Toyotomi FF-55T Owner's Manual

CONTENTS
Page No
SECTION A:
Specifications ··························································· 1 Safety Features ························································· 2
SECTION B:
Safety Tips for Operation ·········································· 3
SECTION C:
Fuel Guide ································································· 4
SECTION D:
SECTION E:
Operation
Before Ignition ························································ 7 Operation ································································ 9 Turning Heater Off ·············································· 14
Page No
SECTION F:
Routine Maintenance ·············································· 15
SECTION G:
Troubleshooting ······················································ 17
Section H:
Long Term Storage ················································· 18
Section I:
Installation
Standard Installation Parts ··································· 19 Optional Accessory Parts ····································· 20 Installation Advice ················································ 24 Installation of Heater and Flue Pipe ····················· 25 Extension Wire of Room Temperature Sensor ······ 26
MODEL FF 55T (Type B)
IMPORTANT
1) READ AND UNDERSTAND INSTRUCTIONS BEFORE INSTALLING OR USING HEATER.
2) RETAIN INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE.
3) CHECK LOCAL AUTHORITY & BUILDING CODES FOR INSTALLATION REQUIREMENTS.
VENTED HEATING SYSTEM
OPERATION INSTRUCTIONS
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ a
Model: FF 55T
Heater Efficiency: 92.4% (1)
Heat Rating: High - 5.50 kW (18,800 BTU/h)
Med - 3.74 kW (12,800 BTU/h) Low - 1.88 kW ( 6,430 BTU/h)
Fuel Consumption: High - 0.622 L/h
Med - 0.423 L/h Low - 0.213 L/h
Fuel System: Removable fuel tank (7.6L)
Fuel Type: Paraffin only
Dimensions (W × H × D): 496 × 600 × 339 mm
Weight: 20 kg
Vent Pipe Hole: 70 ~ 80 mm diameter
Maximum Length of Vent Pipe System: 3 m, 3 bents or less
Electrical Rating: 220 Volts AC, 50 Hz
Preheat - 240W Burning - 46W
(1) Heat and vaporized water are produced by fuel combustion. Heat rating does not account for heat loss due to
condensation of water vapor.
SECTION A: SPECIFICATIONS
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 1
1
Flame Sensor
Heater will automatically stop all operations if ignition fails or if flame fails during combustion, in order to prevent fuel overflow. Error code will be displayed on the digital indicator.
Overheat Protector
Automatically stops all operations if heater cabinet reaches abnormally high temperature due to motor malfunction or abnormal combustion, in order to prevent fire.
Power Failure Recovery System
If power fails during heater operation, heater will turn off. When power resumes, heater will automatically reignite and maintain the normal selected temperature.
NOTE: The operation varies depending on the time length of power failure and other conditions.
Please see page.14 for more details.
Fully Vented System
Flue pipe system provides outside air for combustion and vents all combustion products to the outdoors.
1.
2.
3.
4.
SAFETY FEATURES
Your heater is equipped with a number of integral safety features. Please familiarize yourself with these features. If the heater shuts down due to the operation of any safety device, ensure the problem is identified and corrected. Note that normal combustion flames inside the combustion chamber, can be seen through a “peep hole”, located in the front bottom left hand corner of the hot air outlet louver’s.
Fuel pipe
Burner ring
Blower motor
Heat exchanger
Burner
Peep hole
Fuel acceptance fitting
Igniter
Fuel pump
Fuel sub tank
Removable fuel tank
Heat shield plate
Overheat protector
Flame sensor
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 2
2
CAUTION: Heater and vent pipe system must be properly installed before operation. Please follow
instructions under “Installation”, Section I.
SECTION B: SAFETY TIPS FOR OPERATION
1. NEVER use any fuel other than Paraffin. NEVER USE GASOLINE. Use of gasoline can lead to uncontrollable flames, resulting in destructive fire.
2. Due to high surface temperatures, keep heater away from children, furniture and clothing while in operation. (See Page 25.)
• The appliance is not to be used by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been give supervision or instruction.
• Children being supervised not to play with the appliance.
• This appliance can be used by children aged from 8 years and above and per­sons with reduced physical, sensory or mental capabilities or lack of experiance and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
• Children shall not play with the appliance.
Cleaning and user maintenance shall not be made by children without supervision.
3. To prevent abnormal operation and prolong heater life, be sure to perform routine maintenance. (See Page 15.)
4. NEVER store or transport fuel in other than a metal or plastic container that is acceptable for fuel and clearly marked “PARAFFIN”. NEVER store fuel in the living space.
