Toro 730 User Manual

Introduction
__________________________________
The 730 Series Full Circle Rotary Sprinklers are designed for irrigation of large turf areas such as golf courses, parks, recreational fields and school grounds.
Manufactured from durable, high strength engineering plastic and stainless steel components, these sprinklers incorporate many innovative and time proven features for lasting, maintenance-free operation.
Prior to installing the sprinkler, read through the recommended installation and start-up procedures. Please observe all
Warnings and Cautions when
installing and operating this equipment.
1
730 Series Rotary Sprinklers
Installation & Service Instructions
A
U
T
O
O N
O
F
F
7
3
4
3 INCH
P
O
P
-U
P
730 Electric Valve-In-Head
Features
______________________________
Full 3" (7.6 cm) pop-up clears tall grasses
Nozzles color-coded by radius and gallonage
Caps serve as yardage markers or effluent water indicators
Variable stator
Three standard pressure regulation settings available to
ensure consistently accurate nozzle performance regardless of elevation
Four body styles/activation types available to fit every
application: Electric VIH, Normally Open Hydraulic VIH and Check-O-Matic (COM)
Manual control at the sprinkler, On-Off-Auto (Electric )
Bowl-vented discharge (atmospheric) minimizes the
differential pressure required for regulation and ensures positive valve closure (Electric)
All internal components serviceable from the top of the
sprinkler
Seven color-coded nozzles available
Durable plastic and stainless steel construction
Specifications
__________________________
Radius: 52 ft. – 83 ft. (15.8 m – 25.3 m)
Flow Rate: 11.0 41.2 GPM (41.6 155.7 l/mn) (2.5 9.4 m
3
/hr)
Arc: Full Circle
Maximum Pressure:
Electric VIH - 150 PSI (10.5 kg/cm
2
) (1034.5 kPa)
NO Hyd. VIH - 100 PSI (7.0 kg/cm
2
) (689.7 kPa)
Check-O-Matic - 100 PSI (7.0 kg/cm
2
) (689.7 kPa)
Body Height: 10 in. (25.4 cm)
Pop-Up Height: 3 in. (7.6 cm)
1 in. NPT, ACME or BSP Female Thread Inlet
Solenoid: 24 V a.c., 50/60 Hz
Inrush Current: 50 Hz, 0.47 Amps (11.3 VA)
60 Hz, 0.40 Amps (9.6 VA)
Holding Current: 50 Hz, 0.32 Amps (7.7 VA)
60 Hz, 0.30 Amps (7.2 VA)
Manual Control: On-Off-Auto
COM model checks up to 37 ft. (11.3 m) of elevation.
Color-Coded Nozzles
Conversion Information
730 SERIES NOZZLE PERFORMANCE — U.S.
Rad = feet GPM = gallons per minute*= Pressure regulation
= Nozzles not recommended at this pressure
= Toro recommends the use of a 11⁄4" swing joint at flows over 25 GPM Sprinkler radius of throw per ASAE standard S398.1
BASE
PRESSURE
YELLOW ORANGE BROWN BLUE GREEN RED GRAY
NOZZLE SET NOZZLE SET NOZZLE SET NOZZLE SET NOZZLE SET NOZZLE SET NOZZLE SET
31 32 33 34 35 36 37
PSI Rad GPM Rad GPM Rad GPM Rad GPM Rad GPM Rad GPM Rad GPM
50 52 11.0 55 13.3 60 16.8 62 19.8 66 25.0 68 26.5 69 29.3 55 53 12.0 56 14.1 61 17.2 63 20.6 67 25.8 69 27.9 70 30.7 60 54 13.0 57 14.9 62 17.5 64 21.4 68 26.6 71 29.2 72 32.1 65 55 14.0 58 15.7 63 17.9 65 22.2 69 27.4 72 30.6 74 33.5 70 56 14.5 59 16.3 64 18.6 66 22.8 70 28.1 73 31.4 76 34.8 75 56 15.0 59 16.9 64 19.3 66 23.4 70 28.8 75 32.2 78 36.1 80 57 15.5 60 17.5 65 20.0 67 24.0 71 29.5 76 33.0 80 37.4 85 58 15.9 61 17.8 66 21.0 68 25.0 72 31.0 77 34.3 81 38.2 90 59 16.3 61 18.1 67 21.9 70 26.1 73 32.5 78 35.5 82 39.3 95 59 16.6 62 18.4 67 22.9 71 27.1 74 34.0 79 36.8 82 40.2
100 60 17.0 62 18.7 68 23.8 72 28.1 75 35.5 80 38.0 83 41.2
All gallons per minute shown are U.S.
