Toshiba RAS-10GKHP-E, RAS-07GA-E, RAS-10GAH-E, RAS-07GKHP-E, RAS-07GAH-E user guide manual

...
SERVICE MANUAL
AIR CONDITIONER
SPLIT WALL TYPE
RAS-10GKHP-E / RAS-10GAH-E RAS-07GKHP-E / RAS-07GAH-E
RAS-10GKP-E / RAS-10GA-E RAS-07GKP-E / RAS-07GA-E
FILE NO. SVM-06037
RAS-10GKPX / RAS-10GAX
RAS-07GKPX / RAS-07GAX
10 Class
07 Class
June, 2006
CONTENTS
1. SPECIFICATIONS
2. CONSTRUCTION VIEWS
2-1 Indoor Unit
2-2 Outdoor Unit (RAS-10GAH-E, RAS-10GA-E, RAS-10GAX, RAS-10GAX-V)
2-3 Outdoor Unit (RAS-07GAH-E, RAS-07GA-E, RAS-07GAX)
3. WIRING DIAGRAM
3-1 RAS-10GKHP-E / RAS-10GAH-E
RAS-07GKHP-E / RAS-07GAH-E
3-2 RAS-10GKP-E / RAS-10GA-E
RAS-07GKP-E / RAS-07GA-E
RAS-10GKPX / RAS-10GAX
3-3
RAS-07GKPX / RAS-07GAX RAS-10GKPX-V / RAS-10GAX-V
4. SPECIFICATION OF ELECTRICAL PARTS
4-1 Indoor Unit (RAS-10GKHP-E, RAS-07GKHP-E) 4-2 Outdoor Unit (RAS-10GAH-E) 4-3 Outdoor Unit (RAS-07GAH-E) 4-4 Indoor Unit (RAS-10GKP-E, RAS-07GKP-E, RAS-10GKPX
RAS-07GKPX, RAS-10GKPX-V) 4-5 Outdoor Unit (RAS-10GA-E, RAS-10GAX, RAS-10GAX-V) 4-6 Outdoor Unit (RAS-07GA-E, RAS-07GAX)
FILE NO. SVM-06037
5. REFRIGERATION CYCLE DIAGRAM
5-1 RAS-10GKHP-E / RAS-10GAH-E 5-2 RAS-07GKHP-E / RAS-07GAH-E 5-3 RAS-10GKP-E / RAS-10GA-E 5-4 RAS-07GKP-E / RAS-07GA-E 5-5 RAS-10GKPX / RAS-10GAX, RAS-10GKPX-V / RAS-10GAX-V 5-6 RAS-07GKPX/ RAS-07GAX
6. CONTROL BLOCK DIAGRAM
6-1 RAS-10GKHP-E / RAS-10GAH-E, RAS-07GKHP-E / RAS-07GAH-E
RAS-07UKHP-E3 / RAS-07UAH-E3
6-2 RAS-10GKP-E / RAS-10GA-E, RAS-07GKP-E / RAS-07GA-E,
RAS-10GKPX / RAS-10GAX, RAS-07GKPX / RAS-07GAX, RAS-10GKPX-V / RAS-10GAX-V
- 1 -
7. OPERATION DESCRIPTION
7-1 Outline of Air Conditioner Control 7-2 Description of Operation Circuit 7-3 Hi POWER Mode 7-4 High-Temperature Limit Control 7-5 Low-Temperature Limit Control 7-6 Defrost Operation 7-7 Current Limit Control 7-8 Auto Restart Function 7-9 Self-Cleaning function 7-10 QUIET Mode 7-10 COMFORT SLEEP mode
8. INSTALLATION PROCEDURE
8-1 Safety Cautions 8-2 Installation Diagram of Indoor and Outdoor Units 8-3 Installation 8-4 Indoor Unit 8-5 Outdoor Unit 8-6 How to Set Remote Control Selector Switch
FILE NO. SVM-06037
8-7 Others
9. TROUBLESHOOTING CHART
9-1 Troubleshooting Procedure 9-2 Basic Check Items 9-3 Primary Judgement 9-4 Self-Diagnosis by Remote Control (Check Code) 9-5 Troubleshooting Flowcharts
9-6 Troubleshooting for Remote Control
10. PART REPLACEMENT
10-1 Indoor Unit 10-2 Outdoor Unit
11. EXPLODED VIEWS AND PARTS LIST
11-1 Indoor Unit (E-Parts Assy) For Europe model 11-2 Indoor Unit (E-Parts Assy) For Asia model 11-3 Indoor Unit 11-4 Outdoor Unit (RAS-10GAH-E) 11-5 Outdoor Unit (RAS-07GAH-E) 11-6 Outdoor Unit (RAS-10GA-E, RAS-10GAX, RAS-10GAX-V) 11-7 Outdoor Unit (RAS-07GA-E, RAS-07GAX)
- 2 -
1. SPECIFICATIONS
FILE NO. SVM-06037
MODEL
RAS-10GKHP-E/ RAS-10GKP-E/ RAS-10GKPX/RAS-10GAX
RAS-10GAH-E RAS-10GA-E RAS-10GKPX-V/RAS-10GAX-V
ITEM Cooling Heating Cooling Cooling
Capacity
Phase 1
Power source V 220 240
Power consumption kW 0.93 0.98 0.84 0.86 0.78 0.82 0.78 0.82 Power factor % 97 94 94 91 98 96 98 96
