Trane XL14i, 2TWX4018-060, 2TWX4018B1, 2TWX4024B1, 2TWX4030B1 Product & Performance Data

...
SS-PRC007-EN
Split System Heat Pump Product & Performance Data
XL14i
2TWX4018-060
1½ – 5 Tons
PUB. NO. 22-1750-05
Features and Benefits
Climatuff® compressor
• Efficiency up to 15.25 SEER and
9.6 HSPF
• All aluminum Spine Fin™ coil
WeatherGuard™ II top shields unit
DuraTuff™ base, fast complete drain, weather proof
WeatherGuard™ fasteners
• XL seacoast shield
• Industry leading appearance
• Tarpaulin gray cabinet with anthracite gray top
• Low sound with advanced fan system and compressor sound insulator
Quick-Sess™ cabinet, service access and refrigerant connections with full coil protection
• Demand defrost control with diagnostics
• Glossy corrosion resistant finish
• Internal compressor pressure/ temperature protection
• 018,024,060 ship with start kit
• Liquid line filter-drier
Comfort “R”™ mode approved
• Easy single side service
• Multi-use liquid and suction line service valves
• Easy top & fan removal
• Full length control and service valve cover
• R-22 refrigerant
• Compressor sump heat
• S.E.E.T. design testing
• 100% line run test
• Low ambient cooling to 55°F as shipped
• Low ambient cooling to 40°F with EDC accessory AY28X084
• Low ambient cooling to 30°F with EDC accessory AY28X084 and TXV
Extended warranties available
© 2009 Trane 2 22-1750-05
Contents
Features and Benefits 2
General Data 4
Product Specifications 4 A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 5 ARI Standard Capacity Rating Conditions 5
Model Nomenclature 6
Electrical Data 7
Dimensions 9
Mechanical Specification Options 11
22-1750-05 3
General Data
Product Specifications
Model No.
Electrical Data V/Ph/Hz
1
2
2TWX4018B1 2TWX4024B1 2TWX4030B1 2TWX4036B1
200/230/1/60 200/230/1/60 208/230/1/60 208/230/1/60 Min Cir Ampacity 8 11 18 21 Max Fuse Size (Amps) 15 15 30 35
Compressor CLIMATUFF
®
CLIMATUFF
®
CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL RL Amps - LR Amps 6.2 - 45 8.3 - 62 13.5 - 73 16.0 - 88 Outdoor Fan FL Amps 0.60 0.90 1.30 1.30 Fan HP 1/15 1/8 1/6 1/6 Fan Dia (inches) 23 23 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-22 7/12-LB/OZ 8/00-LB/OZ 7/10-LB/OZ 8/15-LB/OZ Line Size - (in.) O.D. Gas Line Size - (in.) O.D. Liquid
3
3
5/8 3/4 3/4 7/8 1/4 5/16 5/16 3/8
Dimensions H x W x D (Crated) 43.6 x 30.1 x 33 47.6 x 30.1 x 33 45.4 x 35.1 x 38.7 49.4 x 35.1 x 38.7 Weight - Shipping 249 263 276 295 Weight - Net 215 228 232 249
Start Components YES YES NO NO Sound Enclosure YES YES YES YES Compressor Sump Heat YES YES YES YES
Optional Accessories:
4
Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A/C AY28X084 AY28X084 AY28X084 AY28X084 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 Refrigerant Lineset
1
Certified in accordance with the Air-Source Unitary Heat Pump Equipment certification program which is based on ARI Standard 210/240.
2
Calculated in accordance with N.E.C. Only use HACR circuit breakers or fuses.
3
Standard line lengths - 60'. Standard lift - 60' Suction and Liquid line. For Greater lengths and lifts refer to refrigerant piping software Pub# 32-3312-0
4
For accessory description and usage, see page 5.
5
* = 15, 20, 25, 30, 40 and 50 foot lineset available.
5
TAYREFLN1* TAYREFLN2* TAYREFLN2* TAYREFLN3*
. (†denotes latest revision)
A-weighted Sound Power Level [dB(A)]
SOUND POWER A-WEIGHTED FULL OCTAVE SOUND POWER LEVEL dB - [dB(A)]
MODEL LEVEL [dB(A)] 63 125 250 500 1000 2000 4000 8000
2TWX4018B1 71 47.8 55.0 60.2 64.3 65.0 61.8 56.8 57.5
2TWX4024B1 74 48.3 54.1 58.8 63.5 69.7 66.1 59.0 56.6
2TWX4030B1 73 47.2 59.5 60.6 66.5 67.1 62.3 55.5 51.2
2TWX4036B1 74 47.8 57.7 64.0 66.4 69.3 61.7 55.0 48.8
2TWX4042B1 74 50.2 58.8 64.2 65.7 71.0 63.4 56.0 53.1
2TWX4048B1 74 50.2 58.8 64.2 65.7 71.0 63.4 56.0 53.1
2TWX4060B1 74 50.6 55.2 62.0 69.3 69.3 65.6 64.7 53.7
Note: Tested in accordance with ARI Standard 270.95. (Not listed with ARI)
4 22-1750-05
General Data
Product Specifications
Model No.