5. Operating Temperature Range Use heater within the range of temperatures indicated in the right figure.
Point A: If outside temperature -29˚C
than room temperature has to be -18˚C or above
Point B: If outside temperature -43˚C
than room temperature has to be 16˚C or above
-18 -7 4 16
-29
A
B
Room Temperature (˚C)
Outside Temperature (˚C)
-32
-34
-37
-40
-43
Operating Range
RIGHT WRONG
GAS
PARAFFIN
PARAFFIN
Danger
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 3
3
The FF 55T is designed for use with Paraffin. Use of low-quality fuel will cause burner performance to drop, leading to abnormal combustion and reduced heater life.
Purchase only Paraffin, in non-red cans reserved exclusively for fuel and marked accordingly with the word “PARAFFIN”. Always store your fuel in a separate area from where you store gasoline for your power equipment to avoid accidental use of gasoline in your heater.
What to Buy . . .
ALWAYS: Clean and high-quality Paraffin. ALWAYS: Fuel free of contaminants, water or cloudiness. NEVER: Gasoline, alcohol, white gas, camp stove fuel or additives. NEVER: Yellow or sour-smelling fuel.
How to Store It . . .
ALWAYS: Store in a clean container, clearly marked PARAFFIN. ALWAYS:
Store away from direct sunlight, heat sources or extreme temperature
changes. NEVER: In a glass container, or one that has been used for other fuels. NEVER: For longer than six months. Begin each heating season with
fresh fuel; discard at the end of season. NEVER: In the living space.
Why It is Important . . .
Pure, clean fuel is essential for safe and efficient heater operation. Poor quality or contaminated fuel can cause:
Excess tar deposits on burner and flue pipe
Incomplete combustion
Reduced heater life
Use of a highly volatile flammable fuel such as gasoline can produce uncontrolla­ble flames, creating a severe fire hazard.
SECTION C: FUEL GUIDE
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 4
4
5. POWER SAVER/DAY SELECT button
3. TIMER button
9. AUTO indicator
10. TIMER indicator
11. POWER SAVER indicator
12. CHILD LOCK indicator
4. TEMP/TIMER/CLOCK/DAY set
15. SUN MON TUE WED THU FRI SAT indicator
7. ˚F/˚C toggle switch
6. CHILD LOCK/CLEAR button
2. AUTO button
1. ON/OFF switch
8. ON lamp
13. BURNING MODE indicator
14. ˚F/˚C indicator
Before using heater, familiarize yourself with the following operating controls and part names.
Outlet opening
Inlet opening
Ciraulation air filter
16. Circulation fan
Pipe stopper
18. Power supply cord
Control panel
Front panel
Combustion flames peep hole
Drip tray
Louver
17. Room temperature sensor
SECTION D: OPERATING CONTROLS AND PART NAMES
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 5
5
Main switch turns heater on and off. When switched on, heater begins operation and combustion starts after preheat period.
The button turns weekly timer operation modes on and off which have been programmed into weekly timer.
The button turns weekly timer set mode on and off.
TEMP/TIMER/CLOCK/DAY set modes can be set by pressing the /MIN. or /HOUR buttons.
The button turns POWER SAVER operation mode on and off. When setting weekly timer, the button is used to select a day of the week.
The button turns CHILD LOCK operation mode on and off. When setting weekly timer, the CLEAR button is used.
˚F/˚C toggle switch.
Lit – Heater is in operation. Flashing – Pre-heating and pre-purging.
Lit – Weekly timer operation is in use.
Lit – Heater operating in weekly timer set mode.
Lit – Heater operation in POWER SAVER mode.
Lit – Heater operation in CHILD LOCK mode.
Lit – Heater operation at high, medium or low combustion.
Lit – Digital indicator shows current temp. Flashing – Current temp can be changed.
Lit – Digital indicator shows current day or timer day.
Three speed motor supplies high-capacity warm air flow during high combustion for heating room up quickly, and low or medium-capacity warm air flow during low or medium combustion for maintaining comfortable room temperature.
Constantly senses room temperature and supplies information to heater so that desired room temperature can be maintained. The position of room temperature sensor can be changed by using the extension wire (*optional) (See Page 26.)
For use in 220V AC, 50Hz electrical outlet.
