TP Link EAP220 Users Manual

Page 1
Installation Guide
Wireless N Gigabit Access Point
EAP120 / EAP220
Page 2
Page 3
CONTENTS
Network Topology Requirements —————————————— 01
Overview ————————————————————————— 02
Hardware Installation ——————————————————— 04
1. Installation Requirements ....................................................... 04
2. Mounting Bracket ................................................................... 04
3. Installation ............................................................................ 05
4. Powering Mode ...................................................................... 09
Getting Started with the EAP ———————————————— 11
Q&A ——————————————————————————— 14
Specications ——————————————————————— 15
Technical Support ————————————————————— 16
About This Installation Guide
This guide is designed to familiarize you with the general layout of the EAP, describe how to deploy the device in your network and how to configure the device. Your EAP has more features and functionalities which can be found in the User Guide.
Page 4
Network Topology Requirements
Typical topology for the EAP is described below.
Enwuvgt
Master EAP Slave EAPSlave EAP
Internet
Router
The EAP120 and EAP220 provide two management modes: Cluster and Standalone. By default,the management mode is Cluster. In this mode, all the EAPs in the same LAN will form a Cluster, and a Master EAP will be elected among them to manage the other EAPs, called Slave EAPs.
A DHCP server is required in the local network to assign IP addresses to the EAPs. A router usually acts as the DHCP server.
Typically, a PoE switch can be used to provide Power over Ethernet for each EAP. Or, each EAP must be powered with a power adapter individually.
Switch
Typical Topology
01
Page 5
Overview
LED Explanation
System LED
Top View of the EAP
LED Status Indication Quickly flashing green System initialization is complete. Solid green The device is working properly. Slowly flashing red The system is abnormal. RAM, Flash, Ethernet,
Quickly flashing yellow Firmware is being updated. Alternating red/green/yellow twice The device is being reset.
WLAN or firmware may be malfunctioning.
Interface Panel
ON/OFF
RESET
CONSOLE ETHERNET
ARROW 1
Interface Panel of the EAP
POWER
The interface panel components of the EAP, from left to right, are described in the following list:
Kensington Security Slot
Secure the lock into the slot to prevent the device from being stolen.
02
Page 6
RESET
With the device powered on, press and hold the RESET button for about 8 seconds, and then release the button. The device will restore to factory default settings.
CONSOLE
This port is used to connect with the serial port of a computer or a terminal to check and monitor simple system information of the device.
ETHERNET
This port is for connection to a router or switch to transmit and receive data as well as to a PSE device for power supply. Power sourcing equipment (PSE) is a device such as a switch that provides power over Ethernet cables to linked devices.
ON/OFF
Press this button to power on/off the device. Please remember to press it to use the device.
POWER
The power jack is for connection to the power adapter. Please use the power adapter provided. Refer to Powering Mode to learn how to power the device via PoE and power adapter.
ARROW 1
To align with ARROW 2 in the mounting bracket before the EAP locks into place. Please refer to Mounting Bracket to locate ARROW 2.
03
Page 7
Hardware Installation
The EAP can be wall or ceiling mounted and can be powered via a PSE device or the provided adapter. Please suitably arrange your wire layout before the mounting.
1. Installation Requirements
Check and prepare the following items in the package for installation.
One EAP
One Mounting Bracket
One Installation Guide
Three Nuts/ Washers/ Plastic Extending Tubes/ Self-tapping Screws/ Pan Head Screws
Besides the above installation kits, these tools may be needed for hardware installation: pencil, ruler, drill, hammer, screwdriver and ladder.
2. Mounting Bracket
The following figure describes the structure of the mounting bracket.
ARROW 2, to align with ARROW 1 under the interface panel
Ceiling mounting slot
Wall mounting slot
Locking clip
Mounting Bracket
04
Page 8
3. Installation
Ceiling Mounting
Note:
Make sure the thickness of the ceiling is less than 18mm and the ceiling can bear at least five kilograms.
If the ceiling is made of low-strength material like gypsum, it is not recommended to mount the EAP on the ceiling. If it has to do, add a layer of strong material under the nut to ensure the EAP is mounted solidly.
1. Remove the ceiling tile.
Remove the Ceiling Tile
2. Place the mounting bracket at the center of the ceiling tile. Mark the positions of three mounting slots and the hole for Ethernet cable to feed through.
