PART I ............................................................................................................................................... 33
PART II .......................................•..................................................................................................... 35
PART III ............................................................................................................................................. 38
PART IV............................................................................................................................................. 41
PART VI............................................................................................................................................. 43
PART VII............................................................................................................................................ 44
PART VIII......................................................................................................................................... 45
PART IX............................................................................................................................................. 46
PART XI............................................................................................................................................. 49
We thank you very much for purchasing our TEC Electronic SL59 Series Scale.
This series has been desingned with TEC reliability and offer a cost efficient system for a modest invest
ment.
And the SL59 (with thermal printer) takes advantage of the latest technology in microprocessors. Because
of this, the decreased cabinet size permits the system to be placed virtually anywhere in your store.
Your deli, and specialty departments can enjoy these high quality reliable TEC products. Improve your
operating effectiveness and watch the increased utilization of your front end scanning investment. This
electronic Load cell scale eliminates all moving parts and furnishes an accurate digital display of all infor
mation.
We believe that your needs will now be fully satisfied, and you will have total reliability in price calculation.
This manual will help to acquaint you with the proper operation and care of the SL59 series scale. Please
keep it handy for future reference.
PRECAUTIONS
1. DONT SUBJECT the weighing platter to SUDDEN SHOCKS.
2. DONT DEPRESS THE KEYS TOO HARD. Keys will operate correctly if they are merely touched lightly.
3. Clean the cover and weighing platter by wiping with a dry cloth or a cloth soaked with detergent and
wring out thoroughly. NEVER USE THINNER OR OTHER VOLATILE SOLVENT FOR CLEANING.
4. This machine has been made drip-proof, but DO NOT POUR WATER directly on it.
5. To insure scale is operating correctly, place a known weight on platter and check for correct computing.
This should be done every morning before starting normal operations.
6. When in use, avoid locations subject to vibration and direct sunlight.
- 2 -
1. SPECIFICATION
El-04189
Items
SL59-15L-US-1
SL59-30L-US-1 ,
Max. Capacity15lbs30lbs
Minmum Scale Division
Display Range
Unit Price Presettable
Tare
0.0051b
0~ 15.0251b0-30.051b
$0.01 -99.99Same as SL59-1 5L
0.0051b ~ 9.9951b0.01 lb-30.001b
0.011b
Remote Display:
Weight5 digits
Unit Price4 digits
Total Price5 digits
4 digits
4 digits
5 digits
Capacity of PLU memory102 - 290 PLUs (Standard type)
(It depends on each PLU capacity.)
Same as SL59-15L
Display DesignationsNET, PREPACK, ERRORSame as SL59-15L
Remote Display Mode
Minimum Price Display
Both sides
$0.01
Same as SL59-15L
Same as SL59-15L
Mechanical:
Printer Head
Paper Feeding
Mechanism
Paper End Detector
Power Requirement1 20V ± 10%, 60Hz
Power Consumed120V-1A
Temperature Limits
Relative Humidity
Weight
Thermal Printer Head
Stepping Motor
Same as SL59-1 5L
Same as SL59-15L
Micro SwitchSame as SL59-1 5L
Same as SL59-1 5L
Same as SL59-15L
32*~ 104T
45% - 85%
26.5lbs
Same as SL59-15L
Same as SL59-1 5L
Same as SL59-1 5L
Same as SL59-15L
Same as SL59-1 5L
Same as SL59-1 5L
Dimensions (approximate)
(Inch)
4.3"
3 -
2. OVERVIEW
Et-04189
Remote Display
3. REMOTE DISPLAY
- 4 -
4. KEY ARRANGEMENT
5. KEY AND LAMP FUNCTIONS
Name of Key & Lamp
Lab
el 1 iessue
Moc
Lab
Moc
Switch (1)
el 1
ssue
Je
Switch (2)
AUTO
MANUAL
-WEIGH
-FIX PRICE
- BY COUNT
"AUTO" position:
This position is used to issue regular scale labels.
When the weight becomes stable, the label will automatically be issued,
"MANUAL" position:
When the weight becomes stable, the label will be issued by depressing
0 Key.
"WEIGH" position:
This position is used in weighing function of SL59.
"BY COUNT" position:
It is possible to produce labels which contain information of quantity
pricing, instead of weight.