Running Indoor A 0.15 current Outdoor A 4.38 4.34 4.05 3.92 3.45 3.41 3.45 3.41 Starting current A 19 15 Moisture removal lit/h 1.2 Noise Indoor (H/M/L) dB 39/35/31
Outdoor (220-240V) dB
Refrigerant
Refrigerant control Capillary tube
Interconnection
pipe
Name of refrigerant R-22 Rated amount kg 0.67 0.75
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Connection type Flare connection
Maximum length (One way)
Maximum height difference
220V 240V 220V 240V 220V 240V 220V 240V
kW 2.65 2.70 2.95 3.00 2.60 2.60 2.60 2.60
Hz 50
47
m 10*
m 5
49 47
49
1
44 45
44
45
INDOOR UNIT RAS-10GKHP-E RAS-10GKP-E RAS-10GKPX, RAS-10GKPX-V
Height mm 250
Dimensions Width mm 740
Depth mm 185
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m3/h 540 560 540
Airflow volume Medium fan m3/h 460 520 460
Low fan m3/h 340 400 340
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-10GAH-E RAS-10GA-E RAS-10GAX, RAS-10GAX-V
Height mm 550
Dimensions Width mm 780
Depth mm 185
Net weight kg 31 30
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 1740 1850 1740 1850 1740 1850 1740 1850
Fan motor output W 20
Compressor
Safety device Fuse, Overload relay
Louver type Automatic louver Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 21 ~ 43
Model PH180X1C-4DZDN3
Output W 605
PH150X1C-4DZDN3
605
15 ~ 43
3
FILE NO. SVM-06037
MODEL
RAS-07GKHP-E RAS-07GKP-E RAS-07GKPX
RAS-07GAH-E RAS-07GA-E RAS-07GAX
ITEM Cooling Heating Cooling Cooling
Capacity
Phase 1
Power source V 220 240
Power consumption kW 0.61 0.68 0.54 0.59 0.58 0.62 0.58 0.62 Power factor % 98 97 98 96 98 96 98 96
Running Indoor A 0.15 current Outdoor A 2.69 2.77 2.35 2.40 2.55 2.55 2.55 2.55 Starting current A 14 13
Moisture removal lit/h 0.8 Noise Indoor (H/M/L) dB 38/33/28
Outdoor (220-240V) dB
Refrigerant
Refrigerant control Capillary tube
Interconnection
pipe
Name of refrigerant R-22 Rated amount kg 0.60 0.63
Gas side size mm 9.52
Connection type Flare connection
Liquid side size mm 6.35
Connection type Flare connection
Maximum length (One way)
Maximum height difference
220V 240V 220V 240V 220V 240V 220V 240V
kW 2.00 2.05 2.00 2.05 2.10 2.15 2.10 2.15
Hz 50
44
m 10*
m 5
45 45
46
44 45
1
44
45
INDOOR UNIT RAS-07GKHP-E RAS-07GKP-E RAS-07GKPX
Height mm 250
Dimensions Width mm 740
Depth mm 185
Net weight kg 8
Evaporator type Finned tube
Indoor fan type Cross flow fan
High fan m3/h 490 490 510
Airflow volume Medium fan m3/h 430 450 430
Low fan m3/h 350 370 350
Fan motor output W 20
Air filter Honeycomb woven filter with PP frame
OUTDOOR UNIT RAS-07GAH-E RAS-07GA-E RAS-07GAX
Height mm 530
Dimensions Width mm 660
Depth mm 240
Net weight kg 28 27
Condenser type Finned tube
Outdoor fan type Propeller fan
Airflow volume m3/h 1280 1360 1280 1360 1280 1360 1280 1360
Fan motor output W 20
Compressor
Safety device Fuse, Overload relay
Louver type Automatic louver
Usable outdoor temperature range °C 15 ~ 43 −10 ~ 24 15 ~ 43
Model PH108X1C-4DZDN2
Output W 605
21 ~ 43
4
Note : 1
·
Capacity is based on the following temperature conditions.
