Toshiba RAS-24UFHP-E, RAS-24UAH-E user guide manual

ACCESSORIES AIR FILTER COMPONENTS
Remote control Remote control
holder
Batteries (two)
Filter frames (two)
ENGLISH
PRECAUTIONS FOR SAFETY
DANGER
DO NOT ATTEMPT TO INSTALL THIS UNIT BY YOURSELF. THIS UNIT REQUIRES QUALIFIED INSTALLER.
DO NOT ATTEMPT TO REPAIR THE UNIT BY YOURSELF. THIS UNIT HAS NO COMPONENTS WHICH YOU CAN REPAIR.
OPENING OR REMOVING THE COVER WILL EXPOSE YOU TO DANGEROUS VOLTAGES.
TURNING OFF THE POWER SUPPLY WILL NOT PREVENT POTENTIAL ELECTRIC SHOCK.
WARNING
WARNING ABOUT INSTALLATION
Make sure to ask a dealer or a store specialized in electric work to install the air conditioner. If the air conditioner is imperfectly installed by yourself, it may cause some problems such as water leak, electric shock, fire, and so on.
Ground the air conditioner without fail. Do not connect the ground wire to gas pipe, water pipe, lightning rod or ground wire of telephone. If the air conditioner is imperfectly grounded, it may cause electric shock.
Zeolite filter Purifying filter
CAUTION
TO DISCONNECT THE APPLIANCE FROM THE MAIN POWER SUPPLY This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm.
WARNING ABOUT OPERATION
Avoid cooling the room too strong or exposing the human body to cool wind for a long time, because it is bad for the health.
Do not insert fingers and sticks into the air outlet and air inlet to avoid getting injured and damaging the machine, because there are fans running at a high speed inside both the air inlet and air outlet.
When you are aware of something abnormal with the air conditioner (smells something scorching, cools weak, etc.), immediately turn off the main switch, the circuit breaker, from the main power supply to stop the air conditioner, and make contact with the dealer. If the air conditioner is continuously operated with something abnormal, it may cause machine failure, electric shock, fire, and so on.
Do not spill water or other liquid on the indoor unit. If the unit is wet, it may cause an electric shock.
WARNING ABOUT MOVEMENT AND REPAIR
Do not move nor repair any unit by yourself. Since there is high voltage inside the unit, you may get an electric shock when removing the cover and main unit.
When moving the air conditioner for re-installing in another place, ask the dealer to do it. If it is imperfectly installed, it may cause electric shock or fire.
EN
1
CAUTION
CAUTIONS ABOUT INSTALLATION
Certainly lay the drain hose for perfect draining. Wrong drainage may cause flooding in the house and getting furniture wet.
Make sure to connect the air conditioner to an exclusive power supply of the rated voltage; otherwise, the unit may break down or cause a fire.
Do not install the unit in a place where inflammable gas may leak. If inflammable gas accumulates around the unit, it may cause a fire.
CAUTIONS ABOUT OPERATION
Carefully read this manual before starting the air conditioner. The manual includes many important things for daily operation.
Do not use this air conditioner for other purposes such as preserving food, precision instruments, art objects, breeding animals, growing potted plants, etc. Do not install this air conditioner in a special-purpose room such as a ship or any kind of vehicle, otherwise it deteriorates the machine performance.
Avoid exposing potted plants and animals to wind of the air conditioner, because it badly affects the health and growing of them.
When the air conditioner is operated together with a combustion appliance in the same place, be careful of ventilation to let fresh air into the room. Poor ventilation causes oxygen shortage.
When the air conditioner is used in a closed room, be careful of sufficient ventilation of the room. Poor ventilation causes oxygen shortage.
Do not touch operation button with wet finger; otherwise, you may get an electric shock.
Do not place any combustion appliance in a place where it is directly exposed to wind of the air conditioner; otherwise, it may cause imperfect combustion.
When the air conditioner won’t be used for a considerably long time, turn off the main switch or the circuit breaker, for safety. Disconnection from the power supply prevents the unit from lightning and power source surge.
Do not put a vessel with water such as a vase on the unit, because water may possibly sink into the unit and will bring about electric shock because of deterioration in electric insulation.
Check the concrete blocks, etc. underneath the outdoor unit occasionally. If the base is left damaged or deteriorated, the unit may topple over and inflict an injury on a person as the worst case.
Do not wash the unit with water. It may cause an electric shock.
Do not use alcohol, benzene, thinner, glass cleaner, polishing powder, etc. for
cleaning the unit, because they deteriorate or damage the air conditioner.
When cleaning the unit, make sure to turn off the main switch or circuit breaker beforehand for preventing you from getting injured by the electric fan running inside. For details of cleaning method, refer to “Maintenance” on page 17 and 18.
Do not put anything on the outdoor unit nor step onto it. If you do so, it may not only topple over the unit but also injure yourself.
To make the air conditioner demonstrate its original performance, operate it within the range of the operating temperature specified in the instructions. Otherwise it may malfunction, break down or water may leak from the unit.
ENGLISH
2
1
3
2
PARTS NAME
PRE.DFILTERHi POWER
Outdoor unit
11
1 Drain hose, refrigerant connecting pipe and
11
electric wires
22
2 Air inlet (Side and rear)
22 33
3 Air outlet
33
Indoor unit
44
4 Room temperature sensor
44 55
5 Front panel
55 66
6 Air inlet grille
66 77
7 Air filter
77 88
8 Air outlet
88 99
9 Horizontal air flow louver
99 !!
! Vertical air flow louver
!! ""
" Display panel
"" ##
# Infrared signal receiver
## $$
$ Remote control
$$
2
1
3
(24 class)(18 class)
5
8
10
13
12
11
9
7
4
6
NAMES AND FUNCTIONS OF INDICATORS AND CONTR OLS ON INDOOR UNIT
Display panel
The operating conditions are indicated below.