"FIX PRICE" position:
The Unit Prince enters directly to Total Price on calling up PLU, and that
Total Price cannot be changed by any weighing after that.
Functions
^ERIC
NUf
0
CLEAR Key
<eys
C
9
These keys are used to enter PLU Number, Unit Price and Tare weight.
1. This key is used for enter-clear of numeric key.
2. This key is used to return the machine condition to the normal weigh
ing mode. '
3. This key is used to release the scale from the SAVE mode.
- 5 -
El-04189
Name of Key & Lamp
TARE Key
T
SAVE Key
SAVE
DATE & TIN lEKe
OAT^
^flME
FOR Key
FOR
FEED Key
FEED
Functions
This key is used to subtract tare weight.
1. This key is used to save tare and unit price after taking off the com
modity from a platter.
2. This key is used for CMT operation.
3. This key is used for adjustment of label spacing.
y
1. This key is used to indicate the time and date on remote display.
2. This key is used to change the date.
1. For issuing "By count" label with split price
2. In "X", "Z" control lock positions, this key is used to generate PLU
Group or Random Items Total Report.
3. For issuing TEST label at "PRI" control key position.
These keys are used to set and call the PLU numbers of frequently used
33
articles.
This key Is used to cancel only one article's data by depressing this key
after its registration.
1. This key is used to select a PLU number.
2. This key is used for returning to initial mode.
1. For issuing Total labels.
2. In case of Label issue mode switch setting at MANUAL position, this
key has the function of label issue.
These keys are used to calculate the unit price by 1/2lb or 1 /41b.
This key is used to adjust ZERO point.
NET Lamp \l/
PREPACK Lamp si/
ERROR Lamp \l/
-T-
-T-
Lights when tare is subtracted.
Lights when SAVE key is depressed. ,
Lights when this machine is improperly operated or has caused a func
tion error.
6 -
6. MAIN CONTROL LOCK
The control lock has eight marked positions.
There are four control keys which will operate these locks, these are:
This key (OP) will access the
REG and OFF positions.
This key (MAI) will access the
PR2, PR1, REG, OFF and X po
sitions.
This key (MA2) will access the
PR2, PR1, REG, OFF, X and Z
positions.
El-04^89
PR2
PR1
REG
OFF
X
(RAM CLEAR)
This key (SE) will access all
eight positions.
(SE key may be kept with your
TEC representative for servic
ing.)
Date, time, machine No., store code, store address. Bar Code Format, and PLU can be pro
grammed.
PLU unit price, direct key and Spacing of a label etc. can be programmed or changed.
Machine can be used as a scale and register the data on a label.
Machine is locked and any further key entry is impossible.
Day-Total etc. can be read out and printed out on the paper or label.
The data-memory is not reset to zero. '
Day-Total etc. can be printed out on the paper or label and the data-memory is reset to zero.
-------
Used to clear all memories (all Total and PLU file).
(Depress Key).
(TEST)
---------
;—- Used to indicate all test status in displays.
7 -
7. ALPHA KEYBOARD (OPTION)
ALPHA KEYBOARD
(RK-3-1)
The SL59 system has the capability to be interfaced with a separate alpha key
board. This typewriter format keyboard greatly enhances the system by allowing
the programming of alpha descriptors for PLU's or Commodities. All price pro
gramming can be done through the 57 keys alpha keyboard including pricing by
1 /2 pound and 1 /4 pound.
•xysp OELETE aEAH QT/TM SRM6 SETURW OflTR 1*- /
□ □□□□□□□□□□□
I 2 3 * 5 6 7 i » 0 , T
□ □□□□linniziciinn
a W E R T fU
□□□□□□□□□□□□
A s 0 ea H JK lv. ’A 'A
□□□□□□□□□□□a
Z X C V B N W SPACE f
□ □□□cijizinnDnnn
(Option)
________
I 0 P It &
_____________________________________ __________
ei-04l89
___________
ALPHA KEYBOARD
The alpha keyboard is used with the MA1 or MA2 key at the control lock PR2, position.
NUMERIC KEYS
ALPHA KEYS
SPECIAL
CHARACTER KEYS
CZlDII[ZI[Z]
DATE/TIME KEY
DT/TM
BACK SPACE kEY
BK/SP
The numeric keys are number keys 0-9.
PLU number, unit price and store code etc. can be indexed on this keyboard in
stead of using the operation panel.
