PRECAUTIONS FOR SAFETY
• Do not install, repair, open or remove the cover. It may expose you to
dangerous voltages. Ask the dealer or the specialist to do this.
• Turning off the power supply will not prevent potential electric shock.
DANGER
WARNING
CAUTION
1
INDOOR UNIT DISPLAY
Hi POWER FILTER PRE.DEF TIMER OPERATION
12
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1. Push CLOCK O by tip of the pencil.
2. Press
3. Press
Remote Control Reset
1. Remove the battery.
2. Press
3. Insert the battery.
3
AIRFLOW DIRECTION
1
2
• The appliance shall be installed in accordance with national wiring
regulation.
• Means for disconnection from the supply having a contact separation
of at least 3 mm in all poles must be incorporated in the fi xed wiring.
• Do not expose your body directly to cool air for a long time.
• Do not insert your fi nger or any article into the air inlet/outlet.
• When an abnormality (burning smell, etc.) occurs, stop the air
conditioner and disconnect the power supply or turn off the breaker.
• This appliance is not intended for use by persons (including children)
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person responsible
for their safety.
• Children should be supervised to ensure that they do not play with the
appliance.
• Do not wash the unit with water. It may cause an electric shock.
• Do not use this air conditioner for other purposes such as preserving
food, breeding animal, etc.
• Do not step or put anything on the indoor/outdoor unit. It may cause
an injury or damage the unit.
• Do not touch aluminium fi n because it may cause an injury.
• Before cleaning the unit, turn off the main switch or the circuit breaker.
• When the unit won’t be used for a long time, turn off the main switch
or the circuit breaker.
• It is recommended that maintenance be performed by a specialist
when the unit has been operated for a long time.
1 Hi POWER (Green)
2 FILTER (Orange)
3 PRE.DEF
(DE-FROST) (Orange)
4 TIMER (Yellow)
RESET
5 OPERATION (Green)
6
6 RESET button
3
ON
or
SET
: Set the time.
45
OFF
: adjust the time.
.
Press
FIX
: Move the louver in
the desired vertical direction.
SWING
Press
: Swing the air
automatically and press again to
stop.
4
REMOTE CONTROL
1 Infrared signal emitter
2 Start/Stop button
3 Mode select button (MODE)
4 Temperature button (TEMP)
5 Fan speed button (FAN)
6 Swing louver button (SWING)
7 Set louver button (FIX)
8 On timer button (ON)
9 Off timer button (OFF)
! Sleep timer button (SLEEP)
" Setup button (SET)
# Clear button (CLR)
$ Memory and Preset button (PRESET)
% One Touch button (ONE-TOUCH)
& High power button (Hi-POWER)
( Economy button (ECO)
) Quiet button (QUIET)
~ Comfort sleep button
(COMFORT SLEEP)
+ Filter reset button (FILTER)
, Clock Reset button (CLOCK)
- Check button (CHK)
5
ONE-TOUCH
Press the “ONE-TOUCH” button for fully automated operation that is
customised to the typical consumer preferences in your region of the world.
The customised settings control temperature air fl ow strength, air fl ow
direction and other settings to provide you alternate contact with “ONETOUCH” of the button. If you prefer other settings you can select from the
many other operating functions of your Toshiba unit.
Press
6
To automatically select cooling, heating, or fan only operation
1. Press
A
C
L
2. Press
7
1. Press
2. Press
3. Press
8
For dehumidifi cation, a moderate cooling performance is controlled
automatically.
1. Press
2. Press
9
To automatically control room temperature and airfl ow for faster cooling or
heating operation (except in DRY and FAN ONLY mode)
Press
ONE-TOUCH
: Start the operation.
AUTOMATIC OPERATION
MODE
: Select A.
TEMP
: Set the desired temperature.
COOLING / HEATING / FAN ONLY OPERATION
MODE
: Select Cool , Heat , or Fan only .
TEMP
: Set the desired temperature.
Cooling: Min. 17oC, Heating: Max. 30oC, Fan Only: No temperature
indication
MED+ , or HIGH .
FAN
: Select AUTO, LOW , LOW+ , MED ,
DRY OPERATION (COOLING ONLY)
MODE
: Select Dry .
TEMP
: Set the desired temperature.
Hi-POWER OPERATION
Hi-POWER
: Start and stop the operation.
$
%
2
)
6
7
8
!
+
PRESET
ONE-TOUCH
QUIET
SWING
TIMER
SLEEP
1
TEMP
FIX Hi-POWER ECO
ON
FILTER
CHK
FAN
5
4
MODE
3
~
COMFORT
SLEEP
&
(
CLR
OFF
CLOCK
#
9
SET
"
,
1110250165.indb 2
For horizontal direction, adjust
3
manually.
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by come operation mode.
10
ECO OPERATION
To automatically control room to save energy (except in DRY and FAN ONLY
mode)
Press
Note: Cooling operation; the set temperature will increase automatically 1
ECO
: Start and stop the operation.
degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation the set temperature will decrease.
10/27/09 3:58:48 PM
11
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
• Pressing the RESET button, the unit can start or
stop without using the remote control.
• Operation mode is set on AUTOMATIC operation,
preset temperature is 24°C and fan operation is
automatic speed.