Electrical Data V/Ph/Hz Min Cir Ampacity 2 4 2 8 3 4 Max Fuse Size (Amps) 4 0 4 5 5 0
Compressor CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL CLIMATUFF® - SCROLL RL Amps - LR Amps 17.9 - 104 21.2 - 137 25.0 - 148 Outdoor Fan FL Amps 1.30 1.30 2.80 Fan HP 1 / 6 1 / 6 1 / 3 Fan Dia (inches) 27.6 27.6 27.6
Coil Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-22 9/10-LB/OZ 10/05-LB/OZ 11/12-LB/OZ Line Size - (in.) O.D. Gas Line Size - (in.) O.D. Liquid
Dimensions H x W x D (Crated) 53.4 x 35.1 x 38.7 53.4 x 35.1 x 38.7 53.4 x 35.1 x 38.7 Weight - Shipping 3 1 0 3 1 4 3 3 9 Weight - Net 2 6 1 2 6 6 2 9 0
Start Components N O N O Y E S Sound Enclosure Y E S Y E S Y E S Compressor Sump Heat Y E S Y E S Y E S
Optional Accessories: Anti-short Cycle Timer TAYASCT501A TAYASCT501A TAYASCT501A Evaporator Defrost Control A/C AY28X084 AY28X084 AY28X084 Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg - Base & Cap 4" High BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg - 4" Extension BAYLEGS003 BAYLEGS003 BAYLEGS003 Hard Start Kit Scroll BAYKSKT260 BAYKSKT260 Extreme Condition Mounting Kit B A YECMT004 BAYECMT004 BAYECMT004 Refrigerant Lineset
1
5
2
4
3
3
2TWX4042B1 2TWX4048B1 2TWX4060B1
208/230/1/60 208/230/1/60 208/230/1/60
7/ 8 1-1/8 1-1/8 3/8 3/8 3/8
TAYREFLN3* TAYREFLN4* TAYREFLN4*
Accessory Description and Usage
Anti-Short Cycle Timer — Solid state timing device that
prevents compressor recycling until 5 minutes have elapsed after satisfying call or power interruptions. Use in area with questionable power delivery, commercial applications, long lineset, etc.
Evaporator Defrost Control — SPST Temperature actu­ated switch that cycles the condenser off as indoor coil reaches freeze-up conditions. Used for low ambient cooling to 30°F with TXV.
Rubber Isolators — 5 large rubber donuts to isolate condensing unit from transmitting energy into mounting frame or pad. Use on any application where sound transmis­sion needs to be minimized.
Hard Start kit — Start capacitor and relay to assist compressor motor startup. Use in areas with marginal power supply, on long linesets, low ambient conditions, etc.
Extreme Condition Mount Kit — Bracket kits to securely mount condensing unit to a frame or pad without removing any panels. Use in areas with high winds, or on commercial roof tops, etc.
22-1750-05 5
ARI Standard Capacity Rating Conditions
ARI STANDARD 210/240 RATING CONDITIONS
(A) Cooling 80°F DB, 67°F WB air entering indoor coil,
95°F DB air entering outdoor coil.
(B) High Temperature Heating 47°F DB, 43°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(C) Low Temperature Heating 17°F DB, 15°F WB air entering
outdoor coil, 70°F DB air entering indoor coil.
(D) Rated indoor airflow for heating is the same as for cooling.
ARI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation.) Standard Noise Rating number is at 95°F outdoor air.