The alpha keys include the entire English alphabet. These keys are arranged in
the standard typewriter format for easy data input.
Twelve additional keys are provided to increase the read-ability of descriptors
.
T
This key allows the correct programming of the calendar date and international
time. Once this has been set, the Time of Day clock within the SL59 correctly
maintains the time and automatically advances the date.
The BK/SP key can be used to retreat to a prior entry in descriptor program
ming and make a correction.
#
&
1 %
V2I [TJ^
/
8 -
El-04189
RETURN KEY
RETURN
DELETE KEY
DELETE
GRADE KEY
GRADE
ENTER KEY
ENTER
CLEAR KEY
CLEAR
VERIFY KEY
(Inch)
The programming of a two line descriptor can be performed by depressing the
RETURN key which returns the carriage.
When a PLU is no longer to be maintained in the PLU file the DELETE key is
used to remove the PLU.
The GRADE key is not used in the SL59 system.
During programming, data is input to the SL59 system by using the ENTER
key.
The function of the CLEAR key on the alpha keyboard is identical to the same
key on the operation panel. This key allows the clearing of numeric entries prior
to the depression of another function key.
Used to print mark as special character.
When the control lock is at the PR2 position, this remote key unit (RK-3) is used to preset the DATA of the
PLU, etc. ’
- 9
8. CASSETTE MAGNETIC TAPE OPERATIONS
The SL59 is designed to interface with a cassette magnetic tape. This tape unit allows the transfer of the
entire PLU file from the SL59 to the tape. This can be accomplished using a number of operation steps. In
turn, information from the tape can also be transferred to other SL59.
1) SAVE(SL59 - CMT)
Control lock: PR1 position
j Start the tape to be recorded after entire rewinding.
Index I 1 I
Confirm the magnetic painted part of tape running the Head.
(Over 5 sec. after Starting.)
Depress:SAVE key
2) SAVE Comparison
Rewind the tape entirely again.
Start the CMT to play (Not recording).
El'04189
Index I 2 I
I
Depress:
3) Load (CMT - SL59)
Depress:
4) Load Comparison
Same procedures as "SAVE comparison".
5) Errors
Comparison Error (-4):
Header Error (-2):
Time Over Error (-3):
Hard Error (-1):
SAVE key
Start the CMT to play (Not recording).
Index I 3 j
SAVE key
Warning for being different points after comparison.
Warning for the use of another Spec. Tape. '
Warning for being over time (14 seconds) after depressing ! SAVE
key in Load and Comparison (Not save operation).
Warning for the status Error.
NOTE 1: The error mode can be released by depressing [ C | key, and try to operate again according to
the above steps.
2: When SAVE operation (SL59 CMT) cannot be executed in 4 seconds after depressing
SAVE key, it will result in Time over error mode.
- 10 -
9. LEVEL ADJLUSTMENT
E1-041B9
Set the scale on a stable and level surface.
Level the scale by turing the adjustable legs so that the air bubble is
inside the center circle.
When the air bubble moves toward the left side,
turn the right adjustable legs clockwise.
When the air bubble moves toward rear,
turn the front adjustable legs clockwise.
Correct
Level Gauge
Incorrect
10.NOTES BEFORE STARTING .OPERATION
(1) Be sure to insert the power plug into AC outlet.
(2) When the power plug is connected to the AC outlet, thè scale goes through the test scanning
sequence, such as 00000,00000,000000, then 11111, 11111, 111111 •■■and zeros appear on the
weight and total price displays. When the control lock is turned from OFF to REG over 16 seconds
after the power plug is connected to the AC outlet, all “8”s appear on all displayd, there by
completing the test scanning sequence.
(3) While scale is in the test sequence, do not put anything on the platter.
(4) Do not move the unit while it is in operation. Should it become necessary ot move it at any time, turn
the control lock to OFF poosition and be sure to redjust the level indicator after relocating the scale.
(5) Should a power failure occur during operation, remove the commodity from the platter and insert the
power plug into AC outlet again when power is restored.
(6) If scale is used with an unrated power source, inaccurate scaling or other errors may occur.
(7) If Zero Point has shifted during scaling, and no tare is displayed, adjust Zero Point by depressing
Zero switch.