To convert to Imperial gallons per minute, multiply by .833.
To convert to liters per minute, multiply by 3.78.
To convert pounds per square inch (PSI) to atmospheres, divide by 14.7.
To convert pounds per square inch (PSI) to kilograms per square centimeter (kg/cm2) divide by 14.22.
To convert feet to meters, divide by 3.28.
To convert inches to millimeters, multiply by 25.4.
Installation Procedure _____________________
CAUTION Golf sprinklers are intended for installation at grade with full support of the body and piping system from the surrounding earth. Failure to provide full support may result in premature failure of the body and/or connecting fittings.
To assure maximum performance from your 734 Series Rotary Sprinklers, read these instructions completely prior to installation or service.
Swing Joints
1. Construct or provide triple swing joints for each sprinkler as shown in Figure 1. Use PVC or ABS pipe nipple for sprinkler connection.
Note: On sites where the possibility of heavy equipment rolling over a sprinkler exists, the swing joint will flex preventing damage to the lateral or main lines. On a new installation in raw ground where the sprinklers are to be initially installed above the finished grade and lowered when new turf is established, the swing joint allows sprinkler repositioning without changing risers. This is a common and practical procedure which eliminates the problem of dirt being accidentally introduced into the lateral lines when a riser is changed.
2. Flush lines thoroughly prior to installing sprinkler.
3.
NPT and BSP Threaded Models
Apply plumbing tape on riser threads. Install sprinkler onto riser
and tighten.
ACME Threaded Models
Install ACME threaded bodies onto Acme threaded swing joint
by threading clockwise until hand tight
Note: ACME threaded swing joints have an o-ring that seals to the sprinkle. Plumbing tape is not required..
CAUTION Use only plumbing tape on riser threads. Use of pipe dope or other types of sealing compounds can cause deterioration of sprinkler body threads.
Connecting Electric Control Wires
1. Route control wires to sprinkler location(s). Provide enough extra wire at sprinkler to allow for movement of sprinkler without straining wire connections. One common wire and station wire is required for each sprinkler. See Wire Sizing Chart,
Table 1 for proper
application.
2. Attach control wires to solenoid leads using an approved waterproof splicing method.
CAUTION All wires must be waterproofed to prevent short circuit to ground and subsequent controller damage.
2
VOLTAGE
WIRE NUMBER
AT
SIZE OF VALVES
CONTROLLER
CONTROL COMMON 1 2 3 4 23 V a.c. 14 14 2348 1012 549 353 23 V a.c. 14 12 2890 1239 673 433 23 V a.c. 14 10 3378 1448 786 505 23 V a.c. 12 12 3759 1604 873 561 23 V a.c. 12 10 4591 1973 1071 688 23 V a.c. 12 8 5411 2328 1263 812 23 V a.c. 10 10 5945 2555 1387 892 24 V a.c. 14 14 2765 1309 846 549 24 V a.c. 14 12 3393 1608 1039 673 24 V a.c. 14 10 3962 1877 1213 783 24 V a.c. 12 12 4394 2082 1346 872 24 V a.c. 12 10 5397 2557 1652 1071 24 V a.c. 12 8 6364 3018 1949 1263 24 V a.c. 10 10 6986 3311 2140 1387
Table 1: Wire Sizing Chart
Maximum allowable length in feet from controller to electric VIH sprinklers.
OUTPUT
VOLTAGE AT
CONTROLLER
TRANSFORMER
Figure 1: Triple Swing Joints
(NPT & BSP models only)
(ACME
models only)
NOTE: Minimum solenoid voltage required for reliable electric
VIH operation is 20 V a.c.
