Totally wicked Skope S User Manual

USER MANUAL
CONGRATULATIONS ON PURCHASING YOUR TOTALLY WICKED SKOPE S ELECTRONIC CIGARETTE KIT
QUICK START GUIDE
For those familiar with e-cigarettes, the steps below can be followed to allow the device to be used in the shortest possible time:
• Prime the atomizer head
• Fill the tank
• Switch the Skope S on
• Press the power button and inhale
Charging Port
USING YOUR SKOPE S
Priming the Atomizer Head
Note: It is important to “prime” a new atomizer head before rst use. Failure to do so
can cause the atomizer coil to overheat, leading to an unpleasant taste and sometimes
irreversible damage to the atomizer head requiring early replacement.
To prime the atomizer head, remove the mouthpiece from the tank by unscrewing, then
remove the glass section of the tank by pulling upwards. Unscrew the atomizer head and
prime by dripping a few drops of e-liquid onto the cotton visible through the sides of the
atomizer. After priming, screw the atomizer head back into place, replace the glass section and screw the mouthpiece back on.
Note: Leave a new
atomizer head to sit with the tank full of e-liquid
for ve minutes before vaping. This ensures the
atomizer head is fully saturated with e-liquid
before use.
Skope S Tank
Power Button
Skope S Battery
Filling the Tank
Remove the mouthpiece from the tank by unscrewing. Fill the tank with e-liquid, being careful not to overll and avoid lling down the central airow hole. Once lled, ret the mouthpiece.
Powering On and O:
To switch on, quickly press the power button ve times; the indicator light will ash three times. Quickly press the power button ve times to turn the battery o; the indicator light will ash three times.
Vaping:
Press and hold the power button as you inhale the vapour.
E-liquid Level:
To prevent the atomizer head from becoming dry and burning prematurely,
ensure the uid level does not drop below the uid feed holes on the atomizer, these
can be recognised by the visible parts of
cotton on the atomizer.
Charging the Battery:
The Skope S is charged by inserting the
USB cable into the charging port. The
indicator light will illuminate red while
charging. Once fully charged, the red indicator light will switch o.
Replacing the Atomizer Head:
To replace the atomizer head, follow the steps outlined in Priming the Atomizer
Head to remove and separate the tank.
Prime your new atomizer head and
reassemble.
PROTECTIONS
Short Circuit Protection:
If an atomizer short circuit occurs, the
indicator light will ash three times and the Skope S will switch o. Replace the
atomizer head and charge the battery to restore power to allow normal operation
to resume.
No Atomizer Detected:
If no atomizer head is detected when the power button is pressed, the indicator
light will ash continuously until the power button is released. If this happens, ensure the atomizer head is properly tted,
referring to appropriate instructions
above.
Atomizer Head Protection:
If the power button is held down for longer than 15 seconds while vaping, the
indicator light will ash eight times and the Skope S will switch o. Release the
power button and charge the battery to restore power and allow normal operation
to resume.
Kit contents:
1 x Totally Wicked Skope S
2 x BFHN 0.5ohm atomizer heads
3 x Silicone rings
1 x USB cable 1 x User manual
Manufactured in China under the authority
of Pillbox38 UK Ltd, Stanclie Street, Blackburn, Lancashire, BB2 2QR.
Specications:
Dimensions: 14.0mm (diameter) x
113.0mm (length)
Weight: 38g
Battery capacity: 650mAh integrated battery. Output modes: Constant voltage Max charging current: 1.0A Max output voltage: 1.85V Tank/Battery connection: All in one/ Proprietary connection. Tank capacity: 1.2ml Filling method: Screw top ll Airow type: Non-adjustable Max rell nozzle diameter: 2.8mm
ADDITIONAL PRODUCT INFORMATION
There are no reported medical side eects with this product. If you believe you experience a side eect, please contact the manufacturer.
PRODUCT STORAGE AND BATTERY PRECAUTIONS
• Store the Skope S and its accessories
away from children when not in use.
• Please only use the charging cable
provided.
• Please dispose of dead batteries in accordance with your country’s
appropriate legislation.
• Do not charge the battery in a damp environment, or in temperatures under
0°C or above 45°C.
• Do not use the device in temperatures
under -10°C or above 60°C.
• Do not carry batteries in a pocket or bag
with other metallic objects.
• Do not attempt to repair a faulty Skope S battery as these are sealed units with no
serviceable parts. Attempted repairs will void the warranty.
WARRANTY
The Skope S components have a 28 day parts warranty, with the exception of atomizer heads, which are consumable items and covered by “dead on arrival”
warranty only. The USB cable supplied has a 12-month warranty. If any parts are
found to be faulty within this time please contact our customer service team, whose details are below and we will arrange for a
replacement. We may require the goods to be returned for further investigation.
Tel 01254 692244 www.totallywicked.co.uk Tel 1(888) 761-9425 www.totallywicked.com Tel 0941-78447082 www.totallywicked.de
Loading...