ADJUSTMENT
While holding the MUTE button, press MENU
Стр. 1 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
Service Mode
Entering to Service Mode
1. Set VOLUME to minimum and press MUTE
button twice on Control.
↓↓↓↓
↓↓↓↓
Service Mode display
2. Press MUTE button again and hold button
down.
3.
button on TV set.
Стр. 2 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Key Function in the Service Mode
The following key entry during display of adjustment menu provides special functions.
Selection of the adjustment items CH (on TV or remote control)
Change of the data value Volume +/- (on TV or remote control)
Adjustment menu mode ON/OFF MENU button (on remote control)
Reset the count of operating
protect circuit to "00"
"RCUT" selection 1 button
"GCUT" selection 2 button
"BCUT" selection 3 button
"CNTX" selection 4 button
"COLC" selection 5 button
"UVTT" selection 6 button
Self diagnostic display ON/OFF 9 button
CALL + CH button on TV ( )
Selecting the Adjusting Item
Every pressing of CH button in the service mode changes the adjustment items in the order of table below. ( button for reverse order)
SETTING & ADJUSTING DATA
[ SERVICE MODE ]
ADJUSTING ITEMS AND DATA IN THE SERVICE MODE:
Note:
(1) The image system data may be different for each image format chosen. The factory
preset data value is indicated in the table.
(a) Seine3 CR Data RF350U : DRMA0579 Rev00 (VX4A00019000)
Prior to changing any board containing an EEPROM IC, the exisiting data in each image
Стр. 3 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
(b) TV-MICRO EEPROM Data : DRMA0588 Rev00 (VX4A00019300)
(2)
format should be copied down as a precautionary measure.
Data
Item Name of adjustment
40RF350 46RF350
R-CUT R CUTOFF 00H 00H (a)
G-CUT G CUTOFF 00H 00H (a)
B-CUT B CUTOFF 00H 00H (a)
R-DRV R DRIVE 64H 64H (a)
G-DRV G DRIVE 64H 64H (a)
B-DRV B DRIVE 64H 64H (a)
*BRTC BRIGHTNESS CENTER 80H 80H (a)
*COLC COLOR CENTER 7DH 7DH (a)
*UVTT BASE BAND TINT 7EH 7EH (a)
*CNTX CONTRAST MAX 7FH 7FH (a)
SHRC SHARPNESS CENTER 60H 60H (a)
VBIS VBI Setting 64H 64H (a)
CC Closed Caption 64H 64H (a)
ID1 VBID 64H 64H (a)
GG Gemstar 00H 00H (a)
PHDT HPD TIME 09H 09H (a)
OPT1 TV SET OPTION 1 00H 00H (b)
OPT2 TV SET OPTION 2 00H 00H (b)
OPT3 TV SET OPTION 3 60H 60H (b)
Стр. 4 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
OPT4 TV SET OPTION 4 6EH 6AH (b)
OPT5 TV SET OPTION 5 01H 01H (b)
SET-ID MODEL ID *1 *1 (b)
MAGC AGC of MTS decoder 00H 00H (b)
V01 Volume1 Data 53H 53H (b)
V25 Volume25 Data A1H A1H (b)
V50 Volume50 Data D3H D3H (b)
V75 Volume75 Data EDH EDH (b)
V100 Volume100 Data F3H F3H (b)
VOLBS Correction Volume at DTV 00H 00H (b)
VOLST Correction Volume at Stereo/SAP of ATV 00H 00H (b)
EVOL Reduce Volume For Bassboost (Nonuse) 00H 00H (b)
VOLX Volume Limiter For Hotel 64H 64H (b)
BASX Bass Max Data 19H 19H (b)
TREX Treble Max Data 19H 19H (b)
TONN Tone Min Data 08H 08H (b)
BASC Bass center Data 01H FEH (b)
TREC Treble center Data 02H 02H (b)
EBAS Add Bass on FOCUS 01H 03H (b)
ETRE Add Treble on FOCUS FEH 01H (b)
WON2 Bass Reducer 0AH 0AH (b)
ALS ALS point 00H 00H (b)
ALOF Reduce in ALL (wow, TruSurround) off 00H 00H (b)
VSTB Reduce Volume For Stable Sound 00H 00H (b)
VS3D Reduce Volume For SRS3D 00H 00H (b)
VFCS Reduce Volume For FOCUS 04H 02H (b)
VTBH Reduce Volume For TruBass High 00H 00H (b)
VTBL Reduce Volume For TruBass Low 00H 00H (b)
VVDD Reduce Volume For Dolby F3H F3H (b)
WFCS FOCUS Level 02H 01H (b)
WWSP SRS 3D Level 02H 02H (b)
button will change the value of data in the range from 00H to
WTBH TruBass High Level 02H 02H (b)
Стр. 5 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
WTBL TruBass Low Level 01H 01H (b)
VOLM Volume coefficient at 1/2 Mute 32H 32H (b)
Factory preset data will be loaded after setting Model ID data.