Chart based on the following
Transformer - 115/230 V a.c. - 24 V a.c., 45 VA Coil Assy. - 24 Va.c., 60 Hz Holding - .30 Amps In Rush - .40 Amps
Connecting Hydraulic Control T ubing
1. Route control tubing from controller to sprinkler location(s).
NOTE:
Leave an 18" (45.7 cm) service loop of tubing at each
sprinkler to facilitate movement of sprinkler and service operations.
Tubing runs in excess of 1,000' (304.8 m) are not
advisable due to delayed response time.
The valve elevation for normally open valve-in-head
systems should not exceed 25' (7.6 m) above controller elevation or 70' (21.3 m) below controller elevation.
The valve elevation for normally closed valve-in-head
systems should not exceed 0' above controller elevation or 70' (21.3 m) below controller elevation.
If connecting more than one VIH sprinkler per control
tubing run, refer to the chart below.
2. Flush tubing thoroughly to remove all air and debris.
3. Remove tube retainer and poly cap from tubing adapter at base of sprinkler.
4. Slide tube retainer over control tubing and attach tubing to adapter.
5. Slide tube retainer over adapter area to secure tubing.
System Start-Up
The following is a recommended procedure that will protect system components during system start-up. The procedure is based on a velocity fill rate of less than 2' (0.6 m) per second. See Table 2 below.
1. Use jockey pump only to fill system at velocity fill rate of less than 2' (0.6 m) per second.
2. Use quick coupler keys at all tees and greens with quick coupler valves to bleed air from system lines during filling process. Do not compress air and then relieve, bleed air while filling system.
3. After water has filled all lines and all air is removed, remove quick coupler keys.
CAUTION Failure to comply with recommended fill rate will increase line pressure resulting in a water hammer effect that could damage sprinklers and/or piping system.
Table 2: Recommended System Fill Rate
3
Recommended Maximum
1" VIH 3 5
1.5" VIH 2 3
Table 2: Control Systems
Maximum Distance
Type of System* From Controller Elevation Restrictions Pin-type£ (00) Hydraulic*
with 3⁄16" Control Tubing 100' Pin-type£ (00) Hydraulic*
with 1⁄4" Control Tubing 200' Normally Open (01) Valve elevation should not exceed
with
3
16" Control Tubing 500' 25' ABOVE controller elevation or
70' BELOW controller elevation.
Normally Closed (08) Valve elevation should not exceed with
3
16" Control Tubing 500' 0' ABOVE controller elevation or
70' BELOW controller elevation.
Normally Open (01) Valve elevation should not exceed with
1
4" Control Tubing 1000' 25' ABOVE controller elevation or
70' BELOW controller elevation.
Normally Closed (08) Valve elevation should not exceed with
1
4" Control Tubing 1000' 0' ABOVE controller elevation or
70' BELOW controller elevation.
Pipe Size Flow Velocity Pipe Size Flow Velocity
in. cm GPM LPM ft/sec m/sec in. cm GPM LPM ft/sec m/sec 1/2 1.3 2 7.6 1.60 0.49 3 7.6 45 170.3 1.86 0.57 3/4 1.9 3 11.4 1.92 0.59 4 10.2 75 283.9 1.87 0.57
1 2.5 5 18.9 1.50 0.46 6 15.2 150 567.8 1.73 0.53 1-1/4 3.2 10 37.9 1.86 0.57 8 20.2 250 946.3 1.70 0.52 1-1/2 3.8 10 37.9 1.41 0.43 10 25.4 450 1703.3 1.97 0.60
2 5.0 20 75.7 1.80 0.55 12 30.5 500 1892.5 1.55 0.47 2-1/2 6.4 30 113.6 1.84 0.56
* - All hydraulic connections on Toro valves are 1⁄4" insert type.
- Control line pressure must be equal to or 10% greater than mainline pressure.
- Control line pressure range is 40 to 150 PSI
£
NOTE: Maximum of one (1) valve pr station on pin-type systems.
WARNING
DUE TO HIGH OPERATING PRESSURE, NEVER STAND OR LEAN DIRECTLY OVER TOP OF SPRINKLER OR COME IN CONTACT WITH SPRAY. FAILURE TO COMPLY MAY RESULT IN SERIOUS INJURY.