Model No.
POWER CONNS. — V/PH/HZ
(a)
4TTR3018H1000N 4TTR3024H1000N 4TTR3030H1000N 4TTR3036H1000N
(b)
208/230/1/60 208/230/1/60 208/230/1/60 208/230/1/60
MIN. BRCH. CIR. AMPACITY 12 17 16 18
BR. CIR. PROT. RTG. — MAX. (AMPS)
COMPRESSOR
20 25 25 30
CLIMATUFF®-
SCROLL
CLIMATUFF®-
SCROLL
CLIMATUFF®-
SCROLL
CLIMATAUFF®-
SCROLL
RL AMPS — LR AMPS 9 — 48 12.8 — 58.3 12.3 — 63 14.1— 75
Outdoor Fan FL AMPS 0.64 0.64 0.9 0.7
Fan HP
Fan Dia (inches)
1/8 1/8 1/8 1/8
23.0 23.0 18.9 23.0
Coil SPINE FIN™ SPINE FIN™ SPINE FIN™ SPINE FIN™
Refrigerant R-410A 5 LBS., 11 OZ 5 LBS., 9 OZ 4 LBS., 10 OZ 4 LBS., 13 OZ
LINE SIZE — IN. O.D. GAS
LINE SIZE — IN. O.D. LIQ.
Charge Spec. Subcooling
Dimensions H x W X D Crated (IN.)
Weight — Shipping (lbs.)
Weight — Net (lbs.)
(c)
(c)
3/4 3/4 3/4 3/4
3/8 3/8 3/8 3/8
10°F 10°F 10°F 10°F
34 x 30.1 x 33 34 x 30.1 x 33 30 x 27 x 30 34 x 30.1 x 33
167 169 157 175
140 142 137 147
Optional Accessories:
Anti-short Cycle Timer
Evaporator Defrost Control
TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A
AY28X079 AY28X079 AY28X079 AY28X079
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101
Extreme Condition Mount Kit BAYECMT023 BAYECMT023 BAYECMT023 BAYECMT023
Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263 BAYKSKT263
Crankcase Heater Kit BAYCCHT302 BAYCCHT302 BAYCCHT302 BAYCCHT302
Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001 BAYSEAC001
Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103 BAYLOAM103
Refrigerant Lineset
(a)
Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240.
(b)
Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
(c)
Standard line lengths — 60’, Standard lift — 60’ Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32–3312–0* (* denotes latest revision)..
(d)
* = 15, 20, 25, 30, 40 and 50 foot lineset available.
(d)
TAYREFLN950 TAYREFLN950 TAYREFLN7* TAYREFLN7*
2
PPrroodduucctt SSppeecciiffiiccaattiioonnss
Model No.
POWER CONNS. — V/PH/HZ
(a)
(b)
4TTR3042E1000N 4TTR3048E1000N 4TTR3060D1000N
280/230/1/60 280/230/1/60 280/230/1/60
MIN. BRCH. CIR. AMPACITY 22 28 35
BR. CIR. PROT. RTG. — MAX. (AMPS)
COMPRESSOR
CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL CLIMATUFF®- SCROLL
35 45 60
RL AMPS — LR AMPS 17.0 — 124 21.8 — 117 26.8 — 134
Outdoor Fan FL AMPS 0.7 0.93 0.93
Fan HP
Fan Dia (inches)
1/8 1/5 1/5
23 23 27.5
Coil SPINE FIN™ SPINE FIN™ SPINE FIN™
Refrigerant R-410A 5 LBS., 8 OZ 6 LBS., 7 OZ 8 LBS., 0 OZ
LINE SIZE — IN. O.D. GAS
LINE SIZE — IN. O.D. LIQ.
Charge Spec. Subcooling
Dimensions H x W X D Crated (IN.)
Weight — Shipping (lbs.)
Weight — Net (lbs.)
(c)
(c)
7/8 7/8 7/8
3/8 3/8 3/8
10°F 10°F 10°F
34 x 30.1 x 33 42 x 30.1 x 33 42.4 x 35.1 x 38.7
200 233 261
172 197 226
Optional Accessories:
Anti-short Cycle Timer
Evaporator Defrost Control
TAYASCT501A TAYASCT501A TAYASCT501A
AY28X079 AY28X079 AY28X079
Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101
Extreme Condition Mount Kit BAYECMT004 BAYECMT004 BAYECMT004
Start Kit BAYKSKT263 BAYKSKT263 BAYKSKT263
Crankcase Heater Kit BAYCCHT301 BAYCCHT301 BAYCCHT301
Seacoast Kit BAYSEAC001 BAYSEAC001 BAYSEAC001
Low Ambient Kit BAYLOAM103 BAYLOAM103 BAYLOAM103
Refrigerant Lineset
(a)
Certified in accordance with the Unitary Air-conditioner equipment certification program which is based on AHRI standard 210/240.
(b)
Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
(c)
Standard line lengths — 60’, Standard lift — 60’ Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub#32–3312–0* (* denotes latest revision)..
(d)
* = 15, 20, 25, 30, 40 and 50 foot lineset available.
(d)
TAYREFLN7* TAYREFLN3* TAYREFLN3*
Sound Power Level
A-Weighted
MODEL
Sound Power
Full Octave Sound Power(dB)
Level [dB(A)]
63
125Hz250Hz500Hz1000Hz2000
Hz*
Hz
4000
Hz
8000
4TTR3018H1 72 73.7 71.4 65.4 68 67.3 62.9 56 50.3
4TTR3024H1 74 47.9 60.5 64.1 71.2 71.2 69.0 58.2 51.5
4TTR3030H1 72 69.9 69.6 69.1 68.6 68.7 60.9 56.2 48.9
4TTR3036H1 68 74.7 65.0 65.2 66.4 63.6 58.7 56.3 52.8
4TTR3042E1 72 77.6 68.3 67.4 65.6 67.4 58.2 54.1 47.6
4TTR3048E1 74 72.5 72.3 69.2 67.5 72.3 60.2 55.2 54.2
4TTR3060D1 80 47.3 55.7 69 72.7 75.8 69.4 62.2 53.3
Note: Rated in accordance with
*For Reference Only
AHRI Standard 270–2008
Hz
3

