Toshiba TS, TX User Manual

Smooth Stepless Starting and Stopping
Reduces Motor Inrush Current
Eliminates Line Voltage Drops During Starting
TS/TD/TX Series
Solid State Starters
Reduces Wear and Mechanical Shock
Eliminates Water Hammer
RELIABLE AND TOUGH
ANALOG (TS Series) & DIGITAL (TD & TX Series) MODELS
REDUCED VOLTAGE STARTERS - 1 to 1125HP
HEAVY DUTY DESIGN - 500% starting current for 60 seconds.
CURRENT LIMIT & VOLTAGE RAMP - Combines both
to offer the best starting method for any application.
to close slowly, eliminating water hammer.
Standard Features
Soft Start - Voltage Ramp/Current Limit Soft Stop - Decel/Pump Control Current Ratings: 6 - 1250A Voltage Ratings: 208 - 600V Continuous Rating - 125% Overload Capacity - 500% for 60 seconds Overload Capacity - 600% for 30 seconds 120Vac Control Voltage (240Vac Optional) UL & cUL Listed
Protective Features
TS Series (6 - 32A): Overtemperature & Overload TD Series (48 - 1250A): Overtemperature, Electronic
Overload (Class 5 - 30), Undercurrent (10 - 90% of motor FLA), Shorted Load, Shorted SCR (Shunt trip ­separate trip relay), Overcurrent (50 - 300% of motor FLA), Phase Loss/Imbalance (5 - 30%), Repetitive Starting TX Series (48 - 1250A): Overtemperature, Electronic Overload (Class 5 - 30), Undercurrent (10 - 90% of motor FLA), Shorted Load, Shorted SCR (Shunt trip ­separate trip relay), Overcurrent (50 - 300% of motor FLA), Line Frequency, Phase Loss, Current Imbalance (5 - 30%), Phase Reversal, Repetitive Starting, Ground Fault, Overvoltage, Undervoltage, and optional Stator & Bearing RTD inputs
Adjustments
TS Series:
Voltage Ramp Start (0 - 60 seconds) Initial Voltage Adjustment (0 - 80%) Current Limit Start (200 - 500%) Soft Stop - Adjustable Deceleration (0 - 30 sec.) Stop Voltage Adjustment (0 - 100%)
TD & TX Series:
Voltage Ramp Start (1 - 120 seconds) Initial Voltage Adjustment (0 - 100%) Current Limit Start (200 - 600%) Soft Stop - Adjustable Deceleration (1 - 60 sec.) Stop Voltage Adjustment (0 - 100%) Beginning Decel Voltage Level (0 - 100%) Voltage Jog (5-100% Voltage, 1 - 20 sec.) Current Jog (100 - 500%) Kick Start (10 - 100% Voltage, 0.1 - 2 sec.) Starts per Hour (1 - 10 Starts/hr, 1 - 60 min. between start attempts) Coast Down Lockout Timer (1 - 60 min.) Overload Reset (Manual or Automatic)
Metering/Communications
TD Series:
Phase Currents, Remaining Thermal Capacity, Elapsed Time (ETM), Run Counter, Fault Codes, Fault History, Lockout Time Remaining, Real Time Clock. Communications: Modbus RTU, RS485
TX Series:
Phase Currents (A, B, C), Ground Current, Avg. Current, Unbalance %, RPM, Line Freq., Power Factor, kVAR, kW, kVA, kW Demand, kVAR Demand, kWH, Remaining Thermal Capacity, Required Thermal Capacity to Start, RTD Data (12 RTDs), Elapsed Time (ETM), Run Counter, Fault History, Lockout Time Remaining, Real Time Clock, plus more. Communications: Modbus RTU, RS485 or RS422
Printed in U.S.A. Copyright 5-2001 PAC - TXSSS - 10/03SE
Status Indicators
Control "Power On" Full Voltage "At Speed" Shunt Trip Shorted SCR Over Current Phase Loss Over Temperature Overload
Digital TD Series Operator Interface Panel with 4 Digit Display & 8 Function Keys
TX Series Operator Interface Panel with LCD Display (2 Lines x 20 characters), 8 Function Keys, 12 LED Status Indicators
Available Options
Construction - Open chassis type or enclosed (Type 1, 12,
3R, 4 & 4X). Non-combination or Combination (with circuit breaker, fusible or non-fusible disconnect switch).
Bypass - Air and Vacuum bypass contactors are available. Electronic DC Injection Braking
TOSHIBA