11
1 TEMPORARY button
11 22
2 Hi POWER lamp (Green)
22 33
3 FILTER lamp (Orange)
33 44
4 PRE. DEF lamp (Orange)
44 55
5 TIMER lamp (Yellow)
55 66
6 OPERATION lamp (Green/*Orange)
66
The operation lamps flash rapidly (five times per second), when safety protection features come into operation. * When the auto restart function is in operation, the
OPERATION lamp is orange.
TEMPORARY button
If you misplace or lose the remote control or its batteries are exhausted, push the TEMPORARY button.
Push the TEMPORARY button to start the air conditioner.
Push this button once again to stop it.
2 31 4 5 6
PRE.DEF TIMER OPERATIONFILTERHi POWER
TEMPORARY
button
3EN
REMOTE CONTROL AND ITS FUNCTIONS
13
14
11
15 12
10 18
17
16
11
1 Infrared signal emitter
11
Transmits a signal to the indoor unit.
22
2 START/STOP button
22
Press the button to start operation. (A receiving beep is heard.) Press the button again to stop operation. (A receiving beep is heard.) If no receiving sound is heard from the indoor unit, press the button twice.
33
3 Mode select button (MODE)
33
Press this button to select a mode. Each time you press the button, a mode is selected in a sequence that goes from A : Auto
+
, HIGH
: Cool,
, MED
: Dry,
)
,
)
see page 13.)
see page 13.)
changeover control,
: Heat,
(A receiving beep is heard.)
44
4 Temperature button (
44
....... The set temperature is increased up to 30 °C.
,
....... The set temperature is dropped down to 17 °C.
9
55
5 Fan speed button (FAN)
55
Press this button to select fan speed. When you select AUTO, the fan speed is automatically adjusted according to the room temperature. You can also manually select the desired fan speed from among five settings. (LOW
MED
(A receiving beep is heard.)
66
6 Auto louver button (SWING)
66
Press this button to swing the louver. (A receiving beep is heard.) Press the FIX button to stop the louver swinging. (A receiving beep is heard.) (
77
7 Set louver button (FIX)
77
Press this button to adjust the air flow direction. (A receiving beep is heard.) While this button is kept depressed, the receiving tone continuously sounds. (
88
8 Off timer button (OFF)
88
Press this button to set the OFF timer.
99
9 On timer button (ON)
99
Press this button to set the ON timer.
!!
! Reserve button (SET)
!!
Press this button to reserve time settings. (A receiving beep is heard.)
""
" Cancel button (CLR)
""
Press this button to cancel ON timer and OFF timer. (A receiving beep is heard.)
##
# High power button (Hi POWER)
##
Press this button to start the high power operation. (
: Fan only, and back to A.
(A receiving beep is heard.)
, LOW
+
see page 15.)
$$
$ Memory button (MEMO)
$$
Press this button to stand by memorizing the settings. Press the button again for more than 3 seconds to memorize the setting indicated on the remote control and mark is indicated. ( see page 12.)
%%
% Automatic operation button (AUTO)
%%
Press this button to operate the air conditioner automatically. (A receiving beep is heard.) ( see page 15.)
&&
& ECO timer button (ECO)
&&
Press this button to start the ECO timer (OFF timer) operation. You can select the OFF timer time from among four settings (1,3,5 or 9 hours). (
((
( FILTER button
((
Press this button to turn off the filter cleaning lamp on the indoor unit. Press this button after cleaning the air filter.
see page 17.)
(
))
) PRESET button
))
Press this button to operate the air conditioner according to settings memorized by the MEMO button. (
~~
~ TIMER button
~~
Use this button to change the clock, ON timer, and OFF timer times. To forward the time, press the “TIMER
To set back the time, press the “TIMER
see page 12.)
44
2
2 5
5 6
6 7
7 9
9 8
8
16
16
FAN MODE
SWING
FIX
ON
1
AUTOA
A B
PRESET
START/STOP
ECO
Hi-POWER
TIMER
MEMO
OFF SET CLR
FILTER
CLOCK CHECKRESET
AUTO
see page 15.)
” button.
” button.
13
17
3
3
14
14 15
15 12
12 13
17 11
11
10
10 18
18
4 EN
NAMES AND FUNCTIONS OF INDICATIONS ON REMOTE CONTROL
Display
All indications, except for cloc k time indication, are indicated by pressing the START/STOP button.
11
1 Transmission mark
11
This transmission mark (,) indicates when the remote control transmits signals to the indoor unit.
22
2 Mode display
22
Indicates the current operation mode. (AUTO : A utomatic control, A : Auto changeover control,
: Dry, : Heat,
33
3 Temperature display
33
: Fan only)
Indicates the temperature setting (17°C to 30°C). When you set the operating mode to
: Fan only, no temperature
setting is indicated.
44
4 FAN speed display
44
Indicates the selected fan speed. AUTO or one of five fan speed levels (LOW
HIGH
, LOW
, MED
) can be indicated.
, MED
+
+
Indicates AUTO when the operating mode is either AUTO or
55
5 TIMER and clock time display
55
The time set for timer operation or clock time is indicated. The present time is always indicated except for TIMER operation.
66
6 Hi POWER display
66
Indicates when the Hi POWER operation starts. Press the Hi POWER button to start and press it again to stop the operation.
77
7 (MEMORY) display
77
Flashes for 3 seconds when the MEMO button is pressed during operation.
mark is indicated when keeping the button depressed for more than 3 seconds while the mark is flashing. Press another button to turn off the mark.
88
8 ECO TIMER display
88
Indicates when the ECO TIMER is in operation. Each time you press the ECO button, the display changes in the sequence of 1,3,5 or 9h.
: Cool,
,
: Dry.
1
3
8
6
2
AUTOA
7
A B
4
5
In the illustration, all indications are indicated for explanation. During operation, only the relevant indications will be indicated on the remote control.
AUTO
A B
PREPARATION AND CHECK BEFORE USE
Loading the remote control batteries.