Note:
(*1) SET-ID data is subject to the models.
Refer to Setting Panel Option Data and SET-ID Data for detail.
Adjusting the Data
Pressing of VOLUME or FFH. The variable range depends on the adjusting item.
Setting Panel Option Data and SET-ID Data
1. Panel option data is subject to OP4 and OP5. Enter to service mode and select menu of OP4 or OP5 by pressing P or P during
Display of adjustment menu. After selecting OPT4 or OPT5, press + or - to set
OPT4 or OPT5 value as table below.
2. Whenever using new AV-TN board to the set, set the SET-ID data according to panel
option data.
Set Size
RF350U 40 SAMSUNG - 6Eh - 60h 01h BAh
RF350U 46 SAMSUNG - 6Ah - 60h 01h BBh
Panel Maker OPT4
OPT3 OPT5 SET-ID
TOP Running change TOP Running change
Exit from Service Mode
Pressing POWER button to turn off the TV once.
Self Diagnostic Function
Стр. 6 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
1. Press "Recall" button on Remote Control during display of adjustment menu in the
service mode. This will bring up the "S" in the right corner of screen. Now press "9"
button on remote.
The diagnosis will begin to check if interface among IC's is executed properly.
2. During diagnosis, the following displays are shown.
(1) Version information of TV-MICRO : Display 1 byte data.
(2) Version information of TV-MICRO EEPROP : Display 1 byte data.
(3) Version information of DVD MPU : HL series not used.
(4) Revision of image file : LCD Model not used.
(5) Total brightness hour of TV. : Display 4 bytes data.
(6) Operation hour of TV in LOW mode : Display 4 bytes data.
(7) Operation hour of TV in HIGH BRIGHT mode : LCD Model not used.
(8) Number of times of TV ON/OFF. : LCD Model not used.
(9) Temperature display of thermo-Sensor. (DMD) : LCD Model not used.
(10) Temperature display of thermo-Sensor. (LAMP) : LCD Model not used.
(11) DMD Engine System status : LCD Model not used.
(12) TV-MICRO System status : Not used
(13) IIC-BUS status
Bus line normal is "None" displayed.
Стр. 7 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
When it is abnormal, the block name is displayed as follows.
"SCL-GND" (Red indication) : SCL-GND short circuit
"SDA-GND" (Red indication) : SDA-GND short circuit
"SCL-SDA" (Red indication) : SCL-SDA short circuit
"NG : MTS"
"NG : APRO"
"NG : AVSW"
LED Indication
The green and yellow LED lights on the TV (at the bottom center of the TV) indicate the
TV's status, as described below:
LED Indication Condition
1 Blue, Green and Yellow are off. Power supply OFF. (AC)
2 Blue, Green and Yellow are off. Power supply OFF. (Stand by)
3 Blue is on (solid). The TV is operating properly.
4 Yellow is on (solid). Power-On Mode set into the quick operation.
The power is supplied to Digital Board only.
5 Green blinks slowly. Abnormal operation of BUS line.
Turn the TV off and unplug the power cord, then plug
the power cord in again and turn the TV on.
6 Green blinks quickly. Power Protection Detection.
Turn the TV off and unplug the power cord, then plug
the power cord in again and turn the TV on.
7 Yellew blinks 3 times. The TV is rebooting.
Wait several seconds until the yellow LED stops
Стр. 8 из 8ADJUSTMENT [LCD Color Television] USA
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
blinking.
8 Green is on (solid).
Yellow is on (solid).
9 Green is on (solid).
Yellow is off.
10 Green is off.
Yellow is on (solid).
Upgrading in progress.
Upgrading succesful.
Upgrading failed.