FILE NO. SVM-06037
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Condition
Cooling Heating
(DB) 27°C20°C
(WB) 19°C15°C
(DB) 35°C7°C
(WB) 24°C6°C
JIS B8615-1
- 5 -
2. CONSTRUCTION VIEWS
FILE NO. SVM-06037
2-1. Indoor Unit
6
(Flare 9.52)
FILE NO. SVM-06037
2.2. Outdoor Unit (RAS-10GAH-E, RAS-10GA-E, RAS-10GAX, RAS-10GAX-V)
A
109 124
2
-
Ø
11 x 14
(For 8 -
Ø
Ø
Hole
10 anchor bolt)
321
Ø
6 hole
11x14 hole
Ø
B Detail Drawing (Front leg)
600
50
36
321
307
R5.5
R
Ø
15
6 hole
A detail Drawing (Back leg)
28
86
321
Ø
25 Drain outlet
FAN-GUARD
436
Ø
307
36 50
R
15
COVER-PV
Z
290
550
275
321 342
Electrical part cover
Liquid side (Flare 6.35)
Ø
Gas side (Flare 9.52)
Ø
5
4
S
ervice port
Z View
9060090
69
129
84
45 or more
321
100 or more
600
Air intlel
Air outlel
400 or more
Installation dimension
7
600 or more
4x 11 Long holes(For 8- 10 anchor bolt)
Ø
Ø
Ø
2-3. Outdoor Unit (RAS-07GAH-E, RAS-07GA-E, RAS-07GAX)
A
97
A
Detail Drawing (Back Leg)
6 Hole
265
273.5
50 36
660
R 15
R 5.5
530
273.5
420
59.5
Fan guard
25Drain outlet
2-
11x14 hole
8-∅
(for
B
10 anchor bolt)
FILE NO. SVM-06037
B
Detail Drawing (Front Leg)
265
273.5
6 Hole
11x14 Hole
36 50
R 15
660
Cover PV
Z
242
Installation dimension
45 or more
237.5
100 or more
Air outlet
500 660
View
Z
500
Air inlet
400 or more
600 or more
97.5
4x
(11)
56
11x14 Long holes (for 8-∅10 anchor bolt)
126
48
297
54
Service port
(12.5)273.5 (pitch)
Liquid side (Flare
Gas side (Flare
6.35)
9.62)
8
3. WIRING DIAGRAM
3-1. RAS-10GKHP-E / RAS-10GAH-E
RAS-07GKHP-E / RAS-07GAH-E
FILE NO. SVM-06037
BRW
L
BLU
N
GRN & YEL
SINGLE PHASE 220-240V 50/60Hz
BLK
WHI
BLK
P04
CN31
T02
C.T.
1 1
3 3
CN27
CN03
1 1
BLK
2
THERMO
2
BLK
SENSOR (TA)
SG01
DSA
BLK
PINK
1 1
R22
VARISTOR
3
4
RY03
73 C x2
THERMAL FUSE
PINK
2
CN04
2
T6.3A 250VAC
RY01
CN01
2
1
HEAT EXCHANGER
2
1
BLK
BLK
SENSOR (TC)
RY04
CR02
CR01
LOUVER MOTOR
YEL
5 5
R
1
STO
C01
R2
VARI
MAIN P.C. BOARD WP-009
INFRARED RAYS RECEIVE
AND INDICATION PARTS
CN25
BLU
WHI
YEL
YEL
YEL
34
2
1
34
2
1
CN07
DC5V
Voltage Regulator
C02
L01
CR03
135 C
1 1 2 2 3 3 4 4 5 5
AC FAN MOTOR
BLU
CN10
66
321 321
BLU
321 321
C15
BLK
GRY
YEL
BRW
RED
WHI
8 D3
54 8 54 8
BLU
BLU
54 8 54 8
R319
R26
R27
5 5
R25
6
7
6
7
WHI
BLU
BLU
6
7
CN14
6
7
Micro Power Module
DC12V
+
C63
DB01
IC03
3 3
CN11
21 3
1
21 3
1
INDOOR TERMINAL BLOCK
OUTDOOR TERMINAL BLOCK
OVER LOAD RELAY
COMPRESSOR
BLK
BLK
PNK
WHI
BLK
1
(L)2(N)
1
RED
WHI
2
BLK
SOLENOID COIL
RED
RED
CAPACITOR
RED
3
3
BLK
CAPACITOR
FAN MOTOR
BLU
4
4
WHI BLK
9
INDOOR
OUTDOOR
CHASSIS
3.2 RAS-10GKP-E / RAS-10GA-E RAS-07GKP-E / RAS-07GA-E
FILE NO. SVM-06037
BRW
L
BLU
N
GRN & YEL
SINGLE PHASE
220-240V 50/60Hz
BLK
WHI
BLK
P04
CN31
CN03
1 1
BLK
2
THERMO