11
1 Remove the cover, and insert the batteries.
11 22
2 Press the RESET button.
22
The clock display flashes. Adjust the clock. Place back the cover.
Batteries
To replace the batteries, use two new batteries (AAA type).
In normal use, the batteries will last about one year.
Replace the batteries if there is no receiving beep from the
indoor unit or when the air conditioner cannot be operated using the remote control.
To avoid malfunctions by battery leakage, remove the batteries when not using the remote control for more than one month.
Slide off the cover while pressing the sides.
Battery replacement
Be careful not to reverse the (+) position and the (–) position.
5EN
FAN MODE
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
AUTO
ECO
Hi-POWER
MEMO
CLOCK CHECKRESET
2
Setting the clock
Before you start operating the air conditioner, set the clock of the remote control using the procedures given in this section. The clock panel on the remote control will indicate the time regardless of whether the air conditioner is in use or not.
Initial setting
When batteries are inserted in the remote control, the clock panel will indicate AM 0:00 and will flash.
PRESET
11
1 TIMER
11
Press the TIMER
button
button to set the current time. Each press of the TIMER button changes the time in one minute steps. Pressing the TIMER button continually changes the time in ten minute steps.
22
2 SET
22
SET
button
Press the SET
SET
button.
The current time is indicated and the clock starts.
Clock adjusting
11
1 CLOCK button
11
Press the CLOCK button. The CLOCK display flashes.
22
2 TIMER
22
button
Press the TIMER button to set the current time. Each press of the TIMER button changes the time by one minute. Pressing the TIMER button continually changes the time by ten minutes.
33
3 SET
33
SET
button
Press the SET
SET
button. The current time is indicated and the clock starts.
FAN MODE
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
ECO
Hi-POWER
MEMO
CLOCK CHECKRESET
AUTO
Push CLOCK
2 3
121 2
FAN MODE
SWING
FIX
ON
FAN MODE
SWING
FIX
ON
PRESET
START/STOP
AUTO
Hi-POWER
ECO
TIMER
MEMO
OFF SET CLR
FILTER
CLOCK CHECKRESET
START/STOP
AUTO
Hi-POWER
ECO
TIMER
MEMO
OFF SET CLR
FILTER
CLOCK CHECKRESET
1
Preparing the filters
11
1 Open the Air inlet grille with both
11
hands until the stop position.
22
2 Remove the Air filters from the
22
Front panel.
33
3 Install the Zeolite filter and
33
Purifying filter in the Filter frame and then install it to the Air filters.
44
4 Insert the Air filters in the Front
44
panel and hook them into position.
55
5 Close the Air inlet grille.
55
Filter frame
Zeolite filter Purifying filter
Air filter Air filter
Filter frame
6 EN
HANDLING THE REMOTE CONTROL
CAUTION
The air conditioner will not operate if curtains, doors or other materials block the signals from the remote control to the indoor unit.
Prevent any liquid from falling into the remote control. Do not expose the remote control to direct sunlight or heat.
If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner may not function properly. Use curtains to prevent the sunlight from reaching the receiver.
If the room using the air conditioner has fluorescent lighting with electronic starters, signals may not be properly received. If you are planning to use such fluorescent lamps, consult your local dealer.
If other electrical appliances react to the remote control, move these appliances or consult your local dealer.
Location of the remote control
Keep the remote control where its signals can reach the receiver of the indoor unit (a distance of 7m is allowed).
When you select the timer operation, the remote control automati­cally transmits a signal to the indoor unit at the specified time. If you keep the remote control in a position that hinders proper signal transmission, a time lag of up to 15 minutes may occur.
Remote control holder
Installing the remote control holder
Before you actually install the remote control holder on a wall or pillar, check whether the remote control signals can be received by the indoor unit.
7m
Mounting and removing the remote control
To mount the remote control, hold it parallel to the remote control holder and push it in fully. To remove the remote control, slide the remote control upwards and out from the holder.
7EN
AUTOMATIC OPERATION
When you set the air conditioner in AUTO mode, it will automatically select cooling, heating, or fan only operation depending on the room temperature. ( In addition, fan speed and louver are automatically controlled.
Start
11
1 START/STOP button
11
Press this button to start the air conditioner.
22
2 AUTO button (AUTO)
22
Press AUTO button.
The OPERATION lamp (green) on the display panel of the indoor unit lights. The operating mode is selected in accordance with the room temperature and operation starts after approximately 3 minutes.
If the AUTO mode is uncomfortable, you can select the desired conditions manually. Temperature, fan speed and louver position can be changed. When fan speed or louver position is changed, MODE is also changed from AUTO to A. At the same time, fan speed and louver positioning indications are indicated.
Stop START/STOP button
Press this button again to stop the air conditioner.
see page 15.)
AUTO
121 2
START/STOP
FAN MODE
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
ECO
PRESET
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
AUTOMATIC OPERATION (AUTO CHANGEOVER)
When you set the air conditioner in A mode or switch over from AUTO operation because of some settings change, it will automatically select cooling, heating, or fan only operation depending on the room temperature. ( see page 15.)
Start
11
1 START/STOP button
11
Press this button to start the air conditioner.
22
2 Mode select button (MODE)
22
Select A.
33
3 Temperature button (
33
)
Set the desired temperature.
The OPERATION lamp (green) on the display panel of the indoor unit lights. The operating mode is selected in accordance with the room temperature and operation starts after approximately 3 minutes.
When you select the A mode, it is unnecessary to set the fan speed. The FAN speed display will show AUTO and the fan speed will be automatically controlled.
If the A mode is uncomfortable, you can select the desired conditions manually.
Stop START/STOP button
Press this button again to stop the air conditioner.
3
3
1
1
2
2
A
START/STOP
FAN MODE
ECO
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
PRESET
Hi-POWER
MEMO
CLOCK CHECKRESET
AUTO
8 EN
COOLING/HEATING/FAN ONLY OPERATION
Start
11
1 START/STOP button
11
Press this button to start the air conditioner.