Accessory Description and Usage

4 T W V 0 0 3 6 A 1 0 0 0 A A
AAnnttii--SShhoorrtt CCyyccllee TTiimmeerr — Solid state timing device that prevents compressor recycling until five (5) minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc.
EEvvaappoorraattiioonn DDeeffrroosstt CCoonnttrrooll — SPST Temperature actuated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV.
RRuubbbbeerr IIssoollaattoorrss — Five (5) large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmission needs to be minimized.
HHaarrdd SSttaarrtt KKiitt — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc.
EExxttrreemmee CCoonnddiittiioonn MMoouunntt KKiitt — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc.
AAHHRRII SSttaannddaarrdd CCaappaacciittyy RRaattiinngg CCoonnddiittiioonnss
AHRI Standard 210/240 Rating Conditions
1. Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil.
2. High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB air entering indoor coil.
3. Low Temperature Heating 17°F DB air entering indoor coil.
4. Rated indoor airflow for heating is the same as for cooling.
AAHHRRII SSttaannddaarrdd 227700 RRaattiinngg CCoonnddiittiioonnss — (Noise rating numbers are determiend with the unit in cooling operations.) Standard Noise Rating number is at 95°F outdoor air.

Model Nomenclature

4

Schematic Diagrams

Figure 1. 1.5 — 4.0 Ton Models
5
SScchheemmaattiicc DDiiaaggrraammss
Figure 2. 5.0 Ton Models
6

Outline Drawing

Model Base A B C D E F G H J K
4TTR3018H 2
4TTR3024H 2
4TTR3030H 2
4TTR3036H 3
4TTR3042E 3
4TTR3048E 3
4TTR3060D 4
730
(28–3/4)
730
(28–3/4)
730
(28–3/4)
730
(28–3/4)
730
(28–3/4)
730
(28–3/4)
943
(37–1/8)
724
(28–1/2)
724
(28–1/2)
724
(28–1/2)
829
(32–5/8)
829
(32–5/8)
933
(36–3/4)
946
(37–1/4)
651
(25–5/8)
651
(25–5/8)
651
(25–5/8)
756
(29–3/4)
756
(29–3/4)
756
(29–3/4)
870
(34–1/4)
3/4 3/8
3/4 3/8
3/4 3/8
3/4 3/8
7/8 3/8
7/8 3/8
7/8 3/8
127
(5)
137
(5–3/8)65(2–5/8)
137
(5–3/8)65(2–5/8)
137
(5–3/8)79(3–1/8)
152
(6)
152
(6)
152
(6)
57
(2–1/4)
98
(3–7/8)
98
(3–7/8)
98
(3–7/8)
194
(7–5/8)38(1–1/2)
210
(8–1/4)57(2–1/4)
210
(8–1/4)57(2–1/4)
197
(7–3/4)60(2–3/8)
219
(8–5/8)86(3–3/8)
219
(8–5/8)
219
(8–5/8)86(3–3/8)
86
(3–3/8)
457
(18)
457
(18)
457
(18)
508
(20)
508
(20)
508
(20)
508
(20)
7

Mechanical Specification Options

GGeenneerraall
The Outdoor Units are fully charged from the factory for up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities are matched with a wide selection of air handlers and furnace coils that are AHRI certified. The unit is certified to UL 1995. Exterior is designed for outdoor application.
CCaassiinngg
Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint finish on all louvered panels and the fan top panel. The corner panels are prepainted. All panels are subjected to our 1,000 hour salt spray test . The base is made of a CMBP-G30 weatherproof material to resist corrosion.
RReeffrriiggeerraanntt CCoonnttrroollss
Refrigeration system controls include condenser fan, compressor contactor and high pressure switch. High and low pressure controls are inherent to the compressor. A factory supplied liquid line drier is standard. Some models may require field installation.
CCoommpprreessssoorr
The compressor features internal over temperature, pressure protection and total dipped hermetic motor. Other features include: Centrifugal oil pump and low vibration and noise.
CCoonnddeennsseerr CCooiill
The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels.
LLooww AAmmbbiieenntt CCoooolliinngg
As manufactured, this system has a cooling capacity to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F.
TThheerrmmoossttaattss—Cooling only and heat/cooling (manual and automatic change over). Sub-base to match thermostat and locking thermostat cover.
EEvvaappoorraattoorr DDeeffrroosstt CCoonnttrrooll — See Low Ambient Cooling.
Ingersoll Rand (NYSE:IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands—including Club Car
®
, Ingersoll Rand®, Thermo King®and Trane®—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. For more information, visit www.ingersollrand.com.
Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice.
©2016 Ingersoll Rand All rights reserved
22-1842-8D-EN
Supersedes 22-1842-8C-EN (February 2015)
25 Aug 2016
Loading...