FUNCTION AND OPERATION
Стр. 1 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
TV Front and Side Panel Controls and Connections
Стр. 2 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
FUNCTION AND OPERATION
Стр. 1 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
Learning about the Remote Control
Стр. 2 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Стр. 3 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Стр. 4 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
FUNCTION AND OPERATION
Стр. 1 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
Programming Channels into the TV's Channel Memory
Programming Channels Automatically
Стр. 2 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Стр. 3 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Manually Adding and Deleting Channels in the Channel Memory
Стр. 4 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
SAFETY INSTRUCTION
should enter the mouth, rinse the mouth thoroughly with water. If the fluid should contact the
When attaching the LCD module to the LCD cover, position it appropriately and fasten
Стр. 1 из 4Handling the LCD Module
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
Handling the LCD Module
Safety Precaution
In the event that the screen is damaged or the liquid crystal (fluid) leaks, do not breathe in or
drink this fluid.
Also, never touch this fluid. Such actions could cause toxicity or skin irritation. If this fluid
skin or clothing, wipe off with alcohol, etc., and rinse thoroughly with water. If the fluid
should enter the eyes, immediately rinse the eyes thoroughly with running water.
Precautions for Handling the LCD Module
CAUTION: The metal edges of the LCD module are sharp, handle it with
care.
The LCD module can easily be damaged during disassembly or reassembly; therefore,
always observe the following precautions when handling the module.
1.
at the position where the display can be viewed most conveniently.
2. Carefully align the holes at all four corners of the LCD module with the corresponding
holes in the LCD cover and fasten with screws. Do not strongly push on the module
because any impact can adversely affect the performance. Also use caution when
handling the polarized screen because it can easily be damaged.
Стр. 2 из 4Handling the LCD Module
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
3. If the panel surface becomes soiled, wipe with cotton or a soft cloth. If this does not
remove the soiling, breathe on the surface and then wipe again.
If the panel surface is extremely solied, use a CRT cleaner as a cleaner. Wipe off the
panel surface by drop the cleaner on the cloth. Do not drop the cleaner on the panel.
Pay attention not to scratch the panel surface.
4. Leaving water or other fluids on the panel screen for an extended period of time can
result in discoloration or stripes. Immediately remove any type of fluid from the screen.
5. Glass is used in the panel, so do not drop or strike with hard objects. Such actions can
damage the panel.
6. CMOS-LSI circuitry is used in the LCD module, so avoid damage due to static
Стр. 3 из 4Handling the LCD Module
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
electricity. When handling the module, use a wrist ground or anchor ground.
7. Do not expose the LCD module to direct sunlight or strong ultraviolet rays for an
extended period of time.
8. Do not store the LCD module below the temperature conditions described in the
specifications. Failure to do so could result in freezing of the liquid crystal due to cold
air or loss of resilience or other damage.
9. Do not disassemble the LCD module. Such actions could result in improper operation.
Стр. 4 из 4Handling the LCD Module
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
10. When transporting the LCD module, do not use packing containing epoxy resin
(amine) or silicon resin (alcohol or oxim). The gas generated by these materials can
cause loss of polarity.
PANEL IDENTIFICATION
name, the identification marking will be shown at the last digit of the set serial number on the
Стр. 1 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
Panel Identification
If the several panels are alternatively used in the same model without amending the model
specification label on the back cover.
In servicing, do not alter the panel because several setting and parts are different.
Marking Panel Vendor Marking Panel Vendor Marking Panel Vendor
A AUO J
B
C CMO L LPL U
D
E
F
G
H IPS R
K SAMSUNG T
M
N
P
Q
S SHARP
V
W
X
Y
Z
With this alternative use, some of key parts may differ and their combinations are
indicated with the suffix marking on the location number in the part list
(Miscellaneous).
e.g.
Location No. Part No. Description
B001A
B001B
MZ01A
MZ01B
75007869 LCD Panel, 32" LPL
75007870 LCD Panel, 32" AUO
75006036 LDVS Cable
75007893 LDVS Cable
U03D
Key
U03B
FRONT-
AV
U02A
LOW-B
U03A
AV TERM
U01A
POWER
U04A
Digital
U03C
LED/IR-PATH
U03E
ILLUMINATION
SAFETY INSTRUCTION
Always keep tools, components of the product, etc away from the children, These items
Стр. 1 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
WARNING: BEFORE SERVICING THIS CHASSIS, READ THE "SAFETY
PRECAUTION" AND "PRODUCT SAFETY NOTICE" INSTRUCTIONS BELOW.
