Programmable Controllers
April 2003
OIS40R
Remote Operator Interface Station
For Toshiba T-Series PLCs
The OIS40R is the same OIS (Operator Interface Station) as the OIS40 except that the PLC
communication port is selectable, RS232 or RS485. As a result, its location is not limited to the 2 m
maximum distance from the PLC like the OIS40. It can be located up to 1000 m (a little over ½ mile)
from the PLC.
Another new feature on the OIS40R is that the keypad overlay is included separately. The overlay
can easily be stuck on the OIS40R or replaced by a custom overlay which better describes the
application—giving the operator more guidance on operation / data entry.
Standard features include:
♦ 20 Character by 4 Line Display
♦ 8 Function / Macro Keys
♦ Numeric Key Pad for Data Entry
♦ Unlimited Screens & Tasks
(except by available memory)
♦ 8 User Programmable LEDs
♦ 16 Definable Alarms
(can be logged & printed)
SPECIFICATIONS PROTOCOLS
Power 24 VDC +/-10%, 2 W maximum Toshiba T-Series PLCs
Ke
ad IP65 rated keypad Toshiba V-Series Integrated Controllers
Temperature Operating: 0 to 50 degrees C
Storage: -25 to 80 degrees C
Humidity 10% to 90% (Non condensing) Special (check with Toshiba)
Bezel Size 101.30 H X 182.50 W, Depth:36.80
mm
Communication Connects to PLC RS232/R485 port
Immunit
Immunit
Radiated Susceptibility Level 3 as per IEC1000-4-3
Emission EN55011 CISPR A
to ESD Level 3 as per IEC1000-4-2
to Transients Level 3 as per IEC1000-4-4
Toshiba G7/S9/VF_nC1 ASDs
Modbus
ORDER NUMBERS DIMENSIONS
Part Numbers Description
OIS40R Operator Interface Station.
TKRS485 RS485 Communication Cable T2N) 2m w/ 15
pin D shell & pigtail.
CAB-OIS-T1-X RS232 Communication Cable 2m w/ 8 pin
mini DIN & 9 pin D-shell (T1)
CAB-OIS-T2-X RS232 Communication Cable (T2E/T2N/T3)
9830 Beldon RS485 Cable (or equivalent)
Communications Cable 24 AWG low
capacitance (T1, T2E, V-Series)
26-117B RadioShack RS232 Programming Cable
(or equivalent), 9 pin D shell (male & female)
Note: The OIS40R has a 9 pin D shell female connector for connection to the PLC. This connector can be setup as either
RS485 or RS232. For RS485 connection, one end of the Beldon 9830 cable must be terminated with a 9 pin D shell (male)
connector.
ADJUSTABLE SPEED DRIVES MOTORS CONTROLS UPS INSTRUMENTATION PLC DCS
Available Through:
13131 West Little York Rd Houston, TX 77041
Ph: 713-466-0277 Fax: 713-466-8773
US: 800-231-1412 Canada: 800-872-2192 Mexico: 001-800-527-1204
Email: plc@tic.toshiba.com
Website: www.tic.toshiba.com
Rev 2003.4.1