22
2 Mode select button (MODE)
22
Select Cool , Heat , or Fan only
33
3 Temperature button (
33
)
Set the desired temperature. Cooling 21°C or higher. Heating 28°C or lower . When the air conditioner is in FAN ONLY operation, the temperature display is not indicated.
44
4 Fan speed button (FAN)
44
Select one of “AUTO” LOW
MED
+
, HIGH
, LOW
The OPERATION lamp (green) on the display panel of the indoor unit goes on. And operation starts after approximately 3 minutes. (if you select FAN ONLY mode, the unit will start immediately.)
The
: Fan only mode does not control temperature.
Therefore, perform only steps 1, 2 and 4 to select this mode.
Stop START/STOP button
Press this button again to stop the air conditioner.
.
3
131
424
+
, MED
,
2
START/STOP
FAN MODE
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
ECO
PRESET
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
DRY OPERATION
Start
11
1 START/STOP button
11
Press this button to start the air conditioner.
22
2 Mode select button (MODE)
22
Select DRY
33
3 Temperature button (
33
Set the desired temperature.
The fan speed display indicates AUTO.
The OPERATION lamp (green) on the display panel of the indoor
unit lights, and operation starts after approximately 3 minutes.
Stop START/STOP button
Press this button again to stop the air conditioner.
)
3
3
1
1
2
2
FAN MODE
SWING
FIX
ON
OFF SET CLR
FILTER
PRESET
START/STOP
ECO
TIMER
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
9EN
Hi POWER OPERATION
High power (Hi POWER)
The Hi POWER (high power operation) mode automatically controls room temperature, air flow and operation mode so that the room is quickly cooled in summer and warmed in winter. ( see page 15.)
Setting Hi POWER mode
11
1 Hi POWER button
11
Press the Hi POWER button. The Hi POWER lamp (green) on the display panel of the indoor unit lights up. At the same time, the Hi POWER” mark on the remote control is indicated.
A
PRESET
START/STOP
Canceling Hi POWER mode
11
1 Hi POWER button
11
Press the Hi POWER button once again. The Hi POWER lamp on the display panel of the indoor unit lights goes out. At the same time, the Hi POWER” mark on the remote control goes out.
CAUTION
The Hi POWER mode cannot be activated in the DRY and FAN ONLY operation and when the ON TIMER operation is reserved.
TIMER OPERATION
ON timer and OFF timer Setting TIMER
11
1 ON/OFF TIMER button
11
Press the ON or OFF TIMER buttons as required.
The previous timer setting is displayed and flashes along with ON/OFF TIMER display.
22
2 TIMER
22
Press the TIMER button. Set the timer to the desired time. Each press of the TIMER button changes the time in ten minute steps. Pressing the TIMER button continually changes the time in one hour steps.
33
3 SET
33
Press the SET The timer time is indicated and the timer starts.
44
4 CLR
44
Press the CLR
When you select the timer operation, the remote control automatically transmits the timer signal to the indoor unit at the specified time. Therefore, keep the remote control in a location where it can transmit the signal to the indoor unit properly.
If you do not press the SET setting the time, the setting will be cancelled.
button
SET
button
CLR
SET
button
CLR
CAUTION
button to set the timer.
button to cancel the timer setting.
SET
button within 30 seconds after
FAN MODE
1
1
1
1
2
2 3
3 4
4
SWING
FIX
ON
OFF SET CLR
FILTER
START/STOP
FAN MODE
SWING
FIX
ON
OFF SET CLR
FILTER
ECO
TIMER
ECO
TIMER
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
PRESET
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
Once you select the timer operation mode, the settings are saved in the remote control. Thereafter, the air conditioner will start operating under the same conditions when you simply press the ON/OFF button of the remote control.
If the clock display is flashing, you cannot set the timer. Follow the instructions in the section SETTING THE CLOCK on page 6 to set the clock, and then set the timer.
10 EN
Combined timer (Setting both ON and OFF timers simultaneously) OFF timer —> ON timer (Operation —> Stop —> Operation)
This feature is useful when you want to stop the air conditioner after you go to sleep, and start it again in the morning when you wake up or you return home. Example: To stop the air conditioner and start it again next morning.
Setting combined TIMER
(1) Press the OFF
(2) Press the TIMER
OFF
button.
button to adjust the OFF timer. (3) Press the ON ON button. (4) Press the TIMER (5) Press the SET
button to adjust the ON timer.
SET
button.
Operation
Operation again
Stop
ON timer —> OFF timer (Stop —> Operation —> Stop)
You can use this setting to start the air conditioner when you wake up and stop it when you leave the house. Example: To start the air conditioner next morning and stop it.
Setting combined TIMER
(1) Press the ON ON button. (2) Press the TIMER
(3) Press the OFF
(4) Press the TIMER
(5) Press the SET
button to adjust the ON timer.
OFF
button.
button to adjust the OFF timer.
SET
button.
Stop Stop
Operation
Either ON or OFF timer function which is closer to the current
time, is activated first.
If the same time is set for both ON and OFF timers, no timer
operation is performed. Also, the air conditioner may stop operating.
Every day combined timer (setting both ON and OFF timer simultaneously and activate every day.)
This feature is useful when you want to use combined timer at the same time every day.
Setting combined TIMER
(1) Press the ON ON button. (2) Press the TIMER
(3) Press the OFF
(4) Press the TIMER
(5) Press the SET (6) After step (5), an arrow mark (
3 seconds and during this flashing, press the SET
During the every day timer is activating, both arrows (
Cancel the timer operation
Press the CLR
Clock display
During the TIMER operation (ON-OFF, OFF-ON, OFF timer) clock display is disappeared so as to show the setting time. To see the present time, press SET button briefly and the present time is displayed about 3 seconds.
button to adjust the ON timer.
OFF
button.
button to adjust the OFF timer.
SET
button.
or
CLR
button.
) flashes for about
SET
button.
,
) are indicated.
