Digital Media Network Company
CTV & Visual Media Equipment Div.
International Customer Servic e & Support Dept. [34F-A]
1-1,SHIBAURA 1-CHOME, MINATO-KU T OKYO 105-8001,JAPAN
PHONE:(03)3457-3536
FACSIMILE:(03)5444-9408
SERVICE INSTRUCTION
Product: LCD TV
Model: 26/32HL84, 26/32WL46B/G/C/A/E/R/T
Corrective Action: Backlight Lamp unit as a service part
Part No. Description Model applied
File No.01C2005002R
Date: Mar.11,2005
Rank: C
23587241 Back light unit 26HL84, 26WL46B/G/C/A/E/R/T
23587242 Back light unit 32HL84, 32WL46B/G/C/A/E/R/T
Product Safety Precautions:
Product Safety Precautions are described in Toshiba service manuals
020-200403 and 020-200405 for the model(s) covered in this bulletin. All
safety precautions and checks shall be complied with before returning the
equipment to the customer. Servicers who defeat safety features or fail to
perform safety checks may be liable for any resulting damages and may
expose themselves and others to possible injury.
__________________
Hideto Kitamura
Manager
International Customer
Service & Support Dept.
©2005 TOSHIBA AMERICA CONSUMER PRODUCTS, LLC

Model: 26HL84, 26WL46B/G/C/A/E/R/T
1. Cautions for Backlight Lamp Unit Replacement
The backlight lamps used in the listed Liquid Crystal Display (LCD) modules are
consumables. Follow the included replacement procedures when replacing these
components.
Disconnect AC power before starting the replacement procedure. The high
voltage applied to the backlight lamps produces an electrical shock hazard if
caution is not used when servicing this area.
Backlight lamp units are fragile and caution should be used when handling.
Ferrite cores are attached to the backlight lamp units with double-sided adhesive
tape. Use caution when removing these ferrite cores, as excessive force may
cause damage.
Where possible, replace backlight lamp units in a clean and dust-free environment.
TFT-LCD Module Bottom view
Return FFC
INV board
(HOT) side
INV board
(GND) side
INV cover
C board cover
C board
Flat cables
Ferrite cores
2004 LCD Television
Service Instruction
Page 1 of 1
2

2. Removing C Board Cover and C Board
2.1. Remove the two screws securing the C board cover.
2-2. Remove the two screws securing the C board. Remove the C board and
connectors, using caution to remove the ferrite cores.
Use caution when removing the ferrite
cores, as excessive force may cause
damage.
Service Instruction
2004 LCD Television
Page 2 of 12

3. Removing INV Cover and INV Board (HOT Side / GND Side)
3-1. Remove the return FFC connected to the INV board.
3-2. Remove the three screws securing the INV cover.
3-3. Disconnect the seven lamp unit connectors and remove the three screws
securing the INV board (HOT side).
3-4. Disconnect the seven lamp unit connectors and remove the seven screws
securing the INV board (GND side).
Service Instruction
2004 LCD Television
Page 3 of 12