Size
(mm)
Flow rate
0.3m/s 1m/s 3m/s 10m/s
2.5 0.005301 0.01767 0.05304 0.1767
4 0.01357 0.04524 0.13572 0.4524
6 0.03053 0.1018 0.3054 1.018
15 0.1908 0.6361 1.908 6.361
25 0.5301 1.767 5.301 17.67
32 0.8686 2.895 8.686 28.95
40 1.357 4.523 13.57 45.23
50 2.120 7.067 21.20 70.67
65 3.583 11.95 35.83 119.5
80 5.428 18.09 54.28 180.9
100 8.482 28.27 84.82 282.7
125 13.25 44.17 132.5 441.7
150 19.08 63.61 190.8 636.1
200 33.93 113.1 229.3 1,131
250 53.01 176.7 530.1 1,767
300 76.34 254.5 763.4 2,545
350 103.9 346.4 1,039 3,464
400 135.7 452.3 1,357 4,523
450 171.7 572.5 1,717 5,725
500 212.1 706.9 2,121 7,069
600 305.4 1,018 3,054 10,180
700 415.6 1,385 4,156 13,850
750 477.1 1,590 4,771 15,900
800 542.9 1,810 5,429 18,100
900 687.1 2,290 6,871 22,900
Factory default standard value table
Code Item
Default value
Changed value
English unit SI unit
A3 Exicitation Frequency Value Value
A4 Flow Direction NORMAL NORMAL
B1 Display 1 gal/min m
3
/h
B2 Display 2 COUNT B m
3
Display digit setting
(For Display 1 and Display 2)
1/1000 1/1000
B3 Custom Coefficient 0 0
B4 Custom Unit Blank space in all field Blank space in all field
C1 Range Type SINGLE SINGLE
C2 Range 1 Value Value
C6 Hysteresis 3.0% 3.0%
D1 Damping Constant 5 sec 1 sec
D2 Rate-of-change Limit 0.0% 0.0%
D3 Control Limit Time 0.0s 0.0s
E1 Low Cutoff 1.0% 1.0%
E2 Display Low Cutoff LINEAR LINEAR
F2 Manual Zero 0.0% 0.0%
G1 4-20mADC Alarm Output 4mA 4mA
G2 Output Low Limit 4mA 4mA
H1 DO1 Function PLS OUT PLS OUT
H2 DO2 Function (*) EMPTY ALM NO USE
H3 DO1 Active Status NormOPEN NormOPEN
H4 DO2 Active Status (*) NormOPEN NormOPEN
I1 Digital input (*) C RS/ST C RS/ST
I2 DI Detective Level (*) H LEVEL H LEVEL
J1 Counting Rate Value Value
J2 Pulse width setting mode AUTO AUTO
J3 Preset width 5ms 100ms
K1 Preset count 00000000 00000000
K2 Preset Function HOLD HOLD
L1,L2 High Alarm Set / Value OFF 0.0% OFF 0.0%
L3,L4 Low Alarm Set / Value OFF 0.0% OFF 0.0%
M1,M2 High High Alarm Set / Value OFF 0.0% OFF 0.0%
M3,M4 Low Low Alarm Set / Value OFF 0.0% OFF 0.0%
N1 Empty Pipe Alarm NORMAL NORMAL
N2 Self-disgnosis function ON ON
N3 Alarm Output Preset CONV ONLY CONV ONLY
P1 Password 000 000
P2 LCD display adjustment 3 3
P3 Switch position setting BOTTOM BOTTOM
* These functions are option.
