1. Make sure that this instruction manual is delivered to the end user of the inverter.
2. Read this manual before first using the communications function, and keep it handy as a
reference for maintenance and inspections.
3. All information contained in this manual are subject to change without notice. Please
confirm the latest information on our web site “www.inverter.co.jp”.
Notice
Page 2
Safety precautions
On the inverter and in its instruction manual, important information is contained for preventing injuries to users,
damages to assets, and for proper use of the inverter.
Read the instruction manual attached to the inverter along with this instruction manual to completely
understand the safety precautions, the symbols and indications shown belo w. Please adhere to the contents of
these manuals at all times.
Explanation of markings
Marking Meaning of marking
Warning
Caution
(*1) Such things as injury, burns or shock that will not require hospitalization or long periods of
outpatient treatment.
(*2) Physical property damage refers to wide-ranging damage to assets and material s.
Meanings of symbols
Marking Meaning of marking
Indicates prohibition (Don't do it).
What is prohibited will be described in or near the symbol in either text or picture form.
Indicates an instruction that must be followed.
Detailed instructions are described in illustrations and text in or near the symbol.
-Indicates warning.
What is warned will be described in or near the symbol in either text or picture form.
-Indicates caution.
What the caution should be applied to will be described in or near the symbol in either text
or picture form.
Indicates that errors in operation may lead to death or serious injury.
Indicates that errors in operation may lead to injury (*1) to people or that these
errors may cause damage to physical property. (*2)
E6581680
1
Page 3
Limitation of use
Safety precaution
Never use this unit with any inverter other than TOSVERT series inverters. Doing so may cause an accident.
Handling in general
E6581680
Never
Disassemble
Prohibited
Mandatory
action
Never disassemble, modify or repair the product.
Disassembling the product may cause electric shocks, fire or injuries.
For repairs, call your sales/repair agency.
Do not put or insert foreign objects such as waste cable, bars, or wires into the product.
It may lead to electric shocks or fire.
Do not splash water over the product, and do not wipe the body with a wet cloth.
It may lead to electric shocks or fire.
Turn off input power before wiring.
Wait at least 15 minutes and check to make sure that the charge lamp (on the inverter unit) is no
longer lit.
Turn off the power immediately in case of any abnormalities such as smoke, smell or abnormal
noise.
Neglect of these conditions may lead to fire.
For repairs, call your sales/repair agency.
Transportation and usage
Prohibited
Mandatory
action
Do not install or operate the inverter if it is damaged or any part of it is missing.
Operating a defective inverter may lead to electric shocks or fire.
For repairs, call your sales/repair agency.
Do not put any flammable material near the product.
It may catch fire due to the product sparking in the case of a malfunction.
Do not connect a LAN cable o r telephone modular cable to Parameter writer.
Doing so may cause a failure or accident.
Electrical construction work must be done by a qualified expert.
Connection of input power by someone who does not have expert knowledge may result in fire
or electric shock.
Operate under the environmenta l conditions prescribed in the instruction manual.
Operations under any other conditions may result in malfunction.
An emergency stop inverter must be installed that fits with system specifications
(e.g. shut off input power then engage mechanical brake).
Operation cannot be stopped immediately by the inverter alone, thus risking an accident or
injury.
Use the attached cable for connecting this option al unit.
The use of any other option may result in an accident.
Warning
Warning
Prohibited
Caution
Do not use the product in any place subject to vibrations or it may fall.
This may lead to the product falling and causing injury.
Do not use nickel-cadmium rechargeable battery or manganese battery.
This may lead to
Do not use different type of battery together, or new battery and reuse one together
This may lead to
liquid spill and fire.
liquid spill and fire.
2
Page 4
Operations
Prohibited
Mandatory
action
Mandatory
action
E6581680
Warning
Do not apply a dropping shock or other physical shocks.
Otherwise, damage or malfunction will result.
Do not pull on the cable and connector
It may cause damage or error.
Do not bring any regions of your bod y into contact with the inverter terminals when power is
supplied to the inverter. Contact during the power-on status of the inverter can result in electric
shock.