L
L≈40mm
Mark of the Hole for Ethernet cable to feed through
Mark the Positions
05
Page 9
3. Use a drill bit to drill three holes for screws, and drill a 10mm hole for the Ethernet cable to feed through.
4mm hole for mounting bracket
10mm hole for Ethernet cable feed
Drill the Holes
4. Secure the mounting bracket to the ceiling board with nuts, washers and pan head screws as shown below.
Nut
Washer
Hole to feed the Ethernet cable
Hole to feed the screw
Pan head screw
Secure the Mounting Bracket
06
Page 10
5. Align ARROW 1 with ARROW 2 as shown below, then press the EAP into the mounting bracket.
RESET
CONSOLE
ETHERNET
ON/OFF
POWER
Align Two Arrows
6. Turn the EAP clockwise until it locks into place.
07
Make the EAP Lock into Place
Page 11
7. Feed the cable through the hole and set the ceiling tile back into place.
Fix the Ceiling Tile
8. Connect the Ethernet cable to the Ethernet port and ceiling mounting is done.
Wall Mounting
There are two wall-mounting slots at the bottom of the EAP. To mount the EAP on a wall, please follow the steps below.
1. Make two small pencil marks on the wall. The distance between the two marks should be 98.6mm.
Wall
L
L=98.6mm
Mark on the Wall
08
Page 12
2. Use a drill bit to drill two holes through the center of your marks. The diameter of both holes should be 4mm.
Wall
4mm in diameter
Drill Two Holes
3. Insert the plastic extending tubes into the 4mm holes and drive the screws into the tubes.
4. As Ceiling Mounting shows, press the EAP into the mounting bracket and turn it clockwise until it locks into place.
5. Simply hang your EAP and the wall mounting is done.
4. Powering Mode
The EAP can be powered via a PSE device (e.g., a PoE switch) or a power adapter.
Via PSE Device
EAP220
2
1
Power the EAP via a PoE
09
TL-SG3424P
Page 13
1. Connect the EAP to a PSE device through an Ethernet cable.
2. Press the ON/OFF button on the interface panel of the EAP.
Via Power Adapter
Socket
TL-SG2008
EAP220
Socket
Power the EAP via a Power Adapter
1. Plug one end of the provided power adapter into the power jack of the EAP, and the other end to a standard electrical wall socket.
2. Press the ON/OFF button on the interface panel of the EAP.
10
Page 14
Getting Started with the EAP
How do you quickly build a wireless network with several EAPs? The following content will instruct you on how to do network connection and software configurations on EAPs. Management host can be connected to the EAPs wirelessly or with wires. Wireless Login is recommended conveniently.
Option 1: Wireless Login
Internet
Router
Switch
Master EAP Slave EAP
Slave EAP
Cluster
Management Host
Sample Network Diagram for Wireless Login
Step 1: Power on
Power on the EAPs. The EAP with system initialization first completed will be elected as the Master.
11
Page 15
Step 2: Wireless Access
1. Make sure the management host is set to obtain IP address automatically.
2. Join the wireless network. The default SSID and password are shown below. SSID: TP-LINK_2.4GHz_XXXXXX or TP-LINK_5GHz_XXXXXX for EAP220; TP
LINK_2.4GHz_XXXXXX for EAP120. XXXXXX is the last 6 characters of EAP's MAC address. Password: Password is empty.
Step 3: Quick Setup
1. Open a web browser and type in http://tplinkeap.net to log in to the EAP. The default user name and password are admin. In the Cluster mode, the login will be directed to the Master EAP.
2. Create a new user name and password
.
3. Follow instructions step by step to complete Quick Setup.
Congratulations! The above configurations on the Master EAP will be synchronized to all the other EAPs automatically. Now you can enjoy the wireless network.
If you want to perform more configurations, please connect to the new SSID.
Option 2: Wired Login
Internet
-
Cluster
Switch
Master EAP
Router
Management Host
Slave EAPSlave EAP
Sample Network Diagram for Wired Login
12
Page 16
Step 1: Power on
Power on the EAPs. The EAP with system initialization first completed will be elected as the Master.
Step 2: Wired Access
1. Make sure the management host is set to obtain IP address automatically.
2. Access your DHCP server and locate the IP address of the EAPs.
Step 3: Quick Setup
1. Open a web browser, in the address field type in any IP address of the EAPs to log in the web server. The default user name and password are admin. In the Cluster mode, the login will be directed to the Master EAP.
2. Create a new user name and password.
3. Follow instructions step by step to complete Quick Setup.
Congratulations! The above configurations on the Master EAP will be synchronized to all the other EAPs automatically. Now you can enjoy the wireless network.
13
Page 17
Q&A
Can Master EAP work as an access point?
Q1.
Yes. In additon to managing and monitoring Slave EAPs, the Master EAP is equipped with the features and functions of an AP, providing wireless access to clients.
What is the maximum number of EAPs in a Cluster?
Q2.
