Toshiba RAS-07S3KHS, RAS-07S3AHS-EE User manual

OWNER’S MANUAL
ENGLISH
RUSSIAN
AIR CONDITIONER (SPLIT TYPE)
For general public use
Indoor unit RAS-07, 10, 13, 18, 24S3KHS-EE
Outdoor unit RAS-07, 10, 13, 18, 24S3AHS-EE
TSB 1110655140_EN_RU.indb 1TSB 1110655140_EN_RU.indb 1 11/20/57 BE 2:05 PM11/20/57 BE 2:05 PM
PRECAUTIONS FOR SAFETY
DANGER
Do not install, repair, open or remove the cover. It may expose you to dangerous
voltages. Ask the dealership or the specialist to do this.
Turning off the power supply will not prevent potential electric shock.
The appliance shall be installed in accordance with national wiring regulation.
Means for disconnection from the supply having a contact separation of at least
3 mm in all poles must be incorporated in the fi xed wiring.
WARNING
Do not expose your body directly to cool air for a long time.
Do not insert your fi nger or any article into the air inlet/outlet.
When an abnormality (burning smell, etc.) occurs, stop the air conditioner and
turn off the circuit breaker.
Installation must be requested from the supplying retail dealership or
professional installation vendors. Installation requires special knowledge and skill. If customers install on their own, it can be a cause of fi re, electric shock, injury or water leakage.
Do not select a location for installation where fl ammable gas may leak. If there
is any gas leakage or accumulation around the unit, it can be a cause of fi re.
Do not turn ON/OFF the circuit breaker or operate buttons with a wet hand. It
may be a cause of electric shock.
Do not disassemble, modify or relocate the unit by yourself. It may become the
cause of fi re, electric shock, or water leakage. For repair or relocation, please request service from the supplying retail dealership or a Toshiba dealership.
Do not select a location for installation where there may be excessive water or
humidity, such as a bathroom. Deter ioration of insulation may be a cause of electric shock or fi re.
When relocating or repairing the unit, please contact the supplying retail
dealership. When there is a kink in the wiring, it may be the cause of electric shock or fi re.
During an error (such as a burning odor, not cooling, or not warming), stop
operating the unit and turn off the circuit breaker. Continuous operation may be a cause of fi re, or electric shock. Please request repair or service from the supplying retail dealership or a Toshiba dealership.
Earth work should be requested from the supplying retail dealership or
professional vendors. Insuffi cient grounding work may be the cause of electric shock. Do not connect the earth wire to a gas pipe, water pipe, lightning conductor, or telephone earth wire.
If the indoor unit piping outlet is exposed due to relocation, close the opening.
Touching internal electrical parts may cause injury or electric shock.
Do not insert any material (metal, paper, or water, etc) into the air outlet or
air intake opening. Fan may be rotating at high speed inside or there are high voltage sections, which may cause an injury or electric shock.
You must use a independent power outlet for the power supply. If a power outlet
other than the independent outlet is used, it may cause a fi re.
When the air-conditioning unit does not cool or warm, there may be a leakage of
refrigerant. Please consult the supplying retail dealership. The refrigerant used in the air-conditioning unit is safe. It will not leak under normal operating conditions but if it leaks into the room and contacts a heat source such as a heater, or stove, it may cause a harmful reaction.
When water or other foreign substances enter the internal parts, stop operating
the unit immediately and turn off the circuit breaker. Operating the unit continuously may cause fi re or electric shock. Please contact the supplying retail dealership for repair.
Do not clean the inside of the air-conditioning unit yourself. Please request
internal cleaning of the air-conditioning unit from the supplying retail dealership. Incorrect cleaning may cause breakage of resin parts or insulation defects of electrical parts, causing water leakage, electric shock or fi re.
Do not damage or modify the power cable. Do not connect the cable midway,
or use a multiple outlet extension cord that is shared by other devices. Failure to do so may cause fi re.
Do not place heavy objects on the power cable, expose it to heat, or pull it. To
do so may cause electrical shock or fi re.
This appliance is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure that they do not play with the
appliance.
Do not use any refrigerant different from the one specifi ed for complement or
replacement. Otherwise, abnormally high pressure may be generated in the refrigeration cycle, which may result in a failure or explosion of the product or an injury to your body.
