow requirementexceeds
1800CFM, these models will require return air openings andfilters
on bothsides; OR 1sideand the bottom;OR just the bottom.
®
LOCATING *_
VIDED FOR SIDE
NOTCHES PRO-
RETURN CUTOUT
UPFLOW FURNACE ONLY
17-1/2" 1- 17"X25"X 1"
I
-,. I/-
I
q
4..
J
j CUT OUT FOR
SIDE FILTER
I
*- I
Blower Door Hinge and Bottom Filter Rack Installation
®
FILTER
RACK
RAILS
'_ SPRINGS
AUTOMATIC
ADJUSTMENT
RETAINING
PIN
(Both Sides)
*SEE OUTLINE DRAWING _ of Furnace
"_ ,_ RONT
18-CD19D8-15 9
Optional Filter Rack Accessory Kit - BAYRACK960A

Installer's Guide
",.: ..... ..
_ _ BOTTOM ENGAGEMENT
BlowerDeck _ II Furnace "
Engagement II • " II Cabinet
Filter Rack
Retaining
Screw/Pin Filter
Rack
iiiiiiiiiiii
iiii II _ II Side
ENGAGEMENT
HOLE DETAIL
(Typical both sides
and blower deck) BLOWER EngagementHole
OPTIONAL FILTER RACK INSTALLATION FOR SIDE RE-
TURN AIR ON UPFLOW FURNACES (Left or Right)
If side air return is desired, it is necessary to move the filter
rack from the bottom of the furnace and reinstall it on the
side. The following instructions should be used:
a. Open or remove the blower door.
b. Remove the filter.
c. Compress the filter rack to disengage the retaining
d. Leave the bottom panel in place.
e. After the side cutout is made following the directions
f. Reinstall the furnace filter on the side inserting the
!'" '_" I1..... 11 _lnstallation With_)_Bottom Return
pins/screws from the furnace sides and slide the filter
rack out.
in the "Return Air Duct Connections" section on
pages 8 and 9, compress the filter rack and reinstall
in the side of the furnace. Confirm that the upper
retaining pin/screw locks into the engagement hole in
the blower deck and the lower pin/screw rests against
the side of the bottom panel. See Figures 15-19.
chamfer end first.
Engagement Hole
For Filter Rack
For Filter Rack
Installation With
Side Return
Furnace
Cabi net .,.,,)_
Side
Retaining Rack
Screw/Pin Assembly
SIDE
CUTOUT
\
®
Furnace
Cabinet
Side
Filter
Rack
RETAINING
PIN -_
Bottom Panel
Furnace
Blower
Deck
F
EngagementHole
ForFilter Rack
InstallationWith
BottomReturn
10 18-CD19D8-15
Filter Rack
Retaining
Screw/Pin
(Bo_[__,
III J/ FILTER BOTTOM
I I.] JJ RACK PANEL
[[I // RAILS INSTALLED
I[ V/zJ Typical Upflow Left Side Return Filter
L_z/Rack Installation
Optional Filter Rack Accessory Kit - BAYRACK960A

Typical Upflow Right Side Return Filter Rack Installation
O
Installer's Guide
BLOWER DOOR/HINGE REMOVAL
If clearance or other problems create a problem in using the
tilting door, the blower door hinge may be removed without
creating any problems with the seal of the furnace. To remove
the blower door, tilt the door forward 2 to 3 inches and pull up.
To remove the tilt feature, simply remove the lower hinge as
shown in Figure 22. The bottom of the blower door will catch
in the bottom of the furnace front channel for door replacement.
CHAMFER
END OF
FILTER GOES
INTO FILTER
RACK FIRST
RETURN AIR FILTERS FOR UPFLOW FURNACE IN
HORIZONTAL CONFIGURATION
When the Upflow Furnace is installed in the horizontal
configuration, the return air filters must be installed exterior
to the cabinet. Remote filter grilles may be used for home-
owner convenience or the filters may be installed in the duct
work upstream of the furnace. See Figure 21.
f_
Door Hinge Removed
ALTERNATE UPFLOW FILTER CLIP / BRACKET
INSTALLATION (KIT09224)
1. Determine the location to be used. The furnace cabinet
has dimples for location of the alternate furnace clips
(Side return only). Pre-drill clearance holes with a 3/16"
drill. Bottom return holes are pre-drilled.
2. Install the clips in front and rear of the desired location
using the screws provided. The filter clip with the leaf
spring mounts in the rear of the cabinet.
ALTERNATE FILTER
CLIPS LOCATION
TYPICAL RETURN AIR FILTER INSTALLATION IN
UPFLOW MODEL IN HORIZONTAL POSITION
18-CD19D8-15 11
FILTER CLIP - KIT09224

Installer's Guide
iiiiiiiiiiii
INSTALLING THE FILTER
The filter may need to be cut to fit the unit depending on the
location of the return air filter.
A score line and the words "CUT HERE" are located on the
end of the filter. If your application requires cutting the
filter, do so as indicted by the score mark.
UNIT
SIZE
17-1/2"
21"
24-1/2"
TYPICAL DOWNFLOW FURNACE RETURN AIR FILTER
INSTALLATIONS
Two filters are factory supplied for each downflow furnace.
These furnaces require high velocity type air filters. Down-
flow furnace filters must be located outside the furnace
cabinet. Typical installations are shown in Figure 24.
Tables 5 and 6 provide information for installation of the
filter retaining brackets shipped with downflow furnaces.
@
Optional
BAYFLTR206
Door Kit
BOTTOM
DO NOT CUT
DO NOT CUT
DO NOT CUT
RETURN AIR
SIDE
DO NOT CUT
CUT ON LINE
CUT ON LINE
TABLE 4
MODELS CABINET FILTER
NUMBERS WIDTH QTY & SIZE
*DX060R936
*DX080R942
*DX100R948 21" 2 - 16" X 20" X 1"
*DX120R960 24-1/2" 2 - 16" X 20" X 1"
*First letter may be "A" or "T"
LOCATING FILTER RETAINER BRACKETS IN
CABINET RETURNDUCT DIMENSION DIMENSION BRACKET
WIDTH WIDTH "A .... B" LOCATION*
17-1/2" 16-1/4" 15" 14" 14-3/8"
21" 19-3/4" 19-1/2" 14" 13-1/8"
24-1/2" 23-1/4" 22" 14" 13-5/8"
* LOCATION DIMENSION IS FROM END OF DUCT AGAINST THE FURNACE TO THE
SCREW HOLES FOR THE BRACKET.
BOptiyFLnTRI06
17-1/2" 2 - 14" X 20" X 1"
TABLE 5
DUCTWORK
FILTER
p.
Airflow
DOWNFLOW
/ ow% ow;
TABLE 6
MINIMUM CLEARANCE FROM COMBUSTIBLE MATERIALS FOR
UPFLOW/HORIZONTAL AND DOWNFLOW/HORIZONTAL FURNACES
UNIT LOCATION
FURNACE SURFACE
SIDES 0" 1" 0"
BACK 0" 3" 6"
TOP 1" 1" 1"
FRONT 3" 3" 18"
VENT 0" 0" 0"
NOTE: CLEARANCE REQUIRED AT TOP OF PLENUM IS 1"
12 18-CD19D8-15
VERTICAL HORIZONTAL HORIZONTAL
CLOSET CLOSET ALCOVE / ATTIC