2
BLK
SENSOR (TA)
SG01
DSA
BLK
PINK
1 1
R22
VARISTOR
3
4
73 C x2
THERMAL FUSE
PINK
2
CN04
2
T6.3A 250VAC
RY01
CN01
2
1
HEAT EXCHANGER
2
1
BLK
BLK
SENSOR (TC)
LOUVER MOTOR
YEL
YEL
YEL
YEL
4 3
2
5
4 3
2
5 1
CN07
R
1
STO
C01
R2
VARI
MAIN P.C. BOARD WP-009
AC FAN MOTOR
WHI
1
L01
135 C
CN25
DC5V
INFRARED RAYS RECEIVE AND INDICATION PARTS
1 2 3 1 2 3
BLU
BLU
1 2 3 1 2 3
Voltage
Regulator
C02
CR03
6
84 5
7
6
84 5
7
BLU
BLU
R26
8 D3
BLU
R319
R25
R27
WHI
BLU
BLU
6
84 5
7
CN14
6
84 5
7
Micro Power
Module
DB01
IC03
C15
6 6
CN10
11 22 33
44
55
BLK
GRY
YEL
BRW
RED
WHI
3
5
3
5
1 1
DC12V
+
C63
CN11
31 2 31 2
INDOOR
TERMINAL
BLOCK
OUTDOOR TERMINAL BLOCK
BLK
BLK
OVERLOAD RELAY
BLK
1
(L)
1
FAN MOTOR
BLK
WHI
2
(N)
2
RED
RED WHI
COMPRESSOR
GRN&YEL
CHASSIS
RED
CAPACITOR
PNK WHI
INDOOR
OUTDOOR
CAPACITOR
10
3-3. RAS-10GKPX / RAS-10GAX
RAS-07GKPX / RAS-07GAX RAS-10GKPX-V / RAS-10GAX-V
FILE NO. SVM-06037
SINGLE PHASE 220-240V 50/60Hz
BRW
BLU
GRN & YEL
BLK
WHI
BLK
P04
CN31
CN03
1 1
BLK
2 2
BLK
SENSOR (TA)
SG01 DSA
BLK
THERMO
PINK
1 1
R22
VARISTOR
3
4
73 °C
THERMAL FUSE
PINK
2
CN04
2
T6.3A 250VAC
RY01
CN01
2
1
HEAT EXCHANGER
2
1
BLK
BLK
SENSOR (TC)
LOUVER MOTOR
YEL
YEL
YEL
YEL
34
2
5
34
2
5
CN07
TOR IS
C01
R
R21
VA
MAIN P.C. BOARD WP-009
AC FAN MOTOR
WHI
1 1
L01
INFRARED RAYS RECEIVE
AND INDICATION PARTS
CN25
321 321
BLU
BLU
BLU
BLU
321 321
DC5V
Voltage
Regulator
C02
R26
CR03
D38
C15
1 1 2 2 3 3 4 4 5 5
66
CN10
BLK
GRY
YEL
BRW
RED
WHI
135 °C
6
54 8
7
6
54 8
7
BLU
BLU
BLU
6
54 8
7
6
54 8
7
Micro
Power
Module
R319
R25
IC03
R27
3
5
3
5
WHI
DB01
CN14
DC12V
1 1
+
C63
CN11
21 3 21 3
INDOOR TERMINAL BLOCK
INDOOR TERMINAL BLOCK
OUTDOOR TERMINAL
BLOCK
BLK
BLK
OVERLOAD RELAY
BLK
1
(L)
WHI
2
RED
COMPRESSOR
BLK
1
FAN MOTOR
2
(N)
RED WHI
GRN&YEL
CHASSIS
RED
CAPACITOR
PNK WHI
INDOOR
OUTDOOR
CAPACITOR
11
FILE NO. SVM-06037
4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-10GKHP-E, RAS-07GKHP-E)
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4B AC Motor with 135 °C thermo fuse 2 Thermo sensor (TA-sensor) 10k at 25 C 3 Micro power module (M01) RM1260V 4 Microcontroller unit (IC30) TMP87CM40AFG-6G61 5 Heat exchanger sensor
(TC-sensor) 6 Line filter (L01) LC*SS11V-06270 27mH, 600mA 7 Bridge rectifier (DB01) D3SBA60 4A, 600 V
8 Capacitor (C63) EKMH401VSN470MP20S 47mF, 400 V
9 Fuse (F01) BET6.3A 6.3A, 250VAC
10 Varistor (R21, R22) TND15G-561KB0SLAA0 560 V 11 Resistor (R319) RF-2TK5R6 5.6 , 2 W 12 Louver motor MP24ZT 12VDC 13 Relay (Comp., RY01) G4A-1A-E Rating 20A/AC250 V, 12VDC 14 Relay (Fan, RY03) G5NB-1A Rating 3A/AC250 V, 12VDC 15 Relay (Solenoide, RY04) G5NB-1A Rating 3A/AC250 V, 12VDC
m
W
W
10k at 25 C
W
°
°
4-2. Outdoor Unit (RAS-10GAH-E)
No.