The maximum number of EAPs in a cluster is 24.
Can EAP120 be in the same Cluster with EAP220?
Q3.
No, EAP120 and EAP220 cannot be in the same cluster. Only the EAPs of the same model can be clustered together.
14
Page 18
Specifications
Models EAP120 EAP220 HARDWARE FEATURES
Interface 10/100/1000Mbps Ethernet port (RJ-45)
Console port (RJ-45) Power connector (DC-2) Kensington lock slot
Buttons RESET
ON/OFF (for power supply)
Power Supply PoE or External 12VDC /
1A Power Supply PoE Compatible 802.3af 802.3af Maximum Power Consumption 4.4W 9.6W Antenna 2*4dBi Embedded 4*4dBi Embedded Mounting Ceiling/Wall mounting (Kits included) Certication CE
FCC
RoHS Operating Temperature 0~40 (32~104) Operating Humidity 10%~90% non-condensing
WIRELESS FEATURES
Wireless Frequency 2.4GHz 2.4GHz & 5GHz Wi-Fi Standard IEEE 802.11b/g/n IEEE 802.11a/b/g/n Maximum Data Rate Up to 300Mbps Up to 600Mbps Max RF Transmission Power
Multiple SSIDs Up to eight per radio Captive Portal Authentication Support Wireless Security WEP
Cluster Support, up to 24 APs in a cluster
(1)
23dBm 2.4GHz:23dBm
WPA/WPA2-personal
WPA/WPA2-enterprise
PoE or External 12VDC /
1.5A Power Supply
5GHz:20dBm
15
Maximum transmission power may vary in different countries or regions.
Page 19
Technical Support
For more help, please go to: http://www.tp-link.com/en/support/faq
To download the latest firmware, driver, utility and user guide, please go to: http://www.tp-link.com/en/support/download
For all other technical support, please contact us by using the following details:
Global Tel: +86 755 2650 4400
Australia/New Zealand Tel: AU 1300 87 5465 (Depending on 1300 policy.)
Brazil
France Tel: 0820 800 860 (French service)
Germany/Austria Tel: +49 1805 875 465 (German Service)
Indonesia Tel: (+62) 021 6386 1936
Italy Tel: +39 023 051 9020
Malaysia
Poland Tel: +48 (0) 801 080 618
Fee: Depending on rate of different carriers, IDD. E-mail: support@tp-link.com Service time: 24hrs, 7 days a week
NZ 0800 87 5465 (Toll Free) E-mail: support.au@tp-link.com (Australia) support.nz@tp-link.com (New Zealand) Service time: 24hrs, 7 days a week
Toll Free: 0800 608 9799 (Portuguese Service) E-mail: suporte.br@tp-link.com Service time: Monday to Saturday, 09:00 to 20:00; Saturday, 09:00 to 15:00
Fee: 0.118 EUR/min from France Email: support.fr@tp-link.com Service time: Monday to Friday 9:00 to 18:00 *Except French Bank holidays
+49 1805 TPLINK +49 820 820 360 Fee: Landline from Germany: 0.14EUR/min. Landline from Austria: 0.20EUR/min. E-mail: support.de@tp-link.com Service time: Monday to Friday, 9:00 to 12:30 and 13:30 to 17:30. GMT+ 1 or GMT+ 2 (DST in Germany) *Except bank holidays in Hesse
Fee: Depending on rate of different carriers. E-mail: support.id@tp-link.com Service time: Monday to Friday 9:00 to 18:00 *Except public holidays
Fee: Depending on rate of different carriers. E-mail: support.it@tp-link.com Service time: Monday to Friday, 9:00 to13:00 and 14:00 to 18:00
Toll Free: 1300 88 875 465 Email: support.my@tp-link.com Service time: 24hrs, 7 days a week
+48 223 606 363 (if calls from mobile phone) Fee: Depending on rate of different carriers. E-mail: support.pl@tp-link.com Service time: Monday to Friday 9:00 to 17:00. GMT+1 or GMT+2 (DST)
16
Page 20
Russian Federation Tel: 8 (499) 754 5560 (Moscow NO.)