Meter Size
Ex.Freq
(Hz)
Range 1
Counting Rate
inch mm gal/min ft/s m
3
/h m/s
1/10'' 3 24 0.5 21.084 0.05 2.829 1 gal 1L
1/6'' 4 24 1.5 24.707 0.1 2.211 1 gal 1L
1/4'' 6 24 4 29.283 0.2 1.965 1 gal 1L
1/2'' 15 24 25 29.283 2 3.144 1 gal 0.01m
3
1'' 25 24 75 31.625 6 3.395 1 gal 0.01m
3
1 1/4'' 32 24 125 32.171 10 3.454 1 gal 0.01m
3
1 1/2'' 40 24 175 28.826 15 3.316 1 gal 0.01m
3
2'' 50 24 300 31.625 25 3.537 10 gal 0.1m
3
2 1/2'' 65 24 475 29.629 40 3.348 10 gal 0.1m
3
3'' 80 24 650 26.766 60 3.316 10 gal 0.1m
3
4'' 100 24 1,000 26.354 100 3.537 10 gal 0.1m
3
5'' 125 24 1,750 31.625 150 3.395 10 gal 0.1m
3
6'' 150 24 2,500 29.283 200 3.144 100 gal 1m
3
8'' 200 24 4,500 29.649 300 2.653 100 gal 1m
3
10'' 250 12 7,000 29.517 600 3.395 100 gal 1m
3
12'' 300 12 10,000 28.283 900 3.537 100 gal 1m
3
14'' 350 12 12,000 25.817 1,200 3.465 100 gal 1m
3
16'' 400 12 16,000 26.354 1,600 3.537 100 gal 1m
3
18'' 450 12 20,000 26.029 2,500 4.366 100 gal 1m
3
20'' 500 6 25,000 26.354 3,000 4.244 100 gal 1m
3
24'' 600 6 40,000 29.283 4,000 3.930 100 gal 1m
3
28'' 700 6 50,000 26.892 5,000 3.609 100 gal 1m
3
30'' 750 6 60,000 28.112 6,000 3.773 100 gal 1m
3
32'' 800 6 70,000 28.825 7,000 3.868 100 gal 1m
3
36'' 900 6 80,000 26.029 8,000 3.930 100 gal 1m
3
ERROR/ALARM
Error/Alarm type Indicating message Error contents
Self-diagnosis error ROM ERROR ROM error
RAM ERROR RAM error
PARAMETER FAILURE System parameter error
EXC CUR OPEN Excitation circuit error
EXC CUR ERROR Excitation current error
ADC ERROR ADC error
INVALID TOTAL Invaid totalizer counts
Settig error HIGH OVER SPEC Setting value exceeds the allowable high limit.
LOW OVER SPEC Setting value exceeds the allowable low limit.
HIGH OVER CNT RATE Counting rate exceeds the allowable high limit.
LOW OVER CNT RATE Counting rate exceeds the allowable low limit.
MULTI RNG ERROR Span is not appropriate for multi-range configuration.
Limit alarms HIGH ALARM Flow rate reading exceeds the high limit.
HIGH HIGH ALARM Flow rate reading exceeds the high high limit.
LOW ALARM Flow rate reading goes below the low limit.
LOW LOW ALARM Flow rate reading goes below the low low limit.
OVER 125% Measurement value exceeds the 125%
UNDER -125% Measurement value goes below the 125%
Empty pipe alarm EMPTY ALARM Detector pipe is not filled with fluid.
LCD
Meter Size vs. Velocity/Rate
Size
(inch)
Flow rate
0.98ft/s 3ft/s 10ft/s 32.8ft/s
1/10'' 0.02334 0.07115 0.2372 0.7781
1/6'' 0.05975 0.1821 0.6071 1.992
1/4'' 0.1344 0.4098 1.366 4.482
1/2'' 0.8403 2.561 8.532 28.01
1'' 2.334 7.115 23.72 77.81
1 1/4'' 3.824 11.66 38.86 127.5
1 1/2'' 5.975 18.21 60.71 199.2
2'' 9.337 28.46 94.86 311.2
2 1/2'' 15.78 48.09 160.3 526.0
3'' 23.90 72.85 242.8 796.7
4'' 37.35 113.8 379.4 1,245
5'' 58.35 177.9 592.9 1,945
6'' 84.03 256.1 853.8 2,801
8'' 149.4 455.3 1,518 4,980
10'' 233.4 711.5 2,372 7,781
12'' 336.1 1,025 3,415 11,200
14'' 457.5 1,394 4,648 15,250
16'' 597.5 1,821 6,071 19,920
18'' 756.3 2,305 7,684 25,210
20'' 933.7 2,846 9,486 31,120
24'' 1,344 4,098 13,660 44,820
28'' 1,830 5,578 18,590 61,000
30'' 2,101 6,403 21,340 70,020
32'' 2,390 7,285 24,280 79,670
36'' 3,025 9,221 30,740 100,800
unit : gal/min unit : m3/h
2008