1 Compressor PH180X1C-4DZDN3 Winding resistance ( ) C-R C-S
2 Fan motor (for outdoor) Winding resistance ( ) Red-Black White-Black
3
4
5 Overload relay JMRA99208-9102 U/T : 4.2A (80°
Parts name Type Specifications
Output (Rated) 1000 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
W
°
(at 20 C) 3.33 3.78 Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
W
C), OPEN :
Running capacitor (for fan motor)
Running capacitor (for compressor)
SKF-240-20B
(at 20°C
DS451155NPQB AC 450 V ~, 1.5mF
RS44B256U0213S AC 440 V ~, 25mF
235.2 260.1
135±5°C, CLOSE : 69±11°C
- 12 -
FILE NO. SVM-06037
4-3. Outdoor Unit (RAS-07GAH-E)
No. Parts name Type Specifications
Output (Rated) 605W, 2poles, 1 phase, 220 240V, 50Hz
1 Compressor PH108X1C-4DZDN2 Winding resistance () C-R C-S
(at 20°C) 4.84 4.40
Output (Rated) 20W, 6poles, 1 phase, 220 240V, 50Hz
2 Fan motor (for outdoor)
Running capacitor
3
(for fan motor)
Running capacitor
4
(for compressor)
5 Overload relay
DS451155NPQB AC 450V ~, 1.5 F
JMRA99208-9102
SKF-240-20B
RS44B256U0213S AC 440V~, 25 F
Winding resistance () Red-Black White-Black
(at 20°C)
m
m
U/T: 4.2A (80°C), OPEN: 135±5°C, CLOSE: 69±11°C
235.2
260.1
4-4. Indoor Unit (RAS-10GKP-E, RAS-07GKP-E, RAS-10GKPX,
RAS-07GKPX, RAS-10GKPX-V)
No. Parts name Type Specifications
1 Fan motor (for indoor) MMF-240-20-4B AC Motor with 135 C thermo fuse 2 Thermo sensor (TA-sensor) 10k at 25 C 3 Micro power module (M01) 4 Microcontroller unit (IC30) TMP87CM40AFG-6G61 5 Heat exchanger sensor
(TC-sensor)
6 Line filter (L01) LC*SS11V-06270 27mH, 600mA 7 Bridge rectifier (DB01) D3SBA60 4A, 600 V 8 Capacitor (C63) EKMH401VSN470MP20S 47mF, 400 V 9 Fuse (F01) BET6.3A 6.3A, 250VAC
10 Varistor (R21, R22) TND15G-561KB0SLAA0 560 V 12 Louver motor MP24ZT 12VDC 13 Relay (Comp., RY01) G4A-1A-E Rating 25A/AC250 V, 3~48VDC
m
RM1260V
W
10k at 25 C
W
°
°
°
- 13 -
4-5. Outdoor Unit (RAS-10GA-E, RAS-10GAX, RAS-10GAX-V)
FILE NO. SVM-06037
No.
1 Compressor PH150X1C-4DZDN3 Winding resistance ( ) C-R C-S
2 Fan motor (for outdoor) Winding resistance ( ) Red-Black White-Black
3
4
5 Overload relay LPAP960B U/T : 6.1A (80°
Parts name Type Specifications
Output (Rated) 1000 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
W
°
(at 20 C) 3.33 3.78 Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
W
C), OPEN :
Running capacitor (for fan motor)
Running capacitor (for compressor)
SKF-240-20B
(at 20°C
DS451155NPQB AC 450 V ~, 1.5mF
RS44B306U0214S AC 440 V ~, 30mF
235.2 260.1
135±5°C, CLOSE : 75±11°C
4-6. Outdoor Unit (RAS-07GA-E, RAS-07GAX)
No.
1 Compressor PH108X1C-4DZDN2 Winding resistance ( ) C-R C-S
2 Fan motor (for outdoor) Winding resistance ( ) Red-Black White-Black
3
4
Parts name Type Specifications
Output (Rated) 650 W, 2 poles, 1 phase, 220 - 240 V, 50Hz
W
°
(at 20 C) 4.84 4.40 Output (Rated) 20 W, 6 poles, 1 phase, 220 - 240 V, 50Hz
W
Running capacitor (for fan motor)
Running capacitor (for compressor)
SKF-240-20B
(at 20°C
DS451155NPQB AC 450 V ~, 1.5mF
RS44B256U0213S AC 440 V ~, 25mF
235.2 260.1
5 Overload relay JMRA99208-9102 U/T : 4.2A (80°
- 14 -
C), OPEN :
135±5°C, CLOSE : 69±11°C
5. REFRIGERATION CYCLE DIAGRAM
5-1. RAS-10GKHP-E / RAS-10GAH-E
FILE NO. SVM-06037
Indoor unit
Cooling
0.39 m (Connecting pipe) Æ9.52
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Heating
Heating
P
Packed valve
(Æ9.52)
Heating
4-way valve
Cooling
Compressor
PH180X1C-4DZDN3
Accumulator
Heat exchanger
Cross flow fan
T1
0.49 m (Connecting pipe) Æ6.35
Packed valve
(Æ6.35)
Capillary tube
Æ1.5 x 700l
Heat exchanger
Refrigerant R22 : 0.67 kg.