Use an additional s afety inverter with your inverter or s ystem to prevent a serious accident due
to the unit malfunctions. Usage without an additional safety inverter may cause an accident.
Make sure to check that the param eter data from this product is not accidently copied to the
wrong inverter.
Usage with wrong parameter may result in an accident.
Caution
▼ Set up “Communication time-out (f803, f804 and f808)” (see the i nverter instruction
manual for details) to stop the inverter when Parameter writer is deactivated by an unusual
event such as tripping, an operating error, power outage, failure, etc. Deactivated Parameter
writer may cause an accident, if the “Communication time-out” is not properly set up.
Please back up the data used with this unit.
The stored data might be lost according to using condition of the SD card.
Please be forewarned that our company cannot make compensation for the damage depend on
the loss of the stored data.
Disposal
Mandatory
action
If you dispose off this unit, have it done by a specialist in industrial waste disposa l*. Improper
disposal may result in explosion of capacitors or produce noxious gases, resulting in injury.
(*) Persons who specialize in the processing of waste and known as “Industrial Waste Product
Collectors and Transporters” or “Industrial Waste Disposal Persons.” If the collection, transport
and disposal of industrial waste is done by someone who is not licensed for that job, it is a
punishable violation of the law (Laws in regard to cleaning and processing of waste materials).
Notes on operation
Avoid using in a place where ambient temperature or/and humidity change sharply. Keep the transmission cable separate from the power cable of the inverter to prevent the
inverter from malfunctioning due to electromagnetic noise.
The integrity of data storage is guaranteed for up to 5 years. The operating life of the data storage inverter is 1000 0 operations.
Do not execute more than 10000 writing operations.
Do not turn off power or remove the connection cable between the inverter and Parameter writer
or take off SD card while a copying operation is in progress. If the inverter power is turned off or
the connection cable is removed while parameters are being copied, data cannot be written
correctly.
Do not copy data from Parameter writer to inverter and inverter to Parameter writer while the
inverter is running. Some of the parameters cannot be written when the inverter is in operation.
When a copying operation is execute d between two inverters with different capacities, some of
the parameters that vary with the capacity of the inverters will also be copied. T herefore, when
copying the parameters between inverters with different capacities or voltage class, the type
information parameters of the inverter should always be initializ ed. See the inverter instruction
manual on how to initialize their parameters.
Thank you for purchasing
Before using Parameter writer, carefully read this instruction manual in order to completely and correctly utilize
Parameter writer’s excellent performance.
After reading this instruction manual, please keep it handy for future reference.
1. Receive and inspect the Parameter writer
Check that the reference printed on the label is the same as that on the purchase order. Remove the
Parameter writer from its packaging and check that it has not been damaged in transit.
2. Connect the Parameter writer (see chapter 4)
- To a PC
Parameter writer (PWU003Z) for TOSVERT series inverters.
- To an inverter
3. Copy inverter configurations (see chapter 5)
- Load a configuration onto the Parameter writer
- Transfer a configuration to an inverter
- Transfer a configuration to several inverters (Quick Store)
4. Parameter writer menus (see chapter 6)
5
Page 7
E6581680
2. Introduction
The Parameter writer “PWU003Z” is a standalone tool for transferring configuration files to inverters with their power on
or off.
•The Parameter writer is used to set inverter parameters by loading a configuration file onto the inverter(s).
(Inverters must have the same reference. If the reference is not the same, the fault occurs before the data is
transfered.). The parameters can be set with them before they are powered up.
Duplicating or generating configuration files
A) The inverter's configuration file is copied to the Parameter writer's SD card. See the procedur e on section 5.1.
B) The configuration file is generated by PCM software then transferred to the Parameter writer's SD card. See the
procedure on section
1) The user selects and then transfers the configuration file from the Parameter writer to the inverter. See the proced ure
on section
2) Once the initial transfer is complete, the user can use Quick Store mode, which allows the Parameter writer to load the
same update file on several inverters in succession. (See section
All representations of the VF-nC3 inverter throughout this document are given by way of example only t o symbolize an
inverter.
All bold text in the manual (e.g. "Main menu / Action") corresponds to the messages displayed on the Parameter writer
screen.