A
START/STOP
FAN MODE
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
PRESET
ECO
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
11EN
MEMORY/PRESET OPERATION
Memorize the frequently used operation setting by the MEMO button for convenience. Start the air conditioner in the operation mode which you want the remote control to memorize. Press the button as follows while the air conditioner is in operation.
11
1 MEMO button
11
Press this button briefly to standby memorizing the setting. All the icons currently displayed except for the clock display and
mark flashes.
22
2 MEMO button
22
Press and hold the MEMO button for more than 3 seconds while the display flashes. The mark is indicated and the setting is memorized.
If you do not press the MEMO button within 3 seconds or if you
press another button, the MEMORY setting is cancelled.
Operation modes which can be memorized with the MEMO button
are MODE, Temperature, FAN, TIMER and Hi POWER.
PRESET
START/STOP
FAN MODE
121 2
SWING
FIX
ON
OFF SET CLR
FILTER
ECO
TIMER
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
To operate the air conditioner with the setting memorized by the MEMO button.
11
1 PRESET button
11
Press the PRESET button. The setting memorized with the MEMO button will be indicated and the air conditioner operates with regards to the setting.
The OPERATION lamp (green) on the display panel of the indoor
unit goes on, and operation starts after approximately 3 minutes.
Initial setting:
MODE : AUTO Temperature : 22
PRESET
11
START/STOP
FAN MODE
SWING
TIMER
FIX
ON
OFF SET CLR
FILTER
ECO
AUTO
Hi-POWER
MEMO
CLOCK CHECKRESET
12 EN
ADJUSTING AIR FLOW DIRECTION
Adjust the air flow direction properly. Otherwise, it might cause
discomfort and make the room temperature uneven.
Adjust the vertical air flow using the remote control.
Adjust the horizontal air flow manually.
Adjust the vertical air flow
The air conditioner automatically adjusts the vertical air flow direction in accordance with the operating conditions when AUTO or A mode is selected.
To set the air flow direction you desire
Perform this function when the air conditioner is in operation.
11
1 FIX button
11
Keep pressing or pressing briefly the FIX button on the remote control to move the louver in the desired direction.
Change the vertical air flow louver direction within the range
indicated.
In subsequent operations, the vertical air flow is automatically set
in the direction to which you adjusted the louver using the FIX button.
To automatically swing the air flow direction
Perform this function when the air conditioner is in operation.
11
1 SWING button
11
Press the SWING button on the remote control.
To stop the function, press the FIX button.
To change the swing direction, press the FIX button and press
the SWING button agin.
CAUTION
The FIX and SWING buttons will be disabled when the air conditioner is not in operation (including when the ON TIMER is set).
Do not operate the air conditioner for long hours with the air flow direction set downward during the cooling or dry operation. Otherwise, condensation may occur on the surface of the vertical air flow louver and cause dew dripping.
Do not move the vertical air flow louver manually. Always use the FIX button. If you move the louver manually, it may malfunction during operation. If the louver malfunctions, stop the air conditioner once, and restart.
When the air conditioner is started immediately after it was stopped, the vertical air flow louver might not move for 10 seconds or so.
PRESET
START/STOP
FAN MODE
AUTO
Hi-POWER
ECO
SWING
TIMER
MEMO
1
1
1
1
FIX
ON
OFF SET CLR
START/STOP
FAN MODE
SWING
FIX
ON
OFF SET CLR
TIMER
PRESET
AUTO
Hi-POWER
ECO
MEMO
Adjust the horizontal air flow Preparation:
Take hold of the lever on the horizontal air flow louver and move them to adjust the air flow direction as required.
You can adjust the air flow at the left, center, and right locations of the grilles.
13EN
AUTO RESTART OPERATION
PRE.DFILTERHi POWER
PRE.DFILTERHi POWER
This air conditioner is equipped with an Automatic restarting facility which allows the air conditioner to resume the set operating conditions in the event of a supply power shutdown without the use of the remote control. The operation will resume without warning three minutes after the power is restored.
INFORMATION
The AUTO RESTART OPERATION is not set to work on shipment from the factory, and so it is necessary to set it to function as required.
HOW TO SET THE AUTO RESTART
To set the auto restart function, proceed as follows: The power supply to the unit must be on the function will not set if the power is off. To enable the auto restart function, push the TEMPORARY button continually for 3 seconds. The air conditioner will acknowledge the setting and beep 3 times. The system will now restart automatically. The above auto restart settings can be carried out: (1) When the air conditioner is in stand-by (not running).
Push the TEMPORARY button for more than 3 seconds.
The air conditioner starts to operate. The green lamp will be indicated.
About 3 seconds after, the air conditioner beeps 3 times. The lamp will change from green to orange.
The air conditioner is operating.
If the air conditioner is not required to run at this time, push the TEMPORARY button once more or use the remote control to stop the air conditioner.
(2) When the air conditioner is in operation.
Push the TEMPORARY button for more than 3 seconds.
The air conditioner stops operating. The green lamp goes off.
The air conditioner beeps 3 times 3 seconds later, after pushing the button.
The air conditioner stops.
If the air conditioner is not required to stop at this time, use the remote control to restart the air conditioner. During the subsequent operation, the orange lamp is indicated.
The auto restart operation will not accept an instruction if timer operation with the remote control is selected.
The louver swing (AUTO) operation will not resume, after restarting the air conditioner by the AUTO
RESTART OPERATION.
TEMPORARY
button
HOW TO CANCEL THE AUTO RESTART
To cancel the auto restart operation, proceed as follows: Repeat the setting procedure: the air conditioner will acknowledge the instruction and beep three times. The air conditioner will now require to be manually restarted with the remote control after the main supply is turned off. Cancellation is carried out: (1) When the air conditioner is in stand-by (not running).
Push the TEMPORARY button for more than 3 seconds.
The air conditioner starts to operate. The orange lamp will be indicated.
About 3 seconds after, the air conditioner beeps 3 times. The lamp will change from orange to green.
The air conditioner is operating.
