BSINo. G00I100 Page 1
BSI No.: G00I100
Publish
2000/09/13
Date:
Subject: Cleaning Method of Developer Unit during Preventive Maintenance
Model: DP4580, DP5570, DP6570, DP8070
Category Field Application UNIT
Correction of Service Manual To be applied when necessary Developer
FactoryApplication: -
CONTENT
Regarding the method of cleaning the developer unit at the time of a preventive maintenance, since
the cleaning method of the development duct cover was not clear, a postscript and correction have
been made.
Clean the duct cover by means of the
following procedure immediately after
extracting the old developer material at the
time of PM (Periodical Maintenance).
(1) Turn over the developer unit.
(2) The claws on the right and left shown in
figure A on the right are removed from the
developer unit. (see arrow
withdrawn towards the front (see arrow
(3) Remove the dirt and toner from the duct.
(4) The new duct cover is attached using the
procedure opposite to that in (3). At this time,
be careful to how you turn the harness of
The projecting area of the duct should be slid
into the developer unit groove (arrow
), and the duct is
1
2
).
3
).
.
B