SPECIFICATIONS
Range: –58.0 to 1832 °F
–50.0 to 1000 °C
Resolution: 0.1° (-9.9 to 199.9)
1° (otherwise)
OPERATION
Press and continue to hold down the
trigger to take temperature readings.
The unit will take temperature readings
while the trigger is pressed and held
(SCAN appearing on the display indicates
measurements are being taken).
After the trigger is released, the last
temperature measured will be displayed
for approximately 7 seconds and the
display will turn off automatically. HOLD
will appear on the display when the
trigger has been released to indicate that
the unit is no longer taking temperature
measurements.
SELECTING UNITS OF MEASURE
While taking measurements, press
the °F button to display the temperature
in °F, press the °C button to display the
temperature in °C. Once the unit has
turned off, the next time the trigger is
pressed, unit of measure will return to the
default of °C.
LASER TARGETING
ð
While taking measurement, press the
button to activate laser targeting. Aim
the laser approximately 1/2 inch above
the desired measurement point. To turn
ð
off laser targeting, press the
again.
CAUTION: Eye damage may result from
direct exposure to laser light.
r
r
button
BACKLIGHT
While taking measurements, press the
button to turn on the LCD backlight.
Press the
LCD backlight.
DISTANCE SPOT/RATIO
There are other factors that may affect
measurement accuracy. The target
must completely ll the spot diameter
seen by the infrared sensor; otherwise
readings will be inuenced by the
surface surrounding the target. The ratio
of the distance to the size of the spot
being measured is 50:1. For example,
an object’s diameter of 100mm can be
measured from 5000mm.
button again to turn off the
DISPLAY MESSAGES
“1” will appear on the display when the
temperature being measured is outside
the range of the unit.
ALL OPERATIONAL DIFFICULTIES
If this thermometer does not function
properly for any reason, replace the
battery with a new high quality battery
(see Battery Replacement section). Low
battery power can occasionally cause
any number of “apparent” operational
difculties. Replacing the battery
with a new fresh battery will solve most
difculties.

BATTERY REPLACEMENT
Erratic readings, faint readings, no display,
or a battery symbol appearing on the
display are all indications that the battery
must be replaced.
Locate the
indentions on either
side of the plastic
case near the trigger.
Open the battery
compartment by
pulling the rubber
portion of the handle
out and away from
the trigger. Pull hard, it requires a good
amount of force to open the battery compartment. Remove the exhausted battery
and replace it with a new 9-volt alkaline
battery. Close the battery cover by snapping it shut.
WARRANTY, SERVICE, OR
RECALIBRATION
For warranty, service, or recalibration,
contact:
CONTROL COMPANY
Control Company is ISO 9001:2008 Quality-Certi ied
by DNV and ISO/IEC 17025:2005 accredited as a
Calibration Laboratory by A2LA.
5 Commonwealth Ave
Woburn, MA 01801
TestEquipmentDepot.com
Traceable® is a registered trademark of Control Company.
©2016 Control Company. 92-4483-00 Rev. 2 061716