Cooling Heating
Propeller fan Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standar d
pressure
(MPaG)
P
Surface temp. of heat
exchanger inter changing
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 1.60 42.0 High 20/15 7/6
Heating Overload*1 2.14 ~ 2.24 50.0 ~ 56.0 Low 27/- 24/18
Low temperature 1.30 32.0 High 20/-
-10/-10
Standard 0.44 10.0 High 27/19 35/24
Cooling Overload 0.61 15.0 High 32/23 43/26
Low temperature 0.39 2.0 Low 21/15 21/15
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
*1 · During heating overload operation, a value for the high temperature limit control operation is included.
- 15 -
5-2. RAS-07GKHP-E / RAS-07GAH-E
FILE NO. SVM-06037
Indoor unit
Cooling
0.39m (Connecting pipe) 9.52
O.D.:9.52mm O.D.:6.35mm
Cooling
Heating
Heating
P
Packed valve
(9.52)
Heating
4-way valve
Cooling
Compressor
PH108X1C-4DZDN2
Accumulator
Heat exchanger
Cross flow fan
T1
0.49m (Connecting pipe) 6.35
Packed valve
(6.35)
Capillary tube
1.0x900S
(2 pcs.)
Heat exchanger
Refrigerant R-22 : 0.60 kg.
Fan speed
(indoor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
Cooling Heating
50Hz
Propeller fan Outdoor unit
Standard
pressure P
(MPaG)
Mark( )means check points of Gas Leak.
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Standard 1.33 36.0 High 20/– 7/6
Heating Overload 1.95 50.0 Low 27/– 24/18
Low temperature 1.05 31.0 High 20/––10/–10 Standard 0.57 12.0 High 27/19 35/24
Cooling Overload 0.68 18.0 High 32/23 43/26
Low temperature 0.42 2.0 Low 21/15 21/15
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
16
5-3. RAS-10GKP-E / RAS-10GA-E
FILE NO. SVM-06037
Indoor unit
Cooling
0.39 m (Connecting pipe) Æ9.52
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Packed valve
Cooling
P
(Æ9.52)
Compressor
PH150X1C-4DZDN3
Heat exchanger
Cross flow fan
T1
0.49 m (Connecting pipe) Æ6.35
Packed valve
(Æ6.35)
Capillary tube
Æ1.5 x 1200l
Heat exchanger
Refrigerant R22 : 0.75 kg.
Cooling
Propeller fan Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.50 11.0 High 27/19 35/24
Cooling Overload 0.60 16.0 High 32/23 43/26
Low temperature 0.45 2.0 Low 21/15 21/15
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
- 17 -
5-4. RAS-07GKP-E / RAS-07GA-E
FILE NO. SVM-06037
Indoor unit
Cooling
0.39m (Connecting pipe) 9.52
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
Cooling
P
(9.52)
Compressor
PH108X1C-4DZDN2
Heat exchanger
Cross flow fan
T1
0.49m (Connecting pipe) 6.35
Packed valve
(6.35)
Capillary tube
1.2x600S
Heat exchanger
Refrigerant R-22 : 0.63 kg.
Fan speed
(indoor)
50Hz
Cooling
Propeller fan Outdoor unit
Standard
pressure P
(MPaG)
Mark( )means check points of Gas Leak.
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Standard 0.55 12.0 High 27/19 35/24
Cooling
Overload 0.66 16.0 High 32/23 43/26 Low temperature 0.42 2.0 Low 21/15 21/15
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
18
5-5. RAS-10GKPX / RAS-10GAX
RAS-10GKPX-V / RAS-10GAX-V
FILE NO. SVM-06037
Indoor unit
Cooling
0.39 m (Connecting pipe) Æ9.52
O.D.:9.52 mm O.D.:6.35 mm
Cooling
Packed valve
Cooling
P
(Æ9.52)
Compressor
PH150X1C-4DZDN3
Heat exchanger
Cross flow fan
T1
0.49 m (Connecting pipe) Æ6.35
Packed valve
(Æ6.35)
Capillary tube
Æ1.5 x 1200l
Heat exchanger
Refrigerant R22 : 0.75 kg.