Safety Precaution
WARNING: SERVICING SHOULD NOT BE ATTEMPTED BY ANYONE
UNFAMILIAR WITH THE NECESSARY PRECAUTIONS ON THIS RECEIVER.
THE FOLLOWING ARE THE NECESSARY PRECAUTIONS TO BE OBSERVED
BEFORE SERVICING THIS CHASSIS.
1. An isolation transformer should be connected in the power line between the receiver
and the AC line before any service is performed on the receiver.
2. Always disconnect the power plug before any disassembling of the product. It may
result in electrical shock.
3. When replacing a chassis in the cabinet, always be certain that all the protective
devices are put back in place, such as nonmetallic control knobs, insulating covers,
shields, isolation resistor-capacitor network, etc.
4.
may cause injury to children.
5. Depending on the model, use an isolation transformer or wear suitable gloves when
servicing with the power on, and disconnect the power plug to avoid electrical shock
when replacing parts. In some cases, alternating current is also impressed in the
chassis, so electrical shock is possible if the chassis is contacted with the power on.
6. Always use the replacement parts specified for the particular model when making
repairs. The parts used in products require special safety characteristics such as
inflammability, voltage resistance, etc. therefore, use only replacement parts that have
NEVER remodel the product in any way. Remodeling can result in improper operation,
cabinet such as antennas, terminals, screw heads, metal overlays, control shafts and etc.
The leakage current checking. (After completing the work, measure the leakage current
Стр. 2 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
these same characteristics. Use only the specified parts when the mark is indicated in the circuit diagram or parts list.
7. Parts mounting and routing dressing of wirings should be the same as that used
originally. For safety purposes, insulating materials such as isolation tube or tape are
sometimes used and printed circuit boards are sometimes mounted floating. Also make
sure that wirings is routed and clamped to avoid parts that generate heat and which use
high voltage. Always follow the manufactured wiring routes / dressings.
8. Always ensure that all internal wirings are in accordance before re-assembling the
external casing after a repairing completed. Do not allow internal wiring to be pinched
by cabinets, panels, etc. Any error in reassembly or wiring can result in electrical
leakage, flame, etc., and may be hazardous.
9.
malfunction, or electrical leakage and flame, which may be hazardous.
10. Always perform an AC leakage current checking on the exposed metallic parts of the
to be sure that the set is safe to operate without any dangerous of electrical shocks
before returning the set to the customer.
11.
to prevent an electrical shock.)
Plug the AC line cord directly into a 120V AC outlet. Do not use an isolation
transformer for this check.
Use an AC voltmeter having 5000 ohms per volt or more sensitivity in the following
manner.
Connect a 1500 ohm 10 watt resistor, paralleled by a 0.15 µF, AC type capacitor,
between a known good earth ground (water pipe, conduit, etc.) and the exposed
metallic parts, one at a time. Measure the AC voltage across the combination of 1500
ohm resistor and 0.15 µF capacitor. Reverse the AC plug at the AC outlet and repeat
AC voltage measurements for each exposed metallic part. Voltage measured must not
exceed 0.3 volts rms. This corresponds to 0.2 milliamp. AC. Any value exceeding this
limit constitutes a potential shock hazard and must be corrected immediately.
Стр. 3 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Product Safety Notice
Many electrical and mechanical parts in this chassis have special safety-related
characteristics. These characteristics are often passed unnoticed by a visual inspection and
the protection afforded by them cannot necessarily be obtained by using replacement
components rated for higher voltage, wattage, etc. Replacement parts which have these
special safety characteristics are identified in this manual and its supplements; electrical
components having such features are identified by the international hazard symbols on the
schematic diagram and the parts list.
Before replacing any of these components, read the parts list in this manual carefully. The
use of substitute replacement parts which do not have the same safety characteristics as
specified in the parts list may create electrical shock, fire, or other hazards.
SPECIFICATION
Стр. 1 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\toshiba_40rf350u_sm\40RF3
...
Стр. 2 из
15.05.2015
file://D:\Documents and Settings\Admin\
Рабочий стол
\
toshiba_40rf350u_sm\40RF3
...
Acceptable signal formats for PC IN and HDMI terminals