5.2.
5.1.
5.3)
6
Page 8
3. Receiptof theParameter writer
(5)
(4)
(7)
E6581680
(1)
(8)
(2)
(3)
(6)
Product reference:
Check that the product reference printed on the label is the same as that on the delivery note. This should also
correspond with the number on the purchase order.
Contents of the Parameter writer box (PWU003Z)
Check that the Parameter writer box contains the following:
(1) Parameter writer
(2) SD card
(3) Standard USB type A to Mini-B cable
(4) RJ45 (RJ45/RJ45) cable(Length: 1m)
(5) Carry case
(6) User’s manual (Japanese and English)
(7) Impact resistant cover
(8) Wrist strap
7
Page 9
(
)
3.1. Presentation
Approximate weight
250 g (including batteries)
65
TOSHIBA
ENT
ESC
181.5
Figure 1
27.4
E6581680
mm
8
Page 10
A
A
3.2. Description
E6581680
B
F
E
H
J
K
G
TOSHIB
ENT
ESC
C
I
D
L
M
Figure 2
Letter Description Comments
The connection between the Parameter writer (USB
A Mini-B USB connector
Mini-B type) and the PC (USB type A) is via a 1 m (3.28
feet) USB type A to Mini-B cable.
The connection between the Parameter writer and the
B
RJ 45 connector
inverter is via a RJ45 cable to load and transfer
configuration files or updated application.
C
D
E
F
G
H
RJ11 connector with label cover
SD card slot
Battery compartment
Power ON/OFF button
Quick Store key
Screen
For factory use only.
The SD card receives and stores the files. One SD card is
supplied with the Parameter writer.
It can take 4 normal batteries and rechargeable batteries.
Press for 2 seconds to turn the tool on or off.
Press this key to transfer data from the Parameter writer
to the inverter after an initial transfer in Quick store mode.
The screen comprises 2 lines of 16 characters.
I
J
K
L
M
ESC key
ENT key
Up arrow key
Down arrow key
Holes
Returns to the previous screen.
Confirms the parameter selection or cancels messages.
For menu navigation.
For menu navigation.
For wrist strap
9
Page 11
E6581680
Data storage
One SD card is supplied with the Parameter writer. Any standard SD card and SDHC card are compatible with the
Parameter writer. (SD card is used in this instruction manual for
The SD card format must be FAT32.
Language
The menus are in English, Japanese, Spanish, German, Italian and French. (Default language is set to English)
Power supplies
Two kinds of batteries are available for powering the Parameter writer:
• 4 x LR6 (AA) alkaline batteries (batteries not attched)
• NiMH rechargeable batteries (batteries and charger not attched)
Battery life
Depending on the type of batteries used, the Parameter writer can transfer up to 300 configuration files.
Power save feature
To prolong battery life, a sleep mode is activated within a programmable time delay; the Parameter writer is reactivated
by pressing the ON/OFF button. (See the display parameters menu on section
inverter can also help conserve battery power, as the power supply from the connected inverter takes over from the
batteries.
explanation)
6.9.) Connection to a powered-up PC or
Mandatory
action
Do not use nickel-cadmium rechargeable battery or manganese battery.
This may lead to
It is not possible occasionally to read according to the kind of the SD card and record condition.
It is not warrantable operati on and the power supply for all SD cards.
The specificati on of the SD card might be changed for reasons of manufacturer’s own.
It is not possible occasionally to operate normally according to the changes.
Even if it is the same type-form, the specification might be different in each selling area
according to the SD card.
The data file recorde d e xcept the specified format might not to be able to read normally and not
displayed the file name.
The SD card with the security function cannot be used. The described specification might change without notice.
liquid spill and fire.
Caution
10
Page 12
4. Connecting the Parameter writer
This section describes the various ways of connecting the Parameter writer.
Default language is set to English. Refer to section 6.9 and change the language setting, according to need.