Cooling
Propeller fan Outdoor unit
Mark ( ) means check points of Gas Leak.
Ambient temp.
50Hz
Standard
pressure
(MPaG)
P
Surface temp. of heat
exchanger interchanging
pipe
T1
(°C)
Fan speed
(indoor)
conditions DB/WB
(°C)
Indoor Outdoor
Standard 0.50 11.0 High 27/19 35/24
Cooling Overload 0.60 16.0 High 32/23 43/26
Low temperature 0.45 2.0 Low 21/15 21/15
Note
· Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
- 19 -
5-6. RAS-07GKPX / RAS-07GAX
FILE NO. SVM-06037
Indoor unit
Cooling
0.39m (Connecting pipe) 9.52
O.D.:9.52mm O.D.:6.35mm
Cooling
Packed valve
Cooling
P
(9.52)
Compressor
PH108X1C-4DZDN2
Heat exchanger
Cross flow fan
T1
0.49m (Connecting pipe) 6.35
Packed valve
(6.35)
Capillary tube
1.2x600S
Heat exchanger
Refrigerant R-22 : 0.63 kg.
Fan speed
(indoor)
50Hz
Cooling
Propeller fan Outdoor unit
Standard
pressure P
(MPaG)
Mark( )means check points of Gas Leak.
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)
Standard 0.55 12.0 High 27/19 35/24
Cooling
Overload 0.66 16.0 High 32/23 43/26 Low temperature 0.42 2.0 Low 21/15 21/15
Note :
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor Outdoor
20
FILE NO. SVM-06037
6. CONTROL BLOCK DIAGRAM
6-1. RAS-10GKHP-E / RAS-10GAH-E, RAS-07GKHP-E / RAS-07GAH-E
Heat Exchange sensor
Thermo. Sensor
Current Sensor
(Compressor Current)
Infrared Rays Signal Reciver
Main Unit Control Panel
Functions
 Louver Control
3-minutes Delay at Restart
for Compressor
Initiallizing Circuit
Clock Frequency Oscillator Circuit
Power Supply
Circuit
Noise Filter Relay Driver, Louver Driver
Motor Revolution Control
Processing
(Temperature Processing)
Timer
Compressor
ON/OFF
Signal
Outdoor Fan
M.C.U.
ON/OFF
Signal
4-Way Valve
ON/OFF
Signal
Operation
Display
Timer
Display
Indoor Fan
Motor
Louver
ON/OFF
Signal
Louver
Motor
220-240 V~, 50Hz
REMOTE CONTROL
Relay
RY01
Compressor 4-Way Valve
Remote Control
Operation (START/STOP)
Operation Mode Selection
AUTO, COOL, DRY, HEAT, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Relay
Outdoor Fan Motor
RY03
Infrared Rays
Relay
RY04
Hi power
Filter Reset
21
6-2. RAS-10GKP-E / RAS-10GA-E, RAS-07GKP-E / RAS-07GA-E,
RAS-10GKPX / RAS-10GAX, RAS-07GKPX / RAS-07GAX, RAS-10GKPX-V / RAS-10GAX-V
Main Unit Control Panel M.C.U.
Heat Exchange sensor
Functions
FILE NO. SVM-06037
Operation
Display
Thermo. Sensor
Infrared Rays Signal Reciver
 Louver Control
3-minutes Delay at Restart
for Compressor
Initiallizing Circuit
Clock Frequency Oscillator Circuit
Power Supply
Circuit
Noise Filter Relay Driver, Louver Driver
Motor Revolution Control
Processing
(Temperature Processing)
Timer
Compressor
ON/OFF
Signal
Relay
RY01
Indoor Fan
Motor
Louver
ON/OFF
Signal
Louver
Motor
220-240 V~, 50Hz
REMOTE CONTROL
Compressor, Outdoor Fan Motor
Infrared Rays
Remote Control
Operation (START/STOP)
Operation Mode Selection
AUTO, COOL, DRY, FAN ONLY
Temperature Setting
Fan Speed Selection
ON TIMER Setting
OFF TIMER Setting
Louver Auto Swing
Louver Direction Setting
ECO
Hi power
Filter Reset
- 22 -
7. OPERATION DESCRIPTION
FILE NO. SVM-06037
7-1. Outline of Air Conditioner Control
This is a fixed capacity type air conditioner, which uses AC motor for an indoor fan. The AC motor drive circuit is mounted in the indoor unit. And electrical parts which driving the compressor and the outdoor fan motor, are mounted in the outdoor unit.