CAUTION
Check that the circuit breaker is installed correctly. If the circuit breaker is not
properly installed, it may cause an electric shock. To check the installation method, please contact the supplying retail dealership or the professional vendor who installed the unit.
When using the unit in a closed room, or operating with other combustion
appliances, make sure to open a window occasionally for ventilation. Insuffi cient ventilation may cause suffocation due to a lack of oxygen.
Avoid operating for long periods in a high humidity environment (over 80%) such
as with the windows or doors open. There may be condensation on the indoor unit and droplets may fall onto the furniture.
When the unit won’t be used for a long time, turn off the main switch or the
circuit breaker.
It is recommended that maintenance be performed by a specialist when the unit
has been operated for a long time.
At least once a year check if the mounting table of the outdoor unit is damaged
or not. If a damaged state is ignored, the unit may fall or over-turn, causing an injury.
Stand on a sturdy ladder when attaching/detaching the front panel/air fi lter/air
cleaning fi lter. Failure to do so may cause a fall or injury.
Do not stand on the outdoor unit or place anything on the unit. It may be the
cause of injury due to falling or over-turning. Any damage to the unit may cause an electric shock or fi re.
Do not use combustion appliances in the direct fl ow of the air from the air-
conditioning unit. Poor combustion of a combustion appliance may cause suffocation.
Do not place anything around the outdoor unit or allow fallen leaves to
accumulate around it. If there are fallen leaves, small animals could enter and contact internal electrical parts, causing a failure or fi re.
Do not place animals and plants in places where wind from the air-conditioning
unit fl ows directly. It may have a negative infl uence on the animal or plant.
Ensure that drained water is discharged. When the discharging water process
is not suffi cient, water may leak, causing water damage to furniture. To check that the installation method used is correct, please contact the supplying retail dealership or the professional vendor who installed the unit.
Do not place any containers such as a vase containing fl uid on the unit. It might
cause water to enter the unit and deteriorate the electrical insulation, causing an electric shock.
Do not use for special applications such as storage of food or animals, or to
display plants, precision devices, or art objects. Do not use on ships or in other vehicles. It may cause a failure in the air-conditioning unit. In addition, it may damage these items.
Do not place other electrical appliances or furniture under the unit. Water
droplets might fall, causing damage or failure.
When cleaning, you must stop operating the unit and turn off the circuit breaker.
Since the fan inside may be rotating at high speed, it may cause an injury.
Do not wash the main air-conditioning unit with water. It may cause an electric
shock.
After the front panel/air fi lter is cleaned, wipe away any water and allow to dry. If
water remains, it may cause an electric shock.
Once the front panel is removed, do not touch the metal parts of the unit. It may
cause an injury.
Do not touch the air intake section or the aluminum fi ns of the unit. It may cause
injury.
When you hear thunder and there might be a lightning strike, stop operating the
unit and disconnect the circuit breaker. If lightning strikes, it may cause a failure.
Batteries for remote control unit:
- Should be inserted with correct polarity (+) and (–).
- Should not be recharged. Do not use batteries for which the “Recommended usage period” has expired.
-
- Do not keep used batteries inside the remote control unit.
- Do not mix different types of batteries, or mix new batteries with old ones.
- Do not directly solder the batteries.
- Do not short-circuit, disassemble, heat, or throw batteries into a fi re. If batteries are not disposed of correctly, they may burst or be the cause of fl uid leakage, resulting in burns or injuries. If touching the fl uid, wash thoroughly with water. If it touches devices, wipe off to avoid direct contact.
- Do not place within reach of small children. If a battery is swallowed, consult a doctor immediately.
The manufacturer shall not assume any liability for the damage caused by not
observing the description of this manual.
1
INDOOR UNIT DISPLAY
1 TIMER (Yellow) 2 OPERATION (Green) 3 RESET button
TSB 1110655140_EN_RU.indb 1TSB 1110655140_EN_RU.indb 1 11/20/57 BE 2:05 PM11/20/57 BE 2:05 PM
2
PREPARATION BEFORE USE
Preparing Filters
1. Open the air inlet grille and remove the air fi lters.
2. Attach the fi lters. (see detail in the accessory sheet).
Loading Batteries (when use wireless operation.)