4.1. Connection to a PC
There are two ways of storing files on the SD card:
-Insert the SD card in the Parameter writer and connect the Parameter writer to the PC via the standard USB
type A to Mini-B cable (see Figure 3)
OR
-Insert the SD card in the SD card reader on the PC (see Figure 4)
E6581680
For both these methods, the SD card is recognized as an external storage device. T he SD card operates in Windows
operating system explorer using the same copy/paste actions as an y standard external storage media. (OS: Windows
XP/Vista/7 operating system)
Note:
•Windows is the registered trademark of Microsoft Corporation in U.S.A. and other countries.
•The PC must be on and operational before connecting the Parameter writer to avoid an incorrect start up of the PC.
•The SD card must not be removed when the Parameter writer is on and a transfer is in progress. Otherwise, data on
the SD card may be lost.
•The file name length is 255 letters maximum.
•The number of files that can be saved in the SD card is up to 65535 or less.
(N.B. Too many files cause slow key operation response and display. Number of files should be little.)
•The following priority rules come into play when the Parameter writer is connected to a PC:
-If no transfer is in progress between the Parameter writer and the drive, the connection to the inverter is
ignored and the Parameter writer is detected by the PC.
-If a transfer is in progress between the Parameter writer and the inverter, the user has to wait until the transfer
is complete. The Parameter writer must then be reconnected so the PC can detect it.
Source of configuration files
-If a inverter's configuration is to be duplicated, it is copied to another inverter via the Parameter writer. See
"Loading a configuration from inverter" on section
5.1 and "Configuration transfers" on section 5.2 and 5.3.
11
Page 13
E6581680
4.2. Connection to an inverter
Parameter files can be transferred to the inverter in whichever A and B condition.
A. When the inverter is off, the Parameter writer is powered
B. When the inverter is on, the Parameter writer is powered by the inverter via
the RJ45 cable.
Connect the Parameter writer to the inverter as following procedures
A.
1. Insert the Parameter writer's communication cable into the inverter's RJ45 comm unication port. Refer to the inverter's
installation manual for more information about how to perform this task.
2. Perform the desired transfer.
3. Remove the Parameter writer communication cable from the inverter.
B.
1. Remove all power from the inverter and all enclosures housing the inverter and wait more than 15 minutes and more
to allow the DC bus of the inverter to discharge.
2. Insert the Parameter writer's communication cable into the inverter's RJ45 comm unication port. Refer to the inverter's
installation manual for more information about how to perform this task.
3. Install and close all covers and doors before applying power to the inverter. T he inverter must be powered on before
performing an upload or download.
4. Perform the desired transfer.
5. Upon completing the transfer, remove all power from the inverter and th e enclosures housing the inv erter and wait 15
minutes to allow the DC bus of the inverter to discharge.
6. Remove the Parameter writer communication cable from the inverter.
12
Page 14
E6581680
5. Configurationtransfers
5.1. Loading a configuration from an inverter
This procedure allows the user to retrieve a configuration file ("LOADFRMD00.CFG" to "LOADFRMD99.CFG") from an
inverter and load it onto the Parameter writer's SD card.
Main menu
Action
ENT
Action Config
MLD -> Device
1
Action Config
Device -> MLD
ENT
Action Config
XXXXXXXX
ENT
Device -> MLD
LoadFrmDxx.cfg
ENT
LoadFrmDxx.cfg
<<<<
LoadFrmDxx.cfg
<<<<<<<<
LoadFrmDxx.cfg
<<<<<<<<<<<<
Load config
Successful
2
STEP
Actions
• Turn the Parameter writer on using the ON/OFF button "F" (see section 3.2).
• Connect the Parameter writer to the inverter using the RJ45 cable (see section 4.2).
1
• Press "ENT" when the screen displays "Main menu / Action".
• Select the "Action Config / Device -> MLD" menu using the arrow keys and press "ENT".
• "Device -> MLD / LoadFromDevicexx" appe ars on the screen. Press ENT until the transfer
starts.
• "Load Config / Successful" : The configuration has been loaded successfully onto the
Parameter writer;
2
disconnect the RJ45 cable from the inverter. The inverter configuration file ("filexx.CFG") is
now loaded onto the Parameter writer's SD card.
• Pressing "ENT" returns the user to the "Action Config" menu.