If the air conditioner is not required to run at this time, push the TEMPORARY button once more or use remote control to stop the air conditioner.
(2) When the air conditioner is in operation.
Push the TEMPORARY button for more than 3 seconds.
The air conditioner stops operating.
TEMPORARY
button
The orange lamp is turned off.
About 3 seconds after, the air conditioner beeps 3 times.
The air conditioner stops.
If the air conditioner is not required to stop at this time, use the remote control to restart the air conditioner. During subsequent operation, the green lamp is indicated.
14 EN
HOW THE AIR CONDITIONER WORKS
Automatic operation
The air conditioner selects and operates in one of the operating modes of cooling, heating, or fan only, depending on the room temperature.
If the AUTO mode is uncomfortable, you can select the desired conditions manually.
Room temperature in operation
The set temperature +1°C or higher (in case that the room is hot )
Cooling operation
Operating condition
Performs the cooling operation at a temperature 1°C higher than the setting.
Performs the fan only operation (low speed) while
The set temperature –1°C to +1°C
Fan only operation
monitoring the room temperature. When the room temperature changes, the air conditioner will select the cooling or heating mode.
The set temperature –1°C or lower (in case that the room is cold )
Heating operation
Performs the heating operation at a temperature 1°C lower than the setting.
Hi POWER operation
When you press the Hi POWER button during cooling, heating or A operation, the air conditioner will start the following operation.
Cooling operation Performs the cooling operation lower than the setting temperature. When the room temperature is above the setting temperature, air flow is directed downward. In addition, f an
speed is high*. Once room temperature is within 1°C of the setting temperature, air flow is returned to its regular direction to cool the entire room with maximum efficiency.
* Noise level raises in accordance with fan speed.
Heating operation
Performs the heating operation at 2°C higher than the setting temperature.
ECO timer operation
When you press the ECO button during cooling, heating or A operation, the air conditioner will start the following operation. The fan speed will be automatically controlled.
Cooling operation ( )
In the operation suppression zone, where capacity is kept to the minimum, overcooling is prevented by raising the temperature setting by 1°C after 1 hour and by 2°C after 2 hours of operation. The room temperature is thus regulated between the operation suppression zone and the set temperature.
1°C
1 hour
2 hours
Operation starts
Operation suppression zone
2°C
Set temperature
Heating operation ( )
In the operation suppression zone, where capacity is kept to the minimum, overheating is prevented by lowering the temperature setting by 1°C after 1 hour and by 2°C after 2 hours of operation. The room temperature is thus regulated between the set temperature and the operation suppression zone.
15EN
Set temperature
1°C
1 hour
Operation starts
2 hours
2°C
Operation suppression zone
PRE.DFILTERHi POWER
DRY operation (
)
The dry mode will automatically select the cooling dry operation based on the difference between the set temperature and the actual room tempera­ture.
Cooling dry operation
This operation is performed when the room temperature is higher than the set temperature. The temperature is regulated while dehumidifying by repeated turning on and off of the cooling operation or fan only operation. The fan speed display will indicate AUTO and low speed will be used.
HINTS FOR ECONOMICAL OPERATION
Maintain room temperature at comfortable level Clean air filters
The clogged air filters impairs the performance of the air conditioner. Clean them once two weeks.
Never open doors and windows more often than necessary
To keep cool or warm air in the room, never open doors and windows more often than necessary.
Window curtains
In cooling, close the curtains to avoid direct sunlight. In heating, close the curtains to keep the heat in.
Use the timer effectively
Set the timer for the desired operating time.
Get uniform circulation of room air
Adjust air flow direction for even circulation of room air.
Cooling Fan only Cooling Fan only Cooling
Set temperature
Room temperature
Clean, please
Time
Gee, chilly
Control
Use the timer
effectively
TIMER
Blows upward
Cool and dry air
TEMPORARY OPERATION
TEMPORARY operation
This function is used to operate the unit temporarily in case you misplace the remote control or its batteries are exhausted.
Push the TEMPORARY button to start the air conditioner.
While the substitute operation is set, the remote control operation is
disabled.
Continue to press the button for 10 seconds to start the cooling
operation.
Air filter reset
When the FILTER lamp on the air conditioner is indicated, it is time for cleaning. (The lamp will start to indicate, after every 1000 hours of operation.)
The FILTER lamp will go out when the TEMPORARY button is pushed.
The FILTER lamp will also go out when the FILTER button on the
remote control is pressed. (
see page 4.)
e
s
lo
c
e
s
a
le
P
I cannot find the
Blows downward
remote control
Warm air
Air flow adjustment
A temporary
operation feature
is provided!
TEMPORARY
button
16 EN
MAINTENANCE
WARNING
Before you clean the air conditioner, be sure to turn off the circuit breaker, or main power switch.
Cleaning of indoor unit and remote control
CAUTION
Use a dry cloth to wipe the indoor unit and remote control.
A cloth dampened with cold water may be used on the indoor unit if it
is very dirty.
Never use a damp cloth on the remote control.
Do not use a chemically-treated duster for wiping or leave such
materials on the unit for long. It may damage or fade the surface of the unit.
Do not use benzine, thinner, polishing powder, or similar solvents for cleaning. These may cause the plastic surface to crack or deform.
If you will not use the unit for at least 1 month
(1) Operate the air conditioner in FAN ONLY mode for about half a da y to
dry the inside of the unit. (2) Stop the air conditioner and turn off the circuit breaker. (3) Remove the batteries from the remote control.
Check before operation
CAUTION
Check that the Air filters are installed.
Check that the Air outlet or inlet of the outdoor unit is not blocked.
Cleaning the Air filter
Clean the Air filters every 2 weeks. If the Air filters are covered with dust, the performance of the air conditioner will deteriorate.
Wipe with dry cloth
With
the MODE
button set to
FAN ONLY.
FAN ONLY operation
Clean the Air filters as often as possible.