The air conditioner is controlled by the controller mounted in the indoor unit. The controller operates all components based on the commands trVansmitted from the remote control and the f is as fPollo
The temper
ature measurement at the air inlet of the indoor heat e temperature sensor
The temper
heat e
ature measurement at the indoor
xchanger b
temperature sensor
Indoor f Louv LED displa Outdoor f
an motor oper
er motor control
y control
an motor oper
4-WAYS-VALVE operation control (Heat pump model only)
Compressor oper
Receiving the inf status and judging the inf indication of errors
eedbac
k data of the sensor
xchanger b.y the indoor
y the indoor heat earxchanger
ation control
ation control
ation control
mation of the oper
ation
mation or the
7-1-1. Louver control
(1)
er
tical air flo
osition of vw:er•itcal air flo
w louv
er
w louv
er is automatically controlled according to the operation mode Besides arbitr The louv stored in the microcontroller automatically set at the stored position f oper
, position of v•er
ily set b
y pressing [FIX] b•utton.
er position which is set b
ation.
tical air flo
w louv
y [FIX] b•utton is
, and the louv•er is
er can be
or the ne•xt
(2)• Swing
If [SWING] b is in oper s
winging.
utton is pressed when the indoor unit
ation, the vorer
tical air flo
w louv
er starorts
When [SWING] button is pressed again,
it stops swinging.
7-1-2. Indoor fan control (AC Fan motor)
(1) The indoor fan is operated by the stepless speed
change AC motor.
(2) For air flow level, speed of the indoor fan motor is
controlled in five steps (LOW, LOW
+
, MED, MED and HIGH). If AUTO mode is selected, the fan motor speed is automatically controlled by the difference between the preset temperature and the room temperature.
LOW
=
LOW+MED
+
2
MED+=
MED+HIGH
2
+
OPERATION
MODE
RAS-07GK Series
RAS-07GKH Series
Model
RAS-10GK Series
RAS-10GKH Series
Table 7-1-1
Cooling
Fan only
Dry
Heat
rpm
Air flow volume (m3/h)
rpm
Air flow volume (m3/h)
rpm
Air flow volume (m3/h)
rpm
Air flow volume (m3/h)
UH H M L L- UL SL
UH H M L L- UL SL
1300
540
1200
490
1350
560 390
1350 980
560 390
- 23 -
FAN TAP
HM LL-
MLL-ULSL
1250 1120 1070 900 800 750 700 650 500
510 450 430 350 300 270 250 220 150
1120 1070 900 800 750 700 650 500
450 430 350 300 270 250 220 150
1300 1180 1140 1000 900 800 750 700 550
540 500 460 400 350 300 270 250 180
1300 1180 1140 1000 900 800 750 700 550
540 500 460 400 350 300 270 250 180
950
370
950
370
980
FILE NO. SVM-06037
7-2. Description of Operation Circuit
(1) When turning on the breaker, the operation lamp
blinks. This means that the power supply is on.
(2) When pressing [ ] button on the remote control,
receiving beep sounds from the indoor unit, and the next operation is performed together with opening the vertical air flow louver.
(3) Once the operation mode is set, it is memorized in
the microcontroller so that the previous operation can be effected thereafter simply by pressing [ ] button.
7-2-1. Fan only operation
([MODE] button on the remote control is set to the fan only operation.)
(1) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-1. When [FAN] button is set to LOW, LOW HIGH, the motor operates with a constant air flow.
°C
+3
+2.5
+2
-
+1.5
+1
+0.5
(Room temp.) (Preset temp.)
Preset temp.
0
(Preset temp.: 22°C)
NOTE :
*1: The values marked with *1 are calculated and
controlled by the difference in motor speed between M+ and L-.
(2) The Hi POWER, ECO and COMFORT SLEEP
operation cannot be set.
Fig. 7-2-1 Setting of air flow [FAN:AUTO]
+
, MED, MED+ or
M+
*1
*1
*1
-
L
7-2-2. Cooling operation
([MODE] button on the remote control is set to the cooling operation.)
(1) The compressor, 4-way valve, outdoor fan and
operation display on the remote control are controlled as shown in Fig. 7-2-2.
°C
ON ON
OFF OFF OFF ON
4-way valve
Compressor
Outdoor fan
OPERATION
-
(Room temp.) (Preset temp.)
Preset temp.
0.5
0
Fig. 7-2-2
(2) When [FAN] button is set to AUTO, the indoor fan
motor operates as shown in Fig. 7-2-3. When [FAN] button is set to LOW, LOW
+
, MED, MED+ or
HIGH, the motor operates with a constant air flow.
°C
(Preset temp.)
(Room temp.)
Preset temp.
+3
+2.5
+2
+1.5
+1
+0.5
0
-0.5
M+
*1
*1
*1
L
-
NOTE :
*1: The values marked with *1 are calculated and
controlled by the difference in motor speed between M+ and L-.
display
- 24 -
Fig. 7-2-3 Setting of air flow [FAN:AUTO]