Note :
•If a configuration file has already been loaded 100 files on to the Parameter writer's SD card, it will be overwritten by
the new configuration file from 101 files. Renaming the file on the S D card (via a PC connection) means that the u ser
can store more than one file on the SD card. ( "file.CFG" can be renamed as "file1.CFG" )
13
Page 15
5.2. Transferring the configuration to an inverter
This procedure allows the user to select the configuration file to be transferred to the inverter.
The user must already have:
-Loaded the inverter configuration file ("*.CFG”) onto the Parameter writer (see section ) 5.1
OR
-Generated the configuration file using PCM software and loaded this file onto the Parameter writer
E6581680
1
Main menu
Action
ENT
Action Config
MLD -> Device
ENT
Action Config
XXXXXXXX
MLD -> Device
Filename1
2
MLD -> Device
Filename2
MLD -> Device
FilenameN
ENTENTENT
FilenameX
>>>>
FilenameX
>>>>>>>>
FilenameX
ENT
>>>>>>>>>>>>
Store config
Successful
3
STEP
Procedure
• Turn the Parameter writer on using the ON/OFF button “F” (see section 3.2).
1
• Connect the Parameter writer to the inverter using the RJ45 cable (see section
• Press “ENT” when the screen displays “Main menu / Action”.
• Press “ENT” when the screen displays “Action Config / MLD -> Device”.
2
• Select the file to be transferred using the arrow keys and press “ENT” to start the transfer.
(see section
6.7).
• The configuration has been transferred successfully fro m the Parameter writer. Disconnect
3
the RJ45 cable from the inverter.
• Pressing “ENT” returns the user to the “Action Config / MLD -> Device” menu.
Note :
• Keep on pushing ESC key if the process of searching communication mode is canc eled.
• Display is changed faster by keeping on pushing or key.
14
4.2).
Page 16
E6581680
5.3. Transferring the configuration to more than one inverter using Quick Store
This procedure describes how to use the Quick Store function (see section 6.4) to duplicate configurations.
The user must already have:
-Loaded the inverter configuration file (*.CFG) onto the Parameter writer (see section ) 5.1
OR
-Generated the configuration file using PCM software and loaded this file onto the Parameter writer
(filename1, filename 2, etc.)
STEP
• Turn the Parameter writer on using the ON/OFF button "F" (see section 3.2).
1
2
3
Note :
• Keep on pushing ESC key if the process of searching communication mode is canc eled.
• Display is changed faster by keeping on pushing or key.
• Connect the Parameter writer to the inverter using the RJ45 cable (see section
• Press "ENT" when the screen displays "Main menu / Action".
• Press "ENT" when the screen displays "Action Config / MLD -> Device".
• Select the file to be transferred using the arrow keys and press "ENT" to start the transfer. If
no inverter is connected, a message "No device / connected" appears on the screen
(see section
• The configuration has been transferred successfully from the Parameter writer; disconnect the
RJ45 cable from the inverter.
• Connect the Parameter writer to the next inverter, then press the Quick Store key
• "Store Config Successful" : The configuration has been loaded successfully onto the
second inverter; remove the RJ45 cable from the inverter.
• This action can be carried out as many times as necessary.
6.7).
Transfer
4.2).
15
Page 17
6. Parameter writermenus
6.1.
Parameter writer main menu
On power-up, the "Parameter writer / Version "x.x"" menu is displayed on the screen.
The diagram below shows the various menus that can be accessed from the Parameter writer main menu.
Main menu / Action accesses the following functions:
-Load from Parameter writer to inverter
-Load from inverter to Parameter writer
Main menu / Device accesses the following information:
-Device type
-Device version
Main menu / Parameters accesses:
-Battery parameters
-Diagnostic parameters
-Password parameters
-Display parameters
E6581680
Main menu / About MLD accesses:
-Parameter writer version information
The Quick Store key (see section
(see section
6.4).
3.2) allows the user to transfer the most recent configuration file or update the inverter
16
Page 18
E6581680
6.2. Action: Load configuration from Parameter writer to inverter
The diagram below shows the "Action Config / MLD -> Device" menu accessible from "Main menu / Action".