11
1 Open the Air inlet grille with both hands until the stop position.
11
22
2 Remove the Air filters from Front panel.
22
33
3 Remove the Zeolite filter and Purifying filter from the Air filters.
33
44
4 Use a vacuum cleaner to remove the dust from the filters or wash
44
them with water.
If you wash the Air filters, dry them in the shade.
55
5 Install the Zeolite filter and Purifying filter in Filter frame.
55
66
6 Insert the Air filters into the front panel guide, and hook it
66
into position.
77
7 Close the Air inlet grille.
77
If the FILTER lamp on the indoor unit is indicated, press the
FILTER button on the remote control, or the TEMPORARY
button on the indoor unit to turn off the lamp.
17EN
Filter frame
Zeolite filter
Air filter
Filter frame
Purifying filter
Air filter
INFORMATION
Zeolite Filter
Clean Zeolite filter every 6 months.
- Expose the Zeolite filter to the sunlight for 6 hours.
- If the Zeolite filter is dirty, wash it by water without soap and expose it to the sun for 6 hours.
Even if Zeolite filter is renewable, the deodorant performance will drop due to extended use. It is recommended to replace the filter once every 3 years. Optional: Zeolite filter (RB-A604DE)
Purifying Filter
Clean the Purifying filter once every 2 weeks.
If the filter is dusty, clean it with a vacuum cleaner.
It is recommended to replace the filter once every 3 months so
as to keep the purifying performance. When it is very dirty, replace it with new one eventhough the period of use is within 3 months. Optional: Purifying filter (RB-A602SE)
Purifying filter (Inside)
Zeolite filter (Inside)
18 EN
AIR CONDITIONER OPERATIONS AND PERFORMANCE
Three-minute protection feature
A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after operation or when the power supply switch is set to on. This will protect the machine.
Heating characteristics Preheating operation
The air conditioner will not deliver warm air immediately after it is started. Warm air flows out after approximately 5 minutes when the indoor heat exchanger warms up. (The PRE.DEF lamp is on during this intervals indicating the preheating operation.)
Warm air control
When the room temperature reaches the set temperature, the fan indoor speed is automatically reduced to prevent a cold draft. At this time, the outdoor unit will stop.
Defrosting
If the outdoor unit is frosted during heating operation, defrosting is started automatically (for approximately 5 to 10 minutes) to maintain the heating effect, and the PRE.DEF lamp is on.
The fans in both the indoor and outdoor units stop during the defrost operation.
During defrost operation, defrosted water is drained from the bottom plate of the outdoor unit.
Heating capacity
In the heating operation, heat is absorbed from outdoors and released into the room. That is called the heat pump system. When the outdoor temperature is too low, to use another heating apparatus in combination with the air conditioner is recommended.
Consideration for accumulated snow
Select the position for the outdoor unit where it will not be subjected to snow drifts, accumulation of leaves or other seasonal debris. It is important that the air flow of the outdoor unit is not impeded as this will result in reduced heating or cooling performance. During the heating mode, and at sub-zero temperatures, the water drained off the outdoor unit as a result of the automatic defrost may accumulate and freeze. It is important that adequate drainage or a soak-way is provided.
Power failure
Power failure during operation will stop the unit completely.
The OPERATION lamp (green) on the indoor unit will start flashing when power is restored.
To restart operation, push the START/STOP button on the remote control.
Lightning or a car wireless telephone operating nearby may cause the unit to malfunction. Turn the power
supply switch to off and then to on. Push the START/STOP button on the remote control to restart.
Air conditioner operating conditions
For proper performance, operate the air conditioner under the following temperature conditions:
Cooling operation
Outdoor temperature: 15°C to 43°C Room temperature: 21°C to 32°C
CAUTION
Room relative humidity – less than 80%. If the air conditioner operates in excess of this figure, the surface of the air conditioner may attract condensation.
Heating operation
Dry operation
If the air conditioner is used in conditions other than above, safety protection features may come into operation.
Outdoor temperature: –10°C to 24°C Room temperature: Less than 28°C Outdoor temperature: 15°C to 43°C Room temperature: 17°C to 32°C
19EN
TROUBLES AND CAUSES
CAUTION
If any of the following conditions occur, stop the air conditioner immediately, set to off the main power switch and contact the dealer:
The indicator lamps blink at short intervals (5 Hz). Reset the circuit breaker 2 to 3 minutes after the power main switch is turned off. Despite the above-mentioned resetting the lamps still continue going on and off.
Switch operation are erratic.
The main power fuse often blows out, or the circuit breaker is often activated.
Foreign matter or water has fallen inside the air conditioner.
Any other unusual condition is observed.
Before you ask for servicing or repairs, check the following points.
Inoperative
The power main switch is turned off.
The circuit breaker is activated to cut off the power supply.
The main power fuse has blown out.
Stoppage of electric current.
The batteries in the remote control are exhausted.
ON timer is set.
Poor cooling or heating performance
The air inlet or outlet of the outdoor unit is blocked.
Doors or windows are opened.
The air filter is clogged with dust.
The louver is not at the correct position.
The fan speed is set to low.
The air conditioner is set in the DRY mode.
The set temperature is too high. (In cooling operation)
Recheck
The set temperature is too low. (In heating operation)
20 EN
Before you ask for servicing or repairs, check the following points.
The back of indoor unit is dewed.
Dewdrops on the back of the indoor unit are automatically collected and drained out.
Indoor unit or outdoor unit makes a strange noise.
When temperature sharply changes, the indoor or outdoor unit occasionally makes a strange noise (like tit-tack noise or flowing noise) because of expansion/contraction of parts or change of refrigerant flow.
The room air is smelly. A bad odor comes from the air conditioner.
Smells impregnated in the wall, carpet, furniture, clothing, or furs, are coming out.
The OPERATION lamp goes on and off.
The lamp goes on and off 1 Hz when power is restored after a power failure, or when the power main switch is set to on. Reset the circuit breaker to ON.
Outdoor unit is frosted in heating operation. Water is drained out of outdoor unit.