11 -
11. OPERATING SECTION
El-04189
- 13 -
11-1 NORMAL OPERATION
A. Weighed Article Registration
Control lock: req
Example:
In case of a commodity of
which PLU # 1501 and a unit
price of $25.00/lb are pro
grammed in direct key QH
Label issue mode SW.:
In case of a commodity of
which unit price of $25.00/lb
is programmed for PLU #
1501.
El-04189
-WEIGH
- FIX PRICE
- BY COUNT
In case of a commodity with a
unit price of $25.00/lb.
(Random Items PLU)
(Optional function by Dip
switch)
(Direct key)
PRICE/lb
25.00
Place the Tare on.
PREPACK
\ I/
"T- __
(Unit Price and Tare are fixed.)
SAVE
Place a article on.
(0.151b)
Depress:
(3.50 lb)
1
0
5
1
PLU
“Г
PLU
PRICE/lb
25.00
WEIGHT PRICE/lb
0.15
0.00
3.5025.00
25.00
25.000.00
г 1.
----------------
PRICE/lb
25.00
■
TOTAL
PRICE
3.75
87.50
AUTO
MANUAL
•Depress
Intial mode
: AUTO
1
u
The label is issued.
BE EF
PACKED ON
MAR 18
SELL BY
0“2
20
N6T
987503
THANK УПИ
19250 VAH HESS AVE. CALIF.
PLU
key when initial mode is desired to be returned.
WEIGHT
0.00
MAR 25
(Sample labels)
PRICE/lbTOTAL PRICE
AUTO
1
MANUAL :
PRT/.
]
Ш
MANUAL
T
The label is issued.
OT HE R S
PACKED ON
MAR 18
SELL BY
0 "21 9
19250 VAN mss AVE. CALIF.
p
82“987508'
0000
Random
Items
Label
- 15
B. Non Weighed Article Registration
Control lock;
1) BY COUNT (1)
WEIGHT display:
Example:
In the event that PLU # 1503
and a unit price of $4.70/lb are
programmed in Direct key Q .
PRICE/lb
4.70
Quantity of purchase.
(Can be ommitted.)
Max. 2 digits.
Label issue mode SW:
In the event that a unit price of
$4.70/lb is programmed for
PLU # 1 503.
150
3
i
PLU
FOR
PRICE/Ib
4.70
1
-WEIGH
-FIX PRICE
- BY COUNT
in the event of a unit price of
$4.70.
(Random Items PLU)
(Optional function by Dip
switch)
PLU
T. PRICE
(Random
PRICE/lb T. PRICE Items PLU)
124.70
P 124.70
0.00
0.00
AUTO
: AUTO
MANUAL
The label is issued in succession
after peeling it.
,r
0
0"5008
NET WTCja I PBCE/it)gai i tot/u.pngr°
19250 VAN NESS AVE. CALIF.
000004
THANK YOU
R№
PRT/.
RACKED ON
MAR 18
SELL BY
MAR 28
12 PIECES $4._7[
Random Items PLU
^ ’
NET WT (EH I PRirF/lt) TJ I TdTAL ^
' Depress:
P 12
MANUAL:
Single label is issued.
1
4.70
(Random Items PLU)
OT HE R S
PACKED ON
MAR 18
SELL BY
0"1 9
827"000004
12 PIECES _
THANK YO
19250 VAN NESS AVE. CALIF.
]
4.70
AUTO
MANUAL
(Sample labels)
- 16 -
2) BY COUNT (2): Split price procedures-1
Example: In case of purchasing 17 pcs. of article for $4.70 of unit price for 8 pcs.
El-04189
Quantity of purchase.
(Can be ommitted.)
Max. 2 digits.
Quantity for that unit price.
(Can be omitted.)
Max. 2 digits.
(Direct key)
PRICE/lb
4.70
FOR
I
FOR
15
8
PI II
03
PRICE/lb
4.70
PRICE/lb
17
P 17
84.70
P 84.70
T. PRICE
4.70
4.70
AUTO
MANUAL
: AUTO
f
The label is issued in succession
after peeling it.
0R№
0 "500S 0
THANK YOU
19250 VAN NESS AVE. CALIF.
(Sample labels)
1
PRT/.
PACKED ON
MAR 18
SELL BY
000004 MAR 28
PIECES
$J.9917
P 17
MANUAL
Ì
Single label is issued.
9.99
AUTO
MANUAL
17 -
Loading...
+ 35 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.