"Action Config / MLD -> Device" : This menu accesses the transfer function for loading configurations from the
Parameter writer to the inverter.
Note :
• Keep on pushing ESC key if the process of searching communication mode is canc eled.
• Display is changed faster by keeping on pushing or key.
17
Page 19
E6581680
6.3. Action: Load configuration from inverter to Parameter writer
The diagram below shows the "Action Config / Device -> MLD" menu accessible from "Main menu / Action".
"Action Config / Device -> MLD" : This menu accesses the transfer function for loading configurations from the inverter
to the Parameter writer.
Note :
• Keep on pushing ESC key if the process of searching communication mode is canc eled.
• Display is changed faster by keeping on pushing or key.
18
Page 20
E6581680
6.4. Quick S t ore mode
This mode is used to transfer the latest configuration file (See section 5.2). (1)
The diagram below shows the Quick Store mode, which can be accessed after using either of the "Action Config / MLD
-> Device" menus.
Note 1: Quick Store mode can only be used after an initial transfer to an inverter has been completed.
* Files can only be transferred between inverters with the same reference.
19
Page 21
E6581680
6.5. Supervision
The diagram below shows the device main menu, accessible from "Main menu / Device". This supervisory menu is
used to check the reference and version of the inverter connected to the Parameter writer.
"Device Type" : This menu accesses the reference of the connected inverter.
"Device SW version" : This menu accesses the software version of the connected inverter.
20
Page 22
E6581680
6.6. Parameter settings: Batteries
The diagram below shows the "Parameters / Battery" menu accessible from "Main menu / Parameters".
"Battery / Charge level" : This menu displays the Parameter writer charge level.
"Battery / Alarm level" : This menu is used to set message activation at a particular charge level. It warns the user
about the battery charge status according to the set value (see message fault detected on section
"Battery / Set battery type" : This menu is used to select the type of battery used by the Parameter writer (normal
batteries or rechargeable batteries). Users must ensure that the correct battery type is selected so that the Parameter
writer can accurately display the charge level. This also affects message activation.
Parameters
Battery
ENT
Battery
Charge level
ENT
ESC
Battery
Alarm level
ENT
ESC
Battery
Set battery type
ENT
6.7).
ESC
ENT
Charge level
78%
Press and hold the up
or down arrow key to
define this level value
more quickly.
Value between
[0 and 50] %
Alarm level
20%
Alarm level
NN%
Save the level
ENT
ESC
ESC
Set battery type
Normal
Set battery type
Rechargeable
ENT
Save the battery type
ESC
ESC
21
Page 23
E6581680
6.7. Parameter settings: Diagnostics
The diagram below shows the "Parameters / Diagnostic" menu accessible from "Main menu / Parameters".
"Diagnostic / Fault History" : This menu accesses the detected fault history.
"Diagnostic / Clear Faults" : This menu is used to clear the detected fault history
See the table of
faults codes
below
Parameter writer display Probable cause Remedy
Warning:
Low Battery Level
Switch off Low battery
Store config fault
Load config fault
Wrong reference Fault
No device connected
No file selected
SD card fault
SD card
Write protected
Parameters
Diagnostic
ENT
ESC
Diagnostic
Fault History
Diagnostic
fault1
Diagnostic
fault2
Diagnostic
fault3
ENT
ESC
ESC
ESC
Diagnostic
Clear faults
ENT
Are you sure to
clear faults?
Clear faults
History done
The battery charge is low. The appearance
of this message depends on the charge
level defined by the user. (See setting
the detection section
6.6)
The battery charge is too low.
The Parameter writer will turn off.
ESC
ENT
ENT
ESC
List of cleared
faults codes
- Make sure you have a set of replacement
batteries to hand, as the current set have little
life left.
- Replace the batteries immediately. No more
transfers can be made.
Incomplete or incorrect transfer to the
inverter.
The inverter is in parameter change
prohibition state.
Incomplete or incorrect transfer from
the Parameter writer to the inverter
The inverter is in parameter read
- Check the RJ45 cable and both of its
connectors. Make sure the connection is
secure for the duration of the transfer. Restart
the transfer operation.
- Confirm the inverter parameter setting.
prohibition state.