The outdoor unit is sometimes frosted in heating operation. In that case, the unit automatically performs defrosting (for 2 to 10 minutes) for raising the heating efficiency.
In defrosting operation, both the indoor and outdoor units stop air flow.
Hiss sound is heard when flow of the refrigerant is changed for
These are not failures.
defrosting.
Resultant water of automatic defrosting in heating operation is drained out of the outdoor unit.
Air flow changes though the FAN button is not set to the AUTO mode.
When the temperature of blown air goes down in heating operation, the air conditioner automatically changes or stops air flow from the indoor unit not to make persons in the room feel chilly.
A white mist of chilled air or water is generated from the outdoor unit.
The indoor unit in cooling operation or the outdoor unit in defrosting operation occasionally steams.
Automatic operation of vertical air flow louver.
When the room temperature or outdoor temperature is high in the heating operation, the vertical air flow louver once close and then set themselves automatically to the original set position again.
21EN
SPECIFICATIONS
Type Model
Power supply Cooling capacity (kW) CAPA. Heating capacity (kW) CAPA. Cooling Amps (A) AMP. Cooling Watts (W) WA TT. Heating Amps (A) AMP. Heating Watts (W) WATT.
Width (mm)
Dimension Height (mm)
Depth (mm)
Net weight (kg)
Indoor Unit
RAS-18UFHP-ES
50Hz, 220-240 V~
5.00 – 5.10
5.70 – 5.80
0.40 – 0.40 85 – 85
0.40 – 0.40
85 –85
1093
633 208
23
The specifications may be subject to change without notice for purpose of improvement. The specified air-conditioning capabilities are based on the data determined under the following conditions:
For cooling
Air-inlet temperature °C
Indoor coil assembly
Dry bulb
27
Wet bulb19Dry bulb35Wet bulb
Outdoor coil assembly
24
Reverse cycle, Split type
Outdoor Unit
RAS-18UAH-ES
8.60 – 8.30
1875 – 1925
7.70 – 7.60
1665 – 1745
830 538 300
51
For heating
Air-inlet temperature °C
Indoor coil assembly
Dry bulb
20
Indoor Unit
RAS-18UFHP-E
50Hz, 220-240 V~
5.00 – 5.00
5.70 – 5.80
0.40 – 0.40 85 – 85
0.40 – 0.40 85 – 85
1093
633 208
23
Outdoor coil assembly
Wet bulb—Dry bulb7Wet bulb
Outdoor Unit
RAS-18UAH-E,-EA
9.20 – 9.85
1915 – 2045
8.50 – 9.50
1745 – 1915
830 538 300
54
6
Type Model
Power supply Cooling capacity (kW) CAPA. Heating capacity (kW) CAPA. Cooling Amps (A) AMP. Cooling Watts (W) WA TT. Heating Amps (A) AMP. Heating Watts (W) WATT.
Width (mm)
Dimension Height (mm)
Depth (mm)
Net weight (kg)
Indoor Unit
RAS-24UFHP-ES
50Hz, 220-240 V~
6.20 – 6.30
7.00 – 7.10
0.45 – 0.45 95 – 95
0.45 – 0.45 95 – 95
1093
633 208
23
Reverse cycle, Split type
Outdoor Unit
RAS-24UAH-ES
11.45 – 10.80 2415 – 2395
11.10 – 11.15
2335 – 2435
880 690 310
67
Indoor Unit
RAS-24UFHP-E
50Hz, 220-240 V~
6.10 – 6.20
6.80 – 6.90
0.45 – 0.45 95 – 95
0.45 – 0.45 95 – 95
1093
633 208
23
Outdoor Unit
RAS-24UAH-E,-EA
11.15 – 11.85 2385 – 2555
11.20 – 12.00 2395 – 2575
880 690 310
66
The specifications may be subject to change without notice for purpose of improvement. The specified air-conditioning capabilities are based on the data determined under the following conditions:
For cooling
Air-inlet temperature °C
Indoor coil assembly
Dry bulb
27
Wet bulb19Dry bulb35Wet bulb
Outdoor coil assembly
24
For heating
Air-inlet temperature °C
Indoor coil assembly
Dry bulb
20
Wet bulb—Dry bulb7Wet bulb
Outdoor coil assembly
6
22 EN
TROUBLES AND CAUSES (Concerning Remote Control)
Before you ask for servicing or repairs, check the following points.
Setting Change Is Impossible
Symptoms
Causes
Reason and Disposal
The fan speed cannot be changed.
Symptoms
The temperature display does not go on.
Symptoms
The indication on the display disappears after a lapse of time.
Check whether the MODE indicated on the display is “AUTO”.
AUTO
Check whether the MODE indicated on the display is “
The Display Never Goes On
Check whether the MODE indicated on the display is “
: FAN ONLY
The Display Goes Off
Check whether the timer operation has come to an end when the OFF TIMER is indicated on the display.
: DRY”.
: DRY
Causes
: FAN ONLY”.
Causes
When the automatic mode is selected, the air conditioner automatically selects the fan speed.
When dry operation is selected, the air conditioner automatically selects the fan speed. The fan speed can be selected during “ COOL”, “ HEAT” and “
FAN ONLY”.
Reason
The temperature cannot be set during fan only operation.
Reason
The air conditioner stops since the setting time elapsed.
The TIMER display goes off after a certain period of time.
Symptoms
No receiving tone sounds from the indoor unit even when the START/STOP button is pushed.
Check whether the timer operation has started when the ON TIMER is indicated on the display.
: ON
When the time reaches the setting time for the ON timer operation, the air conditioner starts to operate automatically and the ON timer display goes off.
The Signal Receiving Tone Does Not Sound
Causes
Check whether the signal trans­mitter of the remote control is properly directed to the receiver of the indoor unit when the START/ STOP button is pushed.
Direct the signal transmitter of the remote control to the receiver of the indoor unit, and then repeatedly press the START/STOP button.
23EN
Reason