1. ON/OFF switch:
2. AUTO button:
3. TIMER button:
4. TEMP/TIMER/CLOCK/DAY set:
5. POWER SAVER/DAY SELECT button:
6. CHILD LOCK/CLEAR button:
7. ˚F/˚C switch:
8. ON lamp:
9. AUTO indicator:
10. TIMER indicator:
11. POWER SAVER indicator:
12. CHILD LOCK indicator:
13. BURNING MODE indicator:
14. ˚F/˚C indicator:
15. SUN MON TUE WED THU FRI SAT indicator:
16. Circulation fan:
17. Room temperature sensor:
18. Power supply cord:
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 6
6
BEFORE IGNITION
1: Filling Fuel
• Do not fill the removable tank in the living room, but in a more suitable place (there can always be some spillage).
• Do not refuel the heater while in operation or still hot.
Follow the procedure below:
1) Make sure that the heater is switched off.
2) Open the tank lid and lift the removable tank out of the heater. NOTE: Some drops may leak from the tank. Put down the removable tank (cap pointing
upwards) and screw off the fuel cap.
3) Take the manual fuel pump and insert the smooth, most rigid tube into the can. Make sure that it is in a higher position than the removable tank. Insert the ribbed hose into the opening of the removable tank.
4) Lock the switch button on top of the pump (turn clockwise).
5) Squeeze the pump a few times, until fuel starts flowing into the removable tank. As soon as this happens, there is no need to press any longer.
6) Check the removable tank fuel gauge while filling the tank. Stop filling by loosening the switch button on top of the pump (turn anti-clockwise), once the gauge indicates that the tank is full. Never overfill the tank, especially not when the fuel is very cold (fuel expands when it heats up).
7) Let the remaining fuel in the pump flow back into the can and carefully remove the pump. Carefully screw the fuel cap back on the tank. Clean off any spilled fuel.
8) Check whether the fuel cap is straight an tightened properly. Reinstall the removable tank in the heater (cap down). Close the tank lid.
2: Connect in the heater
Connect heater into a 220V AC, 50Hz electrical outlet. On digital indicator pre-set “Two Dashes” will be showing. NOTE: Do not connect to an outlet
shared with other appliances.
3. Set Clock
IMPORTANT: Clock on the heater must always be set to current time and day.
NOTE: The “MIN.” or “HOUR” button will change the time every one (1) unit. Holding the button continuously
will cause the time to change rapidly.
NOTE: In the event of a power failure (more than approx. 30 min.), all clock and day may be cancelled.
SECTION E: OPERATION
empty full
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 7
7
4. Setting of the Time and a Day of the Week.
1) Current time is not set yet. (All signs light.)
Press the “MIN.” button or “HOUR” button while in not operation. (Power switch is off.) 0:00 (midnight) is indicated on the display. (All signs except the colon are blinking.)
2) Setting of the current time
Press the “MIN.” button to set minutes and press the “HOUR” button to set hours. When pressing the “HOUR” button, the sign will change as follows. “0:00” “1:00” ··· “11:00” “12:00” “13:00” ··· “23:00” “0:00” ··· When pressing the “MIN.” button, the sign will change as follows. “0:00” “0:01” ··· “0:59” “0:00” ··· Press the “SET” button to complete the set of the current time.
3) Setting of a day of the week
“dAy” sign is shown on the display and all of a day of the week blink. Press the “MIN.” button or the “HOUR” button to set a day of the week. A day of the week will blink. (Initial setting is “SUN”.) The other days of the week will go off. Select a day of the week by using the “MIN.” or the “HOUR” button. When pressing the “MIN.” button, the sign will change as follows. “SUN” “MON” “TUE” “WED” “THU” “FRI” “SAT” When pressing the “MIN.” button at the position of “SAT”, you can hear the beep sound and “SAT” is not changed any more. When pressing the “HOUR” button, the sign will change as follows. “SAT” “FRI” “THU” “WED” “TUE” “MON” “SUN” When pressing the “HOUR” button at the position of “SUN”, you can hear the beep sound and “SUN” is not changed any more. Press the “SET” button to complete the set of a day of the week. The current time and a day of the week will show on the display.
NOTE: If the ON/OFF switch is pressed during resetting of the current time and a day of the week after setting
the time and a day of the week, the set mode of the current time will terminate and the operation will start. If a day of the week is set, the time is fixed at the resetting time. If a day of the week is not set, the contents of the setting are deleted.
FF_55T_Type B_US.qxd 14.5.29 15:58 ページ 8