Bad transfer to the inverter; the
configuration
file selected is not compatible with the
- Check that the configuration file is compatible
with the inverter to be configured.
destination inverter.
- Check the RJ45 cable and both of its
The inverter is not connected or is
incorrectly connected.
connectors. Make sure the connection is
secure for the duration of the transfer.
Connect the RJ45 cable.
No configuration file is selected. There is
no file present on the SD card.
The card is not recognized.
- Select a file to transfer. - Follow the
procedure for loading configuration files
described on section
5.1.
- Check that the SD card is inserted correctly.
- Check that the SD card is formatted correctly.
The SD card is locked. - Check if the SD card is locked.
Flash FW Fault
For factory use only-
22
Page 24
E6581680
6.8. Parameter settings: Password
"Parameters / Password FW"
For factory use only.
6.9. Parameter settings: Display
The diagram below shows the "Parameters / Display" menu accessible from "Main menu / Parameters".
"Display / Contrast" : This menu is used to set the display screen contrast.
"Display / Backlight" : This menu is used to set the display screen time. (OFF, ON, 1 to 5 seconds are selected)
"Display / Sleep mode" : This menu is used to set the Parameter writer's sleep mode.
"Display / Language" : This menu accesses the language selection for the Parameter writer interface.
Parameters
play
Dis
ENT
Display
Contrast
ENT
ESC
Display
Backlight
ENT
ESC
Display
Sleep mode
ENT
ESC
Display
Language
ENT
ESC
Set contrast
50
Set contrast
NN
ENT
Save the contrast
Press and hold the up
or down arrow key to
define the contrast
value more quickly.
Value between
[0 and 100]
ESC
ESC
ENT
Set backlight
3 sec
Set backlight
2 sec
Set backlight
1 sec
Set backlight
ON
Set backlight
OFF
ENT
Save the backlight
ESC
ESC
ESC
ESC
ESC
Set sleep mode
05 mn
Set sleep mode
NN mn
ENT
Save the sleep mode
Press and hold the up
or down arrow key to
define the sleep mode
value more quickly.
Value between
[1 and 60] min
ESC
ESC
ENT
Language
English
Language
日本語
Language
Français
Language
Italiano
Language
Deutsch
Language
Español
ESC
ESC
ESC
ESC
ESC
ESC
ENT
Save the language
23
Page 25
7.Specifications
Item Specifications
Part number PWU003Z
E6581680
Applicable model
Applicable OS
Communication
setting
Applicable battery
Service environment
Protective method IP20
Ambient temperature -10 to +50°C
Storage temperature -25 to +65°C
Relative humidity 20 to 93% (free from condensation and vapor)
Note) Update is needed this product’s software for future inverters.
VF-nC3 or successor Note)
Windows XP, Windows Vista, or Windows 7
Communication setting automatic detection
Communication baud rate : 4800, 9600, 19200, 38400 bps
Parity : Non / Even / Odd parity
Communication scheme: RS485
4 x LR6 (AA) alkaline batteries or
4 x NiMH rechargeable batteries
Indoor operation at an altitude of 1,000m or less and free from direct sunlight,
potentially corrosive or explosive gases, steam, dust particles, dust/dirt, and
machining fluids including grinding liquid and coolant
8. Warranty
Any part of the unit that is proved to be defective will be repaired free of charge under the following conditions:
1. This product will be repaired free of charge, if problem/fault occurs under normal handling within one year of
delivery and is caused obviously by a design or manufacturing defect.
2. The warranty applies only to the delivered unit.
3. For the following kinds of failure or damage, the repair cost shall be borne by the customer even within the
warranty period.
i) Failure or damage caused by improper or incorrect use or handling, or unauthorized repair or
modification of the inverter.
ii) Failure or damage caused by the unit falling or an accident during transportation after the purchase.
iii) Failure or damage caused by fire, salty water or wind, corrosive gas, earthquake, storm or flood, lightning,
abnormal voltage supply, or other natural disasters.
iv) Damage due to the use of Parameter writer for non-intended purposes.
4. If an additional warranty is provided then those conditions will also apply.
24