1. Remove the slide cover.
2. Insert 2 new batteries (AAA type) following the (+) and (–) positions.
Remote Control Reset
1. Remove the batteries.
2. Press
3. Insert the batter ies.
3
AIR FLOW DIRECTION
Press
1
desired vertical direction.
Press
2
automatically and press again to stop.
For horizontal direction, adjust manually.
3
Note:
• Do not move the louver manually by others.
• The louver may automation positioning by some operation mode.
4
REMOTE CONTROL
1 Infrared signal emitter 2 Start/Stop button 3 Mode select button (MODE) 4 Temperature button (TEMP) 5 Fan speed button (FAN) 6 Swing louver button (SWING) 7 Set louver button (FIX) 8 Off timer button (OFF) 9 High power button (Hi-POWER) ! Economy button (ECO) " Clear button (CLEAR) # Check button (CHECK)
5
AUTOMATIC OPERATION
To automatically select cooling, heating or fan only operation
1. Press
2. Press
3. Press
6
1. Press
2. Press
Cooling: Min. 17°C, Heating: Max. 30°C, Fan Only: No temperature indication
3. Press
MODE
HIGH
COOLING / HEATING / FAN ONLY OPERATION
MODE
FAN
or HIGH .
.
FIX
: Move the louver in the
SWING
: Swing the air
1
3 2 7
9 8 #
: Select A.
: Set the desired temperature.
FAN
: Select AUTO, LOW , LOW+ , MED , MED+ , or
.
: Select Cool , Heat , or Fan only .
: Set the desired temperature.
: Select AUTO, LOW , LOW+ , MED , MED+ ,
4
6 5
! "
7
DRY OPERATION
For dehumidifi cation, a moderate cooling performance is controlled automatically.
1. Press
2. Press : Set the desired temperature.
8
To automatically control room temperature and airfl ow for faster cooling or heating operation (except in DRY and FAN ONLY mode)
Press
9
To automatically control room to save energy (except in DRY and FAN ONLY mode)
MODE
: Select Dry .
Hi-POWER OPERATION
Hi POWER
: Start and stop the operation.
ECO OPERATION
Press : Start and stop the operation.
Note: Cooling operation; the set temperature will increase automatically 1 degree/
hour for 2 hours (maximum 2 degrees increase). For heating operation the set temperature will decrease.
10
TEMPORARY OPERATION
In case of the misplaced or discharged remote control
• Pressing the RESET button, the unit can start or stop without using the remote control.
• Operation mode is set on AUTOMATIC operation, preset temperature is 24°C and fan operation is automatic speed.
11
TIMER OPERATION
Set the timer when the air conditioner is operating.
Setting the OFF timer
Press
1
2
Press for select desired OFF timer. (0.5 - 12 hrs)
Press
3
Press
4
12
AUTO RESTART OPERATION
To automatically restart the air conditioner after the power failure (Power of the unit must be on.)
Setting
1. Press and hold the RESET button on the indoor unit for 3 seconds to set the operation. (3 beep sound and OPERATION lamp blink 5 time/sec for 5 seconds)
2. Press and hold the RESET button on the indoor unit for 3 seconds to cancel the operation. (3 beep sound but OPERATION lamp does not blink)
• In case of ON timer or OFF timer are set, AUTO RESTART OPERATION does not activate.
13
MAINTENANCE
Firstly, turn off the circuit breaker.
Indoor Unit and Remote Control
• Clean the indoor unit and the remote control with a wet cloth when needed.
• No benzine, thinner, polishing powder or chemically-treated duster.
OFF
for enter OFF timer setting.
OFF
for set OFF timer.
OFF
again for cancel OFF timer.
EN
FR
IT
DE
PT
PL
CZ
RU
CR
HU
TR
NL
GR
SV
FI
NO
DK
RO
BG
EE
LV
SK
SI
TSB 1110655140_EN_RU.indb 2TSB 1110655140_EN_RU.indb 2 11/20/57 BE 2:05 PM11/20/57 BE 2:05 PM
Loading...
+ 5 hidden pages