Singapore Tel: +65 6284 0493
Switzerland Tel: +41 (0) 848 800 998 (German Service)
Turkey Tel: 0850 7244 488 (Turkish Service)
UK Tel: +44 (0) 845 147 0017
Ukraine Tel: 0800 505 508
USA/Canada Toll Free: +1 866 225 8139
8 (800) 250 5560 (Toll-free within RF) E-mail: support.ru@tp-link.com Service time: From 09:00 to 21:00 (Moscow time) *Except weekends and holidays in RF
Fee: Depending on rate of different carriers. E-mail: support.sg@tp-link.com Service time: 24hrs, 7 days a week
Fee: 4-8 Rp/min, depending on rate of different time. E-mail: support.ch@tp-link.com Service time: Monday to Friday, 9:00 to 12:30 and 13:30 to 17:30. GMT+ 1 or GMT+ 2 (DST)
Fee: Depending on rate of different carriers. E-mail: support.tr@tp-link.com Service time: 9:00 to 21:00, 7 days a week
Fee: Landline: 1p-10.5p/min, depending on the time of day. Mobile: 15p-40p/min, depending on your mobile network. E-mail: support.uk@tp-link.com Service time: 24hrs, 7 days a week
Fee: Free for Landline; Mobile: Depending on rate of different carriers. E-mail: support.ua@tp-link.com Service time: Monday to Friday 10:00 to 22:00
E-mail: support.usa@tp-link.com Service time: 24hrs, 7 days a week
17
Page 21
FCC STATEMENT
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
1) This device may not cause harmful interference.
2) This device must accept any interfe may cause undesired operation.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
FCC RF Radiation Exposure Statement:
This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. This device and its antenna must not be co-located or operating in conjunction with any other antenna or transmitter.
“To comply with FCC RF exposure compliance requirements, this grant is applicable to only
Mobile Configurations. The antennas used for this transmitter must be installed to provide a
separation distance of at least 20 cm from all persons and must not be co-located or
operating in conjunction with any other antenna or transmitter.”
manual, may cause harmful interference to radio communications.
rence received, including interference that
CE Mark Warning
or This is a class A product. In a domestic environment, this product may cause radio interference, in which case the user may be required to take adequate measures.
IC Statement
This Class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
Проду к т се р т и фіковано з г і д н о с пр а в и лам и си с теми Ук р С Е П Р О на відповідність вимогам нормативних документів та вимогам, що передбачені чинними законодавчими актами України.
18
Page 22
Safety Information
1) When product has power button, the power button is one of the way to shut off the product; When there is no power button, the only way to completely shut off power is to disconnect the product or the power adapter from the power source.
2) Don’t disassemble the product, or make repairs yourself. You run the risk of electric shock and voiding the limited warranty. If you need service, please contact us.
3) Avoid water and wet locations.
NCC Notice & BSMI Notice
注意!
依據 低功率電波輻射性電機管理辦法 第十二條 經型式認證合格之低功率射頻電機,非經許可,公司、商號或使用者均不得擅自
變更頻 率、加大功率或變更原設計之特 性或功能。 第十四條 低功率射頻電機之使用不得影響飛航安全及干擾合法通行;經發現有干擾現象
時,應立即停用,並改善至無干擾時方 得繼續使用。前項合法通信,指依電信規定作業之 無線電信。低功率射頻電機需忍受合法通信或工業、科學以及醫療用電波輻射性電機設 備之干擾。
減 少 電 磁 波 影 響 ,請 妥 適 使 用 。
安全諮詢及注意事項
●請使用原裝電源供 應器或只能按照本產品注明的電源類型使 用本產品。
●清潔本產品之前請先拔掉電源線。請勿使用液體、噴霧清潔劑或濕布進行清潔。
●注意防潮,請勿將水或其他液體潑灑到本產品上。
●插 槽與開口供 通風使用,以確保本產品的操作可靠並防止過 熱,請 勿堵塞或覆 蓋開口。
●請勿將本產品置放於靠近熱源的地方。除非有正常的通風,否則不 可放在密閉位置中。
●請不要私自打開機殼,不要嘗試自行維修本產品,請由授權的專業人士進行此項工作。 此為甲類資訊技術設備,于居住環境中使用時,可能 會造成射頻擾動,在此種情況下,使
用者會被要求採取某些適當的對策。
This product can be used in the following countries:
AT / BG / BY / CA / CZ / DE / DK / EE / ES / FI / FR / GB / GR / HU / IE / IT
LT / LV / MT / NL / NO / PL / PT / RO / RU / SE / SK / TR / UA / US
19
Page 23
Page 24
COPYRIGHT & TRADEMARKS
Specifications are subject to change without notice. is a registered trademark of TP-LINK TECHNOLOGIES CO., LTD. Other brands and product names are trademarks of their respective holders. No part of the specifications may be reproduced in any form or by any means or used to make any derivative such as translation, transformation, or adaptation without permission from TP-LINK TECHNOLOGIES CO., LTD. Copyright © 2014 TP-LINK TECHNOLOGIES CO., LTD. All rights reserved.
Website: http://www.tp-link.com
Tel: +86 755 26504400
E-mail: support@tp-link.com
7106505003 REV1.0.1