SPLIT SYSTEM
Model Nomenclature
Outdoor Units
Refrigerant Type
2 = R-22 4 = R-410A
TRANE
Product Type
W = Split Heat Pump T = Split Cooling
Product Family
Z = Leadership – Two Stage X = Leadership R = Replacement/Retail B = Basic A = Light Commercial
Family SEER
0 = 10 3 = 13 6 = 16 1 = 11 4 = 14 8 = 18 2 = 12 5 = 15 9 = 19
Split System Connections 1-6 Tons
0 = Brazed
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60
Secondary Function
Minor Design Modifications
Unit Parts Identifier
2TWX4036B1 000AA
Heat Pump/ Cooling Coils
Gas Furnaces
Air Handlers –
4TEE3 F3 6A1 A A000
Residential
Refrigerant Type
4 = R-410A 2 = R-22
Application
TE = Fully Convertible TG = Semi Convertible TF = Front Return TV = Vertical
Product Family
E = Leadership – Variable Speed P = Leadership C = Replacement/Retail B = Basic
Flow Control
3 = Nonbleed TXV 4 = FCCV*
Feature Identifier
0 = Standard Unit F = Air-Tite™
Nominal Capacity in 000s of BTUs
Major Design Modifications
Power Supply
1 = Single Phase
Electrical Connection
0 = Pig Tails B = Circuit Breaker D = Pull Disconnect
Future Option – Factory Installed Heater Nominal KW Value
Minor Design Modifications
Unit Parts Identifier
NOTE: There will be a phase-in of new model numbers for new air handlers over next 2 years. *Shipped with R-22 FCCV
6 22-1750-05
Electrical Data
Schematic Diagrams
(SEE LEGEND)
2TWX4018,024B 2TWX4030,036,42B
Printed from D155609REV00.
22-1750-05 7
Printed from D155610REV00.
Electrical Data
Schematic Diagrams
(SEE LEGEND)
2TWX4048B 2TWX4060B
Printed from D155611REV00.
Printed from D155612REV00.
8 22-1750-05
Electrical Data
Schematic Diagrams
LEGEND
SYMBOLS
22-1750-05 9
Dimensions
2TWX4 Outline Drawing
NOTE: ALL DIMENSIONS ARE IN MM (INCHES)
MODELS BASE FIG. A B C D E F G H J K
2TWX4018B 3 2 1016 (40) 829 (32-5/8) 756 (29-3/4) 5/8 1/4 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 692 (27-1/4)
2TWX4024B 3 2 1118 (44) 829 (32-5/8) 756 (29-3/4) 3/4 5/16 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 692 (27-1/4)
2TWX4030B 4 1 1064 (41-7/8) 946 (37-1/4) 870 (34-1/4) 3/4 5/16 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)
2TWX4036B 4 1 1165 (45-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)
2TWX4042B 4 1 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 7/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 730 (28-3/4)
2TWX4048B 4 1 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 933 (36-3/4)
2TWX4060B 4 1 1267 (49-7/8) 946 (37-1/4) 870 (34-1/4) 1-1/8 3/8 152 (6) 98 (3-7/8) 219 (8-5/8) 86 (3-3/8) 933 (36-3/4)
From Dwg. 21D152635 Rev. 11
10 22-1750-05
Mechanical Specification Options
General
The 2TWX4 shall be fully charged from the factory for matched indoor section and up to 15 feet of piping. This unit must be designed to operate at outdoor ambient temperatures as high as 115°F. Cooling capacities shall be matched with a wide selection of air handlers and furnace coils that are ARI certified. The unit is certified to UL 1995. Exterior must be designed for outdoor application.
Casing
Unit casing is constructed of heavy gauge, galvanized steel and painted with a weather-resistant powder paint. Corrosion and weatherproof CMBP-G30 DuraTuff™ base.
Refrigerant Controls
Refrigeration system controls include condenser fan and compressor contactor. High and low pressure controls are inherent to the compressor. Another standard feature is the liquid line dryer.
Compressor
The Climatuff internal over temperature and pressure protector, total dipped hermetic motor and thermostatically controlled sump heater. Other features include: roto lock suction and discharge refrigeration connections, centrifugal oil pump, and low vibration and noise.
®
compressor features
Condenser Coil
The Spine Fin™ coil shall be continu­ously wrapped, corrosion resistant all aluminum with minimum brazed joints. This coil is 3/8 inch O.D. seamless aluminum glued to a continuous aluminum fin. Coils are lab tested to withstand 2,000 pounds of pressure per square inch. The outdoor coil provides low airflow resistance and efficient heat transfer. The coil is pro­tected on all four sides by louvered panels.
Low Ambient Cooling
As manufactured, this unit has a cooling capability to 55°F. The addition of an evaporator defrost control permits operation to 40°F. The addition of an evaporator defrost control with TXV permits low ambient cooling to 30°F.
Accessories Thermostats — Heating/Cooling
(manual and automatic changeover). Sub-base to match thermostat and locking thermostat cover.
Evaporator Defrost Control — See Low Ambient Cooling.
Outdoor Thermostat — Supplemental heat outdoor ambient lockout from 46 to –10°F.
22-1750-05 11
Trane www.trane.com
Literature Order Number
File Number
Supersedes
Stocking Location 04/09
Trane has a policy of continuous product and product data improvement and it reserves the right to change design and specifications without notice.
Loading...