12
TIMER OPERATION
Setting the ON Timer Setting the OFF Timer
1
2
3
Daily timer allows the user to set both the ON & OFF timers and will be
activated on a daily basis.
Setting Daily Timer
1
2
• During the daily timer is activating, both arrows ( , ) are indicated.
Note:
• Keep the remote control in accessible transmission to the indoor unit;
• The setting will be saved for the next same operation.
13
PRESET OPERATION
Set your preferred operation for future use. The setting will be memorized by
the unit for future operation (except airfl ow direction).
1. Select your preferred operation.
2. Press and hold
The P mark displays.
3. Press
14
AUTO RESTART OPERATION
To automatically restart the conditioner after the power failure (Power of the
unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set
• Do not operate ON timer and OFF timer.
2. Press and hold the RESET button on the indoor unit for 3 seconds to
15
QUIET OPERATION
To operate at super low fan speed for quiet operation (except in DRY mode)
Press
Note: Under certain conditions, QUIET operation may not provide adequate
16
COMFORT SLEEP OPERATION
To save energy while sleeping, automatically control air fl ow and
automatically turn OFF.
Press
Note: The cooling operation, the set temperature will increase automatically
17
SLEEP TIMER OPERATION
To start the sleep timer (OFF timer) operation
Press
ON
Press
Press
Press
Press
Press
otherwise, the time lag of up to 15 minutes will occur.
the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for
5 seconds)
cancel the operation. (3 beep sound but OPERATION lamp does not
blink)
cooling or heating due to low sound features.
1 degree/hour for 2 hours (maximum 2 degrees increase). For heating
operation, the set temperature will decrease.
: Set the desired ON timer.
SET
: Set the timer. Press
CLR
: Cancel the timer. Press
ON
: Set the ON timer.
OFF
: Set the OFF timer.
PRESET
for 3 seconds to memorize the setting.
PRESET
: Operate the preset operation.
QUIET
: Start and stop the operation.
COMFORT
SLEEP
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
SLEEP
: Select 1, 3, 5 or 9 hrs for OFF timer operation.
Press
3
Press
Press
4
( or ) mark fl ashing.
OFF
: Set the desired OFF timer.
SET
: Set the timer.
CLR
: Cancel the timer.
SET
.
SET
button during the
18
MAINTENANCE
Firstly, turn off the circuit breaker.
Filter Reset (Some models only)
FILTER lamp lights on; the fi lter must be cleaned.
To turn off the lamp, push the RESET button on the indoor unit or the FILTER
button on the remote control.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when
needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
19
SELF CLEANING OPERATION (COOL AND DRY OPERATION ONLY)
To protect bad smell caused by the humidity in the indoor unit.
1. If the
2. To stop the unit immediately, press the
Note:
• SELF CLEANING operation is default setting from factory.
• To cancel this function, please contact the supplying retail dealership.
20
1. Three-minute protection feature: To prevent the unit from being activated
2. Preheating operation: Warm up the unit for 5 minutes before the heating
3. Warm air control: When the room temperature reaches the set
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoors and released into
6. Consideration for accumulated snow: Select the position for outdoor unit
7. Some minor cracking sound may occur when unit operating. This is
Air conditioner operating conditions
Operation
Heating –15°C ~ 24°C Less than 28°C
Cooling –10°C ~ 46°C 21°C ~ 32°C
Dry –10°C ~ 46°C 17°C ~ 32°C
21
• The power main switch is
• The circuit breaker is
• Stoppage of electric current
• ON timer is set.
22
To separate using of remote control for each indoor unit in case of 2 air
conditioner are installed nearly.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold
4. Press
Note: 1. Repeat above step to reset Remote
2. Remote Control A has not “A” display.
3. Default setting of Remote Control from
button is pressed once during “Cool” or “Dry” mode, the fan will
continue to run for other 20 minutes, then it will turn off automatically.
This will reduce the moisture in the indoor unit.
3 times within 30 seconds.
OPERATION AND PERFORMANCE
for 3 minutes when suddenly restarted or switched to ON.
operation starts.
temperature, the fan speed is automatically reduced and the outdoor
unit will stop.
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
where it will not be subjected to snow drifts, accumulation of leaves or
other seasonal debris.
normal because the cracking sound may be caused by expansion/
contraction of plastic.
Note: Item 2 to 6 for Heating model
Temp.
Outdoor Temperature
Room
Temperature
TROUBLESHOOTING (CHECK POINT)
The unit does not operate.
turned off.
activated to cut off the power
supply.
Cooling or Heating is abnormally low.
• The fi lters are blocked with dust.
•
The temperature has been set improperly.
• The windows or doors are opened.
• The air inlet or outlet of the outdoor
unit is blocked.
• The fan speed is too low.
• The operation mode is FAN or DRY.
REMOTE CONTROL A-B SELECTION
CHK O
pencil. “00” will be shown on the display.
“00” will disappear and the air conditioner will turn OFF. The Remote
Control B is memorized.
Control to be A.
factory is A.
button on the Remote Control by the tip of the
MODE
during pushing
CHK O
. “B” will show on the display and
EN
ES
FR
IT
DE
PT
PL
CZ
CR
HU
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI
1110250165.indb 3
10/27/09 3:58:51 PM